Table of Contents
ToggleProduct Overview
The KITOZER PT100 temperature sensor is a platinum resistance thermometer designed for industrial process measurement where stable, traceable readings are required over a wide temperature range. Using a class A thin-film platinum element, the probe delivers plus or minus 0.15 degree C accuracy at zero degrees C and linearizes easily into PLC or transmitter inputs. The stainless steel sheath protects the sensing element from moisture, oil, and dust, making the probe suitable for pipes, tanks, ovens, and HVAC ducting. A detachable transmitter option converts the resistance signal into a standard 4 to 20 mA loop for long-distance transmission.
Technical Specifications
Element is PT100 class A per IEC 60751, measurement range -50 to 400 degrees C, optional -200 to 600 degrees C with a sintered element. Sheath is 6 mm or 8 mm stainless steel 316L, immersion length 50 to 500 mm configurable. Connection is M12 plug, DIN 43650, or terminal head. Output options include raw PT100, integrated 4 to 20 mA transmitter, or RS485 Modbus RTU. Supply 10 to 36 V DC for transmitter versions. Response time tau 63 percent is six seconds in moving water. Insulation resistance above 100 megaohms at 500 V DC.
Applications
Common uses include boiler and pipe temperature in HVAC plants, reactor and tank measurement in chemical processing, oven monitoring in food baking lines, plastic injection mold temperature, and server room cooling water loops. The PT100 is also widely used in calibration labs as a transfer standard against a reference platinum thermometer. Teams value the probe because it survives steam cleaning cycles and oily environments that defeat cheaper NTC sensors.
Key Advantages
Class A element guarantees traceable accuracy without on-site calibration. Stainless 316L sheath resists corrosion in wet and chemical environments. Integrated transmitter option eliminates signal conditioning hardware in the PLC. Wide temperature range covers both cryogenic and high-temperature processes. Five-year warranty and replacement element kits make lifetime cost predictable.
Installation And Maintenance
Insert the probe into a thermowell to protect the element during operation and allow replacement without draining the process. Torque the fitting to the recommended value to avoid leaks. Wire with three or four conductors to compensate for lead resistance; for long runs prefer the integrated 4 to 20 mA transmitter. Inspect the sheath for erosion every twelve months and recalibrate against a reference bath. Replace the element if drift exceeds the published tolerance.
From $38 per probe. Contact KITOZER for custom lengths and transmitter options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com