Table of Contents
ToggleProduct Overview
Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER) offers comprehensive intelligent integration for machine room power distribution, covering the entire chain from utility input to terminal racks. Our solutions integrate high/low voltage distribution, UPS, battery banks, precision distribution, lightning protection, and energy management to ensure stable, safe, and efficient power supply for data centers and machine rooms.
Product Introduction
The intelligent machine room power distribution integration is a complete power supply and distribution solution tailored for machine room environments. It encompasses the design, equipment supply, construction installation, and intelligent management of the entire power distribution chain—from mains power introduction to terminal racks. The system integrates high/low voltage power distribution, UPS uninterruptible power supply, battery banks, precision power distribution, lightning protection, grounding, and electrical energy management. This achieves high reliability, refined monitoring, intelligent management, and energy efficiency optimization, providing stable, safe, and efficient power assurance for machine room equipment.
Product Positioning
This product is positioned as the core power support system for machine room infrastructure. It adapts to various small, medium, and large machine rooms and data center scenarios, designed according to Class A/B machine room power supply standards. It serves as the core guarantee for stable machine room operation, offering clients an integrated power distribution service from high voltage to low voltage, and from power supply to monitoring.
Core Value
- High Reliability Power Supply: Redundant architecture design ensures power supply continuity, supporting uninterrupted business operations.
- Refined Management: Full-chain power monitoring provides insight into the power consumption of each load circuit.
- Safety Protection: Multi-level lightning protection, overload protection, and leakage protection safeguard equipment and personnel.
- Energy Efficiency Optimization: Energy consumption statistics and analysis identify waste, reducing machine room electricity costs.
- Intelligent Operation and Maintenance: Remote monitoring and fault early warning reduce the workload of power distribution O&M.
Product Highlights
- Full-Chain Integration: Integrated design and construction from mains power to rack PDU.
- Intelligent Monitoring: Complete power data collection, power quality analysis, and early fault warning.
- Redundant Reliability: Dual mains power, UPS redundancy, and diesel generator backup provide multi-level redundancy.
- Safety Compliance: Meets power supply and distribution specifications and machine room standards; lightning protection and grounding comply with regulations.
- Flexible Expansion: Modular power distribution architecture supports future load expansion and upgrades.
Product Classification and Composition
Product Classification
- By power supply level: Class A redundant distribution system, Class B dual-circuit distribution system, Class C basic distribution system.
- By distribution segment: high-voltage distribution integration, low-voltage distribution integration, UPS distribution integration, and terminal precision distribution.
- By scenario: data center distribution system, enterprise machine room distribution system, edge site distribution system.
System Composition
- High-Voltage Distribution System: High-voltage switchgear, transformers, high-voltage metering (as needed).
- Low-Voltage Distribution System: Low-voltage incoming cabinets, bus tie cabinets, feeder cabinets, capacitor compensation cabinets.
- UPS Uninterruptible Power Supply System: UPS host, battery banks, battery cabinets, bypass cabinets.
- Backup Power System: Diesel generator set, automatic transfer switch (ATS).
- Precision Distribution System: Rack-level power distribution cabinets, intelligent PDUs, branch monitoring modules.
- Lightning Protection and Grounding System: Class B/C/D surge protectors, equipotential grounding, grounding grid.
- Power Distribution Monitoring System: Power monitoring instruments, energy management platform, energy consumption analysis system.
- Cable and Busbar System: Power cables, busbar trunking, cable tray and conduit.
System Principle
The intelligent machine room power distribution integration follows the core design principles of “safety, reliability, efficiency, and intelligence.” It adopts a hierarchical distribution architecture: mains power is delivered through high/low voltage distribution to the UPS system, which outputs stable uninterruptible power to each row-level distribution cabinet, then distributes to each rack PDU to supply power to servers and network equipment. Intelligent monitoring devices on each distribution circuit collect voltage, current, power, energy, harmonics, and other electrical parameters in real time, uploading them to the energy management platform. This enables visualization of distribution status, energy consumption statistical analysis, fault early warning, and remote control. Additionally, multi-level lightning protection and protective devices are configured to withstand surges, overloads, short circuits, and other risks, ensuring the continuous and stable operation of the entire power distribution system.
Technical Specifications
| Parameter | Technical Indicator | Remarks |
| — | — | — |
| Power Supply Reliability | Class A: 99.995%; Class B: 99.99%; Class C: 99.9% | Corresponding to annual outage duration |
| Voltage Accuracy | UPS output voltage accuracy ±1% | Under steady state |
| Frequency Accuracy | ±0.1Hz | In battery mode |
| Transfer Time | Mains/battery transfer 0ms | Online double conversion |
| Monitoring Accuracy | Power monitoring accuracy 0.5 grade | Complying with national standard |
| Lightning Protection Level | B+C+D three levels | Surge protection |
| Grounding Resistance | ≤1Ω | Combined grounding system |
| Harmonic Suppression | Input current harmonic ≤3% | Online UPS |
| Battery Backup Time | 0.5h/1h/2h/4h options | Configured as needed |
Product Configuration List
| No. | Product Name | Specifications | Unit | Quantity | Remarks |
| — | — | — | — | — | — |
| 1 | Low-voltage distribution cabinet | GCS type, incoming/outgoing/bus tie, customized per requirement | Panel | As needed | 3C certified |
| 2 | UPS uninterruptible power supply | 10-200kVA, online double conversion | Unit | As needed | N/N+1/2N architecture |
| 3 | Valve-regulated lead-acid battery | 12V/100Ah/150Ah/200Ah | Cells | As needed | Maintenance-free |
| 4 | ATS automatic transfer switch | 100-1600A, PC level | Unit | As needed | Dual-circuit transfer |
| 5 | Precision row-level cabinet | Intelligent type, branch current monitoring | Panel | As needed | 1 per row |
| 6 | Intelligent PDU | 8/12 outlets, current and voltage monitoring | Strip | As needed | 1-2 per rack |
| 7 | Surge protector | Class B/C/D, three-phase power protection | Set | As needed | Multi-level protection |
| 8 | Power monitoring instrument | Multifunctional power meter, RS485 communication | Unit | As needed | For each circuit |
| 9 | Energy management platform | Web version, energy analysis, alarms | Set | 1 | Software license |
| 10 | Grounding materials | Copper busbar, grounding electrodes, grounding wire | Set | 1 | Combined grounding |
Materials & Craft Analysis
Material Details
- Distribution cabinet enclosure: Made of 1.5-2.0mm thick cold-rolled steel, electrostatic powder coating, protection rating IP30, sturdy structure, anti-corrosion.
- Distribution components: Selected first-line brand circuit breakers, contactors, relays with high breaking capacity, stable and reliable performance.
- Busbar copper: T2 red copper busbar, tin-plated, high conductivity, low contact resistance, oxidation and corrosion resistance.
- Battery: Valve-regulated sealed lead-acid battery, maintenance-free, good deep-cycle performance, long service life.
- Cables: Low-smoke halogen-free flame-retardant power cables, copper conductor, good insulation, compliant with fire safety requirements.
Core Craftsmanship
- Copper busbar processing: CNC bending, punching, tinning treatment, tight connection, low contact resistance, preventing heating.
- Cabinet wiring: Separation of strong and weak currents, neat routing, clear labeling for easy maintenance.
- Grounding process: Combined grounding grid construction, equipotential connection, multi-point grounding to ensure grounding resistance compliance.
- Welding process: Exothermic welding for grounding grid, firm joints, good conductivity, corrosion resistance.
- Commissioning: Professional electrician commissioning, including phase sequence testing, insulation testing, and load testing to ensure system safety.
Safety Certifications
- 3C certification for low-voltage complete equipment.
- TLC (Telecommunication) certification / 3C certification for UPS products.
- ISO9001 quality management system certification.
- Safety production license.
- Electric power engineering construction qualification and electronic & intelligent engineering qualification.
Core Advantages
Material Advantage
Core distribution components are selected from top international and domestic brands. Copper busbars and cables use high-quality national standard materials. All materials come with qualified inspection reports, ensuring the safety and reliability of the power distribution system.
Craftsmanship Advantage
Professional certified electricians carry out the construction strictly in accordance with power distribution regulations, with uniform process standards. A three-level quality inspection system ensures each process is accepted, eliminating potential hazards and ensuring electrical safety.
Customization Advantage
We can customize power distribution solutions based on machine room load, power supply level, and expansion needs. Support for architecture selection, brand selection, and functional module customization, adapting to machine rooms of different scales and grades.
Cost Advantage
Direct sourcing of distribution equipment and integrated design and construction reduce intermediate links. Optimized design controls costs while ensuring power supply reliability, offering high cost-effectiveness.
Quality Advantage
The system design complies with national power supply and distribution specifications and machine room construction standards. Comprehensive testing is conducted before delivery to ensure safety and stability. We provide long-term warranty and operation & maintenance services to ensure long-term reliable operation.
Product Category Details
- Class A machine room 2N redundant power distribution system: Dual mains + dual UPS redundancy, highest power supply reliability, suitable for core data centers.
- Class B machine room N+1 power distribution system: Dual mains + UPS redundancy, high reliability, suitable for enterprise core machine rooms.
- Class C machine room basic power distribution system: Single mains + UPS backup, meets basic needs, suitable for small machine rooms.
- Intelligent precision power distribution system: Full-branch refined monitoring, energy management, suitable for medium and large machine rooms.
- Diesel generator backup power distribution system: Extended backup time, suitable for remote scenarios without mains guarantee.
SKU Attributes
| SKU Code | Product Name | Capacity Range | Power Supply Level | Applicable Scenario |
| — | — | — | — | — |
| LA-PD-001 | Small machine room power distribution system | ≤20kVA | Class C | Micro/small machine room |
| LA-PD-002 | Medium machine room power distribution system | 20-100kVA | Class B | Medium enterprise machine room |
| LA-PD-003 | Large machine room power distribution system | 100-500kVA | Class B/A | Large data center |
| LA-PD-004 | Precision power distribution system | Customized | – | Machine room terminal distribution |
| LA-PD-005 | Generator backup power distribution system | 50-1000kW | Class A | High-reliability scenarios |
Stock Details
- Regular specifications of UPS, batteries, PDUs, small distribution cabinets are in stock.
- Standard distribution products ship within 3 days; custom distribution cabinets are produced according to lead time.
- Sufficient inventory of common distribution accessories and components ensures after-sales and renovation needs.
- Urgent orders can be prioritized to meet project emergency requirements.
OEM and Confidentiality
- Provide OEM supporting services for power distribution systems, supporting OEM labeling for distribution cabinets and UPS.
- Neutral packaging is available without manufacturer branding, meeting integrator and channel partner needs.
- Sign confidentiality agreements to protect customer project and business information.
- Cooperate with customer project bidding and technical support to ensure project success.
Application Scenarios
- Financial data centers, securities machine rooms, bank machine rooms
- Government cloud machine rooms, government and enterprise core machine rooms
- Hospital information machine rooms, CDC machine rooms
- University data centers, campus network machine rooms
- Telecom operator communication machine rooms, 5G core machine rooms
- Industrial control machine rooms, smart manufacturing power distribution rooms
- Enterprise headquarters machine rooms, R&D center machine rooms
Customization Service
Customization Scope
- Capacity customization: Customize distribution capacity and UPS capacity based on load power.
- Architecture customization: Choose N, N+1, or 2N redundant architectures as needed.
- Function customization: Add intelligent monitoring, energy management, harmonic treatment, and other functions.
- Brand customization: Support designated distribution equipment and UPS brand models.
- Scenario customization: Adapt to explosion-proof, outdoor, high-altitude, and other special environments.
Customization Process
- Requirement communication: Understand load conditions, power supply requirements, backup time, and budget.
- Solution design: Provide distribution system design, configuration list, system diagram, and quotation.
- Solution confirmation: Communicate and adjust the solution, confirm technical parameters and cost.
- Detailed design: Provide construction drawings and layout plans.
- Production and construction: Equipment production and on-site installation and wiring.
- Commissioning and acceptance: System commissioning, insulation testing, load testing, and customer acceptance.
- Delivery and O&M: Deliver completion documents and enter the warranty period.
Customization Advantages
- Professional electrical engineers provide one-on-one design, ensuring solutions are compliant and reasonable.
- Flexible adaptation to different loads and scenario needs, tailoring the optimal solution.
- Full-process service, one-stop solution from design to acceptance.
- Quick response, providing an initial solution within 24 hours.
Success Cases
Cooperation Clients
- Power distribution project for a provincial branch data center of a state-owned bank.
- Government cloud machine room power distribution system.
- Information machine room power distribution renovation for a tertiary hospital.
- Industrial control machine room power distribution for a large manufacturing enterprise.
- University campus network data center power distribution project.
Case Highlights
- Bank data center project: Adopted 2N redundant UPS power distribution architecture, achieving 99.995% power supply reliability, with zero power failures over 4 years of continuous operation, and passed Level-3 security protection assessment.
- Government cloud machine room project: Intelligent power distribution integration with full-chain energy monitoring, achieving 15% annual electricity savings after energy efficiency optimization, and realizing intelligent power distribution management.
- Hospital machine room renovation: Online renovation of the power distribution system without machine shutdown, zero business interruption, improved power supply redundancy, and ensured continuity of medical services.
Fault Handling Methods
| Fault Type | Troubleshooting Steps | Handling Method |
| — | — | — |
| Mains interruption | 1. Check mains input voltage; 2. Confirm UPS switches to battery; 3. Check ATS switching status. | 1. UPS automatically runs on battery, contact power supplier to confirm recovery time; 2. Start generator if backup time is insufficient; 3. If ATS fails, switch manually. |
| UPS alarm | 1. View alarm code; 2. Check battery voltage and mains input; 3. Check load conditions. | 1. Locate fault based on alarm code; 2. Restore mains, check battery bank; 3. Reduce overload, inspect faulty module. |
| Circuit breaker trip | 1. Check if load is overloaded; 2. Check if circuit is short-circuited; 3. Check breaker itself. | 1. Reduce load then close; 2. Find and repair short circuit, then close; 3. Replace breaker if damaged. |
| No data on distribution monitoring | 1. Check meter power supply; 2. Check communication wiring; 3. Check monitoring platform. | 1. Restore meter power; 2. Repair communication lines; 3. Restart monitoring platform and reconfigure communication. |
Maintenance
Weekly Inspection
- Inspect distribution cabinets and UPS operation status, record voltage and current parameters.
- Check for abnormal noise, odor, or heating.
- View monitoring platform alarms to confirm system normal operation.
- Inspect battery appearance for bulging or leakage.
Quarterly Maintenance
- Tighten distribution terminals, identify loose or hot points.
- Clean dust inside distribution cabinets and UPS.
- Conduct UPS battery bank voltage inspection and record individual cell voltages.
- Check surge protector status and confirm failure indication.
- Simulate mains interruption to test UPS transfer function.
Annual Deep Maintenance
- Perform infrared thermal imaging inspection of the power distribution system to identify hot spots.
- Conduct full-load UPS testing and battery capacity discharge testing.
- Test circuit breaker operation and replace aging components.
- Test grounding resistance and verify lightning protection performance.
- Calibrate power distribution monitoring system and verify data.
Factory Strength and After-sales Service
Factory Strength
- Possesses low-voltage complete equipment production capability with 3C certification.
- Professional electrical design and construction team with certified personnel and rich experience.
- Cooperates with first-line distribution brands, ensuring authentic sourcing and quality.
- Completed over a thousand machine room power distribution projects, familiar with various scenario requirements.
After-sales Service
- 7*24-hour emergency response, prioritizing power fault handling.
- 1-year overall system warranty, core equipment warranty per manufacturer standards.
- Free on-site repair during warranty, free replacement of accessories for non-human failures.
- Provide regular inspection and maintenance services to ensure system stability.
- Offer operation and maintenance training to guide customers in daily operations and simple fault handling.
Procurement Service Guarantees
Supply Guarantee
We have in-house complete equipment production capability and authorized cooperation with core brands, ensuring stable supply. Commonly used products are in stock, and customized products are delivered on schedule to guarantee project progress.
Quality Guarantee
All equipment meets national standards with proper certifications. Construction strictly follows electrical codes, and comprehensive insulation and load tests are conducted before delivery to ensure electrical safety.
Logistics Guarantee
Professional logistics ensures safe transport of large equipment via dedicated trucks. We support door-to-door delivery and on-site unloading for convenience.
After-sales Guarantee
Our professional electrical engineer team responds quickly to faults. Free maintenance during warranty, long-term technical support and spare parts supply ensure long-term reliable operation of the distribution system.
Invoice Guarantee
We can issue 13% equipment invoices and 9% engineering invoices, both VAT special invoices, with standard content to meet financial settlement requirements.
FAQ
Q: How long should the UPS backup time be configured for a machine room?
A: Regular machine rooms typically configure 0.5-2 hours, core machine rooms can configure 2-4 hours, and scenarios with diesel generators can appropriately shorten the time. It is customized based on specific requirements.
Q: What is the difference between dual mains power and UPS redundancy?
A: Dual mains power refers to two different mains inputs, ensuring that if one mains fails, the other supplies power. UPS redundancy ensures continuous power supply when mains completely fails. Combining both provides multi-level power supply protection.
Q: Can the power distribution system be connected to an environment monitoring system?
A: Yes, our intelligent power distribution integration supports interfacing with environment monitoring platforms, enabling unified monitoring, alarms, and integrated management of power distribution data.
Q: Can a machine room power distribution renovation be done without shutdown?
A: Under redundant power supply conditions, it is possible to carry out online renovation without stopping business. The specific plan needs to be assessed based on on-site conditions.
Contact Information
Company Name: Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER)
Contact: Mr. Zhou, 13538869979 (WhatsApp available), 13538869979 (WhatsApp available)
Address: Zhongrun Industrial Park, Chaotian Area, No.5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
Conclusion
Guangzhou Lain Intelligent System Development Co., Ltd. focuses on the field of machine room intelligent infrastructure. With professional technology, high-quality products, standardized construction, and comprehensive services, we provide customers with integrated machine room solutions across the full scenario and lifecycle. We adhere to the principle of “Quality First, Customer Supreme,” helping clients across industries build safe, reliable, efficient, and intelligent machine room infrastructure to ensure stable business operation.