KITOZER
KITOZER

144-Core SMC Outdoor Fiber Optic Cross-Connection Cabinet | KITOZER

KITOZER fiber optic cross-connection cabinet Overall Effect Rendering

Table of Contents

Technical Design Solution — 144-Core Floor-Standing SMC Outdoor Fiber Optic Cross-Connection Cabinet (Fiber CableACConnectBox)

Solution Provider: Guangzhou Lain Intelligent System Development Co., Ltd.

Brand: KITOZER

Date: August 2026

Version: V1.0

—

Table of Contents

  1. Company Profile
  2. Project Overview
  3. User Requirements Analysis
  4. Overall Design Description
  5. Product Configuration & Quotation List
  6. Detailed Technical Parameters of System Components
  7. Core Solution Advantages
  8. Technical Q&A
  9. Construction Schedule
  10. Construction Organization Plan
  11. After-Sales Service System
  12. Technical Training Plan
  13. Typical Engineering Cases
  14. SEO Optimization System & Keyword Layout
  15. Website Backend Configuration
  16. Contact Information

—

1. Company Profile

Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise specializing in the R&D, production and sales of computer room construction and intelligent enclosure solutions. With over two decades of industryDeeply Focused experience, the company has built its own core brand — KITOZER — with a full product portfolio covering micro-module cold-aisle containment, integrated data cabinets, outdoor cabinets, shielded cabinets, shielded computer rooms, containerized data centers, and control consoles.

The company headquarters is located in Shilou Town, Panyu District, Guangzhou, featuring a modern manufacturing base and a dedicated professional R&D team. KITOZER holds core technologies in the construction of high-efficiency, green data centers, and is capable of delivering tailored, fully customized overall solutions for customers across different industries and application scenarios. Supported by a rigorous quality control system, flexible customization production capabilities and a full-process service system, KITOZER products and solutions have been widely deployed in telecommunications, government, financial, education, healthcare, and enterprise campus sectors — earning broad recognition and positive feedback from domestic and international customers alike.

The company consistently upholds the operating philosophy of “Quality First, Innovation Driven, Service Foremost”. Built on more than 20 years of industry experience, we continue to invest in technology R&D and product upgrades, establishing a complete service chain covering solution design, manufacturing, installation, and after-sales maintenance. As a manufacturer, KITOZER provides one-stop services ranging from single-product customization to full turnkey project delivery. All products strictly comply with national and industry standards, and have passed multiple authoritative testing certifications, ensuring stable and reliable operation in complex environments.

In the outdoor telecommunications infrastructure segment, KITOZER has launched a full series of SMC outdoor fiber optic cross-connection cabinets and outdoor integrated cabinets designed for harsh outdoor environments. These products feature high ingress protection, superior weather resistance, anti-theft and anti-corrosion performance, meeting the construction requirements of municipal communications, 5G base stations, Fiber-to-the-Home (FTTH), and security surveillance networks — providing safe and reliable physical support and operational assurance for communication network nodes.

—

2. Project Overview

2.1 Project Background

With the continued nationwide rollout of “Gigabit Optical Network” construction and the deep coverage of 5G networks, fiber optic communication networks are rapidly expanding toward wider coverage areas and denser node deployments. As the critical node equipment connecting backbone optical cables and distribution optical cables, the fiber optic cross-connection cabinet (Fiber CableACConnectBox) performs core functions including cable termination, fusion splicing protection, fiber scheduling, and splitting/expansion — making it an essential infrastructure element for building stable and reliable fiber optic networks.

Outdoor cross-connection cabinets are exposed to natural environments over long periods, facing multiple challenges including high/low temperature cycling, rain and sand ingress, UV radiation, corrosive gases, and external mechanical damage. These conditions place extremely demanding requirements on cabinet materials, protective performance, and internal construction. Traditional metal cabinets suffer from drawbacks such as susceptibility to rust, heavy weight, poor thermal insulation, and vulnerability to lightning strikes — making them inadequate for long-cycle outdoor reliable operation. SMC composite materials, with their excellent electrical insulation, weather resistance, corrosion resistance, and mechanical strength, have gradually become the mainstream material choice for outdoor cross-connection cabinets.

This project addresses outdoor communication node construction requirements by designing and launching a complete 144-core floor-standing SMC outdoor fiber optic cross-connection cabinet solution, providing customers with full-process technical support from product selection, configuration design, to installation and operation/maintenance training.

2.2 Project Objectives

  • Construct safe and reliable outdoor optical cable cross-connection nodes, enabling termination, fusion splicing and flexible scheduling of backbone and distribution optical cables;
  • Adopt SMC composite cabinet construction to achieve IP65 dust-tight and water-resistant protection, ensuring long-term stable operation across a wide temperature range of -40°C to +65°C;
  • Implement modular fusion-splicing and distribution design for convenient installation and routine maintenance, with reserved splitting and expansion capacity to accommodate future network upgrades;
  • Establish comprehensive grounding and lightning protection systems to safeguard equipment and maintenance personnel;
  • Provide a standardized, replicable construction solution that reduces total life-cycle construction and maintenance costs.

2.3 Applicable Scenarios

The 144-core floor-standing SMC outdoor fiber optic cross-connection cabinet designed in this solution is suitable for the following scenarios:

  • Local network optical cable systems and FTTH (Fiber-to-the-Home) projects for telecom operators including China Telecom, China Mobile, and China Unicom;
  • 5G base station fronthaul and backhaul optical cable access nodes;
  • Municipal road and urban utility tunnel communications network construction;
  • Industrial parks, manufacturing zones, and residential community communications network infrastructure;
  • CATV network two-way transformation and security surveillance fiber optic transmission networks;
  • Special outdoor communication nodes in mining areas, factory premises, and port facilities.

2.4 Solution Design Scope

This solution covers the full process scope of the 144-core floor-standing SMC outdoor fiber optic cross-connection cabinet, including overall structural design, internal functional unit configuration, optical performance indicators, protective performance design, grounding and lightning protection design, installation and construction processes, and operation/maintenance specifications. A complete configuration checklist, technical parameters, construction plan, and after-sales support system are also provided.

—

3. User Requirements Analysis

3.1 Core Functional Requirements

Requirement Category Description
— —
Optical cable termination & fusion splicing Support fusion splicing and termination of up to 144 fiber cores, providing reliable splice protection and fixation for cable fibers and pigtails
Fiber scheduling Enable flexible patching and scheduling between backbone and distribution fibers through jumper fibers, supporting route adjustments and service changes
Optical cable fixation & protection Reliably secure and protect incoming cables, preventing cable tension from transmitting to splicing points
Expansion reservation Reserve installation positions for plug-in optical splitters, supporting future PON network splitting expansion without cabinet replacement
Labeling & identification management Provide clear fiber sequence labeling and maintenance record areas for efficient daily operations

3.2 Environmental Adaptability Requirements

  • Outdoor weather resistance: Withstand direct sunlight, UV radiation, rain immersion, and sand/dust exposure with no aging, chalking, or leakage over extended use;
  • Wide temperature operation: Operate stably in both northern low-temperature and southern high-temperature environments without affecting internal optical component performance;
  • Anti-corrosion & anti-rust: Adapt to coastal salt spray and industrial corrosive gas environments with no rusting of metal components over long-term use;
  • Mechanical protection: Withstand a certain degree of external collision and impact, with anti-theft and anti-prying capabilities;
  • Insulation & lightning protection: The cabinet body itself provides insulating properties, complemented by a complete grounding system to reduce lightning strike and strong-electrical intrusion risks.

3.3 Performance Specification Requirements

Parameter Requirement
— —
Optical performance Insertion loss and return loss of fiber links comply with telecommunications industry standards, ensuring signal transmission quality
Ingress protection Overall cabinet protection rating not less than IP65, completely preventing dust ingress and withstanding low-pressure water jets without leakage
Mechanical strength Cabinet withstands specified impact, vibration and static loads without deformation or cracking
Flame retardancy Cabinet body and internal plastic components are flame-retardant, meeting fire safety requirements
Service life Overall service life not less than 20 years in normal outdoor environments

3.4 Operation & Maintenance Requirements

  • Operational convenience: Internal trays feature pull-out and flip-up design, providing ample space for fusion splicing and patching operations without requiring special tools;
  • Cable routing discipline: Independent routing channels and fiber storage areas are provided, keeping patch cords neatly routed to avoid compression and excessive bending;
  • Low maintenance cost: Wear parts can be individually replaced without complete disassembly, ensuring low maintenance costs and high efficiency;
  • Universal compatibility: Adapters, pigtails, and patch cords all use industry-standard interfaces with strong compatibility, making spare parts readily available.

3.5 Safety Protection Requirements

  • Personnel safety: Cabinet body provides excellent insulation with reliable grounding to prevent electric shock risks during maintenance;
  • Equipment safety: Complete lightning protection and grounding system prevents lightning strikes and strong electrical surges from damaging fiber optic links;
  • Anti-theft security: Equipped with dedicated anti-theft lock mechanisms to prevent unauthorized access;
  • Fire safety: All non-metallic materials are flame-retardant to minimize fire risk.

—

4. Overall Design Description

4.1 Design Basis

This solution is designed in strict compliance with the following national and industry standards:

  • YD/T 988-2015 (Communication optical cable cross-connection cabinet)
  • GB 4208-2017 (Degrees of protection provided by enclosure (IP code))
  • GB/T 2423 series (Environmental testing for electric and electronic products)
  • GB/T 5169 series (Fire hazard testing for electric and electronic products)
  • YD/T 1272.3-2018 (Optical fiber patch cords — Part 3: SC type)
  • YD/T 1814-2008 (Technical requirements and test methods for optical cable cross-connection cabinets used in communication lines)
  • GB 50311-2016 (Code for engineering design of generic cabling systems)
  • YD 5206-2014 (Code for construction and acceptance of fiber-to-the-home projects)

4.2 Design Principles

Safety & Reliability: Long-term stable equipment operation is the core priority. All material selections and structural designs place reliability as the foremost criterion, with key components adopting industry-proven solutions to ensure safe operation throughout the entire life cycle.

Environmental Adaptability: Specialized design for complex outdoor environments, enhancing weather resistance, corrosion resistance, water resistance, and lightning protection from multiple dimensions including materials, sealing, and structure.

Economic Practicality: Structural design is optimized while meeting performance requirements to reduce production and construction costs, balancing initial investment with long-term maintenance expenses.

Scalability: Modular, standardized design with reserved expansion space, allowing flexible addition of optical splitters and capacity expansion based on business development, protecting initial investment.

Ease of Maintenance: Full consideration of maintenance operating habits, optimized internal layout and operating space to reduce maintenance difficulty and time costs.

Standardization: All interfaces, dimensions, and performance characteristics comply with national and industry standards, ensuring product universality and compatibility.

4.3 Overall Structural Layout

The 144-core floor-standing SMC outdoor fiber optic cross-connection cabinet adopts a vertical floor-standing structure, divided into three sections: the upper distribution compartment, lower cable entry compartment, and base mounting area — with a single front door design.

Upper Distribution Compartment: The core functional area, featuring 12 layers of 12-core integrated fusion-splicing/distribution trays stacked vertically, forming a total 144-core capacity. Fiber storage columns and cable managers are installed on both sides of the trays for patch cord storage and routing management.

Lower Cable Entry Compartment: Located in the lower portion of the cabinet, equipped with cable fixation plates, grounding copper busbar, and cable entry ports for cable introduction, securement, and grounding.

Base Mounting Area: The bottom support structure of the cabinet, with pre-drilled mounting holes and cable entry apertures for secure bolting to the concrete foundation.

The cabinet adopts a symmetrical left-right layout with clear cable routing paths. Fiber bend radii are controlled throughout, and operating space is ample — a single technician can complete all fusion splicing and patching operations independently.

4.4 SMC Cabinet Body Structural Design

The cabinet body is manufactured from SMC (Sheet Molding Compound) glass fiber reinforced unsaturated polyester material, compression-molded in one piece under high temperature and high pressure. SMC is a high-strength composite material offering multiple advantages including electrical insulation, flame retardancy, corrosion resistance, weather resistance, and light weight — making it the ideal material for outdoor electrical equipment enclosures.

The cabinet body wall thickness is not less than 5mm, with reinforcing ribs at critical load-bearing areas, ensuring overall mechanical strength while minimizing weight. The cabinet seam features a stepped tongue-and-groove design, combined with a full-perimeter foamed EPDM sealing gasket on the door, creating multiple water barrier layers that effectively block rain and sand ingress.

The cabinet exterior is light gray (RAL7035) with a smooth, flat surface. Custom colors and branding are available upon request. A labeling area is reserved on the front of the base for silkscreen printing of equipment identification and maintenance contact information.

4.5 Fusion Splicing & Distribution System Design

The internal fusion splicing and distribution system adopts a stacked configuration of 12-core integrated trays, where each single tray combines fusion splicing, fiber storage, and distribution functions in one unit — the industry-proven mainstream structure for modern cross-connection cabinets.

  • Trays are injection-molded from ABS+PC flame-retardant engineering plastic, offering high strength and excellent self-extinguishing properties;
  • Featuring a dual pull-out + flip-up mechanism, the tray can be extracted and flipped upward 90° for fusion splicing operations without removing the tray — maximising operator convenience;
  • Each tray front panel mounts 12 SC-type adapters for optical fiber active connections;
  • Internal fusion splice holder channels and wrapping spools securely position heat-shrink protected splices, with excess pigtails neatly coiled;
  • All corner transitions use large radius curves, strictly controlling fiber bending radius to not less than 30mm to avoid additional attenuation.

The 12 tray layers are mounted on a guide rail bracket fixed to the cabinet rear panel, with uniform layer spacing. Each tray operates independently without interference.

4.6 Optical Cable Entry and Securement System Design

Optical cables enter through the bottom of the cabinet. The base is pre-drilled with multiple entry ports, sealed via waterproof cable glands. A dedicated cable fixation plate in the lower compartment integrates cable clamping hoops, cable sheath stripping protectors, and grounding terminals.

Upon entering the cabinet, each cable is first securely clamped to the fixation plate via the hoop, which bears the cable tension and prevents pull forces from transmitting to internal fibers. The cable outer sheath is then stripped, with the cut edge protected by a rubber sheath protector to prevent metal edges from scratching fiber jackets. Finally, the cable’s strength members and armor layer are individually connected to grounding terminals to achieve lightning protection grounding.

Each cabinet supports simultaneous entry of up to 6 optical cables, accommodating multi-directional access from backbone and distribution cables.

4.7 Grounding & Lightning Protection System Design

The cabinet incorporates a comprehensive two-tier grounding protection system:

Optical cable metallic component grounding: The strength members and armor layer of each incoming cable are connected through insulated grounding seats to the grounding copper busbar, achieving equipotential bonding while isolating strong-electrical intrusion.

Cabinet protective grounding: A dedicated grounding terminal is provided, connected via grounding cable to the external earth grid with grounding resistance not exceeding 4Ω, providing cabinet shell protective grounding.

The grounding copper busbar is manufactured from T2 oxygen-free copper with tin plating, offering excellent electrical conductivity and corrosion resistance. Through the tiered grounding design, lightning surge overvoltages and induced strong currents are effectively diverted to earth, protecting internal fiber links and maintenance personnel. Additionally, the SMC cabinet body itself is an insulating material — non-conductive and non-inductive to lightning — significantly reducing lightning strike risk compared to metal cabinets.

4.8 Sealing & Waterproofing Design

The cabinet achieves IP65 dust-tight and water-resistant protection through multiple sealing structures:

Sealing Point Method
— —
Door sealing Full-perimeter EPDM (ethylene propylene diene monomer) foamed sealing gasket on the inner door frame, uniformly compressed when closed to form a continuous seal face
Cable entry sealing All cable entry ports fitted with waterproof cable glands that clamp tightly around the cable sheath when tightened
Seam sealing Stepped tongue-and-groove design at cabinet body joints, extending water penetration paths to prevent rain ingress
Lock sealing Lock fitted with waterproof/dustproof protective cover preventing water ingress through the keyhole

Through the synergistic action of these multiple sealing measures, the cabinet completely blocks dust intrusion and withstands low-pressure water jets from any direction without leakage — fully meeting outdoor installation requirements.

4.9 Fiber Routing & Bend Radius Control

Fiber bend radius directly affects transmission performance and service life. This solution incorporates dedicated design measures across the entire link:

  • All internal corners and wrapping spools use R≥30mm large-radius curves, eliminating right-angle bends;
  • Lateral cable managers feature toothed profiles enabling individual patch cord routing, preventing stack-compression-induced micro-bending;
  • Tray internal wrapping spools have diameter ≥30mm, with pigtail coiling radius strictly meeting standard requirements;
  • Cable entry guides prevent small-radius bends when cables enter the cabinet.

Through full-link bend radius management, additional fiber attenuation is kept within standard limits, extending fiber service life.

—

5. Product Configuration & Quotation List

The following list represents the standard fully-configured version of the 144-core floor-standing SMC outdoor fiber optic cross-connection cabinet. All components correspond to the actual structural diagram and can be adjusted according to project requirements.

I. Cabinet Body & Main Structure

No. Component Specification Unit Qty Remarks
— — — — — —
1 SMC cross-connection cabinet body SMC glass fiber reinforced polyester, IP65 protection, 1030×550×310mm, incl. base Set 1 One-piece compression molded, outdoor weather-resistant
2 Base identification panel SMC same material, silkscreen equipment name & contact info Pc 1 Front base mounting

II. Fusion Splicing & Distribution Core Units

No. Component Specification Unit Qty Remarks
— — — — — —
1 12-core integrated fusion/distribution tray ABS+PC flame-retardant, pull-out + flip-up type, SC adapter compatible Pc 12 12-layer stack, total capacity 144 cores
2 SC/APC fiber optic adapter Ceramic sleeve, simplex single-mode, green housing Pc 144 Fully equipped, 12 cores/tray × 12 trays
3 12-core single-mode ribbon pigtail G.652D fiber, SC/APC connector, 1.5m Pc 12 Matched with trays for fusion termination
4 Fiber fusion splice heat-shrink protector Φ3.0mm, stainless steel needle reinforced Pc 144 1 per fiber core
5 Tray guide rail bracket Cold-rolled steel, electrostatic powder coated, 12-position slot Set 1 Mounted on cabinet rear panel
6 Fiber storage wrapping spool ABS flame-retardant, Φ30mm Pc 4 2 left / 2 right, for patch cord storage
7 Side cable manager Toothed plastic routing channel Set 2 1 left / 1 right, organizes patch cord routing

III. Optical Cable Entry & Securement Components

No. Component Specification Unit Qty Remarks
— — — — — —
1 Cable fixation plate Cold-rolled steel powder coated, with fixation posts Pc 1 Installed in lower entry compartment
2 Cable clamping hoop Nylon + metal locking, fits Φ8-20mm cables Set 6 6 entry positions per cabinet
3 Waterproof cable gland Nylon waterproof type, PG21 thread, IP68 Pc 6 Base entry port sealing
4 Cable sheath stripping protector Rubber grommet Pc 6 Protects fiber at cable cut point

IV. Grounding & Lightning Protection Components

No. Component Specification Unit Qty Remarks
— — — — — —
1 Grounding copper busbar T2 copper, tin-plated, M6 studs Bar 1 Collects cable grounding
2 Cabinet grounding terminal M8 stainless steel bolt type Pc 1 External connection to earth grid
3 Insulated grounding seat Insulating base + copper terminal Set 6 Insulated grounding of cable metallic components

V. Door, Lock & Sealing Components

No. Component Specification Unit Qty Remarks
— — — — — —
1 Single door SMC material, with reinforcing ribs, 120° opening Panel 1 Right-hand hinged
2 Anti-theft triangular lock Zinc alloy body, triangular key, with waterproof cover Pc 1 Right side door mounting
3 Stainless steel door hinge 304 stainless steel, detachable type Pair 2 Top and bottom
4 EPDM foamed sealing gasket EPDM foamed, full-perimeter bonded Set 1 Door sealing
5 Door position limiter Plastic limit type Pc 1 Door opening limit, anti-rebound
6 Door inner identification board PVC blank identification panel Pc 1 Records fiber sequence information

VI. Installation & Auxiliary Materials

No. Component Specification Unit Qty Remarks
— — — — — —
1 Expansion anchor bolts 304 stainless steel, M10×100mm Set 4 Cabinet-to-foundation fixing
2 Concrete foundation C25 concrete, 600×400×200mm Base 1 Cast on site
3 Equipment identification silkscreen Outdoor weather-resistant ink screen printing Set 1 Includes equipment name & contact phone

VII. Optional Expansion Components

No. Component Specification Unit Qty Remarks
— — — — — —
1 SC-SC fiber patch cord G.652D single-mode, SC/APC, 3m Pc As required For link scheduling
2 Plug-in optical splitter PLC type, 1×8 / 1×16 optional Pc As required Reserved slot expansion

—

6. Detailed Technical Parameters of System Components

6.1 Cabinet Body System Technical Parameters

6.1.1 SMC Cabinet Body

Parameter Specification
— —
Material composition Glass fiber reinforced unsaturated polyester sheet molding compound (SMC), glass fiber content ≥25%, with UV absorbers and flame retardant additives
Molding process One-piece compression molding at 150°C / 18MPa, no seams or welds, high structural strength
External dimensions Height 1030±5mm, Width 550±3mm, Depth 310±3mm
Wall thickness Body wall ≥5mm, reinforcing rib areas ≥8mm
Mechanical properties Tensile strength ≥120MPa, Flexural strength ≥180MPa, Charpy impact strength ≥15kJ/m², Barcol hardness ≥40
Ingress protection IP65 (per GB 4208-2017), completely dust-tight, withstands low-pressure water jets from any direction
Operating temperature -40°C to +65°C; storage temperature -50°C to +120°C
Weather resistance After 1000h xenon lamp accelerated aging test: no visible discoloration, cracking or chalking; mechanical strength retention ≥85%
Flame retardancy FV-0 rating (per GB/T 5169.16), oxygen index ≥30%, self-extinguishing on flame removal
Insulation properties Insulation resistance ≥1000MΩ, withstand voltage ≥15kV/1min, no breakdown, no flashover
Corrosion resistance After 500h neutral salt spray test: no rust, no coating peeling; resistant to acid, alkali, salt and other corrosive media
Weight Approx. 45kg (excluding internal components)
Color Default light gray (RAL7035), custom colors available
Installation Floor-standing type, base with 4 pre-drilled Φ12mm fixing holes, spacing per industry standard
Service life ≥20 years in normal outdoor environments

6.1.2 Base Identification Panel

Parameter Specification
— —
Material Same SMC molding compound as cabinet body, consistent color and weather resistance
Dimensions Width 450mm, Height 120mm
Marking process Outdoor weather-resistant acrylic ink silkscreen printing, adhesion grade ≥4B
Weather resistance No fading or peeling after 5+ years of outdoor use
Customization Custom content, logos and layouts available per customer requirements

6.2 Fusion Splicing & Distribution Core System Technical Parameters

6.2.1 12-Core Integrated Fusion/Distribution Tray

Parameter Specification
— —
Material ABS+PC flame-retardant alloy plastic, flame retardant rating V-0
Dimensions Length 300mm, Width 200mm, Height 25mm
Rated capacity 12 cores per tray, compatible with SC and FC type adapters
Structure Pull-out + flip-up dual mechanism, pull-out travel ≥120mm, flip angle ≥90°
Positioning With elastic positioning latch, positive locking at both extended and retracted positions, preventing self-sliding
Internal structure Built-in fusion splice channel accommodating 12 heat-shrink protectors, wrapping radius ≥30mm
Mounting Snap-in installation on guide rail bracket, tool-free removal and replacement
Operating temperature -40°C to +85°C
Service life ≥20 years
Insertion/pull-out life ≥1000 cycles without damage

6.2.2 SC/APC Fiber Optic Adapter

Parameter Specification
— —
Type Simplex single-mode SC/APC fiber optic adapter
Sleeve material Zirconia ceramic, hardness HRA≥87, inner bore precision ≤0.001mm
Housing material PBT flame-retardant engineering plastic, green, flame retardant rating V-0
Insertion loss ≤0.2dB, typical value 0.1dB
Return loss ≥60dB (APC 8° angled end face)
Repeatability ≤0.1dB (1000 insertion cycles)
Interchangeability ≤0.2dB (arbitrary interchange of same model)
Mating durability ≥1000 cycles
Tensile strength ≥50N
Operating temperature -40°C to +85°C
Compliance YD/T 1272.3-2018

6.2.3 12-Core Single-Mode Pigtail

Parameter Specification
— —
Fiber type G.652D single-mode fiber
Fiber parameters Mode field diameter 9.2±0.4μm @1310nm, cladding diameter 125±1μm
Attenuation coefficient ≤0.36dB/km @1310nm, ≤0.22dB/km @1550nm, ≤0.20dB/km @1625nm
Dispersion coefficient ≤3.5ps/(nm·km) @1310nm, ≤18ps/(nm·km) @1550nm
Connector type SC/APC, ceramic ferrule, 8° angled end face polish
Pigtail length Default 1.5m, custom lengths 0.5m–5m available
Ribbon configuration 12-core colored ribbon, standard color coding (blue, orange, green, brown, grey, white, red, black, yellow, purple, pink, cyan)
Jacket material PVC or LSZH (low smoke zero halogen) optional
Insertion loss ≤0.2dB
Return loss ≥60dB
Tensile strength Short-term ≥100N, long-term ≥50N
Bending performance At 30mm bend radius, additional attenuation ≤0.05dB @1550nm
Operating temperature -40°C to +85°C

6.2.4 Fiber Fusion Splice Heat-Shrink Protector

Parameter Specification
— —
Structure Three-layer: hot-melt inner tube + stainless steel reinforcing needle + heat-shrink outer tube
Dimensions Diameter Φ3.0mm, length 60mm
Shrink temperature 110°C – 130°C
Shrink ratio 2:1
Tensile strength ≥50N
Bending performance No cracking or fiber breakage at 15mm bend radius
Insulation resistance ≥1000MΩ
Operating temperature -55°C to +125°C
Service life ≥20 years

6.2.5 Tray Guide Rail Bracket

Parameter Specification
— —
Material Premium cold-rolled steel, thickness ≥1.2mm
Surface finish Electrostatic powder coating, off-white, coating thickness 60–80μm
Slot count 12 standard slots, layer spacing 28mm
Mounting Screw-fixed to cabinet rear panel
Load capacity Single slot ≥2kg, overall ≥30kg
Corrosion resistance 500h salt spray test — no rust
Positioning structure Elastic positioning latch per layer, automatic locking when tray fully inserted

6.2.6 Fiber Storage Wrapping Spool

Parameter Specification
— —
Material ABS flame-retardant engineering plastic
Dimensions Diameter Φ30mm, height 80mm
Quantity 4 per cabinet, symmetrically distributed left/right
Function Storage of excess patch cords and pigtails, ensuring fiber bend radius
Mounting Snap-in fastening to cabinet side walls

6.2.7 Side Cable Manager

Parameter Specification
— —
Material Flame-retardant ABS plastic
Structure Toothed routing channel, slot pitch 10mm
Length 700mm
Quantity 2 sets per cabinet, 1 left / 1 right
Function Standardizes patch cord routing paths, prevents tangling and compression

6.3 Optical Cable Entry & Securement System Technical Parameters

6.3.1 Cable Fixation Plate

Parameter Specification
— —
Material Premium cold-rolled steel, thickness ≥1.5mm
Surface finish Electrostatic powder coating, off-white
Dimensions Length 480mm, Width 120mm
Integrated functions Cable fixation posts, grounding terminal positions, excess cable wrapping posts
Securing capacity Up to 6 optical cables simultaneously
Mounting position Lower cable entry compartment

6.3.2 Cable Clamping Hoop

Parameter Specification
— —
Type Nylon locking-type hoop with metal locking plate
Compatible cable diameter Φ8mm – Φ20mm outer diameter
Material Nylon 66 body + 304 stainless steel locking plate
Locking force ≥100N
Operating temperature -40°C to +85°C
Function Secures cable outer sheath, absorbs cable tension, protects fusion splices from pull forces

6.3.3 Waterproof Cable Gland

Parameter Specification
— —
Type Nylon cable waterproof gland
Thread PG21
Compatible cable diameter Φ10mm – Φ18mm outer diameter
Material Nylon PA66 body + rubber sealing elements
Ingress protection IP68 (when tightened)
Flame retardancy V-0 rating
Operating temperature -40°C to +100°C
Mounting Threaded installation in base aperture, with locking nut

6.3.4 Cable Sheath Stripping Protector

Parameter Specification
— —
Material Weather-resistant rubber
Compatible cable diameter Φ8mm – Φ20mm
Function Fits over cable sheath cut point, preventing metal edges from scratching fiber jackets
Mounting Secured to cable fixation plate

6.4 Grounding & Lightning Protection System Technical Parameters

6.4.1 Grounding Copper Busbar

Parameter Specification
— —
Material T2 oxygen-free copper, purity ≥99.95%
Dimensions Width 20mm, thickness 3mm, length 480mm
Surface finish Tin-plated, coating thickness ≥5μm
Grounding studs M6 copper studs, 6 total, spacing 80mm
Resistivity ≤0.017241Ω·mm²/m (20°C)
Current-carrying capacity ≥200A
Function Collects all cable armor and strength member grounding conductors for unified grounding

6.4.2 Cabinet Grounding Terminal

Parameter Specification
— —
Material 304 stainless steel bolt + copper washer
Specification M8 bolt, complete with nut, flat washer, spring washer
Mounting position Lower side of cabinet base
Grounding requirement External grounding cable connection, grounding resistance ≤4Ω
Function Cabinet shell protective grounding, prevents electric shock and lightning damage

6.4.3 High-Voltage Protection Insulated Grounding Seat

Parameter Specification
— —
Structure Insulating base + copper terminal
Insulation material Reinforced nylon
Insulation resistance ≥1000MΩ
Withstand voltage ≥15kV/1min
Terminal material Tin-plated brass
Function Insulated grounding of cable metallic components, isolating strong electrical and lightning surge overvoltages, protecting internal equipment and personnel

6.5 Door, Lock & Sealing System Technical Parameters

6.5.1 Single Door

Parameter Specification
— —
Material Same SMC molding compound as cabinet body
Wall thickness ≥5mm
Opening angle ≥120°
Reinforcement Internal grid-pattern reinforcing ribs for enhanced rigidity
Sealing groove Full-perimeter sealing groove on inner side for gasket fixation
Opening method Right-side lock, left-side hinges, right-hand opening

6.5.2 Anti-Theft Triangular Lock

Parameter Specification
— —
Lock body material Zinc alloy die-cast, chrome-plated finish
Lock cylinder type Triangular universal cylinder, with matching triangular key
Ingress protection IP65, with waterproof/dustproof protective cover
Anti-theft performance Anti-pry, anti-pick design
Service life ≥10,000 opening/closing cycles
Operating temperature -40°C to +85°C
Key interchangeability Keys are interchangeable within the same production batch, facilitating unified maintenance management

6.5.3 Stainless Steel Door Hinge

Parameter Specification
— —
Material 304 stainless steel
Structure Detachable hinge type
Load capacity per hinge ≥20kg
Service life ≥50,000 open/close cycles
Corrosion resistance 1000h salt spray test — no rust
Quantity 2 pairs per cabinet, top and bottom distribution

—

[Remaining sections: Chapter 7 (Core Solution Advantages) through Chapter 16 (Contact Information) will be provided in subsequent installments.]

—

Contact Information:

Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER)

  • Phone: +86 139 2228 9957 / +86 185 2066 8845 (WhatsApp & WeChat)
  • Website: https://gdlain.com
  • Address: Huashan Road 5, Shilou Town, Panyu District, Guangzhou, Guangdong, China

Global Supply Capability: As a manufacturer and turnkey solution provider, KITOZER serves customers across the USA, Europe, Southeast Asia, the Middle East, Africa and worldwide, delivering customized industrial systems for telecommunications, data center, and power infrastructure projects.

—

Document Version: V1.0 | Date: August 2026

Scroll to Top