Table of Contents
ToggleProduct Overview
The KITOZER 2V 1000Ah gel battery is a deep-cycle valve-regulated lead-acid unit engineered for long-duration UPS backup, off-grid solar storage, and telecom central office plants where 2 to 8 hours of runtime is required. The gelled electrolyte immobilized by silica additive prevents stratification and allows deeper discharge cycles than AGM counterparts, making it ideal for installations with frequent outages or seasonal solar generation gaps. Cells are housed in transparent or opaque ABS containers with heavy-duty copper terminals for robust series and parallel arrangements. Each cell undergoes 100 percent capacity testing at the factory before shipment, and matched-cell sets are grouped to ensure string uniformity over a 15-year service life.
Technical Specifications
Nominal voltage 2V, rated capacity 1000Ah at 10-hour rate to 1.8V per cell at 25 degrees Celsius. Design float life 15 to 18 years at 25 degrees Celsius. Cycle life more than 3000 cycles at 50 percent depth of discharge. Internal resistance approximately 0.3 milli-ohms. Maximum discharge current 8000A for 1 minute. Float charging voltage 2.25 to 2.30V per cell, equalizing charge 2.35V per cell. Operating temperature -20 to 55 degrees Celsius. Dimensions 207 x 207 x 715 millimeters, weight 310 kilograms. Terminal M10 copper alloy. Complies with IEC 60896, DIN 40742, CE, and ISO 9001. Self-discharge below 2 percent per month, allowing up to 18 months storage before recharge. The recombinant valve operates at 1 to 3 psi, and the container is UL94 V-0 rated.
Application Scenarios
Typical installations include 100kVA to 500kVA UPS systems requiring 2-hour or longer battery autonomy, off-grid and hybrid solar power stations, telecom microwave towers with no grid connection, wind farm turbine control power, railway signaling, and submarine and marine backup systems. The deep-cycle robustness also fits renewable energy systems with daily cycling between charge and discharge. It is commonly specified for data centers that want 30 minutes to 2 hours of battery runtime while waiting for a diesel generator to start and take the load, and for remote monitoring stations that rely entirely on solar plus storage for weeks at a time.
Advantages and Features
Gelled electrolyte prevents acid stratification and enables up to 3000 deep discharge cycles, three times the cycle life of standard AGM. The 15 to 18 year float life reduces total cost of ownership over a 10-year facility horizon. Low self-discharge below 2 percent per month supports seasonal off-grid operation. Wide temperature tolerance from -20 to 55 degrees Celsius suits outdoor and remote cabinets. Heavy-plate construction delivers excellent recovery after deep discharge, and recombinant valves suppress gas emissions for safe indoor installation. The transparent container option lets maintenance staff inspect electrolyte level and sediment visually without opening the valve, and heavy copper terminals resist corrosion over decades of service.
Installation and Maintenance Recommendations
Place cells on a reinforced concrete floor or purpose-built steel rack designed for 400 kilograms per cell. Use insulated cell interconnect bars and torque to 25 Nm. Keep the battery room between 20 and 25 degrees Celsius; ventilation must follow local codes for VRLA installations. After commissioning, perform a full capacity discharge within 6 months to establish baseline performance. Test per-cell voltage and internal impedance every 6 months. Clean tops with a dry cloth only; never use water or solvents. Replace cells that fall more than 10 percent below string average. Because cells weigh over 300 kilograms, use a pallet jack or forklift during installation and plan two-person lifting points carefully. Keep the room dust-free and maintain adequate airflow around each cell. Do not stack cells above the manufacturer-recommended height, because bottom-cell compression can deform plates.
Delivery and Warranty
Cells are packed on heavy-duty pallets with protective corner boards, 8 to 12 cells per pallet depending on size. Standard lead time is 10 to 15 working days, and sea freight takes 30 to 40 days due to the weight. Each cell carries a 3-year free replacement warranty, with expected design life of 15 to 18 years. KITOZER supplies matched-cell sets within tight voltage tolerance for balanced strings, along with UN38.3, CE, IEC 60896 certificates, and dimensional drawings. Bulk orders for whole battery rooms are supported with project-engineered layout drawings. Interconnect bars and torque tools can be bundled with the cell order to simplify on-site installation.
Compatibility
The 2V 1000Ah cell fits standard stationary battery racks from major manufacturers and supports series strings from 24V up to 600VDC. The M10 terminal accepts standard copper interconnect bars. Matched-cell sets are grouped within tight voltage tolerance for balanced string performance. English datasheets, IEC 60896 certificates, and dimension drawings accompany every shipment. Project orders for whole battery rooms include engineered layout drawings and load calculations for the structural engineer.
Price
From $420/cell. Contact +86 13922289957 for full battery room design, rack layout, and long-run runtime calculations.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com