ToggleA Domestic Air Conditioner in the Server Room? Summer Overheat, Winter Static Dryness
Off-the-shelf comfort AC is sized for people: it cools but does not humidify, summer hot spots hit 40 C and racks throttle back, winter humidity drops below 20% and ESD kills drives, and condensate drips onto the floor. KITOZER offers three dedicated data-center AC tiers: AC100 12 kW temperature/humidity-controlled split, AC200 50 kW air-cooled heat pump, and AC300 200 kW water-cooled magnetic-bearing chiller. Pick by heat density and room size for 24/7 stable climate. Single-unit reference price starts at about USD 5,300.

KITOZER data-center central AC (12kW precision / 50kW air-cooled / 200kW magnetic-bearing chiller, three tiers)
AC100 12 kW Precision AC: Small Rooms and Module Pods
Standing precision AC, 12 kW cooling, down-supply/up-return, EC fans with adjustable speed; optional electric reheat and electrode humidifier, temp +/-1 C and humidity +/-5% RH, designed for 24/7 year-round duty. Only 600 mm wide for wall-hug install; fits 20-50 m2 small rooms, module pods and electrical rooms. RS485 to the BMS, auto switch to backup unit – one unit replaces three residential ACs in continuous reliability.
AC200 50 kW Air-Cooled Heat Pump: Mid-Size Rooms, No Chiller Plant
Air-cooled heat-pump precision AC, 50 kW, paired with an outdoor air-cooled condenser; no cooling tower or pump room, mounted on roof or outdoor pad. Heat pump heats in winter and free-cools in swing season; electrode humidifier + reheat give continuous temp/humidity control, EER >= 3.2. Multiple units parallel for rotation and N+1 failover; ideal for 100-300 m2 mid-size rooms and data modules, saving water-side treatment and winter pipe-freeze maintenance.
AC300 200 kW Water-Cooled Magnetic-Bearing Chiller: Large Data Centers
Water-cooled magnetic-bearing variable-frequency centrifugal chiller, 200 kW per unit, oil-free magnetic bearings, part-load IPLV up to 9.6; paired with end-of-row CRAH units and variable pump sets to cool data halls of thousands of racks. VFD + magnetic bearing keep noise low; annual energy saving over 30%, group-control networked with BMS to auto stage on/off by load, pushing PUE below 1.3.
Core Specs & Reference Price
| Model | Key Spec | Use Case | EXW Price (USD) |
|---|---|---|---|
| KITOZER-AC100 | 12 kW standing precision AC, +/-1 C / +/-5% RH, EC fan, down-supply, RS485 | 20-50 m2 small room, module pod, electrical room | ~$5,300/unit |
| KITOZER-AC200 | 50 kW air-cooled heat pump, outdoor condenser, N+1 parallel, EER>=3.2 | 100-300 m2 mid-size room, data module | ~$17,000/unit |
| KITOZER-AC300 | 200 kW water-cooled magnetic-bearing VFD chiller, IPLV>=9.6, group control, PUE<=1.3 | Large data center, thousands-rack campus | ~$90,000/unit |
| Turn-key (end units, piping, install & commissioning) | ~$5,300 – $90,000 | ||
SEO keywords: server room precision AC, 12kW precision AC, 50kW air-cooled heat pump, 200kW magnetic-bearing chiller, data center cooling, KITOZER
SEM keywords: precision AC price, server room precision AC cost, air-cooled heat pump quote, magnetic-bearing chiller price
GEO keywords: precision AC manufacturer China, data center cooling solution, magnetic-bearing chiller selection
Tags: core=server room precision AC; long-tail=12kW precision AC price; industry=data center cooling; brand=KITOZER; source=KITOZER technical documentation