ToggleTechnical Design Proposal: 45kW Liquid-Cooled Server Rack
Product Model: KITOZER-LC-45kW-42U
Design Organization: Guangzhou Lain Intelligent System Development Co., Ltd.
Brand: KITOZER
Version: V2.0
Date: August 2026
—
Table of Contents
Chapter 1 Company Profile
1.1 Corporate Development History
1.2 Core Business and Product Lines
1.3 Qualifications and Honors
1.4 Manufacturing and R&D Capabilities
Chapter 2 Project Overview
2.1 Industry Background and Development Trends
2.2 Project Construction Objectives
2.3 Scope of Application
2.4 Design Basis and Applicable Standards
Chapter 3 User Requirement Analysis
3.1 Basic Functional Requirements
3.2 Performance Specification Requirements
3.3 Liquid Cooling System Specific Requirements
3.4 Structural and Installation Requirements
3.5 Operation, Maintenance, and Management Requirements
Chapter 4 Overall Design Description
4.1 Overall Design Principles
4.2 System Architecture
4.3 Internal Rack Layout Design
4.4 Liquid Cooling Pipeline Topology
4.5 Safety Redundancy and Reliability Design
Chapter 5 Quotation and Configuration List
5.1 Standard Configuration per Rack
5.2 Optional Value-Added Accessories
5.3 Bulk Project Quotation Notes
Chapter 6 Technical Parameters of System Products
6.1 Rack Main Frame System
6.2 Door and Locking System
6.3 Internal Mounting and Cable Management System
6.4 Manifold Liquid Distribution System
6.5 Packaging and Transport Materials
Chapter 7 Core Advantages of the Solution
7.1 High-Density Heat Dissipation Capability
7.2 Structural Mechanical Reliability
7.3 Liquid Cooling System Safety
7.4 Operational Maintenance Convenience
7.5 Customization and Adaptation Capability
7.6 Green and Low-Carbon Energy Efficiency
Chapter 8 Technical Q&A
8.1 Basic Rack Knowledge
8.2 Liquid Cooling System Technology
8.3 Installation and Construction
8.4 Operation and Maintenance
8.5 Selection and Customization
Chapter 9 Construction Schedule
9.1 Overall Project Cycle
9.2 Work Content and Timeline by Phase
9.3 Key Milestone Control and Deliverables
Chapter 10 Construction Organization Plan
10.1 Project Organizational Structure
10.2 Core Personnel Configuration and Responsibilities
10.3 On-Site Construction Standard Procedure
10.4 Full-Process Quality Control System
10.5 Safety Production Management
10.6 Civilized Construction and Site Management
Chapter 11 After-Sales Service System
11.1 Warranty Service Commitment
11.2 Multi-Level Fault Response Mechanism
11.3 On-Site Service Operation Standards
11.4 Spare Parts Supply Guarantee
11.5 Lifetime Value-Added Services
Chapter 12 Training Plan
12.1 Training Objectives and Audience
12.2 Tiered Training Content System
12.3 Diversified Training Methods and Arrangements
12.4 Training Assessment and Acceptance Criteria
12.5 Training Documentation Deliverables
Chapter 13 Project Case Studies
13.1 Leading AI Computing Center Liquid-Cooled Rack Cluster
13.2 Prestigious University HPC Center High-Density Liquid-Cooled Data Room
13.3 Major Internet Enterprise Edge Data Center
13.4 National Research Institute Liquid Cooling Test Platform
Chapter 14 Search Keywords and SEO Tags
14.1 Full-Category Keyword Matrix
14.2 Complete SEO Tag System
14.3 Internal Link Anchor Text Strategy
Chapter 15 Website Backend Configuration
15.1 Standard Backend Settings
15.2 Advanced Backend Settings
15.3 Search Optimization Settings
Appendix: Company Contact Information
—
Chapter 1: Company Profile
1.1 Corporate Development History
Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a national high-tech enterprise specializing in the research and manufacturing of data center infrastructure. With over two decades of deep engagement in the data center construction and intelligent rack sector, the company has grown from its early standard server racks and shielded racks to a comprehensive product portfolio encompassing micro-module cold aisle containment, integrated data racks, outdoor telecommunication cabinets, containerized data centers, and liquid-cooled data center infrastructure — building full life-cycle products and service capabilities for data center facilities.
Since its inception, the core brand KITOZER has remained committed to technology-driven innovation, closely tracking global data center technology trends. The company has successively launched several generations of rack products tailored to different computing power levels. Against the current backdrop of the explosive growth of AI large models and high-performance computing, and with server power density continuously climbing, the company strategically positioned itself early in the liquid cooling technology sector. A dedicated liquid cooling R&D team was established, overcoming core technical challenges including pipeline sealing, drip-free connections, uniform fluid distribution, and leak protection. This has resulted in a complete liquid-cooled rack product matrix covering 30kW, 45kW, 60kW, and 80kW power segments, complemented by full liquid cooling solutions including CDU (Coolant Distribution Units), outdoor cooling sources, and intelligent monitoring systems.
Through more than 20 years of market cultivation, KITOZER has evolved from a single rack manufacturer into a leading data center total solution provider in China. Our business covers all 31 provinces, municipalities, and autonomous regions nationwide, and extends to overseas markets including Southeast Asia, the Middle East, Africa, and Latin America. To date, we have served over 1,000 customers across government, finance, education, healthcare, internet, and scientific research sectors, completing thousands of data center construction projects — earning a solid reputation and significant brand influence within the industry.
1.2 Core Business and Product Lines
The company’s core business centers on data center infrastructure, organized into four major product series and two project service systems:
Rack Products Series: Comprehensive sheet-metal rack product line including standard network server racks, shielded racks, integrated intelligent racks, outdoor waterproof cabinets, wall-mounted cabinets, console consoles, and video walls — all supporting deep customization to suit diverse industry scenarios.
Micro-Module and Cold Aisle Series: Single-row micro-modules, double-row cold aisle containment systems, intelligent busways, and precision power distribution units enabling rapid deployment and elastic expansion for small and medium-sized data centers.
Liquid Cooling Infrastructure Series: Cold plate liquid-cooled racks, immersion liquid-cooled racks, CDU coolant distribution units, Manifold liquid distributors, outdoor precision air conditioners and cooling towers, and intelligent leak detection monitoring systems — covering complete liquid cooling heat dissipation solutions from single racks to cluster-level deployments.
Data Center Environment Monitoring Series: UPS uninterruptible power supplies, precision air conditioning, environment and power monitoring systems (DCIM), fire protection and security systems — providing comprehensive operational assurance.
Data Center Engineering Services: Integrated turnkey data center services from solution design, detailed design, on-site construction, system commissioning to final acceptance — covering all disciplines including decoration, power distribution, HVAC, fire protection, and monitoring.
Custom R&D Services: Dedicated R&D and production for non-standard racks, special environment data rooms, and customized liquid cooling solutions addressing specific customer requirements — with three sets of design proposals provided free of charge for client selection.
1.3 Qualifications and Honors
The company maintains strict compliance with regulations and prioritizes quality, holding multiple authoritative industry qualifications and certifications:
- National High-Tech Enterprise Certification
- ISO9001 Quality Management System Certification
- ISO14001 Environmental Management System Certification
- ISO45001 Occupational Health and Safety Management Certification
- China Data Center Engineering Grade 1 Qualification
- Electronic and Intelligent Engineering Professional Contracting Qualification
- Dozens of utility model patents and appearance design patents
- Products certified with national mandatory 3C, CE, and ROHS certifications
- China Data Center Technology Innovation Excellence Award
- National Data Center Equipment Industry Quality-Trusted Brand
1.4 Manufacturing and R&D Capabilities
The company’s manufacturing base is located in Panyu District, Guangzhou, featuring modern standard factory floors exceeding 10,000 square meters. Fully equipped with advanced sheet-metal fabrication and testing facilities — including CNC laser cutting machines, CNC press brakes, CNC turret punches, fully automatic electrostatic powder coating lines, argon arc welding stations, pressure testing benches, salt spray test chambers, and CMM coordinate measuring machines — we achieve full in-house production from raw materials to finished products, ensuring controllable capacity and quality.
Production Management: The company implements lean production models with a strict quality management system, executing a “three-inspection system” (self-inspection, mutual inspection, and specialized inspection). Every process has defined operating standards and inspection requirements. Finished products undergo complete inspections covering appearance, dimensions, performance, sealing, and pressure resistance before shipment, ensuring zero-defect delivery.
R&D Capability: The company has assembled a professional R&D team of senior structural engineers, fluid engineers, and electrical engineers — core members each with over a decade of industry experience in data center equipment. Continuously tracking cutting-edge industry technologies, the company invests more than 8% of annual revenue in R&D innovation, iterating product performance and launching new products to meet evolving market demands. For the liquid cooling sector, the company has established a dedicated liquid cooling laboratory capable of conducting pipeline flow resistance testing, heat exchange efficiency testing, seal life testing, and leak simulation testing — providing solid technical support for product reliability.
—
Chapter 2: Project Overview
2.1 Industry Background and Development Trends
With the rapid advancement of artificial intelligence, big data, cloud computing, and high-performance computing technologies, data centers — as the core digital economy infrastructure — are experiencing explosive growth in computing demand. Concurrently, the power density of individual servers continues to climb. Traditional general-purpose servers typically consume 300–500W per unit, with rack-level density commonly at 5–10kW. However, current AI training servers and high-performance computing servers have already surpassed 3kW per unit, some reaching 5–8kW, driving single-rack power requirements to 30kW, 45kW, and beyond.
Traditional air-cooling heat dissipation relies on air convection to carry away heat. Constrained by physical limitations — air specific heat capacity, fan static pressure, and rack ventilation rates — the maximum cooling capacity per rack is approximately 15–20kW. Moreover, under high loads, fan noise and energy consumption rise significantly while local hot-spot issues become prominent, making air cooling inadequate for next-generation high-density computing equipment. In this context, liquid cooling technology — leveraging the significant advantages of high liquid specific heat capacity, superior heat exchange efficiency, low noise, and excellent energy efficiency — has become the mainstream technical approach for high-density data center heat dissipation.
Cold plate liquid cooling, as the most mature and widely deployed liquid cooling solution, installs cold plates on server core chips. Coolant flows through the cold plates to absorb heat, then circulates through in-rack manifolds and external cooling source systems. This achieves single-rack cooling capacities exceeding 45kW with ease, while preserving the rack-mount server deployment form factor. With excellent compatibility with existing data center infrastructure and low retrofit costs, it is the preferred choice for high-density heat dissipation in modern computing centers.
2.2 Project Construction Objectives
This proposal is designed for single-rack 45kW power density application scenarios, developing a dedicated 45kW liquid-cooled server rack. The objectives are to deliver a product with reliable structure, efficient heat dissipation, convenient operation, and safe stable performance. Specific objectives include:
- Cooling Capacity Target: Stably supports 45kW heat dissipation load per rack, meeting the cooling needs of mainstream high-density liquid-cooled servers; server core chip temperatures maintained within reasonable ranges with no local overheating.
- Structural Safety and Reliability: Rack frame provides sufficient load-bearing capacity and structural strength; liquid cooling system is reliably sealed with zero leak risk; overall performance meets requirements for long-term stable data center operation.
- Efficient and Convenient Maintenance: Standardized modular design; servers support rapid hot-swap maintenance; pipeline connections are simple to operate; daily inspection and fault troubleshooting are convenient — reducing operational complexity and cost.
- Standard Compatibility: 19-inch standard rack dimensions, compatible with mainstream rack-mount liquid-cooled servers, seamlessly integrating with existing cold aisle systems, raised floors, and power distribution infrastructure.
- Scalable and Customizable: Supports customized adjustments for different port quantities, interface specifications, and additional functions — adapting to different server brands and project-specific requirements.
2.3 Scope of Application
The 45kW liquid-cooled server rack is applicable to, but not limited to, the following scenarios:
- AI artificial intelligence computing centers and large model training clusters
- High-performance computing (HPC) centers at universities and research institutes
- High-density computing nodes and edge data centers for internet enterprises
- Quantitative trading computing rooms in financial and securities industries
- Government and enterprise classified high-density data rooms (available with shielding structure options)
- Liquid cooling technology testing and validation platforms
The product is compatible with cold plate liquid-cooled servers and supports multiple common coolant media including ethylene glycol water solutions, deionized water, mineral oil, and fluorinated fluids. It adapts to various external cooling source systems such as closed-circuit cooling towers, chillers, and dry coolers.
2.4 Design Basis and Applicable Standards
This proposal strictly adheres to relevant national and industry standards and specifications for design, primarily including:
- GB 50174-2017 (Code for Design of Data Centers)
- GB 50462-2016 (Code for Construction and Acceptance of Electronic Information System Room Engineering)
- GB/T 2887-2011 (Technical Requirements for Computer Room Racks)
- GB/T 30094-2013 (Industrial Enclosures — General Technical Requirements)
- T/CCSA 377-2021 (Technical Specifications for Liquid-Cooled Data Centers)
- T/CDCC 22-2022 (Technical Requirements for Data Center Liquid Cooling Systems)
- GB 4208-2017 (Degrees of Protection Provided by Enclosures — IP Code)
- GB/T 14976-2012 (Seamless Stainless Steel Pipes for Fluid Transport)
- GB 50260-2013 (Code for Seismic Design of Electrical Installations)
- GB/T 10125-2012 (Corrosion Tests in Artificial Atmospheres — Salt Spray Tests)
- GB 4943.1-2022 (Information Technology Equipment — Safety — Part 1: General Requirements)
- GB 50054-2011 (Code for Design of Low Voltage Electrical Installations)
—
Chapter 3: User Requirement Analysis
3.1 Basic Functional Requirements
- Rack Mounting: Provision of standard 42U rack mounting space per 19-inch international standard, compatible with mainstream rack-mount liquid-cooled servers; supplied with sufficient rack screws and mounting accessories.
- Cable Management: Vertical cable managers on the rear with adequate cable routing space and tie points; layered segregation of power and signal cables to prevent cable clutter from affecting heat dissipation and maintenance.
- Physical Protection: Front and rear doors equipped with reliable mechanical locks for enclosed cabinet management ensuring equipment physical security; basic dust and foreign object protection adapted to data center operating environments.
- Supplementary Ventilation: Perforated mesh front and rear doors with adequate ventilation rates to support cooling of residual fan-cooled server components, while enabling visual inspection of internal equipment status.
- Equipment Load Support: Fixed shelves and sliding rails for switches, storage devices, and auxiliary equipment to accommodate diverse equipment installations within the rack.
3.2 Performance Specification Requirements
- Cooling Performance: Maximum cold plate cooling load of 45kW per rack; with supply water temperature at 25°C and flow rate of 120L/min, outlet temperature rise shall not exceed 5°C, meeting server cooling requirements.
- Load-Bearing Capacity: Static uniformly distributed load capacity ≥1600kg; dynamic load capacity ≥1000kg; capable of supporting a fully populated high-density liquid-cooled server load.
- Pressure Rating: Liquid cooling system rated working pressure ≥1.6MPa; test pressure ≥2.4MPa; safety factor of 3× or greater.
- Sealing Performance: Leakage rates for all pipeline connection points, welds, and quick couplings meeting high industry standards; no visible leakage during normal operation; drip-free coolant disconnection during quick coupling insertion/removal.
- Environmental Adaptability: Rack operates stably in data center environments at 5°C–40°C temperature and 30%–80% relative humidity; metal components exhibit good corrosion resistance; non-metal components are flame-retardant.
3.3 Liquid Cooling System Specific Requirements
- Manifold Configuration: Each rack houses one set of Manifold liquid distribution units comprising 2 vertical distribution columns, installed on the left and right sides of the rack rear respectively; each column features 9 distribution ports, totaling 18 liquid distribution outputs per rack, accommodating connections for 9 dual-loop liquid-cooled servers.
- Quick Connection: Server-side distribution hoses utilize drip-free quick couplings supporting one-hand operation and rapid insertion/removal; server replacement requires no line draining, with zero coolant drip during connection/disconnection, and no impact on other servers’ normal operation.
- Leak Protection: Rack base features a stainless steel drip pan covering the entire liquid cooling pipeline area, capturing potential condensation water or minor leakage; drip pan includes drain outlet and leak sensor mounting provisions.
- Pipeline Integration: Supports floor-level supply/return pipeline access from beneath the rack base, or overhead routing options, adapting to different data center pipeline layouts.
- Flow Uniformity: Flow deviation across all ports on distribution columns shall not exceed ±10%, ensuring uniform coolant distribution to every server without thermal shortfall to any unit.
3.4 Structural and Installation Requirements
- Overall Dimensions: Rack external dimensions are 600mm width × 1400mm depth × 2200mm height, compatible with standard 600mm-wide rack data center layouts and mixed deployment alongside conventional air-cooled racks.
- Bayed Installation: Multiple racks can be installed side-by-side with uniform seams and neat appearance; compatible with cold aisle containment systems.
- On-Site Assembly: Racks ship fully assembled with accessories individually packaged; on-site work requires only positioning, main pipeline connection, and power wiring before commissioning — simple installation procedure with high deployment efficiency.
- Grounding Requirements: Rack features a comprehensive grounding system; front/rear vertical rails, side panels, and doors all have reliable electrical continuity and grounding terminals, meeting data center equipotential grounding requirements.
- Transport Adaptation: Packaged dimensions compatible with standard containers and truck transport; adequate transport protection withstands long-distance transit without damage.
3.5 Operation, Maintenance, and Management Requirements
- Serviceability: Routine maintenance requires no special tools; consumable components quickly replaceable; front and rear doors open at wide angles for full internal access enabling convenient operator work.
- Visual Status Indication: Pipeline connection status, valve states, and equipment operation status directly visible without disassembling structural components.
- Fault Localization: System faults such as leakage quickly traceable to the exact point, reducing troubleshooting time; supports installation of leak detection sensors for automatic alarm integration with environment monitoring systems.
- Scalability: Subsequent upgrades may add PDU, intelligent monitoring modules, fire suppression modules, and related accessories; supports port quantity upgrades adaptable to even higher density server deployments.
- Complete Documentation: Delivery includes complete product manuals, operation and maintenance guides, test reports, certificates of conformity, and other technical documentation for routine management use.
—
Chapter 4: Overall Design Description
4.1 Overall Design Principles
This proposal adheres to the following core principles throughout the design process:
- Reliability-First Principle: Stability of core data center equipment is the top priority. All designs prioritize reliability with sufficient safety margins on structural components and multiple sealing protections on the liquid cooling system, eliminating single points of failure that could impact operations.
- Standardization and Compatibility: Strict adherence to 19-inch rack standards, pipeline interface standards, and electrical grounding standards ensures excellent compatibility with mainstream servers and data center infrastructure, reducing customer deployment and integration costs.
- Maintenance-Friendly: Full consideration of maintenance personnel’s daily operational scenarios; optimized structural layout and connection methods reduce the number of maintenance steps, lower operating difficulty, improve maintenance efficiency, and minimize human error risk.
- Modular Design: Core components adopt modular design — manifolds, cable managers, locks, and shelves are all independent modules individually removable and replaceable for convenient future maintenance and upgrades.
- Safety Redundancy: Multiple protective redundancies targeted at risks such as liquid cooling leakage and structural overload — e.g., drip pan + leak detection dual protection; reinforced plate thickness + stiffening ribs dual load-bearing assurance.
- Green and Low-Carbon: Optimized pipeline flow resistance reduces pump energy consumption; enhanced heat transfer efficiency lowers cooling source energy usage; contributes to data center PUE reduction, supporting green data center construction aligned with dual-carbon objectives.
4.2 System Architecture
The 45kW liquid-cooled server rack comprises five major subsystems working in coordination to deliver load support, heat dissipation, management, and protection for high-density liquid-cooled servers:
- Mechanical Load Subsystem: Rack main frame, front/rear doors, side panels, and base assembly provide the physical load foundation, offering installation support and physical protection for all internal equipment and components.
- Liquid Cooling Distribution Subsystem: Vertical distribution columns, distribution hoses, quick couplings, and drip pan form the core cooling pathway, delivering coolant transport and distribution between external cooling sources and server cold plates.
- Mounting Accessories Subsystem: Rack rails, PDU mounting brackets, fixed shelves, sliding rails, and rack screws provide installation and fixation for servers, network equipment, and power distribution devices.
- Cable Management Subsystem: Vertical cable managers, cable rings, and tie points organize power cables, network cabling, and signal wiring in an orderly manner.
- Safety Protection Subsystem: Mechanical locks, grounding system, drip pan, and leak detection provisions protect against physical, electrical, and liquid cooling safety risks.
4.3 Internal Rack Layout Design
The rack depth direction is divided into three functional zones from front to rear, achieving rational segregation of cold/hot zones, pipelines, and cabling:
Front Operation Zone: Located in the front half of the rack (~800mm depth), this is the server installation area. Standard 19-inch mounting rails are positioned here with servers facing forward, enabling front access for power on/off, status viewing, and drive hot-swap operations.
Rear Pipeline Zone: Located on the left and right sides of the rack rear, each side houses one vertical distribution column spanning the full 42U height. Distribution ports face inward for convenient connection to server rear liquid cooling interfaces. The pipeline zone and server area reserve sufficient operating space for hose connection and maintenance.
Center Cable Management Zone: Located at the rear center position, vertical cable managers route server power cables, network cables, and wiring — achieving physical separation of cabling from liquid cooling pipelines to prevent entanglement and facilitate independent maintenance.
The rack base accommodates the drip pan installation, fully covering the rear pipeline zone to catch potential drips. The rack top is pre-drilled for pipeline and cable routing to support overhead utility access.
4.4 Liquid Cooling Pipeline Topology
The rack liquid cooling system adopts a “dual vertical column parallel” topology, designed as follows:
Main Loop: Coolant supplied by the external cooling source enters the left distribution column (supply riser) from the bottom left of the rack. Through individual branch lines, coolant flows into server cold plates. The heat-absorbed coolant exits servers into the right distribution column (return riser) and exits from the bottom right back to the external cooling source, completing the full circulation loop.
Distribution Branches: Each distribution column vertically positions 9 distribution ports corresponding to servers at different U positions. Each port connects one distribution hose to the corresponding server interface. All branches are connected in parallel, ensuring consistent supply water temperature at each server.
Flow Balancing: Distribution column main pipe diameters are significantly larger than branch pipe diameters, incorporating tapered flow channel designs. This ensures uniform flow across ports at different heights, with flow deviation controlled within ±10%, preventing thermal shortfall for upper or lower servers.
Venting and Pressure Measurement: Both distribution columns include vent valve ports and pressure test ports at the top for air evacuation during system charging and for operational pressure monitoring, facilitating routine maintenance and fault diagnosis.
Valve Configuration: Optional shutoff valves on main supply and return ports enable individual rack isolation for maintenance without interrupting cluster operation.
4.5 Safety Redundancy and Reliability Design
- Structural Strength Redundancy: Main vertical rails use 2.0mm cold-rolled steel plate roll-formed construction, 0.5mm thicker than standard racks; load-bearing beams employ stiffening rib reinforcement with static load capacity rated at 30%+ margin, preventing structural deformation under prolonged full-load conditions.
- Pipeline Pressure Redundancy: Liquid cooling system rated working pressure of 1.6MPa with design burst pressure of ≥4.8MPa (3× safety factor); all welds undergo 2.4MPa hydrostatic pressure hold testing with zero leakage.
- Sealing Redundancy: Pipeline connections employ dual-sealing “welding + thread seal” structure; quick couplings feature bidirectional self-sealing with both ends closing simultaneously upon connection/disconnection — even accidental coupling separation does not cause significant leakage.
- Leak Protection Redundancy: Triple protection system of “drip-free couplings + bottom drip pan + leak detection alarm”: normal insertion/removal is drip-free, minor leakage is captured by the drip pan, and environmental monitoring alarms trigger immediately upon reaching alert thresholds — comprehensive multi-dimensional leak risk prevention.
- Electrical Safety Redundancy: Rack overall grounding resistance ≤0.1Ω with equipotential bonding across all metal components; mounting brackets are insulated to prevent potential differences between different devices.
—
Chapter 5: Quotation and Configuration List
5.1 Standard Configuration per Rack
| No. | Component | Specification | Unit | Qty | Remarks |
| —– | ———– | ————— | —— | —– | ——— |
| 1 | Rack Main Frame | 42U, 600×1400×2200mm, high-quality cold-rolled steel, electrostatic powder coating, static load ≥1600kg | Set | 1 | Includes front/rear mounting rails, base, top cover |
| 2 | Single-door Perforated Front Door | 600×2200mm, hex mesh perforation, ventilation rate ≥70%, cold-rolled steel frame | Leaf | 1 | With recessed handle and hinges |
| 3 | Double-door Perforated Rear Door | 1400×2200mm, split double doors, hex mesh perforation, ventilation rate ≥70% | Set | 1 | Includes two leaves, hinges and handles |
| 4 | Mechanical Lock Set | Dedicated anti-theft rack locks, common key, anti-pry latch | Set | 2 | 1 for front door, 1 linked for rear |
| 5 | Rear Vertical Cable Manager | Full 42U height, flame-retardant ABS + metal bracket, layered cable rings | Pcs | 2 | Left and right, one each |
| 6 | Rear Rail PDU Bracket | Compatible with 19-inch rails, cold-rolled steel, powder coated | Set | 2 | For vertical PDU mounting |
| 7 | Rear Column VCDU/PDU Bracket | Heavy-gauge steel plate, load ≥50kg per set | Set | 2 | For liquid distribution units and PDU |
| 8 | Rack Mounting Screw Kit | M6 standard, screws, nuts, flat & spring washers, carbon steel color zinc plated | Set | 40 | For equipment mounting |
| 9 | Rack-Mount Fixed Shelf | 19-inch standard, depth matched to 1400mm rack, load ≥50kg | Pc | 1 | For auxiliary equipment |
| 10 | Server Sliding Rails | 19-inch three-section ball-bearing rails, full extension, load ≥30kg/pair | Pair | 2 | For drawer-style equipment |
| 11 | Manifold Distribution Column | 304 stainless steel, vertical mount, 9 distribution ports per column, rated 1.6MPa | Pcs | 2 | One supply, one return, left & right |
| 12 | Server Distribution Hose | Coolant-resistant rubber + braided reinforcement, length 1.5m, rated 1.6MPa | Pcs | 18 | One per port |
| 13 | Drip-Free Quick Couplings | 304 stainless steel body, FKM seals, bidirectional self-sealing, drip-free insertion/removal | Set | 18 | Each set includes male and female ends |
| 14 | Stainless Steel Drip Pan | 304 stainless steel, one-piece deep drawn, matches rack base, with drain outlet | Pc | 1 | Installed at rack bottom |
| 15 | Complete Packaging Materials | Honeycomb cardboard box + EPE foam edge protectors + strapping bands, moisture and dust resistant | Set | 1 | Includes packaging for all accessories |
5.2 Optional Value-Added Accessories
| No. | Accessory | Specification | Unit | Qty | Remarks |
| —– | ———– | ————— | —— | —– | ——— |
| 1 | Intelligent Leak Detection Sensor | Location-based leak detection cable, with controller, supports environment monitoring alarm | Set | 1 | Installed in drip pan |
| 2 | Rack-Mount Intelligent PDU | 16A/32A, 8/12 outlets, current & voltage monitoring, remote management | Pcs | 2 | Configurable power and outlet count |
| 3 | Rack Temp/Humidity Sensor | High-precision digital display, RS485 communication, environment monitoring integration | Pcs | 2 | 1 front, 1 rear |
| 4 | Baying Connection Kit | Cold-rolled steel, zinc plated, for rack side-by-side joining | Set | 4 | 4 sets per rack bayed |
| 5 | Removable Side Panels | Cold-rolled steel, powder coated, color-matched to rack | Pcs | 2 | Left and right |
| 6 | Main Line Shutoff Valves | 304 stainless steel, threaded connection, 1.6MPa | Pcs | 2 | Supply and return ports |
| 7 | Flow Sensors | Electronic flow meter, monitors main line flow, data upload capable | Pcs | 2 | Supply and return |
| 8 | Extended Distribution Hoses | Length options 2m/3m, same standard hose material | Pcs | As needed | For special installation distances |
5.3 Bulk Project Quotation Notes
- The above pricing is for single-unit standard configuration reference; bulk procurement qualifies for tiered volume discounts. Final pricing subject to official quotation.
- Optional accessories may be added or removed per project requirements, with corresponding price adjustments.
- Quotation includes production, testing, and packaging costs; excludes transportation, on-site installation, and taxes — these may be separately quoted as required.
- Non-standard customized products are quoted individually based on customization complexity and material costs.
- Integrated liquid-cooled data room turnkey projects (including cooling sources, pipelines, monitoring, construction, etc.) are available as package quotations.
—
Chapter 6: Technical Parameters of System Products
6.1 Rack Main Frame System
| Parameter | Specification |
| ———– | ————— |
| Rack Standard | 19-inch international standard, EIA-310-E compliant |
| Mounting Space | 42U |
| External Dimensions (W×D×H) | 600×1400×2200mm |
| Main Column Material | High-quality cold-rolled steel plate, 2.0mm thickness, roll-formed |
| Frame Structure | Welded frame, four-column load-bearing structure |
| Surface Treatment | Environmental electrostatic powder coating, scratch-resistant |
| Coating Thickness | 60–120μm |
| Color | Black (RAL 9004) standard; custom colors available |
| Static Load Capacity | ≥1600kg uniformly distributed |
| Dynamic Load Capacity | ≥1000kg |
| Front/Rear Mounting Rails | Galvanized steel, 2.0mm thickness, U-channel profile, height adjustable |
| Mounting Thread Specification | M6 threaded, square hole design compatible with cage nuts |
| Grounding Resistance | ≤0.1Ω |
| Protection Rating | IP20 (IP54 for optional sealing kit) |
| Operating Temperature | −5°C to +55°C |
| Storage Temperature | −20°C to +70°C |
| Relative Humidity | 30%–80% (non-condensing) |
| Product Standards Compliance | GB/T 2887-2011, GB/T 30094-2013, GB 50174-2017 |
6.2 Door and Locking System
| Parameter | Specification |
| ———– | ————— |
| Front Door Type | Single-leaf, perforated mesh, flush mounted |
| Front Door Dimensions | 600×2200mm |
| Front Door Ventilation Rate | ≥70% (hexagonal mesh, 2.0mm openings) |
| Rear Door Type | Double-leaf, split opening, perforated mesh |
| Rear Door Dimensions | 1400×2200mm (total) |
| Rear Door Ventilation Rate | ≥70% |
| Door Frame Material | Cold-rolled steel plate, 1.5mm thickness |
| Door Panel Material | Cold-rolled steel plate, 1.2mm thickness (perforated area) |
| Door Opening Angle | Front ≥110°, Rear ≥170° |
| Hinge Type | Heavy-duty industrial hinges, removable design |
| Handle Type | Recessed handle, spring-loaded |
| Lock Type | Dedicated anti-theft lock with key locking |
| Lock Features | Anti-pry latch, tamper-resistant |
| Key System | Common key (same key for all doors); different key option available |
| Surface Treatment | Electrostatic powder coating, color-matched to frame |
| Optional Protective Features | Tempered glass front door (for visual inspection); mesh door with air filter |
6.3 Internal Mounting and Cable Management System
| Parameter | Specification |
| ———– | ————— |
| Mounting Rail Profile | U-channel, 19-inch standard width (482.6mm) |
| Mounting Rail Thickness | 2.0mm, galvanized steel |
| U-position Precision | ±0.4mm |
| Square Hole Specification | 9.5×9.5mm, M6 compatible |
| Cage Nut Type | M6 carbon steel, color zinc plated (45# steel) |
| Screw Specification | M6×16mm, flange head |
| Thread Form | Metric standard, fine pitch |
| Adjustable Depth Range | 25mm |
| Fixed Shelf Load Rating | ≥50kg uniformly distributed |
| Sliding Rail Load Rating | ≥30kg per pair, full extension |
| Sliding Rail Type | Three-section ball-bearing slides |
| Vertical Cable Manager Dimensions | 80×50mm cross-section, full 42U height |
| Cable Manager Structure | Flame-retardant ABS brackets + metal support rails |
| Cable Tie Points | ≥1 per 1U per side |
| Cable Ring Material | Flame-retardant engineering plastic, cold-resistant ≥ −30°C |
| PDU Mounting Position | Rear vertical rails, front and rear configurations supported |
| PDU Bracket Load | ≥50kg |
| Grounding Points | Front door, rear door, side panels, base — dedicated grounding terminals |
6.4 Manifold Liquid Distribution System
| Parameter | Specification |
| ———– | ————— |
| Manifold Type | Vertical single-column distribution, supply and return paired |
| Manifold Quantity per Rack | 2 columns (1 supply + 1 return) |
| Distribution Ports per Column | 9 ports |
| Total Distribution Ports per Rack | 18 ports |
| Port Spacing | 2U interval (88.9mm center-to-center) |
| Port Type | Threaded connection, G3/8″ or G1/2″ standard (selectable) |
| Main Pipe Diameter | DN32 (option: DN40) |
| Branch Pipe Diameter | DN10–DN12 |
| Manifold Material | 304 stainless steel |
| Sealing Material | FKM (fluororubber) — ethylene propylene (EPDM) option |
| Rated Working Pressure | 1.6MPa |
| Test Pressure | 2.4MPa |
| Burst Pressure | ≥4.8MPa |
| Connection Type | Welded (main structure) + threaded (branch connections) |
| Flow Uniformity | Port-to-port deviation ≤±10% |
| Supply Water Temperature Range | 15°C–35°C (recommended 18°C–30°C) |
| Recommended Flow Rate | 120L/min at 45kW heat load |
| Max Flow Rate | 160L/min |
| Compatible Coolants | Ethylene glycol water solution (≤35%), deionized water, mineral oil, fluorinated fluids |
| Pipe Material | 304 stainless steel seamless |
| Pressure Test Standard | 100% factory hydrostatic test at 2.4MPa |
| Exterior Finish | Brushed or sanitary polished, oxidation-resistant |
| Vent/Pressure Ports | Top-mounted, both columns |
6.5 Packaging and Transport Materials
| Parameter | Specification |
| ———– | ————— |
| Packaging Type | Full-enclosure honeycomb paper carton |
| Carton Dimensions | 660×1460×2260mm (internal) |
| Edge Protection | EPE expanded polyethylene foam corner guards, 50mm thickness |
| Corner Guard Specification | 20×20×20cm right-angle brackets, density ≥25kg/m³ |
| Anti-Moisture | PE moisture barrier film, double-layer |
| Strapping | PET plastic strapping bands, 16mm width |
| Strapping Quantity | 4 bands (2 longitudinal + 2 transverse) |
| Identification Marks | Warning labels: fragile, upright, stacking limit |
| Loading Support | Palletized base, GIG standard pallet (1200×1000mm) or custom |
| Transport Vibration Resistance | 3G vibration testing, 500km simulated road transport |
| Stacking Capacity | 3 racks high (empty cabinet packaging) |
| Container Compatibility | Standard 20ft/40ft containers — 6 racks per 20ft (estimate) |
| Protection Standard | Meet ISTA 3E international transport testing requirements |
| Waterproof Protection | Full polyethylene film wrapping, moisture-absorbing desiccant added |
—
Chapter 7: Core Advantages of the Solution
7.1 High-Density Heat Dissipation Capability
The 45kW liquid-cooled server rack delivers a 3×+ cooling capacity advantage over traditional air-cooled racks (which typically cap at ~15-20kW). Leveraging the high specific heat capacity of liquid coolant, the system efficiently removes heat from server CPU/GPU cold plates, maintaining chip temperatures within optimal operating ranges even during sustained full-load operation. The dual-column Manifold design with precision flow balancing ensures every server in the rack receives uniform coolant distribution — eliminating the localized hot spots that plague air-cooled environments and enabling data centers to maximize compute density per square meter of floor space.
7.2 Structural Mechanical Reliability
The rack frame is engineered with 2.0mm cold-rolled steel — 0.5mm thicker than industry-standard racks — delivering a static load capacity of ≥1600kg with 30%+ safety margin. Full welding at all frame joints provides superior rigidity and dimensional stability over the operational lifetime. Every rack undergoes rigorous factory testing including load validation, dimensional accuracy inspection, and grounding continuity checks — ensuring structural performance that stands up to the demands of high-density, mission-critical deployments.
7.3 Liquid Cooling System Safety
Safety is engineered into every aspect of the liquid cooling pathway. All wetted components utilize 304 stainless steel and FKM sealing materials with dual-sealing connection structures, rated at 1.6MPa working pressure with a 3× burst safety factor. The triple-layer leak protection system — drip-free quick couplings, stainless steel drip pan, and leak detection alarm provisions — provides comprehensive defense against cooling system failures. Every manifold undergoes 100% factory hydrostatic pressure testing at 2.4MPa, guaranteeing leak-free performance from day one.
7.4 Operational Maintenance Convenience
Designed with maintainers in mind, the rack features tool-free access to all serviceable components. Front and rear doors open at wide angles (≥110° front, ≥170° rear) providing full internal access. The quick-coupling system enables server hot-swap in under 60 seconds without draining pipelines or affecting neighboring servers. Standardized modular components — manifolds, cable managers, brackets — are individually replaceable without specialized tools, dramatically reducing mean time to repair (MTTR) and total cost of ownership.
7.5 Customization and Adaptation Capability
As a manufacturer with in-house R&D and production, we support deep customization to match specific project requirements. Whether adjusting port configurations, interface specifications, rack dimensions, color schemes, or integrating additional features (shielding, specialized cooling, intelligent monitoring), our team delivers tailored solutions efficiently. Custom non-standard rack and liquid cooling configurations are developed through our dedicated engineering team, with three design proposals provided free of charge for evaluation.
7.6 Green and Low-Carbon Energy Efficiency
The 45kW liquid-cooled rack contributes to data center sustainability goals on multiple fronts. The efficient liquid cooling pathway eliminates the need for high-power cooling fans within the rack, reducing server auxiliary energy consumption by up to 40%. Optimized pipeline flow resistance minimizes pump energy requirements at the CDU level. By enabling higher per-rack compute density, the solution reduces facility footprint requirements per kW of IT load, contributing to significant PUE reductions — supporting data center operators in meeting carbon neutrality and sustainability compliance requirements.
—
Chapter 8: Technical Q&A
8.1 Basic Rack Knowledge
Q1: What is the load capacity of this rack?
A: The rack has a static uniformly distributed load capacity of ≥1600kg and a dynamic load capacity of ≥1000kg, supporting fully populated high-density liquid-cooled server configurations.
Q2: Is this rack compatible with standard 19-inch servers?
A: Yes, the rack fully complies with the 19-inch international standard (EIA-310-E), compatible with all mainstream rack-mount servers, switches, and storage devices.
Q3: What is the frame material and surface treatment?
A: The frame is manufactured from high-quality cold-rolled steel with 2.0mm main column thickness, finished with environmental electrostatic powder coating providing excellent corrosion and scratch resistance.
Q4: Can the rack be customized?
A: Yes, we support extensive customization including dimensions, colors, port configurations, additional functions (shielding, monitoring, specialized accessories), and branding options.
8.2 Liquid Cooling System Technical Questions
Q1: What cooling capacity does each rack support?
A: Each rack supports a maximum cooling load of 45kW cold plate heat dissipation. Recommended conditions: supply water temperature 25°C, flow rate 120L/min, temperature rise ≤5°C.
Q2: What is the working pressure rating?
A: The rated working pressure is 1.6MPa with a test pressure of 2.4MPa and a burst pressure of ≥4.8MPa, providing a 3× safety factor.
Q3: What coolants are compatible?
A: Compatible coolants include ethylene glycol water solutions (up to 35% concentration), deionized water, mineral oil, and fluorinated fluids.
Q4: How is flow uniformity ensured across different U positions?
A: The manifold uses larger main pipe diameters relative to branch lines with tapered internal flow channels, ensuring flow deviation of ±10% or less across all 18 ports.
Q5: What happens if a quick coupling is disconnected?
A: The quick couplings feature bidirectional self-sealing design — both male and female sides seal simultaneously upon disconnection, preventing coolant leakage and enabling tool-free server maintenance without draining.
Q6: Can this rack work with different external cooling sources?
A: Yes, the rack is compatible with various external cooling sources including closed-circuit cooling towers, chillers, dry coolers, and CDUs.
8.3 Installation and Construction Questions
Q1: How long does installation take?
A: Racks ship fully assembled. On-site installation requires positioning, connecting main supply/return pipelines, and power wiring — typically completed within 4 hours per rack by qualified technicians.
Q2: Does installation require special tools?
A: No, standard tools are sufficient for rack installation. All liquid cooling connections use threaded fittings with standard wrenches.
Q3: Can racks be installed adjacent to air-cooled racks?
A: Yes, the 600mm width standard dimension enables mixed deployment alongside conventional air-cooled racks within the same row.
Q4: Can this rack support overhead pipeline routing?
A: Yes, the rack top includes pre-configured openings for pipeline and cable routing, supporting both floor-level and overhead pipeline installation modes.
8.4 Operation and Maintenance Questions
Q1: What routine maintenance is required?
A: Routine maintenance includes visual inspection of pipeline connections for leakage, checking manifold pressure readings, and verifying coolant quality parameters. Recommended inspection frequency: monthly.
Q2: How is server hot-swap performed?
A: Disconnect the supply and return hoses via quick couplings (automatic sealing), slide the server out on rails, perform replacement, reconnect hoses — the procedure takes approximately one minute.
Q3: What leak protection measures are in place?
A: The rack features triple protection: drip-free quick couplings for connection safety, a stainless steel drip pan under all pipeline areas, and provisions for leak detection sensors that integrate with environment monitoring systems.
Q4: Is remote monitoring supported?
A: Yes, optional sensors including leak detection, temperature/humidity, and flow monitoring can be integrated with standard environment monitoring systems (DCIM) via RS485/BACnet/Modbus protocols.
8.5 Selection and Customization Questions
Q1: How many servers can each rack accommodate?
A: Each rack accommodates up to 9 dual-loop liquid-cooled servers (18 server liquid cooling connections) with 42U of 19-inch mounting space for servers and networking equipment.
Q2: What port configurations are available?
A: Standard configuration offers 18 distribution ports (9 supply + 9 return). Alternative configurations with different port quantities and interface specifications (G1/4″, G3/8″, G1/2″) are available.
Q3: Can the rack be adapted for higher power densities?
A: Yes, KITOZER offers liquid-cooled rack solutions spanning 30kW, 45kW, 60kW, and 80kW configurations for varying density requirements. Please contact our engineering team for specific requirements.
Q4: What is the ordering lead time?
A: Standard configuration: 15–20 working days. Custom configurations: 25–35 working days depending on complexity. Bulk orders may be expedited based on production capacity.
—
Chapter 9: Construction Schedule
9.1 Overall Project Cycle
The typical project implementation period for 45kW liquid-cooled rack deployment is 30–45 calendar days from order confirmation to site acceptance, broken down as follows:
| Phase | Duration | Description |
| ——- | ———- | ————- |
| Pre-Production Preparation | 3–5 days | Design confirmation, drawing review, production planning |
| Manufacturing & Testing | 15–20 days | Production, quality inspection, factory testing |
| Logistics & Delivery | 5–10 days | Packaging, transport arrangement, site delivery |
| On-Site Installation & Commissioning | 5–8 days | Positioning, pipeline connection, system commissioning |
| Acceptance & Handover | 2–3 days | Joint inspection, documentation handover, training |
Note: Timeline may vary based on project size, site conditions, and customization requirements.
9.2 Work Content and Timeline by Phase
Phase 1: Pre-Production (Days 1–5)
- Final design confirmation and technical clarification
- Approval of shop drawings and production documentation
- Production scheduling and material procurement
- Quality control plan development
Phase 2: Manufacturing (Days 6–25)
- Sheet metal fabrication: cutting, bending, welding
- Surface treatment: degreasing, phosphating, powder coating
- Assembly: frame assembly, door installation, attachment fitting
- Liquid cooling manifold fabrication and testing
- Full-function factory testing per quality standards
Phase 3: Logistics (Days 26–35)
- Protective packaging per transport standards
- Loading and transport arrangement
- Site delivery and incoming inspection
- Damage inspection verification
Phase 4: Installation & Commissioning (Days 36–43)
- Rack positioning and alignment
- Leveling and anchoring
- Main supply/return pipeline connection
- System flushing and air evacuation
- Pressure testing and leak inspection
- Cooling circulation testing and flow verification
Phase 5: Acceptance (Days 44–46)
- Joint inspection with client team
- Full-function performance validation
- Documentation handover
- On-site training session
- Sign-off and project completion
9.3 Key Milestone Control and Deliverables
| Milestone | Confirmation Method | Deliverables |
| ———– | ——————— | ————– |
| Design Confirmation | Customer approval signature | Shop drawings, technical specifications |
| Material Inspection | Incoming Q.C. records | Material certifications, test reports |
| Production Completion | Factory acceptance inspection | Factory test reports, inspection records |
| Pre-Shipment Inspection | Joint or remote inspection available | Complete inspection reports, photo records |
| Site Delivery | Delivery receipt verification | Delivery notes, packing lists |
| Installation Completion | On-site commissioning | Commissioning reports, test data |
| System Acceptance | Joint acceptance inspection | Acceptance certificates, complete documentation package |
| Project Handover | Final coordination meeting | Warranty certificates, operation manuals, training records |
—
Chapter 10: Construction Organization Plan
10.1 Project Organizational Structure
A dedicated project team is established for each project, structured as:
- Project Director: Overall project leadership, resource allocation, client interface
- Project Manager: Day-to-day project execution, schedule control, quality assurance
- Design Engineer: Technical drawing, design modifications, technical support
- Quality Inspector: Quality control process management, inspections and testing
- Installation Team Leader: On-site installation management, technician coordination
- Commissioning Engineer: System testing, adjustment, and optimization
- Safety Officer: Safety compliance, hazard identification, safety training
- Logistics Coordinator: Transport arrangement, on-site delivery, storage management
10.2 Core Personnel Configuration and Responsibilities
| Position | Qualification | Key Responsibilities |
| ———- | ————— | ———————- |
| Project Manager | 10+ years in data center infrastructure projects | Schedule management, coordination, quality assurance, client reporting |
| Senior Design Engineer | 8+ years, mechanical/fluid engineering background | Technical design review, customization drawings, system optimization |
| Manufacturing Supervisor | 10+ years in sheet metal fabrication | Production quality, delivery timelines, manufacturing process control |
| Q.C. Inspector | 5+ years, certified quality inspector | In-process inspection, final inspection, test documentation |
| Installation Lead | 8+ years, certified installer | On-site installation management, installation quality verification |
| Commissioning Engineer | 5+ years, liquid cooling system specialist | System charging, testing, performance validation, troubleshooting |
| Safety Officer | Certified safety management professional | Site safety compliance, hazard assessment, incident prevention |
10.3 On-Site Construction Standard Procedure
- Pre-Arrival Site Survey: Confirm site conditions, access routes, equipment hoisting requirements, and utility connection points
- Equipment Arrival Inspection: Joint inspection of packaging integrity, item-by-item verification against packing lists, damage documentation
- Site Safety Induction: Safety briefing for all installation personnel, site safety rules, and hazard identification
- Positioning and Layout: Final positioning per floor plan, alignment and leveling verification
- Mechanical Installation: Rack positioning, baying connections, anchoring per seismic requirements
- Pipeline Connection: Main supply/return pipeline connection, torque verification, connection inspection
- Electrical Connection: Power wiring, grounding system installation, electrical safety verification
- System Flushing: Pipeline cleaning, air evacuation, system charging with coolant
- Pressure Testing: Hydrostatic pressure test at specified test pressure, leak inspection of all connection points
- System Commissioning: Flow rate verification, temperature performance testing, system parameter adjustment
- Performance Validation: Full-load cooling capacity verification, flow uniformity measurement
- Site Cleanup and Handover: Site cleanup, waste removal, documentation handover to client
10.4 Full-Process Quality Control System
- Incoming Materials: All raw materials enter with certification inspection; incoming Q.C. records maintained for full traceability
- Manufacturing Process: “Three-inspection” system (self, mutual, dedicated inspections) at each production stage
- Pre-Delivery Testing: 100% factory testing including dimensional inspection, pressure testing, sealing verification, load testing, and grounding continuity
- One-Product-One-Certificate: Every product carries unique traceability code linking to complete quality records
- On-Site Verification: Installation quality verified against acceptance checklist; joint commissioning tests with client representatives
- Defect Management: Non-conformance reporting and corrective action procedures; zero-defect delivery objective
- Documentation Control: Complete quality documentation package delivered with each project
10.5 Safety Production Management
- Safety Policy: Compliance with all applicable occupational health and safety regulations
- Protective Equipment: Mandatory personal protective equipment (PPE) for all site personnel
- Electrical Safety: Lockout/tagout procedures for all electrical work; GFCI protection for power tools
- Lifting Operations: Certified rigging equipment and operators for heavy equipment movement
- Hazard Communication: Material Safety Data Sheets (MSDS) for all coolants and chemicals; proper handling training
- Emergency Response: Site-specific emergency response plan; first-aid trained personnel on site
- Incident Reporting: Mandatory incident reporting with corrective action implementation
- Safety Training: Pre-work safety orientation; task-specific safety briefings
10.6 Civilized Construction and Site Management Requirements
- Site Appearance: Clean, organized work areas; equipment and materials stored in designated zones
- Environmental Protection: Dust control measures; containment for any coolant spillage; proper waste disposal
- Noise Control: Low-noise equipment selection; noisy operations scheduled within permitted hours
- Site Access Control: Authorized personnel only; visitor sign-in procedures
- Daily Housekeeping: End-of-day site cleanup; daily waste removal
- Neighbor Considerations: Coordination with facility management on operational scheduling to minimize disruption
—
Chapter 11: After-Sales Service System
11.1 Warranty Service Commitment
- Standard Warranty: 24 months from the date of installation acceptance
- Warranty Coverage: All manufacturing defects in materials and workmanship
- Extended Warranty: Additional 12-month extension available for purchase (36 months total)
- Lifetime Support: Lifetime technical support and spare parts availability commitment
- Response Commitment: Service response guaranteed within specified timelines from fault notification
- Product Liability: Indemnification for direct damages caused by product manufacturing defects during warranty period
11.2 Multi-Level Fault Response Mechanism
| Fault Level | Definition | Response Time | On-Site Arrival |
| ————- | ———— | ————— | —————– |
| Level 1 — Critical | Complete system outage, cooling interruption affecting production | ≤30 minutes remote response | Within 24 hours |
| Level 2 — Major | Significant performance degradation, single rack failure | ≤2 hours remote response | Within 48 hours |
| Level 3 — General | Minor fault, non-critical component failure, performance slightly below spec | ≤4 hours remote response | Within 72 hours |
| Level 4 — Consultative | Technical consultation, preventive maintenance guidance | ≤8 hours remote response | By appointment |
Response times apply to regions within 500km of Guangzhou; remote areas subject to transportation logistics and will be coordinated with the customer.
11.3 On-Site Service Operation Standards
- Service Scheduling: We coordinate a service time window with the customer; arrival confirmed 24 hours in advance
- Arrival Protocol: Technician arrives in uniform with identification; completes check-in procedures at customer site
- Fault Diagnosis: Systematic fault identification with customer’s operations team participation
- Service Execution: Repair or replacement procedures performed per service standards
- Testing & Verification: Post-service functional testing to confirm resolution
- Documentation: Service report provided — including fault description, root cause analysis, actions taken, and recommendations
- Customer Sign-off: Service completion confirmed by customer representative before departure
11.4 Spare Parts Supply Guarantee
- Spare Parts Inventory: Critical components — manifolds, quick couplings, hoses, drip pans — maintained in permanent stock
- Stock Availability: Same-day dispatch for in-stock parts (working days)
- Long-Term Availability: Spare parts guaranteed for minimum 10 years after product discontinuation
- Exchange Service: Swap-out service for major components — replacement shipped before defective unit returns (advanced exchange)
- Overseas Customers: A minimum 2% spare parts ratio recommended for purchased equipment; wholesale supply of consumables available
11.5 Lifetime Value-Added Services
- Product Upgrades: Technical solution suggestions and implementation for performance or feature upgrades
- Software Updates: Free updates for associated monitoring and management software
- Periodic Inspections: Free remote technical inspection of product performance parameters at agreed intervals
- Technical Consultation: Lifetime access to our engineering team for system optimization and expansion planning
- Training Updates: Periodic operation and maintenance training sessions for refresher or personnel changes
- Engineering Support: Dedicated support, including online remote video service and email consultation service
—
Chapter 12: Training Plan
12.1 Training Objectives and Audience
Training Objectives:
- Enable participants to fully understand the 45kW liquid-cooled server rack product structure and working principles
- Develop operator proficiency in daily equipment operations, inspection, and maintenance procedures
- Establish troubleshooting skills for common faults and emergency response handling capabilities
- Ensure a safe and efficient working environment for liquid cooling system operations
Target Audience:
| Category | Training Focus | Prerequisites |
| ———- | ————— | ————— |
| Facility Operations Staff | Basic operations, daily inspection, routine maintenance | Familiar with data center equipment basics |
| Maintenance Technicians | Advanced maintenance, fault diagnosis, component replacement | 2+ years hands-on data center experience |
| Engineering/Management Staff | System design principles, capacity planning, expansion strategy | Data center infrastructure knowledge |
| Safety/Compliance Officers | Safety procedures, coolant handling, emergency response | Safety management awareness |
12.2 Tiered Training Content System
Level 1 — Basic Training (4 hours):
- Product introduction and system architecture overview
- Equipment nomenclature and component identification
- Daily inspection procedures and checklists
- Safety basics for liquid cooling environments
- Basic operations: door opening, server access, visual inspections
Level 2 — Technical Training (8 hours):
- Liquid cooling system principles and fluid dynamics basics
- Manifold system operation and flow management
- Server connection/disconnection procedures with quick couplings
- System pressure management and monitoring
- Common fault identification, diagnosis, and troubleshooting
- Coolant quality management and replacement procedures
Level 3 — Advanced Engineering Training (12 hours):
- Full system design principles and performance calculations
- Capacity planning and system expansion methodology
- Integration with CDU systems and external cooling sources
- Troubleshooting complex multi-system failures
- System optimization and efficiency enhancement techniques
- Emergency response planning and execution
12.3 Diversified Training Methods and Arrangements
| Training Method | Description | Duration | Suitable for |
| —————- | ————- | ———- | ————– |
| Classroom Instruction | Structured theory sessions with visual aids | As scheduled | All levels |
| Hands-On Workshop | Practical equipment operation exercises at our facility | 1–2 days | Level 1–2 |
| On-Site Training | Training conducted at customer installation site | Per project | Level 1–2 |
| Remote Webinar | Online interactive sessions via video conferencing | 2 hours/session | All levels |
| Video Tutorials | Self-paced instructional videos | On demand | Level 1–2 |
| Documentation | Comprehensive written manuals and quick reference cards | Self-study | All levels |
Training Schedule: Training can be delivered prior to system acceptance, during commissioning, or at scheduled intervals post-delivery. On-site training during project commissioning is included with every project.
12.4 Training Assessment and Acceptance Criteria
| Training Level | Assessment Method | Passing Criteria |
| —————- | ——————- | —————— |
| Level 1 — Basic | Multiple-choice written test | ≥80% score |
| Level 2 — Technical | Written test + practical operation assessment | ≥80% written + successful practical demonstration |
| Level 3 — Advanced | Technical presentation + troubleshooting exercise | ≥85% written + demonstrated fault resolution |
All passing participants receive a KITOZER Certified Operator Certificate.
Failed participants may retake the assessment once at no charge.
12.5 Training Documentation Deliverables
| Item | Description | Format | Quantity |
| —— | ————- | ——– | ———- |
| Product Manual | Complete product description and technical parameters | Printed + PDF | 2 sets |
| Operation Guide | Step-by-step daily operating procedures | Printed + PDF | 2 sets |
| Maintenance Manual | Preventive maintenance schedules and procedures | Printed + PDF | 2 sets |
| Troubleshooting Guide | Common faults, diagnosis, and resolution | Printed + PDF | 2 sets |
| Training Presentation | Full training slide deck from sessions | Digital | 1 set |
| Training Videos | Demonstrations of key operational procedures | Digital | 1 set |
| Quick Reference Card | Laminated summary of key operating parameters | Printed | 5 cards |
| Safety Manual | Safety procedures and coolant handling guide | Printed + PDF | 2 sets |
—
Chapter 13: Project Case Studies
13.1 Leading AI Computing Center Liquid-Cooled Rack Cluster
Project Overview: Supply and installation of high-density liquid-cooled rack infrastructure for a major AI computing center in China supporting large language model training workloads.
Scale: 96 units of 45kW liquid-cooled racks (KITOZER-LC-45kW-42U)
Deployment: 4 rows × 24 racks, integrated with cold aisle containment and CDU cooling infrastructure
Project Features:
- Full high-density GPU server deployment — AI training clusters
- Sustained full-load operation with 96 racks × 45kW continuous heat dissipation
- Integration with chilled water cooling system and closed-circuit cooling towers
- Intelligent environment monitoring with centralized management platform
Key Outcomes:
- PUE ≤ 1.15 achieved at full load
- Server inlet temperatures maintained within ±1°C across all racks
- Zero leakage incidents since commissioning
- Deployment completed 15 days ahead of schedule
13.2 Prestigious University HPC Center High-Density Liquid-Cooled Data Room
Project Overview: High-performance computing center expansion at “Project 985” university, accommodating next-generation HPC servers for scientific research applications.
Scale: 32 units of 45kW liquid-cooled racks + 8 units of 60kW liquid-cooled racks
Deployment: Mixed-density deployment with micro-module cold aisle containment
Project Features:
- HPC cluster supporting weather simulation, life sciences, and materials research
- Integration with existing facility cooling infrastructure via CDU systems
- Seismic-engineered mounting per GB 50260-2013 requirements
- Comprehensive monitoring integrated with existing building management system
Key Outcomes:
- Research computing capacity increased 3.2× within existing facility footprint
- Equipment noise levels reduced by approximately 20dB vs. air-cooled configuration
- Faculty and student researchers trained on system operation through hands-on sessions
- Zero liquid cooling safety incidents over two years of operation
13.3 Major Internet Enterprise Edge Data Center
Project Overview: Edge data center deployment for a leading Chinese internet company, supporting high-density edge computing workloads in metropolitan nodes.
Scale: 24 units of 45kW liquid-cooled racks per site × 5 sites
Deployment: Distributed edge nodes across multiple cities
Project Features:
- High-density edge computing nodes — AI inference and content delivery
- Rapid deployment capability: complete site installation in 10 days per location
- Remote monitoring and management integration with centralized operations platform
- Containerized cooling infrastructure for decentralized deployment
Key Outcomes:
- Edge inference latency reduced by 40% vs. centralized architecture
- Standardized deployment model enables repeatable rapid expansion
- Remote operation achieved with minimal on-site staffing requirements
- Cross-site consistency in cooling performance and operational parameters
13.4 National Research Institute Liquid Cooling Test Platform
Project Overview: Dedicated liquid cooling test platform for a national research institute, providing controlled environment for liquid cooling technology validation and evaluation.
Scale: 10 units of 45kW liquid-cooled racks with flexible test instrumentation
Deployment: Modular test configuration with quick-reconfiguration capability
Project Features:
- Multiple coolant media testing capability: ethylene glycol solutions, deionized water, fluorinated fluids
- Precision instrumentation for flow, temperature, and pressure measurement
- Configurable manifold system supporting various server cold plate layouts
- Data acquisition integration for research analysis
Key Outcomes:
- Successfully validated multiple liquid cooling technology approaches
- Completed server cold plate performance benchmarking for next-gen processors
- Detailed flow distribution and thermal performance data published in research papers
- Platform continues to serve as national-level liquid cooling certification test facility
—
Chapter 14: Search Keywords and SEO Optimization Tags
14.1 Full-Category Search Keyword Matrix
Product Core Keywords:
- Liquid-cooled server rack
- 45kW liquid cooling rack
- High-density server cabinet
- Cold plate liquid cooling
- Data center liquid cooling system
Application Keywords:
- AI data center cooling
- HPC liquid cooling solution
- GPU server rack cooling
- High-performance computing cabinet
- Liquid-cooled data center infrastructure
Solution Keywords:
- Turnkey liquid cooling data center
- CDU coolant distribution system
- Manifold liquid distribution rack
- Containerized liquid cooling solution
- Custom liquid cooling rack manufacturer
Trade Keywords:
- Server rack manufacturer China
- Liquid cooling rack project-confirmed
- Data center cooling equipment supplier
- Rack OEM ODM manufacturer
- Infrastructure export supplier
Full-Text Keywords:
- 42U liquid cooling cabinet
- Rack with drip-free quick coupling
- 1.6MPa cooling rack manifold
- 304 stainless steel liquid distributor
- 45kW heat dissipation cabinet
14.2 Complete SEO Tag System
Title Tag:
KITOZER 45kW Liquid-Cooled Server Rack | High-Density Data Center Cooling Cabinet Manufacturer — Guangzhou KITOZER (gdlain.com)
Meta Description:
Discover the KITOZER-LC-45kW-42U liquid-cooled server rack — 45kW cold plate cooling capacity, 42U 19-inch standard, 304 stainless manifold, drip-free quick couplings. Project-confirmed from China’s leading data center rack manufacturer with global export experience. Turnkey liquid cooling solutions available.
Meta Keywords:
liquid cooled server rack, 45kW rack, data center liquid cooling, high density server cabinet, cooling rack manufacturer
14.3 Internal Link Anchor Text Strategy
| Anchor Text | Target Page |
| ————- | ————- |
| Liquid-cooled server rack | Product detail page |
| 45kW cooling capacity | Technical specifications page |
| Manifold CDU system | Liquid cooling system page |
| Data center cooling solution | Solution overview page |
| Rack manufacturer China | About us / factory page |
| High-density data center | Application case studies page |
| Liquid cooling infrastructure | Infrastructure solutions page |
| Custom server racks | Customization service page |
—
Chapter 15: Website Backend Configuration
15.1 Standard Backend Settings
The official website (https://gdlain.com) is configured with the following standard settings to optimize user experience and international lead generation:
- Site Language: English (primary)
- Site Currency: USD (US Dollar) as primary display, CNY available
- Time Zone: GMT+8 (China Standard Time)
- Contact Display: Full contact information on all pages including phone, WhatsApp, email, and address
- Product Showcase: Filterable product catalog by category, power rating, and application
- File Downloads: Technical specifications, brochures, and certifications in PDF format
- Inquiry System: Multi-field inquiry form with product selection and specification inputs
- Responsive Design: Fully mobile-responsive layout for all devices
15.2 Advanced Backend Settings
- Multi-Language Support: Framework in place for additional languages (Spanish, Russian, Arabic) for regional market expansion
- CRM Integration: Lead capture and management system integrated with backend
- Live Chat: Real-time customer service chat application integrated for international time zones
- Analytics: Full web analytics implementation for traffic analysis and conversion tracking
- Content Management: Weekly content publication on applications, case studies, and technical insights
- Performance Optimization: CDN acceleration for global content delivery, especially for markets in USA, Europe, Southeast Asia, Middle East, and Africa
15.3 Search Optimization Settings
- XML Sitemap: Dynamically generated, auto-submitted to Google Search Console and Bing Webmaster Tools
- Structured Data: Schema.org markup for Products, Organization, and Breadcrumbs
- HTTPS Security: Full-site SSL encryption
- Page Speed: Optimized image compression, lazy loading, and caching for fast international access
- Mobile Optimization: Mobile-first indexing compliance
- Local SEO: Google Business Profile for “Guangzhou Lain Intelligent System Development Co., Ltd.” and location-specific pages for international market targeting
—
Appendix: Company Contact Information
Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.
Brand: KITOZER
Address: Huashan Road 5, Shilou Town, Panyu District, Guangzhou, Guangdong, China
Tel / WhatsApp / WeChat: +86 13538869979 / +86 13538869979
Website: https://gdlain.com
Business Hours: Monday–Saturday, 9:00–18:00 (GMT+8)
For overseas project inquiries, technical specifications, and partnership opportunities, we welcome direct contact. Our international sales team responds to all inquiries within 24 hours.