Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Data Center Dust Monitoring System – KITOZER

Product Overview

The KITOZER Data Center Dust Monitoring System is a professional monitoring solution designed for cleanroom control in data centers and server rooms. Using high-precision laser dust sensors, it continuously monitors PM2.5, PM10, and TSP concentrations in real time. Combined with data visualization and interlocking control, the system promptly detects dust exceedance risks and activates fresh air or dedusting equipment to prevent issues such as poor heat dissipation, short circuits, and static failures in IT equipment. This ensures stable operation and extends equipment lifespan, meeting the cleanroom requirements of GB 50174-2017 for data centers.

Product Positioning

The system is tailored for cleanroom management in various environments, including data centers, enterprise IT rooms, cleanrooms, communication base stations, and industrial control rooms. By precisely quantifying dust levels, it provides data support and intelligent interlocking actions to ensure safe equipment operation.

Core Value

  • Equipment Safety: Real-time dust monitoring with immediate alerts on exceedance, preventing short circuits, heat dissipation failures, and static damage.
  • Compliance: Quantifies cleanroom metrics, meeting ISO Class 8, GB 50174, and other standards for compliance inspection.
  • Reduced Operation Costs: Automatic interlocking with fresh air and dedusting systems reduces manual inspection and cleaning frequency.
  • Extended Equipment Life: Controlling dust concentrations within appropriate ranges minimizes erosion of electronic components, prolonging IT equipment lifespan.

Product Highlights

  • High-Precision Sensing: Uses laser forward-scattering sensors with high accuracy and fast response, detecting particles from 0.1μm to 100μm.
  • Multi-Parameter Monitoring: Monitors PM2.5, PM10, and TSP, with optional expansion for temperature, humidity, VOC, differential pressure, etc.
  • Intelligent Interlocking: Automatically activates fresh air systems, FFU units, and dedusting equipment when dust levels exceed thresholds, achieving closed-loop control.
  • Data Trend Analysis: Supports historical data storage, trend analysis, and report export for optimized cleanroom management.

System Composition

The system consists of four parts: dust acquisition terminals, data transmission units, monitoring management platform, and interlocking execution units.

  • Dust Acquisition Terminals: Include laser dust sensors, particulate transmitters, and particle counters deployed at supply air outlets, return air inlets, between racks, and floor areas to collect dust data.
  • Data Transmission Units: Use RS485, Ethernet, LoRa, or WiFi to ensure stable data upload.
  • Monitoring Management Platform: Core for data processing, storage, display, and alerts, accessible via web, client, and mobile apps.
  • Interlocking Execution Units: Fresh air systems, FFU filter units, dedusting equipment, and air conditioning systems that receive commands to start/stop or adjust air volume.

Core Technical Parameters

Parameter Specification
———– —————
Measurement Principle Laser forward scattering
Measured Parameters PM2.5, PM10, TSP (expandable to particle count)
Measurement Range 0-1000 μg/m³ (customizable)
Accuracy ±2% FS, repeatability ≤1% FS
Response Time ≤10 seconds
Data Refresh Rate 1 time/second
Power Supply DC 12V/24V, AC 220V optional
Operating Temperature -10°C to 60°C
Ingress Protection IP30 (indoor), IP65 (duct type)
Power Consumption ≤3W
Communication RS485, Ethernet, WiFi, LoRa (optional)
Operating Humidity 0-95% RH non-condensing
MTBF ≥50,000 hours

Core Advantages

Material Advantage

The sensor housing uses flame-retardant antistatic ABS, and the air passage uses antistatic engineering plastics to prevent static attraction of dust from affecting accuracy. Optical components feature high-transmittance quartz glass, resistant to wear and contamination for long-term stability.

Process Advantage

The optical cavity is precision-molded with a matte inner surface to avoid light interference. Each sensor is calibrated in a standard dust chamber before shipping. The entire unit undergoes dust aging tests for reliable continuous operation.

Customization Advantage

We support customized deployment plans, measurement ranges, and alarm thresholds based on room area and cleanroom class. Integration with existing dynamic environment systems, building automation, and fresh air systems is available with customized interlocking logic.

Cost Advantage

Utilizing domestically produced high-precision sensor cores, costs are reduced by more than 30% compared to imported alternatives. Modular design lowers maintenance costs, and automatic interlocking reduces manual cleaning and operation expenses, delivering excellent long-term ROI.

Quality Advantage

Sensors undergo third-party metrological calibration for reliable data. Products are ISO9001 and CE certified, compliant with cleanroom monitoring standards, and have an MTBF of ≥50,000 hours.

Product Variants

  • Wall-Mounted Dust Monitor: For indoor wall installation, monitoring overall dust concentration with easy installation.
  • Duct-Type Dust Transmitter: Installed in air conditioning or fresh air ducts, monitoring supply/return air dust concentration with threaded or flange mounting.
  • Rack-Level Dust Monitoring Terminal: Compact device for deployment inside server racks to monitor micro-environment dust.
  • Multi-Parameter Cleanroom Monitoring Kit: Integrates dust, temperature, humidity, differential pressure, and VOC monitoring, suitable for high-standard A-class cleanrooms.
  • Dust Monitoring Management Platform: Centralizes multi-point dust data, supports interlocking control and data analysis.

Materials & Process Analysis

Material Details

  • Sensor Housing: Flame-retardant ABS engineering plastic, UL94-V0 rated, antistatic treated to prevent dust attraction.
  • Optical Components: Imported high-transmittance quartz glass, transmittance ≥92%, wear-resistant and corrosion-resistant for stable laser path.
  • Air Path Components: Food-grade PE material, smooth inner walls to prevent dust accumulation and ensure smooth airflow.
  • Chassis: Cold-rolled steel with electrostatic powder coating, 19-inch rack-mount design, corrosion-resistant and anti-interference.

Core Processes

  • Standard Chamber Calibration: Each sensor is multi-point calibrated in a standard dust chamber to ensure full-range accuracy and metrological compliance.
  • Antistatic Treatment: Both housing and internal circuits are antistatic to avoid electrostatic interference from the data center environment.
  • Active Air Intake Design: Uses an active suction air path for stable airflow, fast response, and representative measurements.
  • Sealing Protection: Indoor units are IP30 dust-protected; duct-type units are IP65 protected for various installation scenarios.

Certifications

Products comply with ISO9001, CE, CMC metrological license, and China Environmental Protection Product Certification. They align with GB 50073 (Cleanroom Design Code) and GB 50174 (Data Center Design Code), and can achieve ISO Class 8 cleanroom standards for A-class rooms.

Stock & Availability

  • Wall-mounted and duct-type dust monitors in standard ranges are in stock and shipped within 24 hours.
  • Rack-level terminals and multi-parameter kits have ample stock for orders up to 500 units per batch.
  • Customized ranges and features require scheduling; delivery in 7-10 days.
  • Accessories such as mounting brackets, power supplies, and communication modules are in stock for one-stop procurement.

OEM/ODM Services

We offer full-series OEM/ODM services, including brand labeling, custom silkscreen, packaging, and firmware customization. Strict confidentiality agreements protect your product schemes, parameters, and branding. Services cover sensor modules to complete units and platforms. Batch OEM production takes 10-15 days with flexible scheduling.

Product SKU Attributes

SKU Code Product Name Model Mounting Type Unit
———- ————– ——- ————— ——
KTZ-FC-001 Wall-Mounted Dust Monitor KTZ-FC-B01 Wall-mounted Unit
KTZ-FC-002 Duct-Type Dust Transmitter KTZ-FC-G01 Duct install Unit
KTZ-FC-003 Rack-Level Dust Monitoring Terminal KTZ-FC-J01 Rack install Unit
KTZ-FC-004 Multi-Parameter Cleanroom Monitoring Kit KTZ-FC-D01 Wall/Rack Kit
KTZ-FC-005 Dust Monitoring Platform License KTZ-FC-PL Software license Point

Application Scenarios

  • Data Centers: Cleanliness monitoring for large data centers and disaster recovery centers, meeting A-class cleanroom standards.
  • Enterprise IT Rooms: Dust monitoring for server and network rooms to protect IT equipment.
  • Cleanrooms: Dust concentration control in pharmaceutical, electronics, and semiconductor cleanrooms.
  • Communication Base Stations: Dust monitoring for outdoor and edge base stations to prevent dust-induced failures.
  • Industrial Control Rooms: Environmental cleanliness monitoring in power, rail transit, and factory automation control rooms.

Customization Services

Customization Scope

  • Measurement Range: Custom range to suit high-dust or ultra-clean scenarios.
  • Parameters: Expand to include temperature, humidity, differential pressure, VOC, formaldehyde, etc.
  • Functions: Custom alarm rules, interlocking logic, data reports, and third-party system integration.
  • Appearance: Custom appearance, size, mounting method, and silkscreen logo.

Customization Process

  1. Requirements discussion: Clarify needs and application scenarios.
  2. Proposal & quote: Deliver customization plan and quote within 2 business days.
  3. Contract signing: Finalize plan, sign contract, and pay deposit.
  4. Prototype testing: Manufacture sample for customer validation.
  5. Mass production: Proceed with batch production under full quality control.
  6. Delivery & acceptance: Deliver finished products with technical support and after-sales service.

Customization Advantages

  • Core technology owned, both sensors and platform are customizable for high flexibility.
  • Professional calibration lab ensures measurement accuracy for custom products.
  • Low minimum order quantity: customization available from 5 units to meet non-standard needs.
  • Fast delivery: standard customization samples in 7 days, batch production in 15 days.

Success Case

Client: A semiconductor company’s cleanroom.

Deployed a multi-parameter dust monitoring system with 36 monitoring points covering the entire cleanroom, air ducts, and inside racks. Integrated PM2.5, PM10, temperature, humidity, and differential pressure monitoring. The system interlocks with fresh air and FFU units to automatically adjust airflow on dust exceedance. The cleanroom maintained ISO Class 7 stability, reducing dust-related equipment failures by 75% and helping the client achieve ISO 14644 certification.

Procurement Support

  • Supply Assurance: In-house sensor production and assembly line, regular models in stock, rapid production scheduling for bulk orders, ample inventory of core components.
  • Quality Assurance: Each unit is calibrated in a standard dust chamber and comes with a calibration certificate. Full-process quality control keeps defect rate below 0.2%.
  • Logistics: Professional shockproof packaging, partnered with SF Express and JD Logistics for next-day delivery in most domestic areas. Dedicated fragile goods shipping ensures safe transportation.
  • After-Sales: 18-month warranty on the whole unit, free calibration and repair during warranty. 7*24 technical support, periodic calibration services, and consumable replacement guidance.
  • Invoicing: 13% VAT special invoice available, accurate information, shipped with goods or separately, with invoice status inquiry.

Conversion Module

Action Buttons: Get Quote, Schedule Survey, Request Sample, Technical Consultation

Contact: Phone: 13538869979 / 13538869979; Website: https://gdlain.com

Address: Chaotian Industrial Park, No.5 Huashan Road, Shilou Town, Panyu District, Guangzhou

Promotional Offer: 10% discount for bulk orders of 10+ units, free layout design, and one year of calibration service for first-time customers.

FAQ

Q: How often should the dust monitor be calibrated?

A: It is recommended to calibrate once a year in normal conditions, and every six months in high-dust environments to ensure accuracy.

Q: Can it integrate with our existing dynamic environment system?

A: Yes, it supports standard Modbus-RTU and Modbus-TCP protocols and provides API interfaces for integration with mainstream dynamic environment and building automation systems.

Q: Is installation complicated? Do we need cabling?

A: Wall-mounted installation is simple: fix the bracket, connect power and signal wires. Wireless LoRa/WiFi versions are available to reduce cabling cost.

Q: What is the dust concentration standard for A-class data centers?

A: According to GB 50174-2017, in A-class data centers, the particle count per liter of air for particles ≥0.5μm should not exceed 18,000, corresponding to ISO Class 8.

Troubleshooting & Maintenance

Common Issues & Solutions

  • No data change: Check if air path is clogged, clean the inlet filter, and verify power and communication connections.
  • Large data deviation: Check for direct strong light or strong airflow interference, perform calibration, or return to factory if necessary.
  • Device offline: Check power supply and communication wiring, restart the device.
  • Alarm not triggering: Check alarm threshold settings, confirm data upload, and reset alarm rules.

Routine Maintenance

  • Clean the inlet filter monthly to keep the air path unobstructed.
  • Quarterly inspect mounting and clean the optical window surface.
  • Perform annual metrological calibration to ensure accuracy.
  • Avoid installing in locations with strong airflow, direct sunlight, or strong electromagnetic interference.

Factory Strength & After-Sales Service

Factory Strength

Equipped with an R&D and production center for environmental monitoring equipment, including a standard dust calibration chamber and environmental simulation lab. We have core sensor R&D and calibration capabilities. Annual production capacity exceeds 50,000 units, serving thousands of government and enterprise customers nationwide with rich experience in data center cleanroom monitoring.

After-Sales Service

  • Warranty: 18 months for the whole unit, 2 years for core sensors.
  • Calibration: On-site or factory calibration services with professional calibration reports.
  • Technical Support: 7*24 hotline and remote installation/debugging guidance.
  • Extended Warranty: Optional extended warranty plans for longer coverage.

Conclusion

The data center dust monitoring system plays a vital role in environmental control. By precisely quantifying dust levels and intelligently interlocking purification equipment, it creates a clean and safe environment for IT equipment, effectively reducing failure risks and extending equipment lifespan. We provide customized cleanroom monitoring solutions for various industries with professional technology and reliable products.

—

Related Keywords: Data Center Dynamic Environment Video Linkage System, Data Center Temperature and Humidity Monitoring System, Data Center Fire Alarm Linkage System, Data Center Access Control and Personnel Location System, Data Center Environment Monitoring System, Data Center Intelligent System

Scroll to Top