Table of Contents
Technical Design Proposal for the 144-Core Outdoor Floor-Standing Stainless Steel Fiber Optic Cross-Connection Cabinet
Design Unit: Guangzhou Lain Intelligent System Development Co., Ltd.
Brand: KITOZER (开拓者)
Version: V1.0
—
Table of Contents
- Company Profile
- Project Overview
- User Requirements Analysis
- Design Description
- Quotation & Configuration List
- Product Technical Parameters by System
- Solution Advantages
- Construction Schedule
- Construction Organization Plan
- After-Sales Service System
- Training Plan
- Engineering Case Studies
- SEO Optimization System
- Technical Q&A by Category
- Contact Information
—
1. Company Profile
Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-technology enterprise specializing in the R&D, production, sales, and engineering services of data center infrastructure, communication physical connection equipment, and intelligent computer room products. The company’s core brand is KITOZER.
With more than two decades of industry experience, the company focuses on core product lines including computer room construction, shielded room engineering, integrated data cabinets, micro-module cold-aisle containment systems, outdoor communication cabinets, shielded cabinets, and control consoles. The company possesses comprehensive capabilities for delivering green, innovative, safe, and efficient data center total solutions, and can provide customized solutions tailored to the specific needs of different industries and application scenarios. To date, the company has completed over a thousand successful projects serving communications, government affairs, finance, healthcare, education, industrial manufacturing, and many other sectors.
The company operates a modern production base with a professional R&D team, featuring flexible customized manufacturing capabilities covering the entire process from sheet metal fabrication and surface treatment to complete assembly and performance testing — all under full in-house control. Products are manufactured in strict compliance with national and industry standards, backed by a comprehensive quality control system and certified by third-party authoritative testing institutions, with multiple product patents and high-technology qualifications. With consistent product quality, rapid delivery capability, and professional technical services, the company has earned high recognition from numerous domestic and international enterprises and end users.
Adhering to the business philosophy of “Quality First, Innovation Driven, Service Supreme,” the company leverages over 20 years of industry expertise and technological accumulation to continuously iterate product technology. Closely following national strategic directions such as 5G, computing power networks, and the “East Data West Computing” initiative, the company consistently introduces products and solutions adapted to next-generation communication and computing infrastructure. In terms of service, the company has established a 24-hour professional online service mechanism, enabling rapid response to customer needs and efficient resolution of complex issues, with dedicated personnel tracking the entire project lifecycle — from solution design and manufacturing to installation commissioning and after-sales maintenance. For customization, the company provides tailored design services based on customer site conditions, functional requirements, and brand image, offering multiple design proposals free of charge for customer selection, ensuring products are highly matched to application scenarios and enhancing overall project quality.
—
2. Project Overview
2.1 Industry Background
With the deep coverage of 5G mobile communication networks, the comprehensive rollout of Gigabit Fiber-to-the-Home (FTTH), and the rapid advancement of smart city and industrial internet applications, the demand for fiber-optic, high-density, and outdoor deployment in communication access networks continues to grow. As a core node device in the optical access cable network, the fiber optic cross-connection cabinet performs essential functions including the connection, scheduling, fusion splicing, termination, and test management between backbone and distribution optical cables — serving as an indispensable physical infrastructure component in fiber optic communication networks.
Outdoor fiber cross-connection cabinets are exposed to natural environments over extended periods, facing multiple challenges including extreme temperatures, rain, dust, salt spray, condensation, and external force damage, placing exceptionally high demands on cabinet enclosure protection, corrosion resistance, structural strength, and environmental adaptability of internal optical components. Traditional painted steel cabinets are prone to corrosion, coating peeling, and seal failure in harsh outdoor environments, resulting in short service life and high maintenance costs — no longer meeting the requirements for long-cycle stable operation. Stainless steel outdoor cross-connection cabinets, with their superior corrosion resistance, high structural strength, and longevity advantages, are increasingly becoming the mainstream choice for outdoor deployment by telecom operators and private network customers.
2.2 Project Objectives
This project addresses the outdoor communication access network deployment requirements by providing a comprehensive 144-core outdoor floor-standing stainless steel fiber optic cross-connection cabinet solution. The solution encompasses all-dimensional design including cabinet structure design, fusion distribution unit configuration, cable routing management systems, sealing and protection systems, and grounding and lightning protection systems, accompanied by a complete construction organization plan and after-sales service system. The solution strictly complies with national and communication industry standards, ensuring high reliability, high safety, and easy maintainability in complex outdoor environments. It fully satisfies the fusion splicing, termination, scheduling, and management requirements for 144 fiber cores, providing solid physical-layer assurance for the stable operation of communication networks.
2.3 Applicable Scenarios
The 144-core outdoor floor-standing stainless steel fiber optic cross-connection cabinet designed in this solution is applicable to the following scenarios:
- Outdoor optical node deployment for telecom operators (China Telecom, China Mobile, China Unicom, etc.) — including 5G base station access and FTTH fiber-to-the-home networks
- Outdoor fiber aggregation nodes for private network communication systems — including government networks, public security surveillance networks, and traffic monitoring systems
- Outdoor cross-connection nodes for fiber access networks in industrial parks, university towns, and large residential communities
- Outdoor communication network deployment in coastal high-salt-fog areas, high-humidity high-temperature regions, and dust-prone areas
- Communication optical cross-connection node construction along municipal roads, expressways, and railway lines
—
3. User Requirements Analysis
3.1 Core Capacity Requirements
The equipment must support fusion splicing and termination functions for 144 fiber cores, meeting the fiber core connection and scheduling requirements between backbone and distribution optical cables. It must be compatible with single-mode G.652D fiber applications, support mainstream fiber optic connector types including SC and FC, and provide flexibility for future capacity expansion and functional module upgrades. The internal modular design supports on-demand adjustment of fusion distribution unit quantities, accommodating phased construction with varying core counts.
3.2 Outdoor Environmental Adaptation Requirements
The equipment is designed for fully outdoor installation and must possess excellent waterproof and dustproof performance with an ingress protection rating of no less than IP65. It must operate reliably across a wide temperature range of -40°C to +60°C, feature anti-condensation design to prevent internal condensation caused by day-night temperature differentials, and use a stainless steel enclosure with strong corrosion resistance suitable for harsh outdoor environments including coastal salt spray, industrial acid rain, and high humidity/high temperature conditions. The expected normal outdoor service life is no less than 20 years.
3.3 Structural and Safety Requirements
The cabinet adopts a floor-standing installation structure with sufficient mechanical strength to withstand outdoor wind loads, snow loads, and minor external impacts, with a wind resistance rating of no less than Force 12. It must be equipped with anti-theft locks and tamper-resistant structures to reduce risks of vandalism and theft. A comprehensive grounding system shall be provided, supporting dual grounding of both the optical cable metallic strength members and the cabinet body, meeting lightning protection and electrical safety requirements. All non-metallic materials must use flame-retardant materials to satisfy fire safety requirements.
3.4 Construction and Maintenance Requirements
The internal design shall adopt modular and standardized construction with independently removable and installable fusion distribution units, facilitating on-site construction and later maintenance. The internal cable routing layout must be clear and well-organized, featuring comprehensive fiber routing management and storage structures to ensure fiber bending radius meets standard requirements and minimizes transmission loss. The cabinet must provide sufficient operating space with a large door opening angle, facilitating fusion splicing, patching, and inspection operations by construction personnel. Equipment identification shall be clear and standardized to facilitate fiber core resource management and maintenance record keeping. Wear parts must be universal in specification, easily replaceable, and cost-effective for later maintenance operations.
3.5 Quality and Service Requirements
Products must comply with relevant national and industry standards, pass testing and certification by authoritative institutions, and be accompanied by complete technical documentation and test reports. Professional construction guidance and technical support shall be provided. A comprehensive after-sales service system shall be established with timely fault response and adequate spare parts supply. Maintenance personnel training services shall be provided to ensure customers have the capability for independent routine maintenance and fault troubleshooting.
—
4. Design Description
4.1 Design Basis
This solution strictly follows the following national and industry standards for design and production:
| Standard No. | Standard Title |
| — | — |
| YD/T 988-2015 | Communication Optical Cable Cross-Connection Cabinet (通信光缆交接箱) |
| GB/T 18899.1-2017 | All-Dielectric Self-Supporting Optical Cables — Part 1: General |
| GB 4208-2017 | Degrees of Protection Provided by Enclosures (IP Code) |
| GB/T 2423 Series | Environmental Testing for Electric and Electronic Products |
| YD/T 2000-2014 | General Technical Requirements for Outdoor Communication Cabinets |
| GB 50689-2011 | Code for Design of Lightning Protection and Earthing Engineering for Telecommunication Stations |
| GB/T 38734-2020 | Technical Requirements and Test Methods for Communication Optical Cable Cross-Connection Cabinets |
| YD/T 1272.3-2005 | Optical Fiber Connectors — Part 3: SC Type |
| YD/T 1272.1-2013 | Optical Fiber Connectors — Part 1: FC Type |
| GB/T 51242-2017 | Engineering Design Standard for Synchronous Optical Network |
| — | Customer-provided site environment and functional requirements documentation |
4.2 Design Principles
4.2.1 Reliability Principle
The solution is designed with long-term stable operation as the core objective. All critical components are selected from industrial-grade, outdoor-rated products with sufficient performance margin reserved for key specifications. The cabinet structure and sealing systems undergo multiple environmental test validations to ensure no performance failure occurs under extreme outdoor conditions. Optical component performance complies with industry standards to guarantee stable fiber optic transmission. The grounding system design meets lightning protection requirements to safeguard both equipment and personnel.
4.2.2 Advanced Technology Principle
The design adopts modular, integrated fusion distribution units combining fusion splicing, fiber storage, termination, and scheduling functions — consistent with the mainstream technology direction of current cross-connection cabinets. The stainless steel cabinet body is manufactured using CNC bending and argon arc welding processes, achieving high structural precision and superior surface quality. A polymer waterproof breathable valve technology effectively resolves outdoor temperature-differential condensation issues. The internal cable routing adopts a zoned layout with clear fiber routes, facilitating management and maintenance.
4.2.3 Safety Principle
The structural design meets mechanical strength and anti-theft/tamper-resistance requirements, with a three-point linkage locking mechanism combined with a stainless steel body providing excellent vandal resistance. A comprehensive grounding and lightning protection design ensures the optical cable strength members and cabinet body are uniformly grounded, effectively dissipating lightning-induced currents. All non-metallic materials achieve UL94-V0 flame-retardant rating with self-extinguishing properties, reducing fire hazards. Fiber routing strictly follows bending radius requirements, ensuring optical transmission safety and preventing fiber damage.
4.2.4 Scalability Principle
The internal design utilizes a standard stacking installation structure with standardized fusion distribution unit dimensions, allowing flexible adjustment of core counts or addition of functional modules such as optical splitters and wavelength division multiplexers as future needs arise. Cable entry holes reserve sufficient margin to support future additional optical cable installation. Reserved expansion mounting positions inside the cabinet allow for optional installation of intelligent accessories such as temperature/humidity monitoring and smart locks, adapting to future network upgrade requirements.
4.2.5 Easy Maintenance Principle
The cabinet interior features a clear layout with distinct functional zones and sufficient operating space. Fusion distribution trays are rotatable and extractable, facilitating fusion splicing operations and fault handling. Fiber labeling is standardized and uniform, supporting resource management and fault localization. Wear parts such as locks, sealing gaskets, and breathable valves adopt universal specifications for easy replacement without special tools. The cabinet structure is designed with maintenance convenience in mind, allowing routine inspection of core items without complex operations.
4.2.6 Economic Efficiency Principle
While meeting performance and service life requirements, the structural design and material selection are optimized to control total life-cycle costs. Long-life design reduces replacement frequency and minimizes repeat investment. Low maintenance complexity reduces labor costs and downtime. Standardized design improves spare part commonality and reduces inventory costs. The solution achieves a comprehensive optimum between initial project investment and long-term operation and maintenance costs.
4.3 Overall Solution Design
4.3.1 Overall Structure
This solution adopts a floor-standing single-door opening structural design. The cabinet body is primarily constructed of 304 stainless steel and is divided into two main parts: the external cabinet body and internal functional units. The external cabinet body consists of structural components including the shell, door, base, locks, and hinges, providing protection, anti-theft, and installation fixing functions. The internal functional units are arranged from top to bottom into the fusion distribution zone, fiber storage zone, cable entry fixing zone, and grounding zone — each with independent functions and rational layout, ensuring smooth fiber routing and convenient operation.
The cabinet external dimensions are approximately Width 550mm × Depth 320mm × Height 1050mm, with a base height of 200mm and a total installed height of 1250mm, conforming to standard ergonomic dimensions for outdoor cross-connection cabinets and allowing standing operation by construction personnel. The cabinet surface is finished with a brushed texture, presenting a clean and aesthetically pleasing appearance that resists soiling and is easy to clean, suitable for outdoor public area installation environments.
4.3.2 Internal Layout
Upper Fusion Distribution Zone: Twelve (12) layers of 12-core integrated fusion distribution trays are installed, totaling 144 cores. The trays adopt a stacked mounting configuration, with each layer independently rotatable and extractable, enabling fiber fusion splicing, termination, and scheduling functions. The front of each tray houses the adapter panel while the rear accommodates fusion splicing and fiber storage areas, with front-back separation to ensure non-interfering operations.
Middle Fiber Storage and Routing Zone: Vertical main fiber storage drums are installed on the left and right sides of the cabinet interior for coiling redundant patch cords and pigtails. Semi-circular cable management rings are mounted on the vertical posts to guide fiber routing, ensuring a fiber bending radius of ≥30mm to avoid bending losses. Patch cords and pigtails are routed separately to prevent crossing and entanglement.
Lower Cable Entry Fixing Zone: An optical cable stripping and fixing plate with optical cable fixing clamps is installed, supporting both top and bottom cable entry methods for stripping, fixing, and grounding of backbone and distribution optical cables. Multiple sets of cable fixing clamps and rubber grommets accommodate simultaneous entry of multiple backbone and distribution cables, compatible with outdoor cables of Φ8mm to Φ20mm outer diameter. After cable stripping, the loose tubes are positioned and secured by bundle tube fixing seats, preventing tube displacement from pulling fibers and ensuring mechanical stability of fusion splice points. Standardized cable entry holes are reserved at the cabinet base, complete with waterproof cable glands for sealing after cable penetration — balancing construction convenience with protective performance.
An independent grounding zone is established on the inner lower section of the cabinet, featuring a full-length grounding copper busbar that centrally collects grounding leads from the cabinet shell, optical cable metallic strength members, and armor layers. A reserved grounding terminal is provided for direct connection to the external grounding grid, achieving full equipment equipotential bonding, effectively dissipating lightning-induced currents and static charges, and ensuring electrical safety for both equipment and maintenance personnel.
4.4 Protection and Sealing System Design
This solution constructs a multi-layered protection and sealing system for complex outdoor environments, ensuring the cabinet achieves an overall ingress protection rating of IP65 — completely blocking dust ingress and withstanding low-pressure water jets from any direction, suitable for severe weather conditions including rainstorms and dust storms.
Primary Sealing Structure: Integral one-piece EPDM (ethylene propylene diene monomer) foamed rubber sealing gaskets are installed around the door frame perimeter. The gaskets use a continuous foaming process with no splice gaps, offering excellent weather resistance, aging resistance, and elastic recovery capability. Sealing performance remains stable across a temperature range of -40°C to +120°C, with a long-term compression set rate of ≤10%, ensuring a sealing service life of over 10 years. When the door is closed, the three-point locking mechanism applies uniform pressure, causing the gasket to produce uniform compression deformation, forming a continuous sealing barrier that blocks rain and dust intrusion paths.
Cable Entry Sealing Structure: All optical cable entry holes are equipped with nylon waterproof cable glands featuring built-in conical rubber sealing rings. Threaded compression achieves radial sealing between the cable and entry hole, providing reliable sealing performance while accommodating a certain range of cable outer diameter variations. Unused cable entry holes are provided with sealing plugs to maintain overall cabinet sealing integrity.
Air Pressure Balancing Design: A waterproof breathable valve is installed on the cabinet side, employing a high-molecular ePTFE breathable membrane. The membrane allows air passage while preventing liquid water penetration, automatically balancing internal and external air pressure during temperature fluctuations. This prevents negative internal pressure that could cause moisture intrusion and effectively prevents condensation on interior walls caused by temperature differentials, ensuring a dry operating environment for internal optical components and metal structural parts.
Base Protection Design: A sealing baffle is installed inside the floor-standing base. After cable installation, the base cable entry zone is sealed to prevent rodents and insects from entering the cabinet interior to gnaw on cables and pigtails, while also blocking ground water accumulation, moisture, and dust from entering the cabinet through the base.
4.5 Grounding and Lightning Protection System Design
The grounding system is designed in strict compliance with GB 50689-2011 (Code for Design of Lightning Protection and Earthing Engineering for Telecommunication Stations), establishing a comprehensive equipotential grounding system.
Grounding Busbar: Fabricated from T2 purple copper with tin plating, the busbar measures 3mm thick × 30mm wide. The tin-plated surface reduces contact resistance and enhances corrosion resistance. Multiple M6 and M8 terminal holes are provided for cabinet body grounding, optical cable strength member grounding, armor layer grounding, and external grounding main line connection respectively. All connection points are fitted with flat washers, spring washers, and lock nuts to ensure reliable connections.
Optical Cable Grounding: After stripping each optical cable, the metallic strength member and armor layer are reliably connected to the grounding busbar through dedicated crimp terminals, achieving independent grounding for each cable and preventing lightning-induced current crosstalk between cables. The strength member fixing adopts a design separating the insulating fixing seat from the conductive terminal, with sufficient tensile strength in the fixing structure to withstand longitudinal cable tension, preventing fusion splice point breakage from external pulling forces.
Cabinet Overall Grounding: The cabinet shell and base are reliably electrically connected via bridging copper wires, with an overall grounding resistance of ≤4Ω, ensuring the entire cabinet remains in an equipotential state. The grounding terminal is positioned at the lower section of the cabinet in a convenient operating location, complete with clear grounding identification marks for on-site connection to the external grounding grid.
Insulation Protection Design: The grounding system maintains adequate safety distances from internal fiber routing areas. All grounding connection components are provided with insulation protection treatment to prevent grounding current from interfering with fiber optic transmission and to prevent maintenance personnel from accidentally contacting live parts.
4.6 Material Selection Principles
Cabinet Primary Material: The cabinet shell, door, and base are all constructed of SUS304 stainless steel sheet, with door panel thickness ≥1.5mm and side panel, rear panel, and top panel thickness ≥1.2mm. Mounting posts and internal reinforcement components use ≥1.0mm stainless steel sheet or cold-rolled steel with powder coating treatment. 304 stainless steel offers excellent corrosion resistance and oxidation resistance, with tensile strength ≥520MPa, yield strength ≥205MPa, and elongation ≥40%. The high structural strength withstands outdoor wind loads, snow loads, and external impacts, providing a service life of more than 20 years in normal outdoor environments — far exceeding ordinary cold-rolled steel painted cabinets.
Non-Metallic Structural Components: Internal non-metallic parts including fusion distribution trays, fiber storage drums, cable management rings, and optical cable fixing seats are all injection-molded from ABS flame-retardant engineering plastic, achieving UL94-V0 flame-retardant rating with self-extinguishing properties. These components offer good mechanical strength and aging resistance, with an operating temperature range covering -40°C to +85°C, adapting to the temperature variations inside the cabinet.
Optical Components: Fiber optic adapters employ ceramic sleeves and high-precision zirconia ferrules. Single-mode pigtails use G.652D standard single-mode optical fiber. All optical components comply with industry standards, with critical optical indices including insertion loss, return loss, repeatability, and interchangeability all reaching industry premium-grade levels, ensuring stable and reliable optical signal transmission.
Hardware Accessories: Locks, hinges, bolts, nuts, and other hardware accessories are all manufactured from 304 stainless steel, preventing rust and sticking in outdoor environments and improving the overall product service life and reliability.
—
5. Quotation & Configuration List
The following list represents the fully-loaded standard configuration for the 144-core outdoor floor-standing stainless steel fiber optic cross-connection cabinet, including the cabinet body, fusion distribution core components, cable routing management, sealing protection, grounding protection, and installation auxiliary materials — ready for outdoor floor-standing installation and optical cable fusion splicing termination works.
| No. | Component Category | Component Name | Specification/Model | Unit | Qty | Remarks |
| — | — | — | — | — | — | — |
| 1 | Cabinet Body Assembly | Main cabinet shell | 304 stainless steel, 550×320×1050mm, IP65 | Set | 1 | Door panel 1.5mm, side panel 1.2mm, brushed finish |
| 2 | Cabinet Body Assembly | Stainless steel door assembly | 304 stainless steel, with internal reinforcement ribs | Leaf | 1 | Opening angle ≥120°, with door stay device |
| 3 | Cabinet Body Assembly | Floor-standing mounting base | 304 stainless steel frame, height 200mm | Set | 1 | With anchor bolt holes, static load ≥500kg |
| 4 | Cabinet Body Assembly | Three-point anti-theft lock | Outdoor triangle key, upper/lower interlocking bolt points | Set | 1 | 304 stainless steel, with 3 universal keys, rain shield |
| 5 | Cabinet Body Assembly | Stainless steel detachable hinge | 304 stainless steel heavy-duty | Pair | 2 | Top and bottom of door, each pair load capacity ≥50kg |
| 6 | Cabinet Body Assembly | Internal mounting posts | Stainless steel profiles, with standard mounting holes | Pcs | 2 | Symmetrically arranged left and right inside cabinet |
| 7 | Fusion Distribution Core | 12-core integrated fusion distribution tray | ABS flame-retardant, rotatable/extractable, SC type | Pcs | 12 | 12 cores per tray, 12 trays = 144 cores, UL94-V0 |
| 8 | Fusion Distribution Core | SC/UPC single-mode adapter | Ceramic ferrule, single-mode | Pcs | 144 | Insertion loss ≤0.3dB, return loss ≥50dB |
| 9 | Fusion Distribution Core | SC/UPC single-mode pigtail | G.652D, 0.9mm tight buffer, 1.5m | Pcs | 144 | 1 per core, yellow outer jacket |
| 10 | Fusion Distribution Core | Fiber heat-shrink protection sleeve | Φ3.0×60mm, with stainless steel reinforcing pin | Pcs | 144 | 1 per fusion splice point |
| 11 | Cable Routing Components | Vertical main fiber storage drum | ABS flame-retardant, diameter 80mm | Pcs | 2 | Left and right inside cabinet, for coiling redundant patch cords/pigtails |
| 12 | Cable Routing Components | Semi-circular cable management ring | R30mm, flame-retardant plastic | Pcs | 24 | 12 per left/right post, guiding fiber routing |
| 13 | Cable Routing Components | Optical cable fixing clamp | Metal pressure plate + rubber grommet | Set | 8 | Compatible with Φ8~Φ20mm cables, pull-out force ≥500N |
| 14 | Cable Routing Components | Optical cable stripping and fixing plate | Cold-rolled steel, powder coated | Pcs | 2 | 1 each for top and bottom entry zones |
| 15 | Cable Routing Components | Bundle tube fixing seat | Snap-in type, flame-retardant plastic | Pcs | 24 | Secures cable loose tubes, prevents displacement and pulling |
| 16 | Sealing Protection Components | EPDM door frame waterproof gasket | One-piece foamed rubber | Meter | 6 | Full perimeter door sealing, compression set ≤10% |
| 17 | Sealing Protection Components | Waterproof cable gland | PG29, nylon waterproof type | Pcs | 8 | 4 top and 4 bottom entry holes, IP68 sealing |
| 18 | Sealing Protection Components | Base sealing baffle | 304 stainless steel sheet | Pcs | 1 | Seals base cable entry zone, rodent/dust/moisture proof |
| 19 | Sealing Protection Components | Waterproof breathable valve | Polymer ePTFE membrane | Pcs | 1 | Balances air pressure, prevents condensation |
| 20 | Sealing Protection Components | Lock rain shield | Engineering plastic | Pcs | 1 | Protects lock cylinder from rain and dust |
| 21 | Grounding Protection Components | Grounding busbar | T2 copper, tin-plated, 3×30mm | Bar | 1 | Multiple terminal holes, excellent conductivity |
| 22 | Grounding Protection Components | Stainless steel grounding bolt set | M8×20, with flat/spring washers and nuts | Set | 6 | For fixing busbar and grounding conductors |
| 23 | Grounding Protection Components | Strength member fixing terminal | Copper crimp terminal, M4 | Pcs | 12 | Fixes cable metallic strength member, provides electrical connection |
| 24 | Grounding Protection Components | Grounding identification plate | Stainless steel etched | Pcs | 1 | Marks grounding terminal location |
| 25 | Installation Auxiliary Materials | Self-locking nylon cable ties | 4×200mm, flame-retardant UL94-V0 | Pack | 2 | 100 ties per pack, for binding fibers and cables |
| 26 | Installation Auxiliary Materials | Fiber identification labels | Waterproof adhesive, flag type | Sheet | 10 | Marks fiber core number and routing information |
| 27 | Installation Auxiliary Materials | 304 stainless steel expansion bolts | M10×100mm | Set | 4 | Base-to-ground fixing, outdoor anti-rust |
| 28 | Delivery Documentation | Product certificate of conformity | Factory inspection certificate | Pcs | 1 | Includes production date, inspector, model |
| 29 | Delivery Documentation | Installation and operation manual | Installation steps, splicing guide, maintenance instructions | Copy | 1 | Delivered with goods |
Notes:
- The above configuration is the standard SC/UPC fully-loaded configuration. Adapters and pigtails may be changed to FC/UPC, SC/APC, FC/APC types per requirements, with price adjustment accordingly.
- Optional expansion components include optical splitter trays, wavelength division multiplexing modules, smart locks, temperature/humidity sensors, etc.
- The quotation includes factory packaging and transportation insurance. On-site installation, construction works, and civil foundation costs are not included.
—
6. Product Technical Parameters by System
(This section is reserved for detailed technical specification sheets of each sub-system, including enclosure structural parameters, fusion distribution unit optical performance data, sealing system environmental test results, and grounding system electrical characteristics, as provided in the accompanying product datasheets.)
—
7. Solution Advantages
7.1 Superior Material Selection for Longest Service Life
The cabinet body is constructed entirely of SUS304 stainless steel — a material proven to deliver more than 20 years of outdoor service life in demanding environments. Compared with conventional painted cold-rolled steel cabinets that typically suffer from corrosion and coating failure within 5–8 years, the stainless steel construction significantly reduces lifecycle replacement costs and minimizes service interruptions for network operators.
7.2 Comprehensive Environmental Protection
With an IP65 protection rating, EPDM continuous sealing, ePTFE breathable valve pressure balancing, and full anti-condensation design, the cabinet reliably withstands extreme temperature variations from -40°C to +60°C, high humidity, salt spray, sandstorms, and heavy rainfall. This multi-layered protection approach ensures the stable operation of internal optical components under the most challenging climatic conditions — critical for coastal, desert, and tropical deployment regions including Southeast Asia, the Middle East, and Africa.
7.3 Modular Architecture with Future-Proof Scalability
The standardized modular fusion distribution unit design supports flexible capacity configuration from partial to full 144 cores, with future expansion capability for optical splitters, WDM modules, intelligent monitoring, and smart locking systems. This protects customer investment by enabling incremental network upgrades without replacing the cabinet infrastructure.
7.4 project-confirmed Manufacturing with Full Quality Control
As a manufacturer with complete in-house production capabilities — from sheet metal fabrication through surface treatment to final assembly and testing — KITOZER ensures consistent quality, rapid delivery, and cost-effective pricing. Every cabinet undergoes rigorous quality inspection and environmental testing before shipment, providing international buyers with the confidence of project-confirmed sourcing.
7.5 Full Lifecycle Support Services
From technical consultation, custom design, and manufacturing through installation guidance, staff training, and after-sales support, KITOZER provides complete turnkey project services. Our 24-hour online response mechanism and dedicated project tracking ensure that overseas projects in the USA, Europe, Southeast Asia, the Middle East, and Africa receive timely technical support whenever needed.
—
8. Construction Schedule
A preliminary construction schedule for a standard 144-core cabinet project is outlined below. Final schedules will be adjusted based on project scale, site conditions, and customer requirements.
| Phase | Work Content | Duration | Responsible Party |
| — | — | — | — |
| Pre-construction Preparation | Site survey, civil foundation inspection, material preparation | 3–5 working days | Joint |
| Cabinet Installation | Base anchoring, cabinet positioning, leveling and fixing | 1–2 working days | KITOZER engineering team |
| Optical Cable Entry & Stripping | Cable pulling, entry through glands, stripping and fixing | 1–2 working days | KITOZER engineering team |
| Fiber Fusion Splicing | Fusion splicing of all 144 cores, heat-shrink protection | 2–3 working days | KITOZER engineering team |
| Termination & Labeling | Adapter mounting, pigtail termination, fiber labeling | 1–2 working days | KITOZER engineering team |
| Testing & Commissioning | Optical power testing, OTDR verification, grounding resistance test | 1 working day | Joint |
| Acceptance & Documentation | Completion inspection, as-built drawings, documentation handover | 1 working day | Joint |
—
9. Construction Organization Plan
This project adopts a project manager responsibility system, ensuring clear organization, defined responsibilities, and standardized management throughout the construction process.
9.1 Organizational Structure
- Project Manager: Overall coordination, schedule control, quality management, and customer communication
- Technical Lead: Technical solution implementation, construction technical guidance, and quality inspection
- Construction Team: Cabinet installation, optical cable laying, fusion splicing, termination works
- QA/QC Inspector: Process quality inspection, acceptance testing, and documentation
9.2 Construction Quality Assurance Measures
- All construction personnel must hold relevant qualifications and pass technical disclosure before work begins
- All tools and test instruments must be calibrated and within validity periods
- Fusion splicing work must strictly follow standard operating procedures
- Each construction phase must pass quality inspection before proceeding to the next
- Complete construction records must be maintained, including fusion splicing loss records and fiber routing diagrams
9.3 Safety Management Measures
- All personnel must wear safety helmets and appropriate personal protective equipment on site
- Work at height must comply with safety regulations
- Electrical safety procedures must be followed during grounding works
- Fire safety measures must be in place, with fire extinguishers available on site
- Daily safety briefings must be conducted before each work shift
—
10. After-Sales Service System
10.1 Service Commitment
KITOZER provides comprehensive after-sales services covering the entire product lifecycle:
- Warranty Period: 36 months from the date of delivery
- Service Response: 24-hour online technical support, 48-hour response for on-site service (domestic), remote diagnosis and guidance for overseas projects
- Spare Parts: Long-term spare parts supply guaranteed for a minimum of 10 years after product discontinuation
10.2 Service Content
| Service Item | Description |
| — | — |
| Technical Support | Remote and on-site technical guidance for installation, commissioning, and maintenance |
| Fault Response | Rapid response mechanism with dedicated service engineers for fault diagnosis and resolution |
| Routine Inspection | Optional annual inspection service to assess cabinet condition and optical performance |
| Software/Hardware Upgrades | Notification and supply of upgrades for optional intelligent monitoring components |
| Documentation Support | Provision of technical documentation, drawings, and maintenance records as needed |
10.3 Overseas Service Support
For international projects, KITOZER offers:
- Complete English technical documentation and installation guides
- Video-based remote installation guidance and troubleshooting support
- Spare parts express delivery to global destinations
- Coordinated on-site service arrangements through regional partners where available
—
11. Training Plan
11.1 Training Objectives
To ensure the customer’s operation and maintenance personnel can independently perform routine maintenance, fault diagnosis, and basic repair work on the 144-core fiber optic cross-connection cabinet.
11.2 Training Content
| Training Module | Content | Duration |
| — | — | — |
| Product Structure Overview | Cabinet structure, internal layout, functional zones, component functions | 2 hours |
| Fiber Routing & Management | Fiber routing principles, bending radius requirements, storage techniques | 2 hours |
| Fusion Splicing Operations | Fusion splicing procedure, heat-shrink protection, splice loss testing | 4 hours |
| Routine Maintenance | Daily inspection items, cleaning procedures, seal integrity checks | 2 hours |
| Fault Diagnosis & Handling | Common fault types, troubleshooting methods, emergency handling procedures | 3 hours |
| Grounding & Safety | Grounding system inspection, lightning protection checks, electrical safety | 1 hour |
11.3 Training Methods
- On-site hands-on training during project installation and commissioning
- Classroom-style theoretical training with visual aids
- Provision of training manuals and operation videos for reference after training
- Post-training assessment to verify competency
—
12. Engineering Case Studies
With over 20 years of industry experience, KITOZER has completed more than 1,000 successful projects serving a diverse range of industries. Representative applications include:
- Telecommunications: Outdoor fiber cross-connection node deployments for major telecom operators supporting 5G base station access and FTTH network expansion
- Government & Public Security: Fiber aggregation nodes for city surveillance networks and government private networks
- Transportation: Communication infrastructure along highways, railways, and urban road networks
- Education & Industrial Parks: Campus and park fiber access network node deployments
- Financial & Healthcare: Dedicated communication network infrastructure for banking and hospital systems
Specific case details, including customer references and project photographs, can be provided upon request subject to confidentiality agreements.
—
13. SEO Optimization System
As a professional supplier of outdoor communication enclosures and fiber optic infrastructure equipment, KITOZER maintains a strong digital presence to serve global procurement professionals. Our product pages are optimized for key search terms including:
- Fiber optic cross-connection cabinet manufacturer
- Outdoor stainless steel fiber distribution cabinet supplier
- 144-core fiber optic splice closure / ODF cabinet
- FTTH outdoor distribution cabinet factory
- Telecom infrastructure equipment manufacturer China
Our marketing content is available in English to support inquiries from buyers in the USA, Europe, Southeast Asia, the Middle East, and Africa, with responsive communication through our website and direct channels.
—
14. Technical Q&A by Category
14.1 Product Structure
Q: What is the difference between a floor-standing and wall-mounted cross-connection cabinet?
A: Floor-standing cabinets are installed on a base on the ground, suitable for larger core counts (typically 144 cores and above) and provide more internal space for cable management and fusion splicing operations. Wall-mounted cabinets are fixed to walls, suitable for smaller core counts (typically 48 cores or less) where ground space is limited.
14.2 Environmental Protection
Q: Why is stainless steel preferred over painted steel for outdoor cabinets?
A: Stainless steel provides far superior corrosion resistance, particularly in coastal salt-spray environments, industrial pollution areas, and high-humidity regions. Painted steel cabinets typically develop rust and coating failure within 5–8 years outdoors, while stainless steel can exceed 20 years of service life, significantly reducing long-term replacement costs.
Q: How does the breathable valve prevent condensation?
A: The ePTFE membrane allows air to pass through while blocking liquid water. When temperature changes cause pressure differences between the cabinet interior and exterior, the valve equalizes pressure automatically, preventing moisture-laden air from being drawn into the cabinet through seal gaps and preventing condensation on interior surfaces.
14.3 Installation
Q: What foundation is required for the floor-standing cabinet?
A: A flat concrete foundation is recommended, with minimum dimensions matching the base footprint plus 50mm margin on each side. Anchor bolts (M10 expansion bolts provided) must be embedded or drilled for secure fixing. The foundation should be raised above surrounding ground level to prevent water accumulation.
Q: Is it possible to add cables in the future after installation?
A: Yes. Reserved cable entry holes with waterproof glands are provided, and unused holes come with sealing plugs. Additional cables can be routed through these holes without compromising cabinet sealing integrity.
14.4 Maintenance
Q: How often should routine inspection be performed?
A: A general visual inspection is recommended quarterly, checking door sealing, lock operation, and external condition. A comprehensive annual inspection should include checking fiber routing, verifying splice loss where feasible, inspecting grounding connections, and cleaning interior components.
Q: Are replacement parts readily available?
A: Yes. All wear parts including locks, gaskets, glands, and trays are manufactured to universal specifications. KITOZER maintains a spare parts inventory and can ship replacements to global destinations promptly.
—
15. Contact Information
Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER)
- Phone: +86 139 2228 9957 / +86 185 2066 8845 (WhatsApp & WeChat)
- Website: https://gdlain.com
- Address: Huashan Road 5, Shilou Town, Panyu District, Guangzhou, Guangdong, China
For inquiries regarding this 144-core outdoor stainless steel fiber optic cross-connection cabinet or other KITOZER products and services, please contact our sales team directly. We welcome OEM/ODM collaboration, distributor partnerships, and turnkey project cooperation worldwide.