Table of Contents
ToggleProduct Overview
KITOZER 80 dB RF shielding room is a high-performance screened enclosure intended for wireless product validation, antenna pattern measurement, and radio coexistence testing where ambient base-station and Wi-Fi leakage would otherwise corrupt instrumentation readings. The room uses double-wall welded steel construction with a dual-layer copper-foil interface at every joint, giving measured attenuation of 80 dB from 10 kHz to 40 GHz. A motorized sliding shield door with pneumatic pressure seal provides operator-friendly access, while a broad portfolio of filtered and waveguide penetrations supports power, Ethernet, USB, HDMI, and fiber feeds without compromising isolation. The enclosure can be lined internally with ferrite tiles and pyramidal absorber to convert it into a compact semi-anechoic chamber when required.
Technical Specifications
Internal dimensions are 5.0 m wide by 6.0 m deep by 3.0 m high, with 2.0 mm welded steel skins on both inner and outer shells and a continuous 0.1 mm copper-foil interlayer. Shielding effectiveness per IEEE 299 is 100 dB electric field from 10 kHz to 30 MHz, 90 dB magnetic field up to 1 MHz, and 80 dB plane wave and microwave from 1 GHz to 40 GHz. The motorized door is 1.2 m by 2.0 m and closes with a perimeter beryllium-copper finger strip plus a continuous silicone seal. Penetration panels include a 32 A three-phase power filter (100 dB attenuation), four Cat 6e data filters, two SMA bulkhead adapters, and a 400 mm honeycomb exhaust blower with filtered return. Lighting, internal workbench, and 100 mm ground bus bar are factory fitted.
Application Scenarios
This RF chamber is deployed by wireless module makers, smartphone accessory brands, IoT gateway manufacturers, and automotive telematics suppliers for radiated transmitter power verification, receiver sensitivity desense work, and Bluetooth, Zigbee, UWB, and 5G NR band testing. It is also used by security integrators who need a controlled space to characterize eavesdropping resistance and by research groups working on novel antenna arrays. The double-wall design suppresses both conducted and radiated coupling, so sensitive spectrum analyzers and VNA equipment can be installed inside without external interference. When absorber-lined, the room supports 3 m and 5 m far-field pre-compliance measurements to CISPR and EN standards.
Advantages and Features
The double-wall construction with copper interlayer is the key differentiator: it delivers 80 dB plus isolation up to 40 GHz without the cost and schedule risk of a fully welded on-site shield room. The modular penetration panel lets lab managers reconfigure cable feeds as test scope evolves. Motorized door operation reduces operator fatigue and guarantees consistent closure pressure, which directly preserves long-term shielding performance. KITOZER supplies the room with a third-party attenuation certificate and offers turnkey absorber lining, turntable, and antenna mast integration so customers receive a single-vendor test cell. Remote monitoring via a door-status contact and filter temperature alarm ties the room into the lab building management system.
Installation and Maintenance Recommendations
Install the chamber on a dedicated isolated concrete foundation separated from the building floor by a 50 mm foam expansion joint to avoid structural-borne vibration coupling. Bond the room earth bar to the facility grounding grid with two parallel 25 mm squared copper straps. During commissioning, perform a full IEEE 299 shielding survey and archive the baseline. Quarterly, inspect door finger strips for compression set, and verify door interlock safety circuit operation. Annually, measure insertion loss on each mains and data filter using a current probe and spectrum analyzer; replace any unit that has dropped below 60 dB. Keep the interior dry, control humidity below 60 percent, and avoid touching copper surfaces to prevent oxidation.
Configuration and Options
KITOZER configures each 80 dB RF chamber around the customer test scope. The base package includes the double-wall shell, motorized door, 32 A three-phase filter, four Cat6e bulkheads, two SMA panels, and a single 400 mm honeycomb exhaust. Optional add-ons cover a full ferrite-tile and pyramid absorber lining for compact semi-anechoic use, a 3-axis DUT positioner, a 2.5 m antenna mast, fiber-optic rotary joint for rotating measurements, and a shielded equipment control room with viewing window. Customers testing 5G FR2 or satellite bands can extend shielding to 67 GHz with upgraded waveguide and gasket materials. KITOZER also supplies a turnkey test automation package with chamber control software that coordinates door interlocks, turntable, mast, and instrument drivers. When ordering, provide the DUT dimensions, frequency range, antenna height, and required quiet zone, and KITOZER will return a layout drawing and attenuation budget for review.
Warranty and Support
KITOZER provides a five-year warranty on the chamber shield and a two-year warranty on door, filters, and absorber tiles. A factory attenuation certificate ships with each chamber, and on-site commissioning support is available. Spare absorber panels, filters, and finger strips are stocked for fast replacement.
Price
From $46,000 per chamber. Contact +86 13922289957 for tailored chamber layout and absorber lining options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com