Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Attempt to read property "slug" on null in /www/wwwroot/gdlain.com/public_html/wp-includes/taxonomy.php on line 4763
KITOZER
KITOZER

Thermocouple mV Wired to PLC – Cold-Junction Compensation Drifts and Jumps?

Thermocouple mV Wired to PLC – Cold-Junction Compensation Drifts and Jumps?

When plant thermocouple mV outputs and PT100 resistance signals wire directly into PLC analog modules, line voltage drop is large, cold-junction compensation is inaccurate, and frequency pulse signals cannot be connected – data drifts and channels burn. The KITOZER signal converter line covers three tiers: mV-to-mA, PT100-to-4-20mA, and frequency-to-analog, converting field signals to standard 4-20mA for PLC with high accuracy and noise rejection. Reference price about $1,280.

KITOZER signal converter mV to mA PT100 to 4-20mA frequency to analog thermocouple temperature transmitter signal conditioner module
KITOZER signal converter line (CONV100 mV/mA / CONV200 PT100/mA / CONV300 freq/analog)

CONV100: mV to mA, Thermocouple/Millivolt Signal Transmitter

The KITOZER-CONV100 is an mV-to-current converter accepting thermocouple (K/E/J/T/S/B types) or millivolt input with built-in cold-junction compensation, outputting 4-20mA standard signal. Range settable via DIP switch or software, accuracy ±0.2%FS, DIN-rail mount – for furnace temperature, flue gas temperature and other weak mV signal transmission to PLC, eliminating long-line drop errors.

CONV200: PT100 to 4-20mA, RTD Temperature Transmitter

The KITOZER-CONV200 is a PT100/PT1000 RTD-to-current converter supporting 3-wire/4-wire connection with automatic lead-wire resistance compensation. Output 4-20mA corresponding to -200~600°C full range, accuracy ±0.1°C, with LED power and alarm indicators – for HVAC, motor winding, water tank temperature and other PT100 signal standard transmission, directly replacing legacy temperature transmitters.

CONV300: Frequency to Analog, Pulse/RPM Signal to Current

The KITOZER-CONV300 is a frequency/pulse-to-analog converter accepting NPN/PNP passive or active pulse signals, frequency range 0-10kHz (customizable to 0-50kHz), outputting 4-20mA or 0-10V corresponding to frequency range, with pulse counting and frequency measurement – for flowmeter pulses, motor RPM, proximity switch counting and other digital frequency signals to analog for PLC/display.

Three-Tier Spec Differences & Reference Price

Item CONV100 mV/mA CONV200 PT100/mA CONV300 Freq/Analog
Input signal Thermocouple/mV (0-100mV) PT100/PT1000 (3/4-wire) Pulse/frequency 0-10kHz
Output signal 4-20mA 4-20mA 4-20mA / 0-10V
Accuracy ±0.2%FS ±0.1°C ±0.1%FS
Compensation Built-in CJC 3-wire lead comp N/A
Range setting DIP/software DIP/software Software
Typical use Furnace/flue mV HVAC/winding PT100 Flowmeter/RPM pulse
Unit price (USD/pc) $30 $25 $50

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
CONV100 mV-to-mA converter TC/mV input, CJC, 15 pcs $450
CONV200 PT100-to-mA converter PT100 3-wire, lead comp, 20 pcs $500
CONV300 freq-to-analog converter Pulse 0-10kHz, 4-20mA out, 8 pcs $400
DIN rail/shielded/comp cable DIN rail, shielded wire, comp cable, 1 lot $220
Install/wiring/range tuning Rail mount, loop wiring, range set, 1 job $180
Total reference (doubled) ~$1,280

SEO keywords: signal converter, mV to mA converter, PT100 to 4-20mA, frequency to analog, thermocouple temperature transmitter, KITOZER

SEM keywords: signal converter price, mV to mA module cost, PT100 temperature transmitter manufacturer, frequency to analog quotation

GEO keywords: signal converter manufacturer China, PT100 to 4-20mA solution, thermocouple mV signal transmitter

Tags: core=signal converter; long-tail=PT100 to 4-20mA price; industry=industrial temp/flow signal acquisition; brand=KITOZER; source=KITOZER technical documentation

KITOZER Signal Converter Line
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for mV-to-mA / PT100-to-4-20mA / freq-to-analog solutions

Scroll to Top