KITOZER
KITOZER

KITOZER SVG-10Mvar 10kV Static Var Generator

Product Overview

The KITOZER SVG-10Mvar is a 10kV static synchronous compensator based on cascaded H-bridge IGBT topology. It continuously injects or absorbs reactive power in milliseconds to hold the 10kV busbar voltage stable and correct power factor to 0.99 leading or lagging. Unlike traditional switched capacitor banks, the SVG delivers smooth step-less compensation and can also absorb leading reactive power when the load is light, preventing over-voltage at the end of long feeders.

Technical Specifications

Rated voltage 10kV, three phase 50Hz, rated reactive power 10Mvar continuously over full range from minus 10Mvar to plus 10Mvar. Response time less than 10 milliseconds. IGBT-based cascaded H-bridge, each cell 690V. Losses below 2 percent. Cooling: forced air. THD of output current below 3 percent. Communication: Modbus TCP, IEC 61850 option. Cabinet floor standing, IP31. Operating temperature minus 10 to 45 degrees C. Efficiency above 97 percent.

Typical Applications

SVG-10Mvar is installed at the 10kV bus of industrial plants with rapidly fluctuating loads such as arc furnaces, welders, rolling mills, and mine hoists. It is also used at wind and solar farm grid connection points to meet grid-code voltage and power factor requirements. In urban substations, the SVG supports voltage support during peak load and prevents over-voltage during light load.

Key Advantages

Step-less compensation means no switching transients and no risk of resonance with the system impedance. The SVG can both generate and absorb reactive power, so it handles both lagging and leading load conditions. Response in under 10 milliseconds suppresses flicker caused by welders and arc furnaces. Modular power cells allow individual cell replacement without shutting down the whole SVG. KITOZER supplies a SCADA view showing instantaneous reactive power, voltage, and cell status.

Installation and Maintenance

Install the SVG cabinets in a clean, ventilated room with ambient temperature below 40 degrees C. Connect the 10kV feeder through a dedicated breaker with the SVG control interlocked. Keep the intake filters clean and replace them every six months. Every year, inspect the IGBT cell capacitors, check the cooling fan bearings, and run the self-diagnostic routine. Individual power cells can be exchanged in under 30 minutes using the built-in bypass switch, so maintenance does not require a long outage.

Price

From $68,000/cabinet set. Contact +86 13922289957 for SVG sizing and quotation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top