ToggleProduct Overview
The KITOZER 20kVA high-frequency online double-conversion UPS uses IGBT-based high-frequency switching topology to deliver superior power quality in a compact, energy-efficient chassis. Unlike legacy low-frequency transformered UPS designs, the high-frequency topology eliminates the bulky isolation transformer, cutting weight by 40 percent and footprint by 30 percent while raising efficiency above 95 percent. This makes the 20kVA model a popular choice for server rooms where floor space and cooling capacity are constrained but power quality cannot be compromised. The unit supports parallel redundancy up to three systems and integrates with standard SNMP and Modbus monitoring platforms, giving IT managers a single pane of glass for fleet-wide power status.
Technical Specifications
Rated 20kVA / 18kW, power factor 0.9. Input three-phase 380 to 415VAC, range 304 to 478VAC, PFC 0.99, THDi less than 3 percent. Output three-phase 380 to 415VAC, regulation +/-1 percent, THDv less than 2 percent linear, less than 4 percent nonlinear. Efficiency 95.5 percent online, 98.5 percent ECO. Internal or external VRLA battery cabinet supports 30 to 40 cells of 12V 100Ah, providing 15 to 30 minutes backup. 7-inch touchscreen, RS485 Modbus, optional SNMP and relay card. Parallel up to 3 units. Dimensions 600 x 800 x 1400 millimeters, weight 280 kilograms without batteries. CE, IEC 62040 certified. Overload 110 percent for 10 minutes, 125 percent for 1 minute. Operating temperature 0 to 40 degrees Celsius. Audible alarm 55 dB at 1 meter. The unit includes a maintenance bypass switch and fan-fault alarm.
Application Scenarios
The 20kVA high-frequency UPS suits corporate server rooms with 10 to 20 racks, dental and clinic IT systems, retail chain data closets, industrial automation PLC control rooms, and security operations centers. It is also commonly used to protect broadcasting transmitters, laboratory analytical instruments, and digital cinema projection systems where voltage distortion would damage sensitive circuits. Additional deployments include university departmental server closets, small manufacturing execution systems, and bank branch data centers. The lightweight chassis means it can be placed on upper floors or raised floors without structural reinforcement, which is a major advantage in retrofit projects.
Advantages and Features
The high-frequency topology delivers up to 95.5 percent efficiency, slashing cooling requirements and electricity bills. The lightweight chassis can be installed on raised floors or upper floors without structural reinforcement. A wide-input PFC stage rides through deep voltage sags without touching the battery, extending battery life. Intelligent battery management performs per-cell voltage monitoring and temperature-compensated charging. The parallel option supports N plus 1 redundancy for critical sites, and the maintenance bypass keeps the load powered during UPS servicing. The 7-inch color touchscreen offers multi-language menus and a clear event log, and the optional SNMP card integrates with existing DCIM software. The unit also includes a built-in input power factor correction stage that helps facilities meet grid-code requirements for harmonic emissions.
Installation and Maintenance Recommendations
Install in a clean, temperature-controlled room at 20 to 25 degrees Celsius. Keep at least 800 millimeters clearance front and rear for service. Use copper cables sized for 40 to 63A three-phase input and output. Verify upstream generator can handle the non-linear load with at least 1.5 times UPS kVA rating. Perform quarterly inspection of cooling fans and air filters. Test battery strings annually with a conductance tester and replace weak cells promptly. Upgrade firmware annually through the service port to benefit from algorithm improvements and security patches. Keep the room dust-free and away from direct sunlight. Record the initial battery capacity test baseline and compare results annually to detect gradual degradation. Label input, output, and bypass breakers clearly for safe maintenance isolation.
Delivery and Warranty
The UPS is delivered on a pallet with the touchscreen keypad, power cables, documentation, and optional external battery cabinet. Standard lead time is 3 to 5 weeks, and sea freight takes 25 to 35 days to major ports. KITOZER provides a 3-year warranty on power electronics and a 2-year warranty on batteries, with optional extended coverage up to 5 years. English technical support is available by email, WeChat, and WhatsApp, and remote monitoring configuration is included. Spare fans, control boards, and contactors are held in regional warehouses. CE certificates, factory test reports, and operating manuals are supplied in English with every unit.
Compatibility
The high-frequency UPS supports parallel operation of up to three units for N plus 1 redundancy, and the optional SNMP card integrates with leading DCIM platforms. The wide-input PFC stage works well with most standby diesel generators rated at 30kVA or above. English CE certificates, factory test reports, and operating manuals are supplied with every unit. The same chassis and control board are shared across 10kVA to 40kVA models, simplifying spare-parts logistics for multi-site customers.
Price