KITOZER In Row Air Conditioner 15kW Rear Discharge For Server Row

KITOZER 15kW in-row air conditioner provides close-coupled cooling for medium-density server rows, delivering conditioned air directly where it is needed. The rear-discharge configuration draws hot exhaust from the hot aisle and supplies cold air through the front, mirroring the airflow direction of standard server racks. This symmetry simplifies hot-aisle containment and ensures every rack receives adequate supply air without relying on perforated floor tiles.

Product Overview

The unit uses an inverter-driven compressor that modulates capacity from 20 to 100 percent, avoiding short cycling and improving efficiency at part load. EC fans adjust speed based on static pressure setpoint. The controller supports group control, allowing up to 16 in-row units to coordinate operation, rotate runtime, and share alarms. A built-in leak detection sensor alerts on condensate or refrigerant leaks.

Technical Specifications

Cooling capacity 15kW nominal. Airflow 3800 cubic meters per hour. Power supply 380V 3Ph 50Hz. Inverter compressor. Cabinet width 300 millimeters, depth 1200 millimeters, height 2000 millimeters. Operating ambient 18 to 35 degrees Celsius. Noise below 65 dBA. Modbus TCP, SNMP. CE certified. KITOZER brand. Five year warranty.

Applications

Typical uses include enterprise server rooms with 8 to 12kW per rack, private cloud deployments, AI training clusters with mixed densities, and branch office data closets. The unit works in both new construction and retrofit projects where room-based cooling has created hot spots. It also suits colocation halls that offer custom-density zones.

Advantages

Inverter modulation saves energy at partial load. Group control balances runtime across units. Front-to-back airflow matches server rack direction. Compact footprint preserves rack count. Remote monitoring supports unmanned operation. The unit can be added without shutting down the IT row if refrigerant services are pre-routed.

Installation and Maintenance

Install the unit in the row with equal spacing between rack groups. Ensure condenser airflow is unobstructed. Set group control address via dip switch. Replace the air filter every quarter. Inspect condensate drain monthly. Calibrate temperature sensor annually. Keep firmware updates available for remote patching.

Price: From $6,800/pc. Contact +86 13922289957 for 15kW in-row AC price.