KITOZER Online UPS 3kVA Rack Tower Convertible For IT Closet

Product Overview

The KITOZER 3kVA online double-conversion UPS combines rack and tower convertible mounting in one compact chassis, making it one of the most flexible power protection platforms for growing IT closets, edge computing nodes, and small server rooms. Whether bolted into a 19-inch equipment rack or stood upright as a tower beside a rack, the unit delivers clean regulated sine-wave power to servers, storage arrays, switches, firewalls, and telecom gear. The online double-conversion topology ensures zero transfer time between utility and battery, protecting sensitive electronics from every class of mains anomaly including swells, sags, impulses, line-notching, and frequency drift. The rotatable front display and reversible mounting brackets make installation orientation-neutral, so the same SKU works in a wall-mounted telecom cabinet as in a floor-standing equipment corner. Hot-swappable internal battery cartridges mean runtime extension and replacement can be done without powering down the attached servers.

Technical Specifications

Rated 3kVA / 2.7kW, power factor 0.9. Input range 110 to 300VAC at 40 to 70Hz, power factor correction 0.99. Output pure sine wave 200 to 240VAC adjustable, regulation +/-2 percent, frequency 50 or 60Hz +/-0.5 percent on battery. Efficiency 94 percent online, 98 percent ECO. Internal VRLA battery 12V 9Ah x 6 strings delivers 12 minutes full-load runtime and over 40 minutes at half load. The unit occupies 3U rack space and weighs 38 kilograms. Built-in LCD with load bar, battery bar, and event log. Expansion slot for SNMP, AS400 relay, or dry-contact card. USB and RS232 standard. Operating temperature 0 to 40 degrees Celsius. CE, RoHS, IEC 62040 certified. Overload 110 percent for 10 minutes, 125 percent for 1 minute. Transfer time zero. Audible alarm 45 dB at 1 meter. Optional external battery cabinet doubles or triples runtime for sites requiring extended backup.

Application Scenarios

Typical deployments include branch office server closets hosting 2 to 4 rack servers, edge colocation PoP sites, medical imaging workstations, broadcast editing suites, and industrial automation control cabinets. The rack-tower convertible design means the same SKU fits a wall-mounted telecom cabinet in one site and a freestanding equipment corner in another, simplifying spare-parts inventory for multi-site organizations. It is also used in retail chain headquarters, school computer labs, small television studios, security operations rooms, and dental clinic server racks. Anywhere that needs clean power for 1 to 3 kilowatts of IT equipment and may later want rack mounting, this convertible chassis offers a future-proof starting point.

Advantages and Features

The online double-conversion topology removes the load entirely from the utility mains, so even severe voltage sags to 110V do not trigger battery operation. Hot-swappable internal battery modules support runtime extension and replacement without powering down the load. A wide-input PFC stage avoids unnecessary battery drain during long brownouts, preserving energy for true outages. Parallel-ready firmware allows future N plus 1 redundancy when combined with a second identical unit. Intelligent monitoring software supports safe unattended shutdown over USB or network, and email or SNMP traps alert administrators before problems escalate. The rotatable LCD reads correctly whether the unit is rack-mounted or tower-standing. A built-in maintenance bypass switch allows service personnel to isolate the UPS while keeping the load on utility power, reducing planned downtime for battery replacement or firmware upgrades.

Installation and Maintenance Recommendations

When rack-mounting, use the included sliding rail kit and distribute weight evenly across the rack. Ensure the rack can support the full chassis weight plus the external battery pack if ordered. Allow one rack unit above and below for ventilation. When tower mounting, place the unit on its included stand on a flat, level floor. Load the UPS to no more than 80 percent of rated capacity to leave headroom for future growth. Schedule battery replacement every 3 to 5 years, and keep ambient temperature below 25 degrees Celsius to double battery service life. Test the battery circuit quarterly under simulated load and retain replacement batteries on site for critical installations. Keep the area around the unit clear of cardboard, paper, and other combustible materials. Use a surge-protected input strip only if it is rated for UPS output; never daisy-chain another UPS or surge protector downstream. Document the SNMP card IP address and shutdown software credentials in the IT asset register.

Delivery and Warranty

The UPS ships in a corrugated carton with foam protection, and accessories include the power cord, USB cable, rack ears, tower stand, and quick-start guide. Standard lead time is 3 to 5 working days from stock, and bulk orders of 10 units or more ship on pallets by sea or air freight to most destinations. KITOZER provides a 2-year warranty on the power electronics and a 1-year warranty on the internal battery, with optional extended warranty up to 5 years. English-language technical support is available by email and WeChat, and remote configuration assistance via the monitoring software is offered free of charge during the warranty period.

Price

From $720/pc. Contact +86 13922289957 for rack conversion kit, external battery cabinet pricing, and lead time.