The KITOZER KYN28A-12 is a metal-clad withdrawable alternating current metal-enclosed switchgear panel designed for 10kV three-phase 50Hz power systems. It serves as the receiving, feeder, transformer protection, and motor control center in medium voltage distribution networks. The assembly adopts the standard mid-mounted layout where the vacuum circuit breaker truck rolls on precision rails for safe insertion and withdrawal. Fully segmented compartments separate the busbar, breaker, cable, and low-voltage control sections with steel partitions and IP2L rated shutters, so personnel can approach the front door while the busbar remains live.
The enclosure is folded from high-quality cold-rolled steel sheet and finished with epoxy polyester powder coating for long-term corrosion resistance in substations, industrial plants, and commercial building power rooms. Every panel is fitted with a pressure relief duct on the top that directs internal arc gases safely upward, protecting operators standing in front. The front door houses the protection relay, control switches, indicator lights, and a rotary hand crank for racking the breaker truck. Standard mechanical and electrical interlocks prevent incorrect operating sequences, giving maintenance crews confidence that the panel is safe to operate even under pressure.
Technical Specifications
Rated voltage 12kV, rated frequency 50Hz, rated current 630A, rated short-time withstand current 20kA for 4 seconds, rated peak withstand current 50kA, rated lightning impulse withstand voltage 75kV across phase and 85kV to earth. Internal arc protection classification IAC AFLR up to 40kA for 1 second is available as an option. Main busbar is tin-plated copper with silver-plated contacts.
Standard configuration includes VS1 (ZN63A-12) vacuum circuit breaker, microcomputer protective relay with overcurrent, earth fault, and transformer differential options, current transformer, voltage indicator, and earthing switch. Degree of protection reaches IP4X on the front and IP2X on compartment partitions. Overall dimensions are approximately 800mm wide by 1500mm deep by 2300mm high, floor standing with four mounting holes. Auxiliary supply is 110V DC or 220V AC, with shunt trip and undervoltage release as standard. A space heater and humidity controller keep the interior dry in tropical environments.
Typical Applications
This 630A rating is commonly selected for 10kV incoming and feeder circuits in medium-sized industrial plants, commercial building substations, hospital and university campus power rooms, water treatment pumping stations, and light manufacturing facilities. It is also widely used as the primary switchgear feeding 10kV/0.4kV distribution transformers in the 630kVA to 1250kVA range. Because the 630A busbar and breaker are compact, the panel fits retrofits into existing 10kV rooms where floor space is limited, and it pairs naturally with KITOZER dry-type or oil-immersed transformers to form a complete transformer feeder unit.
Other common duties include capacitor bank feeders, standby generator incomers in plants that cannot tolerate a black start, and cable interconnection panels between two 10kV substations located in the same building complex. The panel is equally suitable for urban secondary substations, industrial captive power distribution, and infrastructure projects such as tunnel ventilation, railway signaling power, and wastewater pumping stations where reliable medium voltage distribution is essential.
Key Advantages
The withdrawable truck design allows the vacuum circuit breaker to be rolled out for inspection or replacement in minutes without de-energizing the main busbar. Interlocked shutters automatically cover the live stubs when the truck is withdrawn, preventing accidental contact. Mechanical and electrical interlocks prevent incorrect operating sequences such as closing the earth switch while the cable is live or withdrawing the truck while the breaker is closed.
The front-mounted rotary actuators mimic traditional medium voltage panel operation, and the optional LCD protection relay displays current, voltage, power, and event records in plain language. KITOZER manufactures the panels under ISO 9001 quality control, with routine testing including power-frequency withstand, impulse withstand, contact resistance, and mechanical endurance performed on every unit before shipment. A five-year warranty and long-term spare parts availability give asset managers peace of mind over the full 30-year design life.
Installation and Maintenance
Install the panel on a flat concrete foundation with four M12 anchor bolts, and connect the earthing busbar to the site earthing grid with a minimum 40mm by 4mm copper strip. Reserve at least 1.5 meters of clearance in front for truck withdrawal and 0.8 meters at the rear for cable termination. After commissioning, inspect the vacuum interrupter contacts every five years or after 10,000 mechanical operations, check contact resistance annually, and test the protection relay settings with a secondary injection tester during each scheduled shutdown.
Keep the panel interior dry, and do not block the top pressure relief ducts. A space heater should be energized whenever the panel is in service. KITOZER supplies a dedicated spare-parts kit containing auxiliary contacts, heater, and control fuses with every panel. We also recommend keeping a spare VS1 breaker truck on site for critical feeders, so that a failed breaker can be exchanged without waiting for a spare to arrive from the factory.
Price
From $3,800/panel. Contact +86 13922289957 for factory quotation, protection relay option list, and lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com