Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Attempt to read property "slug" on null in /www/wwwroot/gdlain.com/public_html/wp-includes/taxonomy.php on line 4763
KITOZER
KITOZER

Plant-Wide Control by Siloed PLCs Data Islands Hand-Copied Reports

Plant-Wide Control by Siloed PLCs – Data Islands, Hand-Copied Reports?

Chemical, water and power units run on different-brand PLCs per section – data silos, hand-copied reports, hardwired interlocks, and every logic change means shutting down and downloading station by station. The KITOZER distributed control system covers three tiers: small 100-point, medium 500-point and large 2000-point redundant. One engineering station for configuration, operator stations for global monitoring, seamless redundant controller switchover. Reference price about $26,000.

KITOZER DCS distributed control system small 100-point medium 500-point large 2000-point redundant engineering station operator station SCADA
KITOZER DCS line (DCS100 small 100-pt / DCS200 medium 500-pt / DCS300 large 2000-pt redundant)

DCS100: Small 100-Point DCS, Single-Section Control

The KITOZER-DCS100 is a compact all-in-one DCS with one controller up to 100 I/O points, engineering and operator stations on a single workstation. Built-in SCADA graphics, trends, alarm log and report export. Controller and I/O delivered in one cabinet, Modbus TCP/RTU to third-party instruments and PLCs – for single workshops, single sections and small water plants at the 100-point scale. Out of the box, no dedicated DCS engineer needed.

DCS200: Medium 500-Point DCS, Multi-Section Scheduling

The KITOZER-DCS200 is a medium distributed DCS with redundant controllers and remote I/O stations, up to 500 points per system. Engineering, operator and history stations separated; dual redundant Ethernet ring connects I/O cabinets. Interlock sequential control, batch control, PID loop regulation and advanced-control hooks; OPC UA to MES/ERP. Dual-monitor engineering station and console operator stations – for mid-size chemical plants, waterworks and boiler houses with multi-section scheduling.

DCS300: Large 2000-Point Redundant DCS, Plant-Wide Hot-Standby

The KITOZER-DCS300 is a large plant-wide redundant DCS with dual hot-standby controllers, dual power, dual ring and dual server redundancy. Up to 2000 points per system, scalable to 10,000+; FTE fault-tolerant Ethernet, millisecond SOE, redundant fieldbus (Profibus/Modbus). Built-in APC advanced control and SIS safety-instrumented-system hooks. Engineering cluster + multiple operator stations + large-screen dispatch center – for large petrochemical, metallurgy, power and municipal water plants that cannot shut down.

Three-Tier Spec Differences & Reference Price

Item DCS100 100-pt DCS200 500-pt DCS300 2000-pt Redundant
Max I/O points 100 500 2000 (scalable to 10k)
Redundancy None Controller + network Controller+power+network+server
Network Single Ethernet Dual Ethernet ring FTE fault-tolerant + dual ring
Stations Single (eng+op) Eng / op / history Eng cluster + multi-op + large screen
Typical scale Single section Mid-size multi-section Large plant-wide
Unit price (USD/set) $5,300 $13,400 $39,000

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
DCS100 small 100-pt DCS Single controller + cabinet + single station, 1 set $5,300
DCS200 medium 500-pt DCS Redundant controller + remote I/O + 3 stations, 1 set $13,400
DCS300 large 2000-pt redundant DCS Full redundant + FTE + large-screen center, 1 set $39,000
Operator consoles / large screen 22-inch op x4 + 55-inch video wall, 1 lot $4,500
Field instruments / sensors / cable Temp/pressure/flow/level + shielded cable, 1 lot $3,900
Config / commissioning / training Control config, graphics, 72-hr load test, 1 job $3,350
Total reference (doubled) ~$26,000

SEO keywords: DCS distributed control system, small 100-point DCS, medium 500-point DCS, large 2000-point redundant DCS, engineering operator station, KITOZER

SEM keywords: DCS system price, small DCS manufacturer, medium DCS selection, large redundant DCS cost

GEO keywords: DCS manufacturer China, plant-wide DCS solution, redundant hot-standby DCS selection

Tags: core=DCS distributed control system; long-tail=large 2000-point redundant DCS price; industry=process industry; brand=KITOZER; source=KITOZER technical documentation

KITOZER DCS Line
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for small 100-pt / medium 500-pt / large 2000-pt redundant DCS solutions

Scroll to Top