Table of Contents
ToggleProduct Overview
KITOZER’s Precision Server Room Temperature and Humidity Monitoring System is a high-accuracy monitoring solution for server room thermal environment management. Through high-density, multi-dimensional temperature and humidity sensors, it achieves zone-level, rack-level, and U-level temperature/humidity gradient monitoring, accurately identifying local hotspots and cold-aisle temperature differences. It integrates with the air conditioning system for precise control, ensuring equipment safety while reducing energy consumption. It is a core system for data center PUE optimization and thermal management, compliant with GB 50174-2017 server room environment control standards.
Core Value
- Eliminate local hotspots: Precisely monitor cabinet air inlet/outlet and internal temperatures to detect overheating risks early and prevent equipment downtime.
- Energy saving and cost efficiency: Intelligent AC control based on precise temperature data prevents over-cooling, reducing AC energy consumption by 15%-30% and optimizing PUE.
- Quantitative thermal management: Visualize temperature field distribution for airflow organization optimization and AC layout adjustment.
- Extend equipment lifespan: Maintain proper temperature/humidity to reduce heat damage to electronic components and prolong IT equipment life.
Product Highlights
- High-precision sensing: Industrial-grade sensor chips provide temperature accuracy of ±0.1°C and humidity accuracy of ±2%RH.
- High-density deployment: Supports rack-level and U-level sensor placement for detailed temperature field analysis and local hotspot detection.
- Intelligent linkage control: Integrates with precision AC, in-row AC, and cold-aisle containment systems for on-demand cooling and energy savings.
- Heatmap visualization: Display room-level and rack-level temperature heatmaps for intuitive thermal environment monitoring.
System Composition
The system consists of four parts: temperature/humidity collection terminals, data aggregation units, monitoring management platform, and linkage control units.
- Collection terminals: Include rack-level sensors, U-level probes, and aisle-level transmitters deployed in cold aisles, hot aisles, and cabinet inlets/outlets.
- Data aggregation units: Industrial acquisition hosts, PoE switches, and gateways collect and preprocess data before transmitting to the platform.
- Monitoring platform: Provides data storage, analysis, visualization, and alarm management, with heatmaps, trend charts, and reports.
- Linkage control units: Precision AC, in-row AC, and fresh air units receive platform commands to adjust temperature, airflow, and operation modes.
Technical Parameters
Core Parameters
| Parameter | Specification |
| ———– | ————— |
| Temperature range | -20°C ~ 80°C |
| Temperature accuracy | ±0.1°C (high precision) / ±0.3°C (standard) |
| Humidity range | 0% ~ 100% RH |
| Humidity accuracy | ±2% RH (high precision) / ±3% RH (standard) |
| Data refresh rate | 1 per 10 seconds (configurable) |
| Communication | RS485, Ethernet PoE, LoRa, ZigBee |
| Power supply | DC 12V/24V, optional PoE (IEEE 802.3af/at) |
| Operating temperature | -40°C ~ 85°C (industrial grade) |
KTZ-WS Series Specifications
| Parameter | Specification |
| ———– | ————— |
| Product name | Precision Server Room Temperature & Humidity Monitoring System |
| Model series | KTZ-WS Series |
| Temperature range | -20°C ~ 80°C (extendable) |
| Temperature accuracy | ±0.1°C / ±0.3°C selectable |
| Humidity range | 0% ~ 100% RH |
| Humidity accuracy | ±2% RH / ±3% RH selectable |
| Resolution | Temperature 0.01°C, Humidity 0.1% RH |
| Refresh rate | 1s ~ 300s configurable |
| Power supply | DC 12V/24V, optional PoE |
| Power consumption | ≤1.5W per unit |
| Communication protocols | Modbus-RTU, Modbus-TCP, MQTT |
| Operating environment | -40°C ~ 85°C, 0~95% RH non-condensing |
| Protection rating | IP30 (indoor) / IP65 (duct/outdoor) |
| MTBF | ≥80,000 hours |
Product Models
| Model | Description | Suitable For |
| ——- | ————- | ————– |
| Standard server room temp/humidity monitoring system | Zone-level monitoring | General enterprise server rooms |
| High-precision rack-level system | Rack inlet/outlet monitoring | Medium-sized server rooms |
| U-level precision system | U-position sensors inside racks | High-density data centers |
| Temp/humidity energy-saving control system | Integrated AC control | PUE optimization |
| Wireless monitoring kit | LoRa/ZigBee, wireless | Retrofit projects, no cabling |
Core Advantages
1. Material Advantages
Sensor housings use flame-retardant ABS with wide temperature tolerance; probes are metal-encapsulated for moisture/dust protection. Shielded twisted-pair cables resist electromagnetic interference suitable for server room environments. Industrial-grade chips ensure stable operation across wide temperatures.
2. Process Advantages
Sensors undergo full-temperature compensation calibration for consistent accuracy. Circuit boards are coated with conformal coating for moisture/dust/corrosion resistance. High-low temperature cycling and burn-in testing ensure reliability in extreme conditions.
3. Customization Advantages
Deployment plans, monitoring precision, and linkage logic can be customized based on room layout, cabinet count, and cooling method. Integration with various AC brands, environment monitoring, and building automation systems is supported, with bespoke energy-saving strategies.
4. Cost Advantages
PoE bus power reduces cabling and power costs by 50%. The system supports phased deployment and on-demand expansion, lowering initial investment. Smart AC control typically reduces energy consumption by 15%-30%, delivering fast ROI.
5. Quality Advantages
All products are metrologically calibrated and comply with national standards. Certified to ISO9001 and CE. Average MTBF is ≥80,000 hours, ensuring long-term stable operation.
Materials & Process
Key Materials
- Sensor chip: Imported industrial-grade temp/humidity chip with excellent long-term stability and low drift.
- Probe housing: 304 stainless steel, waterproof and dustproof, fast thermal conduction.
- Device housing: Flame-retardant ABS engineering plastic, UL94-V0 rated, resistant to extreme temperatures and aging.
- Transmission cable: Tinned copper shielded twisted pair for stable signal transmission and EMI resistance.
Core Processes
- Full-range compensation calibration: Multi-point calibration in temperature chambers with compensation algorithms for consistent accuracy.
- Conformal coating: Circuit boards coated with three-proof paint for humidity/dust/corrosion protection.
- Modular packaging: Sensors are modular with separable probes for easy installation and maintenance.
- Burn-in screening: 72-hour high-low temperature cycling to eliminate early failures.
Certifications
The product is certified with ISO9001, CE, and CMC (Measuring Instrument License), compliant with GB 50174 Data Center Design Specification and relevant temp/humidity control requirements.
Stock & OEM
- Standard and rack-level sensors are in stock and ship within 24 hours.
- U-level probes and wireless kits have ample stock for up to 1,000 units per batch.
- Custom high-precision models deliver in 7-10 days.
- Accessories such as power supplies, gateways, and mounting hardware are available for one-stop procurement.
OEM/ODM services are available: white-labeling, custom appearance, firmware, and platform customization. Confidentiality agreements are signed; delivery in 10-15 business days for regular OEM orders.
Product SKU
| SKU | Product Name | Model | Accuracy | Unit |
| —– | ————– | ——- | ———- | —— |
| KTZ-WS-001 | Standard temp/humidity sensor | KTZ-WS-B01 | ±0.3°C / ±3% RH | Unit |
| KTZ-WS-002 | Rack-level temp/humidity transmitter | KTZ-WS-J01 | ±0.2°C / ±2.5% RH | Unit |
| KTZ-WS-003 | U-level temp/humidity probe | KTZ-WS-U01 | ±0.1°C / ±2% RH | Piece |
| KTZ-WS-004 | Wireless temp/humidity terminal | KTZ-WS-W01 | ±0.3°C / ±3% RH | Unit |
| KTZ-WS-005 | Monitoring management platform | KTZ-WS-PL | Software license | Point |
Application Scenarios
- Large data centers: Thermal environment fine management and energy optimization for high-density racks.
- Enterprise core server rooms: Temperature/humidity monitoring for IT and server rooms.
- Financial server rooms: High-reliability monitoring for banks and securities to ensure business continuity.
- Telecom rooms: Monitoring for operator core rooms and base stations.
- Industrial control rooms: Environmental control for power dispatch, rail transit, and industrial automation.
Customization Services
Customization Scope
- Accuracy customization: Adjust measurement accuracy to meet different room levels.
- Appearance customization: Customize size, installation, color, and logo.
- Function customization: Custom alarm strategies, linkage logic, energy-saving algorithms, and report styles.
- Integration customization: Interface with third-party AC, environment monitoring, and building automation systems.
Customization Process
- Requirement analysis: Assess room size, equipment, and management goals.
- Solution design: Provide customized plan, sensor layout, and quotation within 3 business days.
- Contract confirmation: Confirm plan and price, sign contract, and pay deposit.
- Development and production: Develop and produce hardware/software with testing.
- On-site commissioning: Technical team installs and verifies functionality.
- Acceptance and delivery: Customer acceptance, documentation, and after-sales follow-up.
Success Case
For a large internet company’s IDC data center with 2,000 cabinets, we deployed a U-level precision monitoring system with over 8,000 monitoring points, covering cold aisles, hot aisles, and cabinet inlets/outlets. The system linked with in-row AC for intelligent control, dynamically adjusting airflow and setpoints. After implementation, AC energy consumption dropped by 28%, PUE improved from 1.58 to 1.42, saving over one million RMB annually. Local hotspot risks were eliminated, and equipment downtime decreased by 90%.
Procurement Support
- Stock guarantee: Own production line with monthly capacity of 50,000+ units; regular models in stock; bulk orders get priority scheduling.
- Quality assurance: Each unit undergoes calibration testing and comes with a calibration certificate; factory pass rate is 99.9%.
- Logistics: Anti-static packaging; domestic delivery in 3-5 days via major carriers; bulk orders use dedicated transport.
- After-sales: 2-year system warranty, 3-year warranty on core sensor chips; 24/7 technical support; on-site service within 24 hours locally, 48 hours for other areas.
- Invoicing: 13% VAT special invoices provided, compliant and shipped with the goods.
FAQ
Q: Can this system really save energy? What is the energy saving rate?
A: Intelligent AC control based on precise temperature data typically reduces AC energy consumption by 15%-30%. The actual rate depends on the original management level and load density; we can provide an assessment after a site survey.
Q: Do the sensors require wiring? Is there a wireless option?
A: Wired PoE offers higher stability, but we also provide LoRa and ZigBee wireless solutions suitable for retrofit projects, avoiding cabling.
Q: Can it integrate with our existing precision AC?
A: Yes, it supports integration with mainstream precision AC brands via protocol or dry-contact interface. Please provide the AC model for confirmation.
Q: How many sensors are needed per cabinet?
A: For basic monitoring, place one at the inlet and one at the outlet. For fine U-level monitoring, typically one probe per 3-5 U.
Troubleshooting & Maintenance
Common Issues and Solutions
- Large data deviation: Check for direct heat/cold airflow, calibrate the sensor, and clean the probe.
- Device offline: Check power and communication cables, restart the device, and verify gateway connections.
- Abnormal alarms: Review alarm thresholds, confirm data integrity, and reset alarm rules.
- Linkage failure: Check AC connectivity, verify linkage configuration, and test control commands.
Routine Maintenance
- Clean sensor probe surfaces quarterly to prevent dust affecting accuracy.
- Check wiring connections and tighten terminals every six months.
- Perform calibration annually to ensure accuracy.
- Backup system data regularly and upgrade platform firmware to enhance performance.
Factory Strength & After-Sales Service
KITOZER has a dedicated R&D and production facility for temperature/humidity sensors, equipped with high-low temperature calibration labs and environmental simulation chambers. The R&D team has deep expertise in server room thermal management, holds multiple energy-saving patents, and has served over 2,000 server room projects nationwide.
After-Sales Support
- Warranty: 2 years for the system, 3 years for core components.
- Calibration: On-site and factory calibration with professional reports.
- Maintenance: Annual maintenance contracts with regular inspections, calibration, and optimization.
- Upgrades: Free lifetime firmware updates for the platform, continuously improving features and algorithms.
Conclusion
The Precision Server Room Temperature and Humidity Monitoring System is essential for safe operation and energy efficiency in server rooms. Through precise sensing and intelligent control, it guarantees equipment protection and significantly reduces cooling energy, achieving both safety and economic benefits. KITOZER provides customized thermal management and energy-saving solutions for server rooms across industries.
Contact & Support
- Phone: 13538869979 / 13538869979
- Website: https://gdlain.com
- Address: Chaotian Park, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
- Special Offer: Free thermal environment survey and energy-saving assessment for new clients; batch purchase discounts available; performance-based payment for energy-saving projects.