I. Product Overview

image

AL Automatic Fire Alarm System Complete Unit

2. Core Values

  • Early warning to eliminate risks in advance: Smoke and heat detectors monitor environmental conditions in real time to identify fire hazards at an early stage and drastically slow fire spread.
  • Accurate linkage for efficient emergency response: Automatically triggers sound-light alarms, fire broadcast, sprinkler systems, smoke exhaust fans and other equipment to activate emergency procedures instantly.
  • Full monitoring for reliable safety: Centralized management via fire control room main units with real-time equipment status monitoring; supports dual manual/automatic control modes to ensure no blind spots in emergency handling.
  • Compliant design for smooth acceptance: All product lines hold 3C certification and meet the requirements of Code for Design of Automatic Fire Alarm System (GB50116), facilitating smooth fire acceptance of projects.

3. Product Highlights

✅ Full-range 3C certification for compliant and guaranteed quality

✅ Wired/wireless multi-signal transmission to fit various building scenarios

✅ Modular design with expandable detection points, suitable for small projects to large complexes

✅ High-sensitivity detection hardware with low false alarm rate and fast warning response

✅ Compatible with smart fire protection platforms for remote monitoring and operation & maintenance

✅ Customized solution design and OEM processing services to meet diverse project demands

II. Product Classification

image

System Internal Structure Drawing

  1. Fire detection devices: Point photoelectric smoke fire detectors, point heat fire detectors, combustible gas detectors, flame detectors, etc.
  2. Alarm trigger devices: Manual fire alarm call points, fire hydrant call points, emergency start/stop buttons, etc.
  3. Alarm control devices: Linkage-type fire alarm controllers, gas fire suppression controllers, fire control room graphic display units, indicator panels, etc.
  4. Alarm display & transmission devices: Fire sound-light alarms, fire telephones, fire broadcast, input/output modules, isolators, water flow indicators, etc.
  5. Supporting system devices: Gas fire suppression systems, electrical fire monitoring systems, fire equipment power supply monitoring systems, emergency lighting and evacuation indicator systems, etc.

III. System Composition

A complete automatic fire alarm system consists of five core components:

image

Workshop Production Line

1. Material Advantages

  • Detector housings adopt flame-retardant ABS engineering plastic, high temperature resistant and corrosion resistant, meeting fire equipment flame retardant standards.
  • Internal core components use industrial-grade photoelectric sensors and microprocessors with strong anti-interference performance and long service life.
  • Cables are flame-retardant copper wires with superior insulation, adapting to complex building wiring environments and stable signal transmission.
  • Main unit housings are made of cold-rolled steel plates with electrostatic spraying, anti-corrosion and anti-oxidation, suitable for harsh environments such as computer rooms and power distribution rooms.

2. Process Advantages

  • Fully automatic SMT patch technology delivers high-precision component soldering and low equipment failure rate.
  • Detectors feature dust and insect-proof labyrinth structure to reduce environmental interference and false alarms.
  • Modular assembly for main units enables quick maintenance and flexible expansion of detection points, lowering later operation costs.
  • All finished products undergo 72-hour aging tests, high-low temperature tests and EMC tests before delivery to guarantee stable performance.

3. Customization Advantages

image

On-site Installation of AL Fire Alarm System

  • Fire alarm controllers with customized loop capacities according to project detection point quantities.
  • Customized special-scenario equipment: Explosion-proof detectors, industrial high-temperature resistant detectors, wireless networking systems, etc.
  • Personalized functions: Custom linkage logic, display interface language, communication protocol docking with third-party platforms.
  • One-stop OEM services including brand, appearance and software customization.

4. Cost Advantages

  • Self-owned factory mass production eliminates intermediate links for higher cost performance.
  • Modular configuration allows point-by-point matching to avoid unnecessary cost waste.
  • Stable equipment performance cuts long-term operation and maintenance expenses.
  • Free pre-sales solution design optimizes system configuration and reduces overall procurement costs.

5. Quality Advantages

  • Full product range certified by national fire product quality supervision and inspection center with valid 3C certificates.
  • Production strictly follows ISO9001 quality management system with full-process quality inspection from raw materials to finished goods.
  • 100% functional testing for all equipment before delivery to meet factory standards.
  • Supports third-party testing with traceable quality, providing solid evidence for project acceptance.

V. Detailed Product Categories

表格

Product CategoryCore ProductsApplicable ScenariosCore Functions
Smoke DetectorsPoint photoelectric smoke fire detectorsComputer rooms, offices, warehouses, shopping malls and other indoor spacesMonitor smoke concentration for early fire warning
Heat DetectorsPoint heat fire detectorsKitchens, power distribution rooms, parking garages and other smoke-prone areasMonitor ambient temperature changes to warn high-temperature fires
Manual Call PointsManual fire alarm call pointsPublic areas on all floors of buildingsManually trigger fire alarm signals for emergency alerts
Sound-Light AlarmsFire sound-light alarmsCorridors and public zones on all building floorsEmit sound and light signals to guide personnel evacuation
Fire Alarm ControllersLinkage-type fire alarm controllersFire control roomsReceive and process alarm signals, control linked fire equipment
Gas Suppression ControllersGas fire suppression main unitsComputer rooms, power distribution rooms, data centers and other gas fire suppression areasControl startup and shutdown of gas fire suppression systems
Input/Output ModulesFire signal modulesAll fire equipment loopsCollect field signals and realize linkage control
Fire Telephone SystemsFixed fire telephonesAll building floors and fire control roomsEmergency fire communication to connect site staff and control room

VI. Material & Process Analysis

1. Material Specifications

image

Product Selling Points Infographic

  • Detector housing: V-0 grade flame-retardant ABS plastic, high temperature and aging resistant, anti-deformation, service life over 10 years.
  • Core sensors: Imported photoelectric/thermal sensors with fast response, strong anti-interference, false alarm rate below industry standard, accurate real fire signal identification.
  • Main unit housing: 1.2mm cold-rolled steel plate with phosphating and electrostatic spraying, anti-corrosion and anti-oxidation, suitable for humid and dusty harsh environments.
  • Communication cables: Flame-retardant copper core wires with low conductor resistance and eco-friendly flame-retardant insulation, stable signal transmission even under fire conditions.

2. Core Production Processes

  • SMT Patch Process: Fully automatic chip mounters eliminate virtual and missing soldering from manual operation, boosting equipment consistency and stability.
  • Aging Test Process: 72-hour continuous power-on aging for every unit to simulate real operating conditions and screen out early failures.
  • Dust & Insect Proof Process: Labyrinth detection chamber design blocks dust and insects, minimizing environment-triggered false alarms and extending service life.
  • EMC Shielding Process: Electromagnetic shielding, surge protection and filter circuits for main units to avoid malfunctions caused by industrial electromagnetic interference, ideal for complex industrial sites.

3. Safety Certifications

  • Mandatory China Compulsory Certification (3C/CCC)
  • Fire Product Type Approval Certificate
  • ISO9001 Quality Management System Certification
  • Third-party fire product quality inspection reports
image

Product Comparison Chart

VII. In-Stock Products

Guangzhou Laian Intelligent maintains sufficient inventory for all automatic fire alarm system products, including:

  • Point smoke/heat detectors (general, explosion-proof, high-temperature resistant types)
  • Manual call points, hydrant call points, sound-light alarms
  • 16/32/64/128-loop linkage-type fire alarm controllers
  • Gas fire suppression controllers, input/output modules, isolators, water flow indicators
  • Fire telephone systems, indicator panels, fire broadcast and other supporting equipment

Same-day shipment upon payment with national logistics delivery to meet urgent project procurement demands. Real-time stock information available via customer service inquiry.

VIII. OEM Processing & Confidentiality

Guangzhou Laian Intelligent provides OEM/ODM processing services for automatic fire alarm systems with the following supports:

  • Brand customization: Custom customer LOGO, packaging and user manuals
  • Product customization: Custom equipment appearance, functions and communication protocols
  • Solution customization: Exclusive system design for specific building projects
  • Confidentiality service: Strict non-disclosure agreements to protect client project and brand information with zero data leakage
  • Mass production: Standardized self-owned workshop for stable delivery cycles and controllable quality for bulk orders

IX. Product SKU Specifications

表格

Product NameModel SpecificationPower SupplyCommunication ModeInstallation MethodOperating Ambient Temperature
Point Smoke DetectorJTY-GM-LA01DC24VTwo-wire BusCeiling Mount-10℃ ~ +55℃
Point Heat DetectorJTWB-ZCD-LA02DC24VTwo-wire BusCeiling Mount-10℃ ~ +55℃
Manual Fire Alarm Call PointJ-SAM-LA03DC24VTwo-wire BusWall Mount-10℃ ~ +55℃
Fire Sound-Light AlarmHX-100BDC24VTwo-wire BusWall Mount-10℃ ~ +55℃
Linkage Fire Alarm ControllerJB-QB-LA2000AC220VTwo-wire Bus / RS485Cabinet / Wall Mount0℃ ~ +40℃
Gas Fire Suppression ControllerJB-QB-LA3000AC220VTwo-wire Bus / CAN BusWall Mount0℃ ~ +40℃
Input/Output ModuleLD-8300DC24VTwo-wire BusWall Mount-10℃ ~ +55℃

X. Technical Parameter Table

表格

Technical ParameterLinkage Fire Alarm ControllerSmoke DetectorHeat DetectorManual Call PointSound-Light Alarm
Operating VoltageAC220V±15%DC24VDC24VDC24VDC24V
Backup PowerDC24V Lead-acid Battery––––
Loop Capacity16/32/64/128 loops, max 200 points per loop––––
Communication ModeTwo-wire Bus / RS485 / CAN BusTwo-wire BusTwo-wire BusTwo-wire BusTwo-wire Bus
Alarm Response Time≤3s≤10s≤10s≤1s≤2s
Operating CurrentStandby ≤100mA, Alarm ≤300mAStandby ≤100μA, Alarm ≤3mAStandby ≤100μA, Alarm ≤3mAStandby ≤100μA, Alarm ≤3mAOperating ≤50mA
Installation MethodCabinet / Wall MountCeiling MountCeiling MountWall MountWall Mount
Ingress ProtectionIP30IP30IP30IP30IP30
Ambient Temperature0℃ ~ +40℃-10℃ ~ +55℃-10℃ ~ +55℃-10℃ ~ +55℃-10℃ ~ +55℃
Relative Humidity≤95% RH (No Condensation)≤95% RH (No Condensation)≤95% RH (No Condensation)≤95% RH (No Condensation)≤95% RH (No Condensation)

XI. Applicable Scenarios

  • Commercial buildings: Shopping malls, office towers, hotels, supermarkets, exhibition centers, ensuring fire safety for crowded public spaces
  • Industrial sites: Factory workshops, warehouses, power distribution rooms, computer rooms, data centers, photovoltaic & energy storage power stations, adapting to complex industrial environments
  • Civil buildings: Residential communities, apartments, villas, schools, hospitals, meeting daily fire early warning demands
  • Special venues: Tunnels, pipe corridors, underground parking garages, cold storage, kitchens, gas stations, with customized targeted solutions
  • Public facilities: Railway stations, airports, metro stations, libraries, museums, matching large public building fire protection requirements
image

System Schematic Diagram

XII. Customization Service Details

1. Customization Scope

  • Detection point customization: Controllers with customized loop capacities for projects of different scales
  • Scenario customization: Specialized equipment for explosion-proof, high-temperature, humid and dusty environments
  • Function customization: Custom linkage logic, display interfaces, platform communication docking, smart fire protection platform integration
  • Appearance customization: Client LOGO, housing color and packaging customization
  • Solution customization: Exclusive system, wiring and linkage logic design for individual projects

2. Customization Process

  1. Demand Communication: Client submits project venue, detection point quantity and special functional requirements
  2. Solution Design: Technical team drafts exclusive system plan and equipment list
  3. Plan Confirmation: Client verifies all details and signs customization contract
  4. Production & Processing: Self-owned factory manufactures products per design with strict quality and delivery control
  5. Factory Inspection: Full functional testing and aging test for customized equipment
  6. Delivery & Acceptance: Product delivery with installation & commissioning guidance and full technical support

3. Customization Advantages

image

Application Scenarios Rendering

  • Self-owned factory with flexible production scheduling to meet personalized client requirements
  • Professional technical team with over 10 years of fire system design experience for highly compatible solutions
  • Strict non-disclosure agreements to protect client brand and project data
  • One-stop full-process customization service from design to post-delivery acceptance without multi-party coordination
  • Sample customization available; mass production only after client sample confirmation to lower customization risks

XIII. Successful Cases

1. Partner Clients

  • Large commercial complexes: Guangzhou Wanda Plaza, Shenzhen MixC
  • Industrial projects: Foshan photovoltaic power station, Dongguan data center computer room
  • Civil buildings: Guangzhou residential community, Shenzhen office tower
  • Public facilities: Guangzhou Metro Station, school teaching buildings
  • Special venues: Underground pipe corridor project, chemical enterprise explosion-proof project

2. Case Highlights

  • Photovoltaic power station: Custom high-temperature resistant anti-interference fire alarm system, stable operation for over 3 years in harsh outdoor environments
  • Data center: Integrated gas fire suppression linkage system for fast accurate fire detection and extinguishing to protect core IT equipment
  • Residential community: Hybrid wired-wireless networking for old community renovation, convenient wiring and 100% fire acceptance pass rate
  • Commercial complex: Multi-loop partitioned linkage system for zone management, automatic control of sprinklers, smoke exhaust and broadcast for efficient emergency response

XIV. Procurement Service Guarantees

1. Supply Guarantee

Standardized self-owned production workshop with annual output exceeding 100,000 sets. Full-range ready stock supports large batch orders with stable delivery cycles for urgent project demands.

2. Quality Guarantee

All products hold 3C certification, manufactured under ISO9001 quality management system. 100% functional and aging testing for all finished goods before shipment. Third-party inspection supported with traceable quality records and 1-year product warranty.

3. Logistics Guarantee

Long-term cooperation with major national logistics providers offering land transport and express delivery. Delivery within 3–5 days for most domestic regions, 7–10 days for remote areas; designated logistics options available per client request.

4. After-Sales Guarantee

  • Free technical consultation, solution design and installation & commissioning guidance
  • Service outlets across multiple regions with on-site installation, commissioning and maintenance support
  • 24-hour technical response and 48-hour troubleshooting solutions for equipment faults
  • Free repair or replacement for non-artificial damage within warranty period, lifelong technical support available

5. Invoice Guarantee

13% VAT special invoices available, pre-invoicing before payment acceptable per contract terms. Authentic invoices eligible for corporate tax deduction and financial reimbursement.

XV. Conversion Module

  1. Action Buttons: Consult Now | Get Quotation | Request Sample | View Solution
  2. Contact Information
    • Phone: +86 13509238849, +86 13509238849
    • Official Website: gdlain.com
    • WeChat: Same numbers as mobile phones for consultation
  3. Factory Address:
Shopping Cart