KITOZER
KITOZER

KITOZER VRLA Battery 12V 100Ah For UPS Backup

Product Overview

The KITOZER 12V 100Ah VRLA (valve-regulated lead-acid) battery is a maintenance-free, sealed energy storage module designed as the standard DC source for online UPS systems, EPS emergency power, and telecom backup plants. Using AGM (absorbent glass mat) technology, the battery suspends electrolyte in fiberglass separators so it can be mounted in any orientation without leakage, and the recombinant valve minimizes water loss over the design life. The 12V 100Ah rating is one of the most widely specified sizes for 10kVA to 40kVA UPS systems and 30-minute to 2-hour backup packages. Each block is factory-tested for capacity, internal resistance, and open-circuit voltage before shipment, and matched within tight tolerance to ensure balanced performance when wired in long series strings.

Technical Specifications

Nominal voltage 12V, rated capacity 100Ah at 20-hour rate to 1.75V per cell at 25 degrees Celsius. Internal resistance approximately 4.5 milliohms. Maximum discharge current 1000A for 5 seconds. Operating temperature -15 to 50 degrees Celsius, optimal 25 degrees Celsius. Float charging voltage 13.6 to 13.8V, cyclic charge 14.4 to 15.0V. Design life 5 to 7 years at 25 degrees Celsius in float service. Dimensions 330 x 173 x 214 millimeters, weight 30 kilograms. Terminal type M8 bolt. Compliance includes IEC 61056, JIS C 8702, UL, CE, and ISO 9001. Self-discharge is less than 3 percent per month at 25 degrees Celsius, allowing up to 12 months storage before recharge. The container is made from flame-retardant ABS rated UL94 V-0. Valve operation pressure is 1 to 3 psi, and the case is sealed against splashing water.

Application Scenarios

Common applications include UPS DC buses from 48V to 384V, EPS emergency lighting systems, telecom base station rectifiers, solar and wind storage banks, security alarm systems, and marine engine starting. The 12V 100Ah block is also frequently used in electric forklift support, golf buggy auxiliary power, and railway signal backup installations. It is a standard building block for 10kVA and 20kVA online UPS systems in small data centers, bank branch rooms, hospital IT closets, and factory automation panels. Because it is a universal form factor, spare blocks can be shared across multiple UPS brands on site, simplifying inventory for facilities management teams.

Advantages and Features

AGM recombination technology eliminates watering and periodic electrolyte checks. The sealed construction permits installation in offices and equipment rooms without acid-gas corrosion concerns. Low self-discharge of less than 3 percent per month allows up to 12 months storage before recharge. Robust ABS flame-retardant container meets UL94 V-0 standards. Copper-terminated posts reduce resistance and support high-current discharge for UPS inverter surge loads. Consistent manufacturing tolerance ensures balanced performance when 20 to 40 blocks are series-connected in a battery string. The long float life of 5 to 7 years at 25 degrees Celsius lowers total cost of ownership compared with cheaper unbranded alternatives, and the deep-discharge recovery is good enough for sites with frequent outages. Each battery ships with a unique serial number for traceability and warranty tracking.

Installation and Maintenance Recommendations

Rack the batteries on ventilated steel shelves or purpose-built battery cabinets, leaving at least 10 millimeters clearance between blocks for airflow. Use insulated torque wrenches and torque terminals to manufacturer specification to avoid loose connections. Keep the battery room at 20 to 25 degrees Celsius; every 10 degrees above 25 halves battery life. After installation, perform a 24-hour equalizing charge before connecting the UPS inverter. Test each block voltage monthly under float and quarterly under load, and record internal impedance annually with a conductance tester. Replace any block that drops more than 20 percent below the string average. Transport in original upright packaging and never tilt more than 90 degrees. Keep the area clean and dry, and post hazard signage on the battery cabinet. Do not store metal tools on top of the batteries, because a dropped wrench across terminals can cause severe arcing.

Delivery and Warranty

Batteries are packed in strong cartons on pallets, with 4 blocks per pallet layer and 24 blocks per full pallet. Standard lead time is 5 to 10 working days, and sea freight to major ports takes 25 to 35 days. Each block carries a 3-year free replacement warranty from the date of shipment, provided it is installed and charged within 6 months of delivery. KITOZER supplies a UN38.3 test summary, CE certificate, and dimensional drawing with every order. Bulk orders of 100 blocks or more qualify for volume pricing, and mixed-container shipments with battery racks or cabinets are supported. English documentation and battery disposal guidance are included.

Compatibility

The 12V 100Ah block is a universal form factor compatible with most major UPS brands, EPS systems, and telecom rectifiers on the market. It can be wired in series strings from 48V up to 384VDC, and parallel strings are supported for higher capacity. The M8 terminal matches standard cable lugs used in battery cabinets. English datasheets, dimension drawings, and UN38.3 documentation are available for every order. Mixed pallet shipments with battery racks, cabinets, and interconnect bars are supported.

Price

From $85/pc. Contact +86 13922289957 for full-string pricing, pallet quantities, and battery cabinet bundle packages.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top