Plain Sheet-Metal Ducts for Server-Room Air Supply? Noise Bleeds Through, Condensation Drips

Plain Sheet-Metal Ducts for Server-Room Air Supply? Noise Bleeds Through, Condensation Drips, Cold Air Short-Circuits

Many server rooms reuse leftover site ductwork for fresh air and precision-AC supply – no insulation, no silencer – only to hear the neighboring duty room hum at 70 dB, see condensation drip off summer ductwork, and watch hot/cold air short-circuit inside the duct so rack inlet temperatures swing wildly. KITOZER offers three supply-duct tiers: DUCT100 plain galvanized steel, DUCT200 flanged insulated duct, and DUCT300 silenced duct with plenum. For a 30 m main run, reference price starts at about USD 4,500.

KITOZER data center supply air duct galvanized steel flanged insulated silenced duct plenum box
KITOZER data-center supply-air duct (galvanized / flanged insulated / silenced with plenum, three tiers)

DUCT100 Galvanized-Steel Duct: Standard Ventilation

0.75-1.2 mm galvanized steel (gauge by duct size), angle-iron flange with bolted joints, sealed seams, leakage rate <=5%. For fresh-air make-up and mechanical exhaust branches where noise and insulation are not critical. Ships with manual volume-dampers, fire dampers and flexible connectors, built to GB 50243 HVAC acceptance spec. Best cost-performance.

DUCT200 Flanged Insulated Duct: Precision-AC Supply/Return

For precision-AC main supply and return. Inner galvanized-steel duct wrapped in 25 mm B1-rated rubber-plastic insulation (lambda <=0.034 W/(m.K)) with aluminum-foil outer jacket; flange faces get closed-cell foam gaskets to fully break the thermal bridge. Outer skin stays within 2 C of room temperature - no condensation. Ships with double-insulated flexible connectors, motorized dampers and pressure taps; cold-air delivery loss drops by 20%+ vs bare duct.

DUCT300 Silenced Duct with Plenum: Low-Noise Room

For rooms next to offices, duty rooms, recording/NOC centers. Builds on DUCT200: inner duct lined with 50 mm centrifugal-glasswool (wrapped in fiberglass cloth), key nodes get dissipative-reactive silencers; terminal boxes are galvanized-steel plenums lined with acoustic wool and fitted with flow spreaders. Fan and duct regenerated noise held to NC-40, and adjacent duty-room noise to <=50 dB(A) - quiet enough for night work.

Core Specs & Reference Price (30 m Main Run)

Model Key Spec Use Case EXW Price (USD/m)
KITOZER-DUCT100 0.75-1.2mm galvanized steel, angle flange, leakage<=5%, dampers/fire damper/flex conn Fresh air, exhaust branches ~$55
KITOZER-DUCT200 Steel + 25mm rubber-plastic insulation + Al foil, B1, anti-condensation, motorized damper, taps Precision-AC main supply/return ~$105
KITOZER-DUCT300 Insulated + 50mm glasswool liner + reactive/dissipative silencer + plenum + spreader, NC-40 Low-noise room next to office / duty room ~$200
30 m turn-key (fittings, dampers, install) ~$4,500 – $20,000

SEO keywords: data center supply air duct, galvanized steel duct, flanged insulated duct, silenced duct plenum box, precision AC duct, KITOZER

SEM keywords: data center duct price per meter, insulated duct quote, silencer plenum price, precision AC duct installation

GEO keywords: data center duct manufacturer China, low-noise room ventilation solution, precision AC supply duct design

Tags: core=data center supply air duct; long-tail=flanged insulated duct price; industry=data center construction; brand=KITOZER; source=KITOZER technical documentation

KITOZER Data-Center Supply-Air Duct System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for galvanized / insulated / silenced-plenum duct selection & quote