Table of Contents
ToggleProduct Overview
The KITOZER 1000kW container diesel generator is a turnkey outdoor power station built inside a standard 40-foot high-cube ISO container. A megawatt-class turbocharged diesel engine and heavy-duty brushless alternator are mounted on a reinforced steel skid, complete with fuel tank, exhaust system, control cubicle, ventilation, lighting, and fire suppression. The container protects the set from rain, dust, and extreme temperatures, allowing installation in remote construction sites, mining camps, oil fields, and disaster-recovery zones without a dedicated plant room. KITOZER delivers the unit pre-wired and pre-tested, so the customer only needs to connect power cables, fuel supply, and exhaust extension.
Technical Specifications
Rating: 1000kW prime, 1100kW standby, 0.8 power factor, three phase. Engine is a high-displacement vee-twelve or vee-sixteen turbocharged diesel displacing 38 to 50 liters, governed at 1500rpm. Alternator is single-bearing brushless with AVR, class H insulation, IP23, and waveform distortion below 4 percent. Sound pressure at 7 meters is 85 dBA with acoustic-lined container walls. Fuel consumption at 75 percent load is about 230 liters per hour, and the integrated base tank supports 6 hours of running. The container includes engine room ventilation louvers with baffles, forced exhaust extraction, internal LED lighting, 24V and 220V socket outlets, fire suppression nozzle, and smoke detection. Control cubicle houses a deep-sea AMF and load-share controller, Modbus TCP, Ethernet, GSM, and power distribution breakers. Container is ISO 40-foot high cube, CSC certified, weatherproof, and forklift or crane liftable. Weight is approximately 24,000kg.
Applications
This 1000kW container set is used as prime power for remote mines, oil field camps, and large construction sites where grid connection is absent. Disaster-recovery organizations deploy it to restore power to hospitals, water plants, and emergency shelters after earthquakes or storms. Events and film crews use it as silent megawatt power for outdoor concerts and productions. Data centers and utilities also use it as a temporary mobile substation during scheduled plant maintenance. Because the container is ISO certified, it can be transported by truck, rail, or ship to almost any location in the world.
Advantages and Features
KITOZER builds the container package with acoustic-lined walls, baffle chambers for intake and exhaust, and a dedicated engine ventilation system. Wide double doors at both ends give full access to the engine, alternator, filter pack, and control cubicle. The integrated base tank includes fuel level sensor, drain plug, leak tray, and connection to an external fuel bowser. Standard features: AMF and load-share controller, dual 24V starting, float battery charger, jacket water heater, anti-vibration mounts, emergency stop, fire suppression, smoke detection, internal lighting, and Modbus TCP. Optional items include remote fuel tank of 10,000 to 50,000 liters, GSM remote monitoring, parallel kit, Arctic package with engine and room heaters, tropical cooling, and power distribution panel with outgoing feeders.
Installation and Maintenance Recommendations
Place the container on a level compacted pad or concrete foundation, level it with twist locks, and keep 2 meters clearance at each end for door swing and ventilation. Connect an external fuel tank with leak bunding and fuel polishing loop if running beyond the base tank capacity. Route exhaust gases through the built-in silencer and extend vertically with insulated piping. Connect the upstream power cables to the internal distribution panel, and configure the AMF controller for automatic start on utility failure. Maintenance: oil and filter every 250 hours, fuel filter every 500 hours, coolant analysis every 6 months, valve lash every 2000 hours, injector calibration every 4000 hours, alternator bearing inspection every 10000 hours, fire suppression inspection every 6 months, and load-bank test annually. Remote monitoring via GSM is recommended for remote sites where service visits are infrequent.
Typical Customer Configuration
A typical KITOZER package for the 1000kW container set includes a 10,000L external fuel tank, a parallel cabinet for multi-container operation, GSM remote monitoring, and power distribution cables. Mining camps and disaster recovery operators often deploy two or more containers in parallel to achieve redundancy, with fuel delivered by a bowser truck. This turnkey container package is ready for operation within hours of arriving on site, with no civil works or plant room required.
Quality Assurance and Delivery
KITOZER performs a full factory load-bank test on each 1000kW container set, testing engine, alternator, control cubicle, ventilation, fire suppression, and lighting inside the closed container. The container is then water-spray tested, acoustic tested, and CSC certified. Delivery scope includes the containerized generator, dual 24V battery banks, internal distribution panel, control manual, electrical schematic, spare filter and injector kit, and 12 months of warranty. KITOZER can bundle external fuel tank, parallel kit, GSM remote monitoring, and power distribution cables as a turnkey package, and provides CE documentation, factory test report, and commissioning support for remote power station and disaster recovery projects.
Price
From $215,000 per containerized set ex works Guangzhou. Contact KITOZER for external fuel tank, parallel kit, and remote monitoring pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com