Table of Contents
ToggleProduct Overview
A shielded container is a high-performance electromagnetic shielding space based on a standard container structure, modified with a steel-plate welded shielding body and equipped with shielding doors, windows, waveguide ventilators, filters and other components. It effectively suppresses the transmission of electromagnetic waves in and out, meeting requirements for electromagnetic shielding, information security anti-leakage, and anti-interference for electronic equipment. It can be used as a mobile shielded computer room, secure communication shelter, EMC test chamber, precision electronic equipment protection shelter, or data security shelter, serving as the core carrier of mobile electromagnetic protection solutions.
Product Introduction
The shielded container transforms a standard ISO container into a robust Faraday cage using continuous welded steel plates. All necessary openings (doors, vents, cable penetrations) are treated with waveguide and filter technologies to maintain shielding integrity. The result is a deployable, relocatable space that provides reliable electromagnetic isolation for sensitive operations.
Product Positioning
Targeting classified units, communication operators, research institutes, military forces, data centers, and precision electronics enterprises, the shielded container offers a rapidly deployable and flexibly relocatable electromagnetic shielding space. It replaces traditional fixed shielded rooms for temporary deployment, field operations, and mobile command scenarios.
Core Value
- High Shielding Effectiveness: 60dB-100dB, meeting Class B/C/D shielding standards.
- Rapid Deployment: Factory-prefabricated integrated delivery; on-site lifting and power connection only, no civil construction.
- Mobility & Flexibility: Can be lifted and transported as a whole, compatible with road, rail, and sea transport.
- High Integration: Can integrate racks, air conditioning, fire suppression, monitoring, UPS, and complete machine room systems – ready to use after unpacking.
Product Highlights
- All-welded steel plate shielding structure, stable and reliable, no performance degradation over time.
- High-performance beryllium copper reed shielding door, opening/closing life ≥100,000 cycles, consistent shielding.
- Waveguide ventilation, power filtering, signal filtering, fiber-optic bulkhead – full-chain shielding without leaks.
- Multiple shielding options: electromagnetic, magnetic, RF.
- 20ft/40ft standard containers and multi-container splicing solutions for flexible space expansion.
Product Classification & Composition
Classification
- By Shielding Level: C-grade (60dB), B-grade (80dB), A-grade (100dB).
- By Function: Shielded machine room container, secure communication container, EMC test container, data shielding shelter.
- By Shielding Type: Electric field, magnetic field, electromagnetic field, pulse shielding.
- By Size: 20ft shielded container, 40ft shielded container, dual-container spliced shielded room, custom non-standard sizes.
System Composition
- Shielded Box Body: Shielding steel shell, base, top, and wall panels.
- Shielding Entry/Exit: Manual/electric shielded doors, emergency escape shielded doors, shielded observation windows.
- Ventilation Shielding System: Waveguide ventilators, shielded fans, ventilation ducts.
- Power Filtering System: Power filters, distribution system, grounding system.
- Signal Interface System: Signal filters, optical fiber waveguides, coaxial connector panels.
- Environmental Control System: Precision air conditioning, fresh air system, dehumidifier.
- Supporting Machine Room Systems: Server racks, UPS, fire suppression, environmental monitoring.
System Principle
Based on the Faraday cage principle, the shielded container uses a continuous conductive metal shell to enclose internal space. Electromagnetic waves are attenuated via:
- Reflection Loss: Incident waves are reflected back from the high-conductivity metal surface.
- Absorption Loss: Penetrating waves are absorbed as heat within the metal, rapidly decaying.
- Multiple Reflection Loss: Residual energy is further reduced by reflections between layers.
- Aperture Leakage Suppression: All necessary openings (vents, cable penetrations) are designed as waveguides – below cutoff frequency, waves cannot pass.
- Seam Leakage Suppression: All seams are continuously welded or sealed with conductive gaskets to ensure electrical continuity.
Technical Parameters
| Parameter | Value |
| ———– | ——- |
| Shielding Effectiveness | 60dB / 80dB / 100dB (10kHz-40GHz) |
| Shielding Structure | Cold-rolled steel plate, full welded |
| Steel Plate Thickness | 2mm / 3mm / 5mm |
| Shielded Door Type | Beryllium copper reed, knife-edge insertion |
| Protection Rating | IP54 (external) / IP30 (internal) |
| Operating Temperature | -10°C ~ +40°C (indoor type) / -40°C ~ +55°C (outdoor type) |
| Rated Voltage | AC220V/380V 50Hz |
| Grounding Resistance | ≤1Ω |
| Relative Humidity | ≤80% non-condensing |
| Design Life | ≥20 years |
Product Configuration List
| No. | Component | Specification/Model | Qty | Remarks |
| —– | ———– | ——————— | —– | ——— |
| 1 | Shielded container shell | 20GP/40GP custom | 1 set | Full-welded steel structure |
| 2 | Main shielded door | 900×2100mm manual | 1 unit | Beryllium copper reed seal |
| 3 | Emergency shielded door | 700×1800mm | 1 unit | Push-bar lock, escape direction |
| 4 | Waveguide ventilator | 300×300mm | 4-8 pcs | Cutoff waveguide type |
| 5 | Power filter | Single-phase / three-phase | 1-3 units | High performance |
| 6 | Signal filter panel | Custom interfaces | 1 panel | Ethernet/serial/fiber |
| 7 | Precision air conditioner | 3P/5P constant temp/humidity | 1-2 units | Shielded wall penetration |
| 8 | Server rack | 42U standard | 2-8 units | Based on space |
| 9 | Grounding copper busbar | 30×3mm copper | 1 set | Ring grounding |
| 10 | Fire suppression system | Heptafluoropropane gas | 1 set | Smoke/heat detector linked |
Core Advantages
Material Advantage
Shielding body uses Wuhan Steel certified cold-rolled steel plate with stable conductivity and uniform shielding. Door reeds use imported beryllium copper – elastic, wear-resistant, long-term performance. Conductive gaskets are high-conductivity foam or metal mesh with excellent compression recovery. All metal parts are anti-rust and anti-corrosion treated to ensure long-term electrical continuity.
Craftsmanship Advantage
Continuous CO2 gas-shielded welding produces dense, void-free seams ensuring electrical continuity. Interior shielding walls are phosphated and coated with conductive primer for enhanced conductivity and corrosion resistance. Shielded doors are precision-machined with CNC, achieving ±0.1mm fit accuracy between knife-edge and reeds. Each unit undergoes shielding effectiveness testing before shipment, with third-party test reports.
Customization Advantage
Full customization of shielding level, size, internal layout, and supporting systems. Internal rack arrangement, operator stations, and equipment mounting positions are designed per needs. Different shielding levels can balance performance and cost. Multi-container splicing supports large-space requirements. Professional electromagnetic shielding engineers provide design and effectiveness evaluation.
Cost Advantage
Compared to traditional civil-construction shielded rooms, containerized shielded rooms reduce comprehensive cost by ~40%; construction period shortened by over 70%, from order to delivery in only 20-30 days. Reusable and relocatable – no rebuilding needed for new sites. No civil construction approval required, saving time and cost.
Quality Advantage
Strictly designed and produced per GJB5792, BMB3 and other national/military shielding standards. Shielding effectiveness is certified by third-party authorities. Core shielding components are from industry-renowned brands. A complete quality management system includes multiple inspections from raw materials to finished products, ensuring every unit conforms.
Product Category Details
- Shielded Machine Room Container: Equipped with standard racks, precision AC, UPS, fire suppression, serving as mobile data room for temporary data centers, field data nodes.
- Secure Communication Container: High-level shielding, internally equipped with secure communication devices and classified computers to prevent electromagnetic leakage, for classified unit field operations.
- EMC Test Container: Built-in test antennas, turntable, filtering system, mobile EMC lab for field device testing.
- Precision Equipment Protection Shelter: Provides clean electromagnetic environment for high-precision electronic instruments, medical equipment, preventing interference.
- Pulse Protection Container: With strong electromagnetic pulse protection capability, safeguarding critical electronics from EMP attacks, for defense and emergency command scenarios.
Material & Craftsmanship Analysis
Material Details
- Shielding Shell: 2-5mm high-quality cold-rolled steel plate, Q235, high conductivity, stable shielding.
- Shielded Door Body: Steel plate welded frame + aluminum panel, lightweight yet reinforced.
- Beryllium Copper Reed: Beryllium bronze, hardness HRC38-42, conductivity ≥22% IACS, excellent elasticity.
- Waveguide Vent: Hexagonal honeycomb waveguide core, tin-plated steel, high cutoff frequency, large airflow.
- Conductive Gasket: Tin-plated copper mesh over foam, surface resistance ≤0.05Ω/sq, compression 30%-50%.
- Interior Decoration: 0.8mm color steel or galvanized plate, anti-static coating, beautiful and easy to clean.
Core Craftsmanship
- Shell Welding: Continuous full-penetration weld, weld height ≥ plate thickness, ground smooth, ensuring no electrical discontinuity.
- Surface Treatment: Interior phosphating + conductive primer; exterior sandblasting + epoxy zinc-rich + polyurethane topcoat for anti-corrosion.
- Shielded Door Machining: CNC bending, welding, precision finishing for planarity and fit.
- Reed Installation: Uniformly fixed with stainless screws, spacing ≤50mm, ensuring each contact.
- Effectiveness Testing: Tested per standard points over full band 10kHz-40GHz; non-conforming points corrected.
Safety Certifications
- National Secrecy Bureau classified information system product test certificate
- CNAS shielding effectiveness test report
- ISO9001 quality management system certification
- Military electromagnetic shielding standard compliance test
- Third-party lightning protection and grounding test report
Stock Availability
20ft C-grade shielded containers are commonly in stock with basic shielding configuration, can be quickly equipped with racks, AC, UPS, etc., delivered in 7-10 days. B-grade and above, 40ft sizes are custom products; lead time consult sales. All in-stock units pass factory shielding testing with test report included.
OEM / ODM Services
We offer shielded container OEM/ODM services, including client drawing fabrication, solution customization, and brand labeling. The company has a complete confidentiality management system, can sign NDA, and strictly protect customer project information, technical proposals, and business relationships. OEM products can be provided with neutral packaging and documentation. Multiple production lines ensure sufficient capacity for small and large orders.
Product Attributes (SKU)
| Attribute | Value |
| ———– | ——- |
| Product Name | Shielded Container |
| Model | LA-PB-20C / LA-PB-20B / LA-PB-40B |
| Shielding Level | C (60dB) / B (80dB) / A (100dB) |
| Container Size | 6058×2438×2896mm / 12192×2438×2896mm |
| Shell Material | Cold-rolled steel plate welded |
| Plate Thickness | 2mm / 3mm / 5mm |
| Operating Voltage | AC220V/380V 50Hz |
| Customization Lead Time | 20-35 days |
| Delivery | Factory pickup / logistics |
| Warranty | 1 year whole unit, 3 years shielding performance |
Specification & Parameter Table
| Model | External Dimensions (L×W×H) | Internal Clear Dimensions | Shielding Effectiveness | Plate Thickness | Racks Capacity | Reference Weight |
| ———— | ————————— | ————————— | ————————- | —————– | —————– | ——————- |
| LA-PB-20C | 6058×2438×2896mm | 5800×2200×2300mm | ≥60dB | 2mm | 4×42U | 5.5t |
| LA-PB-20B | 6058×2438×2896mm | 5750×2150×2250mm | ≥80dB | 3mm | 4×42U | 7t |
| LA-PB-40B | 12192×2438×2896mm | 11900×2150×2250mm | ≥80dB | 3mm | 10×42U | 13t |
| LA-PB-20A | 6058×2438×2896mm | 5700×2100×2200mm | ≥100dB | 5mm | 3×42U | 9t |
| LA-PB-40A | 12192×2438×2896mm | 11850×2100×2200mm | ≥100dB | 5mm | 9×42U | 17t |
Application Scenarios
- Party, government, military classified units: Mobile classified machine room, field classified office shelter.
- Telecom operators: Emergency communication shielded shelter, base station core equipment protection.
- Research institutes: Mobile EMC lab, field test shielded room.
- Data center industry: Edge data nodes, temporary disaster recovery machine room.
- Precision electronics manufacturing: Product testing shielded room, equipment protection shelter.
- National defense and military: Mobile command shielded shelter, electromagnetic protection equipment cabin.
- Public security and justice: Mobile interrogation shielded room, evidence-gathering data shelter.
- Broadcasting and TV: Signal transmission shielded machine room, live broadcast security shelter.
Customization Services
Customization Scope
- Shielding level customization: 60dB-120dB, different frequency bands.
- Size and structure customization: non-standard, multi-container splicing, double-layer, expandable.
- Interior decoration: anti-static floor, color steel wall, ceiling, insulation.
- Machine room systems: number of racks, UPS capacity, air conditioning cooling, fire suppression.
- Interface panel customization: power, network, fiber, RF, audio/video etc. filtered interfaces.
- Appearance customization: color coating, LOGO, warning signs, external accessories.
Customization Process
- Requirement Research: Understand usage scenario, shielding requirements, equipment configuration, site conditions.
- Solution Design: Produce shielding plan, layout drawing, system configuration, quotation.
- Technical Review: Confirm details and technical specs, sign technical agreement.
- Contract Signing: Confirm commercial terms, pay deposit, formal production scheduling.
- Production: Manufacture per technical agreement; invite customer for key-stage inspection.
- Factory Testing: Shielding effectiveness test after completion, issue test report.
- Delivery & Acceptance: Logistics, on-site installation and commissioning, customer acceptance.
Customization Advantages
- Senior electromagnetic shielding engineering team with military-grade project experience.
- Own complete production chain from sheet metal to shielding components, ensuring delivery and quality.
- Modular design concept for flexible combination of shielding levels and function modules.
- Third-party authoritative testing certification service available to ensure project acceptance.
Success Cases
Partner Customers
- A military command center, provincial secrecy bureau, provincial telecom operator, research institute, public security system.
Case Highlights
- Military Mobile Command Shielded Shelter: Customized multiple B-grade shielded command containers integrating command dispatch and video conferencing systems, meeting field mobile command information secrecy requirements, passed military secrecy testing.
- Telecom Emergency Communication Project: Customized 12 shielded communication shelters for a provincial operator, deployed as emergency communication core nodes in various cities, ensuring secure communications during major events and disasters.
- Research Institute Mobile EMC Lab: Customized A-grade shielded test container with built-in test systems and auxiliary equipment, enabling field EMC tests with shielding effectiveness above 100dB.
Procurement Service Guarantee
Supply Guarantee
Own large-scale shielded product production base, standard products in stock, customized products prioritized, full in-house production without outsourcing, ensuring stable supply.
Quality Guarantee
Strict production per national and industry shielding standards; three-level QC: incoming material inspection, in-process inspection, final inspection. Each unit includes shielding effectiveness test report.
Logistics Guarantee
Professional large-item logistics cooperation, nationwide door-to-door delivery, protective packing and fixing during transport, full transport insurance.
After-Sales Guarantee
Whole unit warranty 1 year, shielding performance warranty 3 years; lifelong maintenance service, periodic re-test of shielding effectiveness; 7×24 technical support, 48-hour on-site response.
Invoice Guarantee
Issues 13% VAT special invoice; invoice with shipment or separately mailed; smooth financial liaison.
Conversion Module
Company Information
Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER)
Contact
Mr. Zhou: +86-13538869979 (WeChat same)
Mr. Zhou: +86-13538869979 (WeChat same)
Address
Chaotian Park, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
FAQ
Q: What shielding effectiveness can a shielded container achieve?
A: Standard C-grade ≥60dB, B-grade ≥80dB, A-grade ≥100dB, frequency range 10kHz-40GHz; higher levels can be customized.
Q: Can a shielded container be transported? Will vibration affect shielding?
A: Yes, normal road and sea transportation is possible. The shielding structure is fully welded and rigid; transport vibration is considered in design. Normal lifting and transport will not affect shielding performance. Re-testing can be done after delivery.
Q: Does the shielded container need grounding? What are requirements?
A: Yes, reliable grounding with resistance ≤1Ω is required. Proper grounding is essential for shielding performance. We provide grounding system design and installation guidance.
Q: Will repeated door opening/closing degrade shielding?
A: The beryllium copper reed seal has a normal life ≥100,000 cycles; regular cleaning and maintenance maintain performance. Reeds are replaceable parts.
Q: Can windows be added without affecting shielding?
A: Shielded observation windows use metal mesh glass or waveguide structure, not affecting shielding performance. However, size is limited; consult technical staff.
Product Troubleshooting
| Symptom | Possible Cause | Solution |
| ——— | —————- | ———- |
| Shielding effectiveness drops | Door reeds dirty/deformed / filter failure / cable penetration leak | Clean reed contacts, replace damaged reeds, check filters and penetration seals |
| Door opens/closes poorly | Hinge lacks oil / door frame deformed / debris in threshold | Clean threshold, lubricate hinges, adjust door position |
| Insufficient ventilation | Waveguide vent clogged / fan failure | Clean waveguide vents, check fan power and motor |
| Air conditioner not cooling | AC fault / filter clogged | Clean AC filter, contact after-sales for repair |
| Filter trips | Downstream short circuit / filter damaged | Disconnect load and inspect stepwise, replace damaged filter |
Maintenance & Care
- Daily: Keep door reeds clean; wipe with anhydrous alcohol periodically; check door closure.
- Monthly: Clean waveguide vent dust; check grounding connection; test lighting and sockets.
- Quarterly: Check all shielding interface connections; tighten electrical wiring; test fire alarm function.
- Annually: Comprehensive shielding effectiveness test; inspect and replace aged seals; electrical safety check.
- Long-term idle: Periodically power on for dehumidification; inspect internal corrosion; implement dust and moisture prevention.
Factory Strength & After-Sales Service
We have a dedicated shielded product production workshop and shielding effectiveness testing laboratory, equipped with CNC machining equipment, shielding component production lines, and professional testing instruments. Our technical team consists of senior electromagnetic shielding engineers with years of military and classified project experience.
For after-sales, we provide installation guidance, operation training, periodic inspection, fault repair, and effectiveness re-testing throughout the lifecycle. Within warranty, free repair/replacement for non-human damage; after warranty, cost-based maintenance service with lifetime technical support. Annual maintenance agreements can be signed for more comprehensive protection.
Conclusion
The shielded container perfectly combines traditional fixed shielded rooms with container mobility, providing a new mobile solution for electromagnetic protection and information confidentiality. Guangzhou Lain, leveraging professional shielding expertise and rich project experience, offers one-stop shielded container solutions from design, manufacturing to testing and acceptance, helping customers achieve secure, flexible, and efficient electromagnetic protection deployment.