KITOZER KYN28A-12 10kV 1250A Mid-Mounted Switchgear

Product Overview

The KITOZER KYN28A-12 rated at 1250A is a higher-capacity variant of the classic mid-mounted 10kV switchgear family, built to feed larger transformers and heavy industrial loads. The cabinet uses the same proven steel-enclosed withdrawable structure, but the busbar system and primary contacts are uprated to carry continuous 1250A with low temperature rise. A VS1-12/1250-31.5 vacuum circuit breaker with 31.5kA short-time withstand is fitted as standard, giving the panel enough breaking duty for industrial plants with high fault levels.

The front door houses the protection relay, control switches, and status indicators, while the rear cable compartment accommodates up to three single-core XLPE cables per phase. Cable sockets are shielded and touch-proof, and an earthing switch inside the cable compartment provides a safe earth point during maintenance. The panel is fully type-tested to IEC 62271-200 and supports internal arc classification options for installations where personnel may be present in front of the switchgear during a fault.

Technical Specifications

Rated voltage 12kV, rated current 1250A, rated frequency 50Hz, rated short-time withstand current 31.5kA for 4 seconds, rated peak withstand current 80kA, rated normal current of the busbar 1250A, rated lightning impulse withstand voltage 75kV phase-to-phase and 85kV phase-to-earth. Vacuum interrupter breaking current 31.5kA, mechanical endurance 10,000 operations, electrical endurance 50 rated short-circuit breaking operations.

Auxiliary supply 110V DC or 220V AC, undervoltage release and shunt trip included. IP4X front, IP2X partitions, optional IAC internal arc 40kA 1s. Cabinet width 1000mm, depth 1660mm, height 2300mm. Main busbar is doubly laminated tin-plated copper to keep temperature rise below 65K at rated current. A built-in space heater, humidity controller, and cable compartment light are included. Optional Modbus TCP or Profibus communication module allows remote monitoring of current, voltage, breaker position, and fault events.

Typical Applications

At 1250A this panel is the workhorse for 10kV feeders serving 1600kVA to 2500kVA transformers in data centers, semiconductor fabs, automobile manufacturing plants, mining processing facilities, and large commercial shopping malls. It is also selected for 10kV incoming panels in secondary substations where two transformers are paralleled through bus-tie breakers. The panel works equally well for capacitor bank feeders, motor feeders driving large 10kV pumps and fans, and standby generator incomers in plants that cannot tolerate a black start.

In data center projects, the 1250A panel typically forms the 10kV side of a 2N redundant distribution system, with two incomer panels and one bus-tie panel feeding redundant UPS and transformer pairs. In industrial plants, it is used as the main 10kV switchboard feeding several outgoing feeder panels that in turn supply process motors, HVAC chillers, and emergency power systems. The 31.5kA breaking capacity makes the panel suitable for connection to urban utility networks where fault levels can exceed 25kA.

Key Advantages

The 31.5kA breaking capacity ensures the panel can clear high fault currents typical of urban load pockets. The withdrawable design means the breaker truck can be exchanged with a spare in under ten minutes, minimizing unplanned downtime. Copper busbar is heavily silver-plated at joints to keep contact temperature rise below the IEC 62271-200 limit of 65K above ambient.

A comprehensive mechanical interlock chain prevents the truck from being withdrawn while the breaker is closed, prevents closing the earth switch on a live cable, and prevents opening the rear cable door while the cable compartment is energized. Optional microcomputer relay with Modbus TCP allows remote SCADA monitoring of current, voltage, trip events, and breaker wear count. KITOZER factory performs full type-test equivalent routine tests including 1-minute power-frequency withstand at 42kV and impulse testing at 75kV on every panel, so each unit ships with a certified test report.

Installation and Maintenance

Set the panel on a steel channel base frame anchored to the foundation, and bolt the earthing busbar to the station earth. Keep 20mm clearance between adjacent panels for busbar expansion. Cable termination should be performed by trained personnel using heat-shrink or cold-shrink terminations rated for 12kV. During the first year of service, inspect the breaker truck rollers and contact fingers every six months, thereafter inspect annually.

Lubricate the racking screw with lithium grease and check the vacuum interrupter pressure by observing the UV indicator window every three years. KITOZER recommends annual secondary injection tests of the protection relay and a five-year major overhaul of the spring operating mechanism. Keep a spare breaker truck on site for critical feeders, and store it in a dry room with silica gel to prevent corrosion on the contact fingers.

Price

From $4,500/panel. Contact +86 13922289957 for 1250A switchgear pricing and protection scheme options.