KITOZER
KITOZER

KITOZER ATS Automatic Transfer Switch 400A Three Phase

Product Overview

The KITOZER 400A automatic transfer switch (ATS) is a two-position switchboard that automatically alternates a critical load between utility power and backup diesel generator. Built around a reliable motorized changeover contactor and a microprocessor controller, the ATS senses utility voltage and frequency, starts the generator on failure, transfers the load, and returns to utility when normal. The cabinet is floor-standing or wall-mountable, with incoming utility and generator feeders and outgoing load feeder. KITOZER supplies the ATS pre-wired and tested, so the customer only needs to connect power cables and generator start signals.

Technical Specifications

Rated current: 400A, three phase four wire, 400V or 480V, 50Hz or 60Hz. Short-time withstand: 50kA for 1 second. Transfer mechanism: motorized changeover interlocked, no parallel between utility and generator. Controller monitors utility voltage, frequency, phase rotation, and generator voltage, with programmable transfer delay 0 to 60 seconds and generator warm-up 0 to 300 seconds. The ATS offers manual bypass handle for maintenance, LED status indicators, dry-contact remote alarms, and RS485 Modbus. Cabinet is steel, IP42, wall or floor mount, with hinged door and locking handle. Weight is about 180kg and dimensions are 800 by 400 by 1800 millimeters. Warranty is 2 years.

Applications

This 400A ATS is used in small factories, commercial buildings, hospitals, and data centers to protect critical loads from utility outages. It automatically starts the diesel generator when utility fails and transfers the load within seconds, preventing production line shutdowns, elevator stranding, and IT equipment reboot. Shopping centers and office buildings install it to keep fire pumps, emergency lighting, and HVAC fans running. Residential estate developers use it for communal water pumps and elevators. Because the ATS has a manual bypass, maintenance can be performed on the switchgear without interrupting the load. The compact cabinet can be wall-mounted in a small plant room or installed outdoors under a canopy, and the controller is simple enough for site electricians to configure without specialized training. The ATS can also be integrated with a building management system via dry contacts or Modbus, providing visibility of source status and transfer events to the central monitoring room. This makes the ATS suitable for facilities that require remote monitoring and alarm notification without a dedicated on-site operator.

Advantages and Features

KITOZER builds the ATS with electrical and mechanical interlocks that prevent utility and generator feeders from being connected simultaneously. The controller offers programmable voltage windows, transfer delay, generator warm-up, cool-down, and exercise scheduling. LED indicators show utility, generator, load, and fault status. Standard features: manual bypass handle, dry-contact alarms, RS485 Modbus, and phase rotation protection. Optional items include Ethernet, GSM remote monitoring, surge protection, and power monitoring meter. The cabinet is compact and can be installed in a small plant room or outdoors under a canopy. KITOZER provides commissioning support and a 2-year warranty.

Installation and Maintenance Recommendations

Install the ATS on a level wall or plinth, with 500mm clearance on front for door swing and cable termination. Connect utility incoming, generator incoming, and outgoing load with copper cables sized for 400A. Verify phase rotation on both incoming feeders before energizing. Configure the controller with utility voltage window, transfer delay, generator warm-up, and exercise schedule. Test automatic transfer by simulating utility failure, and verify the generator starts, stabilizes, and closes the load contactor. Maintenance: contactor inspection annually, spring mechanism lubrication every 2 years, controller battery replacement every 3 years, and manual bypass operation test annually. Keep the cabinet door closed to prevent dust and moisture ingress, and verify alarm contacts are wired to the building management system.

Typical Customer Configuration

A common KITOZER ATS configuration pairs the 400A panel with a 400kW diesel generator, a building management system dry-contact alarm, and a GSM remote monitoring module. Small factories, commercial buildings, and clinics use this setup to achieve fully automatic transfer between utility and generator, with the monitoring module sending SMS alerts for transfer events or faults. The manual bypass handle allows maintenance on the ATS without interrupting the load, reducing planned downtime.

Quality Assurance and Delivery

KITOZER tests every 400A ATS panel in the factory, verifying contactor mechanical and electrical interlocks, voltage sensing, transfer timing, manual bypass operation, and dry-contact alarm outputs. The panel is then wired, labeled, and packaged for export. Delivery scope includes the ATS panel, control manual, wiring diagram, spare contactor kit, and 2 years of warranty. KITOZER can supply custom current ratings, surge protection, Ethernet or GSM remote monitoring, and power monitoring meter as options. CE documentation, type test report, and on-site commissioning support are available for commercial building and industrial projects.

Price

From $2,480 per ATS panel ex works Guangzhou. Contact KITOZER for custom current rating, remote monitoring, and commissioning support.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart