Table of Contents
ToggleProduct Overview
The KITOZER Industrial Connector PDU with 32A rated current uses an IEC 60309 industrial plug as the input and distributes power to eight universal outlets on a rugged vertical chassis. Designed for factory floors, outdoor telecom cabinets, construction site offices, and event staging, the industrial connector input provides a weatherproof and vibration-resistant connection that ordinary IEC C20 plugs cannot match. The PDU chassis is built from heavy-gauge steel with a corrosion-resistant powder coat, and the outlets are positioned to accept both C13 and regional industrial plugs. A built-in RCD option protects personnel against earth-leakage faults in wet or dusty environments.
Technical Specifications
Input 200 to 240V AC single phase, 32A continuous. IEC 60309 2P+PE 32A input plug with 5 meter cord. Eight universal outlets. 32A thermal magnetic circuit breaker. Optional 30mA Type A RCD. Operating temperature minus 10 to 55 degrees Celsius. Chassis SPCC steel, IP40 front, optional IP54 cover. Dimensions 55 mm x 120 mm x 600 mm. Weight 2.8 kg. CE, RoHS, IEC 60309, IEC 61008. KITOZER, two-year warranty.
Applications
Industrial connector PDUs are used on factory floors powering PLC enclosures and test equipment, in outdoor telecom cabinets feeding base station radios, and on construction sites providing temporary power to tools and lighting. They are also deployed in outdoor broadcast trucks, film sets, and event staging where power must be safely connected and disconnected frequently. The IP-rated chassis survives dust, humidity, and occasional washdown that would damage standard office PDUs.
Key Advantages
The IEC 60309 input provides a secure, keyed connection that cannot be accidentally dislodged, unlike domestic plugs. The rugged chassis tolerates vibration and temperature extremes. The optional RCD adds personnel protection in wet or dusty locations. Universal outlets accept regional plugs on international job sites. The 32A rating supports higher draw than standard strips, powering multiple tools or machines from one feed. The vertical form factor fits into narrow industrial cabinets.
Installation and Maintenance
Mount the PDU on a wall or DIN rail using the included brackets. Connect the IEC 60309 plug to a suitable industrial socket. Route the cord away from walking paths and moving machinery. Test the RCD monthly using the test button. Inspect the chassis and outlets for dust and corrosion quarterly. Keep outlet covers closed when not in use to maintain IP rating. Tighten terminal screws annually. Replace the cord if insulation is damaged. The unit has no firmware, so no software maintenance is required.
Why KITOZER
KITOZER is manufactured by Guangzhou Laian Intelligent System Development Co., Ltd., a factory specializing in data center power distribution and cable support systems since the early 2000s. Every PDU and cable tray leaves the production line after 100 percent insulation testing, high-pot testing, and load verification. The engineering team supports custom outlet layouts, custom cord lengths, private labeling, and OEM projects for system integrators and distributors. Long-term spare parts availability, stable pricing, and English-speaking technical support reduce risk for international buyers who source mission-critical infrastructure. KITOZER products ship to over sixty countries and are installed in enterprise data centers, telecom sites, industrial plants, and commercial buildings.
Packaging and Lead Time
PDUs are packed in corrugated cartons with foam corners, and cable trays are bundled with steel strapping and wrapped in stretch film. Standard models ship from stock within 5 to 7 working days. Custom configurations require 15 to 25 working days depending on complexity. Delivery is arranged by sea, air, or express courier according to buyer preference. Pallet loads and full container loads are supported for project sites. Each shipment includes a packing list, test report, and installation manual in English. The sales team confirms lead time at order placement and tracks production milestones until dispatch.
Compliance and Certifications
KITOZER products carry CE and RoHS marks, and production follows ISO 9001 quality management procedures. PDUs are tested to IEC 60950 and IEC 62053 where metering is fitted. Cable trays are tested to IEC 61537 for load rating and dimensions. Full test reports, material certificates, and factory audit documents are available on request for infrastructure projects that require submittal packages. The factory supports third-party inspection before shipment for large orders.
Technical Support and Documentation
KITOZER provides English documentation for every product, including dimension drawings, wiring diagrams, installation manuals, and factory test reports. For managed PDUs, the engineering team supplies Modbus register maps, SNMP MIB files, and REST API examples to speed integration with third-party DCIM and building management platforms. For cable support systems, the factory supplies load rating tables, fitting catalogs, and BOM templates for project takeoffs and quantity estimation. Pre-sales engineering support helps buyers select the correct outlet count, current rating, cable width, and mounting style based on rack layout, load schedule, and environmental conditions. After-sales support covers commissioning guidance, firmware upgrades, and warranty claims. Spare parts such as surge modules, sensor probes, connector kits, and cover clips are stocked for fast replacement. The sales and engineering team replies to technical inquiries within one business day and supports remote video calls for complex project commissioning.
Price
From $185/pc. Contact +86 13922289957 for RCD and IP54 options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com