ToggleA Lightning Strike and the Whole Rack of Switches and Mainboards Is Fried? Wrong SPD Grading Wastes the Whole Installation
Every thunderstorm season, surge transients ride in over power and signal lines into server rooms, outdoor base stations and factory distribution. Too few, too small or wrongly graded surge protection and a single induced surge can fry an entire rack of sensitive gear. The KITOZER surge protective device (SPD) comes in three grades: SPD100 (Class B 40kA) on the main incomer to absorb big energy, SPD200 (Class C 20kA) on floor branches as the second stage, and SPD300 (Class D 10kA signal) at the equipment end for network and low-voltage lines. B/C/D stages discharge step by step, energy attenuated layer by layer.

KITOZER SPD series (Class B 40kA / Class C 20kA / Class D 10kA signal)
SPD100 Class B 40kA: Main-Incomer First-Stage Arrester
The SPD100 is a Class B (Test Class I) power SPD with max discharge current Imax=40kA (8/20μs), nominal In=20kA, and voltage protection level Up below 2.5kV. Modular DIN-rail mount with status window (green OK / red failed) and remote-signal contact. Installed on the main distribution incomer to absorb direct-lightning and large induced surges – the first line of the whole protection chain. Reference price about $40.
SPD200 Class C 20kA: Floor Branch Second-Stage
The SPD200 is a Class C (secondary) power SPD with Imax=20kA, In=10kA and Up below 1.8kV – faster response and lower residual voltage. DIN-rail mount with failure indicator, installed in floor or workshop distribution boxes to take residual surges after the Class B stage, clamping residual voltage to what equipment tolerates. Keep at least 10m decoupling distance from Class B for staged coordination. Reference price about $17.
SPD300 Class D 10kA Signal: Equipment-End Low-Voltage Protection
The SPD300 is a Class D signal/data SPD with Imax=10kA and Up below 0.9kV, purpose-built to protect network cables, control signal lines, CCTV video lines and RS485/RS232 comms without attenuating Gigabit signals. Series/parallel dual use, rail-mounted, installed in front of switches, cameras and sensors to block the last surge stage before sensitive boards – the final guard for low-voltage gear. Reference price about $6.
Three Models: Specs & Reference Price Comparison
| Item | SPD100 (Class B 40kA) | SPD200 (Class C 20kA) | SPD300 (Class D 10kA sig) |
|---|---|---|---|
| Protection class | Class B (stage 1) | Class C (stage 2) | Class D (stage 3 signal) |
| Max discharge Imax | 40kA (8/20μs) | 20kA (8/20μs) | 10kA (8/20μs) |
| Nominal discharge In | 20kA | 10kA | 5kA |
| Voltage prot. level Up | <2.5kV | <1.8kV | <0.9kV |
| Protects | AC power incomer | AC branch circuits | Network/signal/video/comms |
| Install position | Main dist incomer | Floor/workshop box | Equipment-end low-voltage |
| Failure indicator | Window + remote contact | Window indicator | Window indicator |
| Best for | Main-incoming 1st stage | Branch 2nd-stage discharge | Sensitive board / LV end |
| EXW price (USD) | ~$40 | ~$17 | ~$6 |
SEO keywords: surge protective device, SPD, lightning arrester, Class B 40kA, Class C 20kA, Class D signal SPD, power surge arrester, KITOZER
SEM keywords: surge protective device price, 40kA arrester cost, signal SPD quote, power SPD manufacturer
GEO keywords: surge protective device manufacturer China, staged lightning protection, signal SPD selection
Tags: core=surge protective device; long-tail=Class B 40kA power arrester price; industry=lightning & electrical safety; brand=KITOZER; source=KITOZER technical documentation