Air-Cooled Containerized Data Center 170kW | KITOZER-CPC Prefab Data Center

170kW Air-Cooled Containerized Data Center | KITOZER-CPC Prefab Modular Data Center

The KITOZER-CPC air-cooled containerized data center is a factory-prefabricated modular data center for high-density AI compute. A dual-container package — 12192mm compute container + 8000mm power container — houses 42U racks for 36 AI servers, 400kVA modular UPS, 350kW diesel genset, 5×60kW in-row CRAH, FM200 gas suppression, and a DCIM platform. Site-ready after external power, network, and crane placement.

Cutaway view of prefabricated containerized data center with server racks

1. Why Containerized?

Traditional concrete server rooms take months to build. The KITOZER-CPC is “factory-prefabricated, site-placed, ready to connect.” All racks, power, UPS, cooling, fire, and monitoring are assembled and tested at the factory; on site only external 10kV feed, network, and anchoring are needed.

2. Architecture

  • Compute container: 12192×3200×2896mm, 50mm rock-wool sandwich, IP55, 4×42U racks (9 servers each), closed hot aisle, raised floor.
  • Power container: 8000×3200×2896mm, HV switchgear, 400kVA dry transformer, LV switchgear, 400kVA modular UPS, LFP battery cabinets, 350kW containerized genset with 12h buried fuel tank.
  • Cooling: 5×60kW in-row CRAH + 2×20kW PAC for power container.
  • Fire: FM200 gas suppression per container (70L×2 cylinders each).
  • Monitoring: DCIM touchscreen + IR dome CCTV.

Modular containerized data center dark exterior with red accent

3. Power Train

10kV incoming → KYN10 HV switchgear → 400kVA dry transformer → GGD LV switchgear → 400kVA modular UPS (4×100kVA modules) → rack PDU. 350kW diesel genset with ATS covers the 15-minute battery backup window. LFP battery cabinets (51.2V/100Ah, 2 sets) provide ride-through.

IP65 outdoor containerized data center enclosure

4. Selection Guide

  • Rack density: ≤15kW per rack → air-cooled; 20kW+ → evaluate cold-plate liquid cooling.
  • Supply voltage: 10kV available → HV incoming + package substation; only 380V → drop HV/transformer and re-rate UPS/genset.
  • Fuel storage: standard 12h; remote sites upgrade to 24–48h.
  • Environment: desert → upgrade condenser; coastal → anti-corrosion coating / 316SS; high altitude → derate transformer and CRAH.
  • Expansion: reserve 20% spare breaker ways and UPS headroom for future compute containers.

Dual outdoor integrated smart cabinet row

5. Reference Price

Complete 170kW IT-load infrastructure (servers/switches excluded): RMB ~¥8,519,600/set (~USD 1,183,000). Bulk or phased projects negotiable.