Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Precision Power Distribution Monitoring System for Data Centers | KITOZER

Product Overview

The Precision Power Distribution Monitoring System is a refined measurement and monitoring solution designed for data center rack PDU (distribution cabinets) and power distribution cabinets. It provides real-time monitoring of full-circuit parameters for both incoming and outgoing lines, including voltage, current, power, energy, harmonics, and breaker status. This helps operators understand the operational status of the power distribution system, identify potential electrical hazards, and achieve refined energy management. It is a core system for data center power safety and energy efficiency.

Product Positioning

This system serves as an intelligent monitoring platform for critical power infrastructure in data centers, telecommunication rooms, and other key facilities. By collecting comprehensive real-time data from input and output circuits of rack PDUs and main distribution cabinets, it provides visual operational status, promptly detects anomalies such as overload, undervoltage, or excessive harmonics, and supports refined energy consumption management and PUE optimization.

Core Value

  • Safety Assurance: Real-time monitoring of distribution parameters with early warning of overload, undervoltage, harmonic distortion, preventing power failures.
  • Precision Metering: Branch-level energy measurement accurately tracks power usage of racks and equipment, providing data support for PUE calculation and energy-saving optimization.
  • Operational Efficiency: Remote visibility of distribution status eliminates manual meter reading, speeds up fault localization, and improves maintenance efficiency.
  • Compliance and Audit: Comprehensive energy data and event logs meet data center audit and security compliance requirements.
  • Capacity Management: Real-time monitoring of circuit load rates assists in distribution capacity planning and avoids overload risks.

Product Highlights

  • Single module supports up to 48 outgoing circuits, offering high integration to save installation space and cost.
  • High accuracy: voltage/current class 0.5, active energy class 1.
  • Harmonic analysis from 2nd to 63rd order, including THD calculation, to fully assess power quality and prevent interference with IT equipment.
  • Modular design with pluggable connections for easy installation, maintenance, and flexible expansion.
  • Supports dual incoming line monitoring, neutral-to-earth voltage, and residual current monitoring for comprehensive protection.
  • Seamlessly integrates with environment (DCIM) monitoring systems, unifying management with UPS, batteries, and other power equipment.

Product Classification and Composition

Product Classification

  • By Power Type: AC precision distribution monitoring system, DC precision distribution monitoring system
  • By Installation Location: Rack PDU monitoring system, main distribution cabinet monitoring system, cabinet-level power distribution monitoring
  • By Function Level: Basic current monitoring, standard full electrical parameter monitoring, high-end power quality analysis system

System Composition

  • Main Monitoring Unit: Full electrical parameter monitoring of incoming lines, data processing, and communication upload.
  • Branch Acquisition Module: Current and energy acquisition for outgoing circuits, expandable via daisy-chain connection.
  • Current Transformers / Hall Sensors: Current signal acquisition for different ratings.
  • Display and Operation Unit: Local touchscreen display, parameter setting, and status viewing.
  • Digital Input Module: Monitoring of breaker status and surge protection state.

Technical Specifications

  • Voltage measurement range: AC 0~500V, accuracy ±0.5%
  • Current measurement range: 5A/100A/200A/630A etc., accuracy ±0.5%
  • Active energy accuracy: Class 1
  • Harmonic analysis: 2nd to 63rd order, THD calculation
  • Outgoing circuits per module: up to 48 single-phase or 24 three-phase
  • Communication interface: RS485, RJ45 Ethernet, supports Modbus protocol
  • Power supply: AC/DC 85~265V wide range
  • Operating environment: temperature -10°C to 60°C, humidity 0% to 95% RH

Core Advantages

Material Advantage

  • Module housing: flame-retardant PC/ABS alloy, high heat resistance and insulation.
  • Current transformers: silicon steel core and enameled copper wire provide high accuracy and low loss.
  • Metering chip: dedicated energy metering IC with high precision and low temperature drift.
  • Terminals: copper flame-retardant terminals for excellent conductivity and high current capacity.

Craftsmanship Advantage

  • Main board: SMT patch process ensures reliable soldering.
  • Transformers: vacuum impregnation improves insulation.
  • Full unit: high/low temperature aging tests ensure stability.
  • Factory calibration: using high-precision standard sources to guarantee measurement accuracy.

Customization Advantage

  • Supports customization of circuit count, current rating, functional modules, and display interface.
  • Allows integration with third-party systems.
  • Custom installation solutions based on cabinet dimensions and structure.

Cost Advantage

  • High integration replaces multiple traditional meters, reducing hardware costs.
  • Pluggable wiring simplifies installation and reduces labor costs.
  • Accurate energy data supports energy-saving initiatives, lowering long-term electricity expenses.

Quality Advantage

  • Production strictly follows power instrumentation standards.
  • Every unit is calibrated and tested.
  • Core components from top-tier brands ensure long-term stability.
  • Certified according to power industry standards.

Product Family Details

  • AC Precision Distribution Monitoring Unit: Suitable for AC rack PDUs and distribution cabinets, monitors all electrical parameters for input and output lines.
  • DC Precision Distribution Monitoring Unit: Suitable for DC rack PDUs and HVDC systems, compatible with -48V/240V/336V systems.
  • Multi-Circuit Current Acquisition Module: Cost-effective option for branch current monitoring only.
  • Power Distribution Energy Management Platform: Unified management of multiple distribution cabinets, energy analysis, and report generation for large data centers.

Materials & Process Analysis

Material Details

  • Module Housing: Flame-retardant V0 PC/ABS alloy, resistant to 120°C, excellent insulation and mechanical strength.
  • Current Transformers: Oriented silicon steel core and high-strength enameled copper wire for precise ratio and phase angle.
  • Metering Chip: Dedicated high-precision three-phase energy metering IC with 24-bit ADC and harmonic calculation function.
  • Terminals: Copper flame-retardant terminals, secure wiring, high current capacity, anti-loosening.

Core Process

  • Calibration Process: Point-by-point calibration with high-accuracy standard source across full voltage, current, and energy range.
  • Transformer Winding: Precision winding ensures exact turns and minimal error, delivering high consistency.
  • Wave Soldering: Through-hole components wave soldered for reliable, robust solder joints.
  • Aging Test: 72-hour energized aging plus high/low temperature cycling to eliminate early failures and ensure long-term reliability.

Safety Certifications

  • CPA Measuring Instrument License
  • CE certification
  • RoHS compliance
  • Complies with GB/T 17215 electricity meter standards
  • Meets YD/T 2555 technical requirements for telecom distribution cabinets

Stock Availability

Standard monitoring units, common current transformers, and branch acquisition modules are in stock. Regular rack PDU monitoring kits are available. Orders ship within 24-48 hours; custom specifications delivered in 7-10 days.

OEM/ODM Services

We offer OEM/ODM services for precision power distribution monitoring systems, including module branding, custom display interfaces, function customization, custom case silk-screening, and packaging. We strictly protect customer technical solutions and information to safeguard brand rights.

Product Attributes (SKU)

SKU Code Product Name Model Application Scenario Unit
———- ————— ——- ———————- ——
PDJK-001 AC Precision Power Distribution Monitoring Master Unit KITOZER-PD-AC AC rack PDU incoming line monitoring unit
PDJK-002 Branch Acquisition Module (24 circuits) KITOZER-PD-Z24 Outgoing circuit monitoring unit
PDJK-003 Split-core Current Transformer 100A KITOZER-CT-100 Branch current monitoring pcs
PDJK-004 DC Precision Power Distribution Monitoring System KITOZER-PD-DC DC rack PDU monitoring set

Technical Specification Table

Parameter Category Parameter Technical Index
——————- ———– —————–
Measurement Accuracy Voltage ±0.5%FS
Current ±0.5%FS
Active Energy Class 1
Measurement Parameters Basic Electrical Parameters Voltage, current, power, power factor, frequency, energy
Power Quality 2-63 harmonics, THD, unbalance, neutral-earth voltage
Digital Inputs Breaker status, surge protection status
Circuit Count Incoming Lines Up to 2 three-phase circuits
Outgoing Lines Up to 48 single-phase / 24 three-phase per module
Communication Interface RS485 / RJ45 Ethernet
Protocol Modbus-RTU / Modbus-TCP
Electrical Power Supply AC/DC 85~265V wide range
Power Consumption ≤5W per module
Environment Operating Temperature -10°C to 60°C
Operating Humidity 0% to 95% RH
Installation Mounting DIN rail / screw fixing
Protection Rating IP20

Application Scenarios

  • Data Centers: Rack PDU precision monitoring, main distribution cabinet power quality monitoring
  • Machine Rooms: UPS output distribution, end-of-row cabinet power monitoring
  • Telecommunications: Telecom room power distribution, base station power monitoring
  • Industrial: Factory power distribution rooms, production line power monitoring
  • Commercial Buildings: Smart distribution, sub-metering for energy consumption

Customization Service Details

Customization Scope

  • Hardware: Custom number of circuits, current ratings, special voltage levels, mounting methods
  • Software: Custom function parameters, display interface, report templates, third-party system integration
  • Solution: Custom monitoring solutions based on specific distribution system architecture and management needs

Customization Process

Requirement communication → Parameter confirmation → Solution quotation → Contract signing → Custom production → Calibration and testing → Delivery and acceptance

Customization Advantages

  • Professional R&D team with deep knowledge of power distribution systems and industry standards
  • Modular product architecture for flexible customization and short lead times
  • High-precision calibration equipment ensures measurement accuracy of customized products
  • On-site adaptation debugging available to ensure perfect fit with distribution cabinets

Success Cases

Partner Customers

  • A large IDC data center
  • A telecom operator’s core computer room
  • A bank data center
  • A government cloud base

Case Highlights

  • IDC Data Center: Deployed 120 precision power distribution monitoring systems, achieving branch-level energy metering for all rack PDUs, precise single-rack PUE statistics, identified high-energy racks, and reduced overall PUE by 0.12 through optimization, saving over 1 million kWh annually.
  • Bank Data Center: Full parameter monitoring and harmonic analysis detected UPS harmonic distortion issues that were subsequently corrected, preventing interference with IT equipment and ensuring stable core business operations.
  • Government Cloud Base: Integration with environment monitoring platform enabled unified power system management, cutting fault localization time from 2 hours to 10 minutes, significantly improving maintenance efficiency.

Procurement Service Guarantee

Supply Guarantee

Standard products kept in stock, sufficient capacity for batch orders. Custom products delivered within agreed timeframes to ensure project schedules.

Quality Guarantee

Factory calibration ensures measurement accuracy. 1-year free warranty, lifetime maintenance. Complies with power industry standards for reliable metering.

Logistics Guarantee

Professional packaging resistant to shock and static. Door-to-door express delivery with full tracking. On-site installation, debugging, and calibration services available.

After-Sales Guarantee

7×24 technical support with remote assistance. Free calibration for metering accuracy issues. Free technical training and system upgrades.

Invoice Guarantee

13% VAT special invoices provided, compliant and customizable.

Conversion Module

Call-to-Action Buttons

Request a quote, consult on suitable solutions, schedule on-site survey

Contact Information

  • Hotline: 13538869979 / 13538869979
  • Website: https://gdlain.com
  • Brand: KITOZER

Company Address

Zhongrun Industrial Park, Chaotian Area, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

Promotional Offers

Free design of power distribution monitoring solution; 10% discount for first order from new customers; tiered discounts for bulk purchases; bundle discounts when ordering with environment monitoring systems.

FAQ (Frequently Asked Questions)

Q: Can it be installed directly into an existing distribution cabinet?

A: Yes. The module uses DIN rail mounting and is compact, so it can be added directly to existing distribution cabinets or rack PDUs without replacing the cabinet.

Q: How to choose a current transformer? Does installation require power shutdown?

A: Select the rating based on the circuit’s nominal current. Split-core transformers are available and can be installed without power interruption, ensuring uninterrupted supply.

Q: Does it support harmonic detection? How many harmonic orders?

A: High-end models support 2nd to 63rd harmonic detection, including total harmonic distortion (THD) calculation, meeting power quality analysis requirements.

Q: Can it track power usage of each individual rack?

A: Yes. Each outgoing circuit corresponds to one rack, allowing precise rack-level energy measurement and report generation.

Q: Can the system integrate with our existing energy management platform?

A: It supports standard Modbus protocol, enabling integration with most DCIM and energy management platforms. Custom integration is available for special platforms.

Troubleshooting and Maintenance

Common Faults and Solutions

  • No data display: Check CT wiring, circuit power, and CT ratio settings.
  • Large data deviation: Check CT accuracy class, wiring tightness, calibration parameters; recalibrate if needed.
  • Communication failure: Check communication line polarity, address, baud rate, and module power supply.
  • Incorrect switch status: Verify auxiliary contact wiring and contact continuity.

Routine Maintenance

  • Regularly inspect terminals for secure connection, overheating, or oxidation.
  • Keep modules clean and dry; maintain proper ventilation and humidity in the cabinet.
  • Perform annual calibration comparison to ensure accuracy.
  • Regularly back up energy data and configuration parameters.
  • Avoid operating in strong electromagnetic fields or high temperature/humidity; provide dust and moisture protection.

Factory Capabilities and After-Sales Service

Factory Strength

Dedicated power monitoring product line with high-precision metering calibration laboratory. Fully automated SMT production line with monthly capacity of 5,000+ modules. R&D team has over 10 years of experience in power instrumentation development.

After-Sales Service

  • Warranty: 1-year free hardware warranty, lifetime free software upgrades.
  • Calibration: Free annual remote calibration guidance to ensure accuracy.
  • Technical Support: 7×24 hotline with rapid response.
  • On-site Service: Installation, commissioning, and calibration available.
  • Lifetime Maintenance: Long-term supply of parts and technical support.

Conclusion

The power distribution system is the lifeline of a data center’s power infrastructure; its safe and stable operation directly affects all IT equipment. Our Precision Power Distribution Monitoring System provides accurate metering, comprehensive monitoring, and reliable quality to help customers fully understand the operational status of their power distribution system, prevent safety risks, achieve refined energy management, and safeguard the power supply of their facilities.