KITOZER
KITOZER

Base Station Lightning Protection Power Distribution Module Solution

Table of Contents

1. System Introduction

The base station lightning protection power distribution module is an integrated protection and power distribution unit designed for outdoor deployment of 4G/5G mobile communication base stations, severe lightning interference, frequent power grid fluctuations and other scenarios. It integrates core functions including multi-stage lightning protection, overcurrent/overvoltage protection, power distribution, intelligent monitoring and remote operation & maintenance. It serves as the core safety barrier of the base station power supply system.

The system strictly complies with standards such as Code for Design of Lightning Protection and Earthing Engineering of Communication Bureau (Station) (YD/T 5098) and Code for Design of Protection of Structures against Lightning (GB 50057). It builds a three-level lightning protection system of “Class I current discharge — Class II voltage limiting — Class III precise protection”. Meanwhile, it integrates AC/DC power distribution, fault alarms and remote management capabilities. It can effectively resist direct lightning strikes, induced lightning, ground potential counterattack and power grid surge impacts, ensuring stable 7×24-hour operation of core loads including BBU, RRU, transmission equipment and storage batteries of base stations. It reduces risks of equipment damage and communication outages caused by lightning strikes, and adapts to various complex outdoor environments such as mountainous areas, plateaus, coastal regions and deserts.

image

Overall Rendering of Base Station Lightning Protection Power Distribution Module

2. System Composition

The KITOZER base station lightning protection power distribution module system consists of four core parts: core functional units, auxiliary protection units, monitoring & management units, and earthing & wiring units. All units adopt modular design and coordinate with each other to form a complete protection system.

2.1 Core Functional Units

  • Class I Lightning Protection Unit (Class B) Deployed at the mains power inlet, it takes Gas Discharge Tube (GDT) as the core component, withstands high-current lightning surges of 10/350μs with a discharge capacity ≥60kA to release energy from direct lightning strikes and strong induced lightning.
  • Class II Lightning Protection Unit (Class C) Installed at the front end of AC power distribution cabinets / switching power supplies, it adopts Metal Oxide Varistor (MOV) arrays with a nominal discharge capacity of 20–40kA under the 8/20μs waveform to limit residual surge voltage.
  • Class III Lightning Protection Unit (Class D) Embedded in rectifier modules, DC output sides or front ends of equipment, it adopts TVS tubes plus filter circuits with a response time ≤25ns, precisely clamping residual voltage within the safe range of equipment (≤1.0kV).
  • AC Power Distribution Unit Integrates automatic switching for dual mains/generator power, air switches and fuses with surge protection. It supports 220V/380VAC input and distributes power to rectifier modules and AC loads.
  • DC Power Distribution Unit (DCDU) Provides -48VDC output with integrated lightning protection and overcurrent protection, featuring 6–24 distribution channels for DC loads such as BBU and RRU, and supporting hot-swap maintenance.
image

Material Close-up of Base Station Lightning Protection Power Distribution Module

2.2 Auxiliary Protection Units

  • Backup Protection Unit (SCB / Fuse) Connected in series at the front end of SPDs to prevent fire hazards caused by short circuits of aging SPDs, featuring rapid cut-off for overcurrent and short-circuit faults.
  • Equipotential Bonding Unit Contains equipotential copper bars and earthing busbars to reliably connect equipment enclosures, lightning arresters, cabinets and earthing grids, eliminating potential differences and restraining ground potential counterattack.
  • Lightning Protection Cabinet Outdoor type with IP65 protection grade and indoor type with IP30 protection grade, made of cold-rolled steel plate / aluminum alloy with UL94 V0 flame retardant grade, offering dustproof, waterproof and anti-corrosion performance.

2.3 Monitoring & Management Units

  • Status Monitoring Module Collects real-time parameters including degradation status of lightning protection modules, leakage current, residual voltage, temperature, and current/voltage of power distribution loops.
  • Alarm Unit Supports local sound-light alarms and dry contact alarms, with remote RS485/SNMP communication to connect to base station environment monitoring systems for real-time fault reporting.
  • Remote Operation & Maintenance Module Enables remote parameter configuration, lightning protection status query, fault reset and lightning strike count statistics, adapting to operation & maintenance requirements of unattended base stations.

2.4 Earthing & Wiring Units

  • Combined Earthing Grid The base station iron tower, machine room earthing grid and lightning arrester earthing grid share the same earthing body. The earthing resistance ≤4Ω (≤1Ω in severe lightning zones). Wiring follows the “short, straight and thick” principle: earthing wire length ≤0.5m and cross-sectional area ≥35mm² copper cable.
  • Shielded Wiring Power cables and signal cables are laid separately with shielded cables whose shielding layers are earthed at both ends to reduce coupling interference from lightning electromagnetic pulses.

3. System Classification

image

Workshop Production Site of Laian Intelligent

KITOZER base station lightning protection power distribution modules are classified from four dimensions: protection grade, power supply standard, installation scenario and functional configuration, covering full demands from basic to high-end levels.

3.1 Classification by Protection Grade (Three-level Protection System)

  • Basic Type (Class II + C) Applicable to ordinary lightning zones (annual thunderstorm days <40 days), equipped with Class C lightning protection and basic power distribution with a discharge capacity of 20kA to meet conventional protection demands of base stations.
  • Standard Type (Class I + II + D) Applicable to medium lightning zones (annual thunderstorm days 40–60 days), featuring B+C+D three-level lightning protection with a discharge capacity of 60kA and integrated basic monitoring, widely used in urban and suburban base stations.
  • Enhanced Type (Class I + II + D + Intelligent Monitoring) Applicable to severe lightning zones (annual thunderstorm days >60 days), mountainous and coastal base stations. It adopts B+C+D three-level lightning protection (discharge capacity up to 120kA), integrated intelligent monitoring, remote operation & maintenance and lightning strike counting, and supports dual-system hot standby.

3.2 Classification by Power Supply Standard

  • AC Type (AC220V/380V) Adapted to mains-powered base stations, integrating AC lightning protection, dual-power switching and AC power distribution to protect rectifiers, air conditioners, lighting and other AC loads.
  • DC Type (DC-48V/24V) Adapted to DC-powered base stations and remote RRU sites, integrating DC lightning protection and DCDU power distribution to protect DC loads such as BBU, RRU and transmission equipment.
  • AC-DC Integrated Type Supports both AC input and DC output, integrating AC/DC lightning protection, dual-power switching and AC/DC power distribution, suitable for mixed-power supply base stations.

3.3 Classification by Installation Scenario

  • Indoor Type Installed inside base station machine rooms and integrated cabinets with IP30 protection grade, adopting standard 19-inch rack mounting for indoor power distribution scenarios.
  • Outdoor Type Mounted on base station iron towers, outdoor cabinets and poles with IP65 protection grade, operating at -40℃~+85℃ with dustproof and anti-corrosion performance to adapt to harsh outdoor environments.
  • Embedded Type Built into switching power supplies and integrated cabinets with modular design to save space, suitable for integrated base station scenarios.

3.4 Classification by Functional Configuration

image

Structure Schematic of Base Station Lightning Protection Power Distribution Module

  • Economical Type Equipped with basic lightning protection and simple power distribution without monitoring functions, cost-effective for low-cost station construction.
  • Intelligent Type Integrates lightning protection, power distribution, status monitoring and remote alarms with RS485 communication, suitable for conventionally operated base stations.
  • Flagship Type Combines lightning protection, power distribution, intelligent monitoring, remote operation & maintenance, lightning strike counting, dual-system hot standby and fault self-recovery, designed for unattended and high-reliability base stations.

4. System Principle Diagrams

4.1 AC Lightning Protection Power Distribution System Schematic (Standard Type)

4.2 DC Lightning Protection Power Distribution System Schematic (DC Type)

DC-48V Input → Air Switch → Class D Lightning Protection Module → DC Busbar → Multi-channel Output (BBU/RRU/Transmission Equipment)

↓

Earthing Busbar → Combined Earthing Grid

4.3 Three-level Lightning Protection Logic Diagram

Mains Inlet → Class I Lightning Protection (Class B, 10/350μs, 60kA) → Class II Lightning Protection (Class C, 8/20μs, 40kA) → Class III Lightning Protection (Class D, ≤25ns) → Load

↓

Backup Protection (SCB) → Earthing Grid

5. Full System Configuration List (Low / Medium / High Tiers)

image

Outdoor Tower-mounted Lightning Protection Distribution Cabinet On-site

5.1 Low-tier Configuration List (Economical, Indoor Base Stations in Ordinary Lightning Zones)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Class C AC SPD ModuleKITOZER-SPD-C20Rated Voltage: 220VAC; Nominal Discharge Capacity: 20kA (8/20μs); Response Time: ≤25ns; Residual Voltage: ≤1.2kV; Failure Indicator: Red Alarm; Mounting: 35mm DIN Rail1SetKITOZERClass II lightning protection for AC power distribution
2Economical AC Distribution BoxKITOZER-AC-D10Input: 220VAC/50Hz; Output: 4 circuits ×10A; Protection: Air Switch + Fuse; Protection Grade: IP30; Material: Cold-rolled Steel; Dimension: 400×300×150mm1SetKITOZERIndoor AC distribution with dual-input interface
3Equipotential Copper BarKITOZER-EB-400Material: Nickel-plated Pure Copper; Dimension: 400×50×5mm; Earthing Holes: 8pcs; Withstand Current: 100A1PieceKITOZERMachine room equipotential bonding for SPD earthing
4Lightning Protection Earthing CableKITOZER-GW-35Material: Multi-strand Copper Core; Cross-section: 35mm²; Length: 1m; Insulation: Flame-retardant PVC2StripKITOZERConnect SPD to earthing busbar
5Air SwitchKITOZER-MCB-10PRated Current: 10A; Poles: 1P; Tripping Characteristic: Class C; Breaking Capacity: 6kA4PieceKITOZEROvercurrent protection for distribution loops

5.2 Mid-tier Configuration List (Standard, Indoor/Outdoor Base Stations in Medium Lightning Zones)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Class B AC Lightning Protection BoxKITOZER-SPD-B60Rated Voltage: 380/220VAC; Impulse Discharge Capacity: 60kA (10/350μs); Nominal Discharge Capacity: 40kA (8/20μs); Residual Voltage: ≤1.5kV; Protection Grade: IP65; Failure Indicator: Red; With Remote Signal Interface1SetKITOZERClass I lightning protection for mains inlet
2Class C AC SPD ModuleKITOZER-SPD-C40Rated Voltage: 220VAC; Nominal Discharge Capacity: 40kA (8/20μs); Response Time: ≤25ns; Residual Voltage: ≤1.0kV; Failure Indicator: Red; DIN Rail Mounting1SetKITOZERClass II lightning protection for front end of switching power supply
3Class D DC SPD ModuleKITOZER-SPD-D10Rated Voltage: -48VDC; Nominal Discharge Capacity: 10kA (8/20μs); Response Time: ≤20ns; Residual Voltage: ≤0.8kV; Hot-swap Design; Failure Alarm2SetKITOZERClass III lightning protection for front end of BBU/RRU
4AC-DC Integrated Distribution BoxKITOZER-ACDC-D20Input: 220VAC/-48VDC; AC Output: 6 circuits ×16A; DC Output: 8 circuits ×10A; Protection: Air Switch + SPD + Overcurrent; Protection Grade: IP54; Material: Aluminum Alloy; Dimension: 500×400×200mm1SetKITOZERIntegrated AC/DC distribution for outdoor adaptation
5Intelligent Monitoring ModuleKITOZER-MON-S10Monitored Parameters: SPD Status, Voltage, Current, Temperature; Communication: RS485; Alarm: Local Sound-light + Dry Contact; Power Supply: 220VAC/-48VDC; Dimension: 19-inch 1U1SetKITOZERReal-time monitoring, connect to environment monitoring system
6Surge Backup Protector (SCB)KITOZER-SCB-60Rated Current: 60A; Breaking Capacity: 25kA; Protection: SPD Short-circuit / Overload; Response Time: ≤100ns; Flame-retardant Enclosure1PieceKITOZERBackup protection for SPD to prevent fire risks
7Equipotential Bonding KitKITOZER-EB-KITContains 1pc 400×50×5mm copper bar, 10 earthing terminals, 5pcs 35mm² earthing cables, 1pc bolt kit1KitKITOZERComplete equipotential bonding for machine rooms
8Outdoor Lightning Protection CabinetKITOZER-BOX-IP65Material: Sprayed Cold-rolled Steel; Protection Grade: IP65; Dimension: 600×500×250mm; Waterproof Rubber Strip, Anti-theft Lock1SetKITOZERProtective enclosure for outdoor lightning protection & distribution units

5.3 High-tier Configuration List (Enhanced, Outdoor Base Stations in Severe Lightning / Mountain / Coastal Zones)

表格

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1High-energy Class B Lightning Protection BoxKITOZER-SPD-B120Rated Voltage: 380/220VAC; Impulse Discharge Capacity: 120kA (10/350μs); Nominal Discharge Capacity: 80kA (8/20μs); Residual Voltage: ≤1.2kV; Protection Grade: IP65; Dual-module Hot Standby, Lightning Strike Counter; Remote Signal + RS485 Communication1SetKITOZEREnhanced Class I lightning protection for severe lightning zones
2Intelligent Class C SPD ModuleKITOZER-SPD-C60Rated Voltage: 220VAC; Nominal Discharge Capacity: 60kA (8/20μs); Response Time: ≤20ns; Residual Voltage: ≤0.8kV; Leakage Current & Temperature Monitoring, Remote Reset; DIN Rail Mounting2SetKITOZERRedundant Class II lightning protection for improved reliability
3Precision Class D SPD ModuleKITOZER-SPD-D20Rated Voltage: -48VDC; Nominal Discharge Capacity: 20kA (8/20μs); Response Time: ≤15ns; Residual Voltage: ≤0.6kV; Dual-structure TVS+GDT, Hot-swap, Fault Self-recovery4SetKITOZERClass III precise lightning protection for precision equipment
4DC Power Distribution Unit (DCDU)KITOZER-DCDU-24Input: -48VDC/200A; Output: 24 circuits ×10A; Integrated SPD, Overcurrent & Short-circuit Protection, Hot-swap Modules, Current Monitoring, Remote Control; 19-inch Rack Mount1SetKITOZERCentralized DC load distribution for RRU dedicated use
5Intelligent AC-DC Distribution CabinetKITOZER-ACDC-D30Input: Dual 220VAC (Auto-switching)/-48VDC; AC Output: 8 circuits ×20A; DC Output: 16 circuits ×15A; Integrated SPD, Monitoring, Alarm & Remote O&M; Protection Grade: IP65; Material: 304 Stainless Steel; Dimension: 700×600×300mm1SetKITOZERFlagship power distribution for unattended base stations
6Remote O&M Management ModuleKITOZER-MON-S20Monitored Parameters: SPD Status, Voltage, Current, Temperature, Lightning Strike Count, Leakage Current; Communication: RS485/SNMP/Ethernet; Alarm: Local Sound-light + SMS/APP Push; Remote Configuration/Reset/Upgrade, Dual Power Redundancy1SetKITOZERFull-function monitoring & O&M for unattended sites
7Backup Protection ArrayKITOZER-SCB-100Rated Current: 100A; Breaking Capacity: 50kA; Dual-channel Redundant Protection for SPD Short-circuit/Overload/Overheat, Remote Alarm; Flame-retardant Enclosure2PieceKITOZERMultiple backup protection for lightning protection system
8Combined Earthing Grid KitKITOZER-GND-KITContains 10m 50×5mm flat steel, 5 earthing electrodes, 5kg resistance reducing agent, 10 earthing cables, 1pc earthing test terminal; Earthing Resistance ≤1Ω1KitKITOZERDedicated earthing system for severe lightning zones
9Outdoor Integrated Protective CabinetKITOZER-BOX-IP67Material: 304 Stainless Steel; Protection Grade: IP67; Dimension: 800×700×350mm; Operating Temp: -40℃~+85℃, Anti-corrosion, Waterproof Vent Valve, Air Cooling1SetKITOZERExtreme environment protection for coastal & desert sites
10Lightning Strike CounterKITOZER-LC-01Counting Range: 0–9999 times; Response Time: ≤1μs; Power Supply: 220VAC/-48VDC; Local LED Display + Remote Upload; Record Lightning Time & Intensity1SetKITOZERLightning data statistics for O&M analysis

6. Full Product Technical Parameters

image

Base Station Command Center Platform Monitoring Screen

6.1 Class B Lightning Protection Box (KITOZER-SPD-B60/B120)

  • Rated Operating Voltage: 380/220VAC (50/60Hz)
  • Impulse Discharge Capacity (Iimp): 60kA/120kA (10/350μs)
  • Nominal Discharge Current (In): 40kA/80kA (8/20μs)
  • Voltage Protection Level (Up): ≤1.5kV/≤1.2kV (8/20μs)
  • Response Time: ≤25ns
  • Failure Indicator: Red LED for alarm, Green for normal status
  • Communication Interface: RS485, Dry Contact (Remote Signal)
  • Protection Grade: IP65
  • Operating Temperature: -40℃~+85℃
  • Flame Retardant Grade: UL94 V0
  • Enclosure Material: Sprayed Cold-rolled Steel / 304 Stainless Steel

6.2 Class C SPD Module (KITOZER-SPD-C20/C40/C60)

  • Rated Operating Voltage: 220VAC (50/60Hz)
  • Nominal Discharge Current (In): 20kA/40kA/60kA (8/20μs)
  • Voltage Protection Level (Up): ≤1.2kV/≤1.0kV/≤0.8kV
  • Response Time: ≤25ns/≤20ns
  • Leakage Current: ≤30μA (Normal), ≥50μA (Alarm Trigger)
  • Failure Indicator: Red Window Alarm, Green Normal
  • Mounting: Standard 35mm DIN Rail
  • Operating Temperature: -40℃~+85℃
  • Flame Retardant Grade: UL94 V0
  • Dimension: 80×65×25mm

6.3 Class D SPD Module (KITOZER-SPD-D10/D20)

  • Rated Operating Voltage: -48VDC (24VDC Optional)
  • Nominal Discharge Current (In): 10kA/20kA (8/20μs)
  • Voltage Protection Level (Up): ≤0.8kV/≤0.6kV
  • Response Time: ≤20ns/≤15ns
  • Protection Mode: Full Line-Ground & Line-Line Protection
  • Hot-swap Support: Hot replacement without power cut-off
  • Failure Alarm: Dry Contact + LED Indicator
  • Mounting: 35mm DIN Rail / Embedded
  • Operating Temperature: -40℃~+85℃
  • Dimension: 70×55×20mm
image

On-site Maintenance of Lightning Protection Distribution Cabinet

6.4 AC-DC Distribution Box (KITOZER-AC-D10/ACDC-D20/ACDC-D30)

  • AC Input: 220VAC±20%, 50Hz; Auto Dual-power Switching (High-tier Model)
  • DC Input: -48VDC±10%
  • AC Output: 4 circuits ×10A / 6 circuits ×16A / 8 circuits ×20A
  • DC Output: 8 circuits ×10A / 16 circuits ×15A
  • Protection Functions: SPD, Overcurrent, Short-circuit, Overvoltage, Undervoltage Protection
  • Protection Grade: IP30 (Indoor) / IP54 / IP65 (Outdoor)
  • Material: Cold-rolled Steel / Aluminum Alloy / 304 Stainless Steel (High-tier)
  • Operating Temperature: -30℃~+70℃ (Indoor) / -40℃~+85℃ (Outdoor)
  • Dimension: 400×300×150mm / 500×400×200mm / 700×600×300mm

6.5 DC Power Distribution Unit (DCDU, KITOZER-DCDU-24)

  • Input Voltage: -48VDC (-40VDC~-56VDC)
  • Max Input Current: 200A
  • Output Circuits: 24 circuits
  • Single-circuit Output Current: Max 10A
  • Protection Functions: SPD, Overcurrent, Short-circuit, Reverse Polarity, Overvoltage Protection
  • Monitoring Functions: Real-time Current & Voltage per circuit, SPD Status Monitoring
  • Communication Interface: RS485, Dry Contact
  • Mounting: Standard 19-inch Rack (1U)
  • Operating Temperature: -40℃~+85℃
  • Dimension: 482×220×44mm
image

Installation of Mountain Outdoor Base Station Equipment

6.6 Intelligent Monitoring / Remote O&M Module (KITOZER-MON-S10/S20)

  • Monitored Parameters: SPD Status, Leakage Current, Residual Voltage, Ambient Temperature, Loop Voltage/Current, Lightning Strike Count (High-tier)
  • Communication Interface: Standard RS485; High-tier with SNMP, Ethernet & Dry Contact
  • Alarm Mode: Local Sound-light Alarm + Remote Environment Monitoring System Reporting
  • Power Supply: 220VAC/-48VDC (Dual Power Redundancy for High-tier)
  • Remote Functions: Parameter Configuration, Fault Reset, Data Query
  • Mounting: 19-inch Rack (1U) / Embedded
  • Operating Temperature: -30℃~+70℃
  • Dimension: 482×220×44mm

6.7 Surge Backup Protector (SCB, KITOZER-SCB-60/100)

  • Rated Operating Current: 60A/100A
  • Breaking Capacity: 25kA/50kA
  • Protection Characteristics: SPD Short-circuit, Overload & Overheat Protection
  • Response Time: ≤100ns
  • Tripping Characteristic: Class C
  • Flame Retardant Grade: UL94 V0
  • Operating Temperature: -40℃~+85℃
  • Dimension: 90×70×30mm

6.8 Lightning Strike Counter (KITOZER-LC-01)

  • Counting Range: 0~9999 times
  • Response Time: ≤1μs
  • Power Supply: 220VAC/-48VDC
  • Display: Local LED Digital Tube Display
  • Communication Interface: RS485 (Remote Data Upload)
  • Recording Function: Lightning Strike Count, Occurrence Time & Intensity
  • Operating Temperature: -40℃~+85℃
  • Dimension: 70×60×25mm

7. Full Product Application Scope

7.1 Base Station Scenarios

  • 4G/5G Macro Base Stations: Urban, suburban, rural, mountainous and hilly outdoor macro base stations, suitable for tower, pole and rooftop installation.
  • 5G Distributed Base Stations: BBU machine rooms, remote RRU sites, pico base stations and micro base stations, covering indoor & outdoor miniaturized base station scenarios.
  • Edge Computing Base Stations: 5G base stations integrated with edge computing units, protecting edge servers, gateways and other precision equipment.

7.2 Communication Supporting Scenarios

  • Base Station Machine Rooms: Indoor integrated cabinets, power cabinets and transmission cabinets, protecting rectifiers, storage batteries, transmission equipment and switches.
  • Outdoor Cabinets: Integrated outdoor communication cabinets, power cabinets and monitoring cabinets for unattended outdoor sites.
  • Microwave / Satellite Communication Stations: Microwave towers and satellite ground stations, protecting microwave transceivers, satellite receivers and antenna systems.

7.3 Industry-specific Scenarios

  • Power Industry: Power communication base stations, substation communication machine rooms, transmission line monitoring base stations.
  • Transportation Industry: High-speed rail / metro communication base stations, highway monitoring base stations, airport communication machine rooms.
  • Energy Industry: PV / wind power base stations, oil & mine communication base stations, energy storage power station communication systems.
  • Security Industry: Smart city monitoring base stations, border & coastal monitoring sites, emergency communication base stations.

7.4 Environmental Adaptation Scope

  • Climatic Conditions: High temperature (+85℃), low temperature (-40℃), high humidity (RH 95% non-condensing), heavy sandstorm, salt spray (coastal), severe thunderstorms (annual thunderstorm days >60 days).
  • Geographical Conditions: Plains, mountainous areas, plateaus, deserts, coastal areas, islands and other complex geographical environments.

8. Full Product Advantages

8.1 Core Functional Advantages

  1. Three-level lightning protection with full-link coverage The B+C+D three-level lightning protection system covers the full link from mains inlet, power distribution to equipment front end, with maximum discharge capacity up to 120kA, residual voltage as low as 0.6kV and response time ≤15ns, effectively resisting direct lightning, induced lightning and ground potential counterattack.
  2. Integrated AC & DC protection Supports both AC 220V/380V and DC -48V/24V power supply systems, integrating lightning protection, power distribution, protection and monitoring functions to adapt to mixed-power base station scenarios and simplify system architecture.
  3. Intelligent monitoring & remote O&M Real-time monitoring of SPD status, leakage current, residual voltage, temperature, voltage and current, supporting RS485/SNMP/Ethernet communication to connect with environment monitoring systems for remote fault alarms, reset and maintenance, fitting unattended base stations.
  4. Multi-layer protection for high safety Integrated overcurrent, short-circuit, overvoltage, undervoltage, overheat and reverse polarity protection, matched with SCB backup protectors to prevent fire hazards caused by aging short-circuited SPDs. High-tier models adopt dual-module hot standby and fault self-recovery to guarantee continuous power supply.

8.2 Customization & Production Advantages

  1. In-depth customization service Customizable protection grade, discharge capacity, output channels, communication protocols and appearance dimensions according to customer demands, adapting to special base station scenarios such as miniaturization, high protection and explosion-proof requirements.
  2. OEM/ODM Processing Full-process OEM & ODM services covering scheme design, R&D, production, testing and delivery, supporting customer brand labeling with sufficient production capacity and short delivery cycles.
  3. Confidential Cooperation Mechanism Sign non-disclosure agreements to strictly protect customer technical solutions, parameters and order information against technical leakage, suitable for military, government and confidential projects.
  4. Spot Quick Delivery Core products (SPD modules, distribution boxes, DCDUs) are in stock. Standard orders delivered within 3–7 days, emergency orders shipped within 24 hours to ensure project progress.

8.3 Technical & Quality Advantages

  1. Self-developed core technology Adopts self-developed varistor arrays, gas discharge tubes and TVS chips with stable lightning protection performance, low leakage current and strong anti-aging capacity, service life ≥10 years.
  2. Strict quality control Compliant with ISO9001 Quality Management System and ISO14001 Environmental Management System. All products pass 100% aging test, load test and lightning impulse test, certified by CE, UL, RoHS, TUV and other international standards, meeting industry specifications YD/T 5098, GB 18802.1, etc.
  3. Wide temperature environmental adaptation Industrial wide-temperature design operating at -40℃~+85℃, adapting to extreme environments including frigid northeast winters, desert high temperatures and coastal high humidity, with maximum IP67 protection grade.
  4. Modular easy maintenance Full-series modular design; SPD modules, power distribution loops and monitoring units support hot-swap replacement without power cut-off, simplifying maintenance and reducing O&M costs.

8.4 Full-series Technical Parameter Advantages

  1. SPD Modules: Discharge capacity ranging 10kA–120kA, residual voltage 0.6kV–1.5kV, response time 15ns–25ns, matching protection demands of all lightning zones.
  2. Distribution Boxes: Flexible AC/DC input & output configuration, IP30–IP67 protection grade, optional cold-rolled steel / aluminum alloy / 304 stainless steel material for indoor & outdoor scenarios.
  3. DCDU: Max input current 200A with 24 output channels (10A per channel), integrated lightning protection and current monitoring for high-power RRU loads of 5G base stations.
  4. Monitoring Modules: Multi-parameter monitoring, multi-protocol compatibility, complete remote O&M functions supporting data statistics & analysis to facilitate intelligent base station operation.

9. Bid-winning Control Parameters for All Products (Marked with ★)

9.1 Class B Lightning Protection Box (KITOZER-SPD-B60/B120)

  1. ★Rated Operating Voltage: 380/220VAC (50/60Hz)
  2. ★Impulse Discharge Capacity (Iimp): ≥60kA (10/350μs), High-tier ≥120kA
  3. ★Nominal Discharge Current (In): ≥40kA (8/20μs), High-tier ≥80kA
  4. ★Voltage Protection Level (Up): ≤1.5kV (8/20μs), High-tier ≤1.2kV
  5. ★Response Time: ≤25ns
  6. ★Protection Grade: ≥IP65
  7. ★Operating Temperature: -40℃~+85℃
  8. ★Communication Interface: RS485 + Dry Contact Remote Signal Support

9.2 Class C SPD Module (KITOZER-SPD-C20/C40/C60)

  1. ★Rated Operating Voltage: 220VAC (50/60Hz)
  2. ★Nominal Discharge Current (In): ≥20kA (8/20μs), Standard ≥40kA, High-tier ≥60kA
  3. ★Voltage Protection Level (Up): ≤1.2kV, Standard ≤1.0kV, High-tier ≤0.8kV
  4. ★Response Time: ≤25ns, High-tier ≤20ns
  5. ★Leakage Current: ≤30μA under normal operation
  6. ★Failure Indicator: Red window alarm, Green for normal state
  7. ★Mounting: Standard 35mm DIN Rail
  8. ★Flame Retardant Grade: UL94 V0

9.3 Class D SPD Module (KITOZER-SPD-D10/D20)

  1. ★Rated Operating Voltage: -48VDC
  2. ★Nominal Discharge Current (In): ≥10kA (8/20μs), High-tier ≥20kA
  3. ★Voltage Protection Level (Up): ≤0.8kV, High-tier ≤0.6kV
  4. ★Response Time: ≤20ns, High-tier ≤15ns
  5. ★Protection Mode: Full Line-Ground & Line-Line Protection
  6. ★Hot-swap Function: Supports live replacement without power cut-off
  7. ★Failure Alarm: Dry Contact + LED Indicator
  8. ★Operating Temperature: -40℃~+85℃

9.4 AC-DC Distribution Box (KITOZER-AC-D10/ACDC-D20/ACDC-D30)

  1. ★AC Input: 220VAC±20%, 50Hz; High-tier with automatic dual-power switching
  2. ★DC Input: -48VDC±10%
  3. ★Protection Grade: Indoor ≥IP30, Outdoor ≥IP54, High-tier ≥IP65
  4. ★Protection Functions: Integrated SPD, Overcurrent, Short-circuit, Overvoltage & Undervoltage Protection
  5. ★Operating Temperature: Indoor -30℃~+70℃, Outdoor -40℃~+85℃
  6. ★Material: Cold-rolled Steel / Aluminum Alloy / 304 Stainless Steel (High-tier)
  7. ★Output Channels: ≥4 AC circuits, ≥8 DC circuits

9.5 DC Power Distribution Unit (DCDU, KITOZER-DCDU-24)

  1. ★Input Voltage: -48VDC (-40VDC~-56VDC)
  2. ★Max Input Current: ≥200A
  3. ★Output Circuits: ≥24 circuits
  4. ★Single-circuit Output Current: ≥10A
  5. ★Integrated Functions: SPD, Overcurrent, Short-circuit & Reverse Polarity Protection + Per-circuit Current Monitoring
  6. ★Communication Interface: RS485 + Dry Contact Support
  7. ★Mounting: Standard 19-inch Rack (1U)
  8. ★Operating Temperature: -40℃~+85℃

9.6 Intelligent Monitoring / Remote O&M Module (KITOZER-MON-S10/S20)

  1. ★Monitored Parameters: SPD Status, Leakage Current, Residual Voltage, Ambient Temperature, Loop Voltage & Current
  2. ★Communication Interface: Standard RS485; High-tier with SNMP + Ethernet + Dry Contact
  3. ★Alarm Mode: Local Sound-light Alarm + Remote Environment Monitoring System Reporting
  4. ★Power Supply: 220VAC/-48VDC (Dual Power Redundancy for High-tier)
  5. ★Remote Functions: Parameter Configuration, Fault Reset, Data Query
  6. ★Mounting: 19-inch Rack (1U)
  7. ★Operating Temperature: -30℃~+70℃

9.7 Surge Backup Protector (SCB, KITOZER-SCB-60/100)

  1. ★Rated Operating Current: ≥60A, High-tier ≥100A
  2. ★Breaking Capacity: ≥25kA, High-tier ≥50kA
  3. ★Protection Characteristics: SPD Short-circuit, Overload & Overheat Protection
  4. ★Response Time: ≤100ns
  5. ★Flame Retardant Grade: UL94 V0
  6. ★Operating Temperature: -40℃~+85℃

10. Full Product Solutions

10.1 Solution for Indoor Base Stations in Ordinary Lightning Zones (Low-tier)

  • Applicable Scenarios: Urban / suburban 4G/5G macro base stations and indoor micro base stations with annual thunderstorm days <40 days and favorable machine room conditions.
  • Core Solution: Adopt Class C SPD modules + economical AC distribution boxes + equipotential bonding to build a Class II lightning protection system with 20kA discharge capacity, protecting AC power distribution and backend rectifiers, storage batteries and other equipment. Simplified monitoring reduces costs while meeting basic protection demands.
  • Implementation Key Points: Install SPD modules inside AC distribution boxes fixed on 35mm DIN rails; adopt 35mm² copper earthing cables with length ≤0.5m connected to machine room equipotential copper bars; maintain earthing resistance ≤4Ω and inspect SPD status regularly.

10.2 Solution for Indoor / Outdoor Base Stations in Medium Lightning Zones (Mid-tier)

  • Applicable Scenarios: Urban, suburban and rural 4G/5G macro base stations, 5G distributed base stations (BBU+RRU) with annual thunderstorm days 40–60 days, adaptable to both indoor and outdoor environments.
  • Core Solution: Deploy Class B lightning protection boxes + Class C SPD modules + Class D SPD modules + AC-DC integrated distribution boxes + intelligent monitoring modules to build a full B+C+D three-level lightning protection system with 60kA discharge capacity. It integrates AC/DC power distribution, intelligent monitoring and remote alarm functions for mixed-power supply base stations to secure AC & DC loads.
  • Implementation Key Points: Mount Class B lightning protection boxes at mains inlets with IP65 outdoor protection; install Class C modules at front ends of switching power supplies and Class D modules before BBU/RRU equipment; connect intelligent monitoring modules to environment monitoring systems for real-time SPD status tracking; adopt combined earthing grids with full equipotential bonding and earthing resistance ≤4Ω.

10.3 Solution for Outdoor Base Stations in Severe Lightning / Mountain / Coastal Zones (High-tier)

  • Applicable Scenarios: 4G/5G macro base stations, unattended base stations and edge computing base stations in mountainous, coastal, plateau and desert extreme environments with annual thunderstorm days >60 days and extremely high lightning risks.
  • Core Solution: Equip high-energy Class B lightning protection boxes + intelligent Class C SPD modules + precision Class D SPD modules + DCDUs + intelligent AC-DC distribution cabinets + remote O&M management modules + lightning strike counters to build an enhanced three-level lightning protection system with 120kA discharge capacity. It integrates dual-system hot standby, fault self-recovery, remote O&M and lightning strike counting functions, with 304 stainless steel outdoor cabinets of IP67 protection grade for extreme environments.
  • Implementation Key Points: Install dual-hot-standby high-energy Class B lightning protection boxes at tower bottom mains inlets; deploy redundant Class C modules and precision Class D protection; adopt DCDUs for centralized DC load distribution and intelligent cabinets for full-function protection & monitoring; equip combined earthing grids with resistance reducing agent to keep earthing resistance ≤1Ω; connect remote O&M modules to cloud platforms for 24/7 remote monitoring and maintenance.

10.4 Remote RRU Solution for 5G Distributed Base Stations

  • Applicable Scenarios: Remote RRU sites of 5G distributed base stations, mini outdoor base stations and pico base stations with -48VDC DC power supply, mounted on outdoor poles / iron towers.
  • Core Solution: Deploy Class D DC SPD modules + DC lightning-protected DCDUs + mini outdoor protective cabinets to build a DC-side three-level lightning protection system with 20kA discharge capacity. It integrates DC power distribution, SPD and overcurrent protection with compact IP65 cabinets for pole mounting, supporting hot-swap maintenance to lower O&M difficulty.
  • Implementation Key Points: Install Class D SPD modules at input & output terminals of DCDUs; fix DCDUs on outdoor poles with fully sealed waterproof cabinets; connect 35mm² copper earthing cables to RRU earthing terminals and tower earthing grids; maintain earthing resistance ≤4Ω and inspect waterproof sealing & earthing connections periodically.

11. Full Product Application Cases

11.1 5G Macro Base Station Lightning Protection Renovation Project of China Mobile Guangdong

  • Project Background: Coastal Guangdong regions (Shenzhen, Zhuhai, Shantou) belong to severe lightning zones with 65–80 annual thunderstorm days. Aging original lightning protection equipment caused 15–20 equipment damage incidents per year, with total communication outage duration exceeding 50 hours.
  • Solution: Deploy 1,200 sets of KITOZER high-tier enhanced lightning protection power distribution systems (B120 lightning box + C60 intelligent modules + D20 precision modules + DCDUs + remote O&M modules), covering 5G macro base stations across 21 coastal districts & counties.
  • Application Effect: Zero lightning-caused equipment damage for 24 consecutive months after renovation, communication outage duration reduced by over 95%; remote O&M cut on-site maintenance frequency by 60% and O&M costs by 40%; earthing resistance stably maintained ≤1Ω with fully compliant protection performance.

11.2 Mountainous 5G Distributed Base Station Project of China Telecom Sichuan

  • Project Background: High-altitude, severe lightning and low-temperature environments (-30℃~+30℃) in western Sichuan mountainous areas (Ganzi, Aba), with 800 5G distributed base stations (BBU+RRU) featuring long-distance RRU remote transmission and high risks of lightning strikes & low-temperature failure.
  • Solution: Adopt KITOZER mid-tier standard lightning protection power distribution systems (B60 lightning boxes + C40 modules + D10 modules + AC-DC integrated distribution boxes + intelligent monitoring modules) with IP65 outdoor protection and wide-temperature design (-40℃~+85℃).
  • Application Effect: Stable operation for 18 months, resisting multiple severe thunderstorms and extreme low temperatures without SPD failure or equipment damage; intelligent monitoring modules trigger alarms in real time, cutting fault response time to 15 minutes; compatible with mountain low-temperature environments with no equipment freezing or crash issues.

11.3 Rural 4G/5G Base Station Project of China Unicom Zhejiang Northern Plain

  • Project Background: Rural northern Zhejiang plain areas with 40–50 annual thunderstorm days, featuring widely distributed base stations with difficult O&M, requiring low-cost and high-reliability lightning protection power distribution solutions.
  • Solution: Deploy 2,000 sets of KITOZER low-tier economical lightning protection power distribution systems (C20 SPD modules + economical AC distribution boxes + equipotential bonding), covering rural base stations across 15 northern Zhejiang districts & counties.
  • Application Effect: Fast delivery and low cost meeting basic lightning protection demands for rural base stations; lightning damage rate reduced by 80% after 2 years of operation; modular design simplifies maintenance and raises rural site O&M efficiency by 50%; earthing resistance stably ≤4Ω with protection performance complying with industry standards.

11.4 Power Communication Base Station Project of State Grid East China

  • Project Background: State Grid East China power communication base stations (substations, transmission line monitoring stations) face strong electromagnetic interference and high lightning risks, requiring highly reliable and anti-interference lightning protection power distribution solutions.
  • Solution: Deploy KITOZER mid-tier standard lightning protection power distribution systems (B60 lightning boxes + C40 modules + D10 modules + AC-DC integrated distribution boxes + intelligent monitoring modules) compatible with power industry electromagnetic environments and certified for power sector use.
  • Application Effect: Stable operation for 3 years without downtime from strong electromagnetic interference or lightning surges, ensuring stable power communication links to support grid dispatching & monitoring services; remote monitoring adapts to unattended power station demands.

12. Common Product Faults & Maintenance Guidelines

12.1 Common Faults & Troubleshooting

12.1.1 SPD Module Faults

  1. Fault Phenomenon 1: SPD module red indicator light stays on (failure alarm)
    • Causes: Module aging, lightning strike damage, excessive leakage current, internal component breakdown.
    • Handling: Immediately replace with the same model SPD module; cut power before disassembly, pull out faulty module and insert new one with tight contact; test leakage current (≤30μA) and residual voltage (≤1.0kV) after replacement before restoring power supply.
  2. Fault Phenomenon 2: SPD indicator flashes with alarms
    • Causes: Module degradation, leakage current between 30–50μA, poor contact, excessive ambient temperature.
    • Handling: Clean terminal blocks with anhydrous alcohol, re-plug and fasten wiring terminals; check ambient temperature (≤85℃) and improve heat dissipation; replace module if flashing persists.
  3. Fault Phenomenon 3: No indicator light or alarm on SPD module
    • Causes: Open-circuited module, loose wiring, damaged indicator lamp.
    • Handling: Cut power and inspect loose wiring for re-fastening; test module continuity and replace if open-circuited; verify lightning protection performance post-replacement.

12.1.2 Distribution Box / DCDU Faults

  1. Fault Phenomenon 1: No output from distribution box, air switch tripped
    • Causes: Short-circuit / overcurrent of backend loads, short-circuited SPD module, line faults.
    • Handling: Disconnect all loads and close air switch, connect loads one by one to locate short-circuited / overcurrent loads; inspect and replace damaged SPD modules; test line insulation to eliminate circuit faults.
  2. Fault Phenomenon 2: Abnormal DCDU output voltage (too high / too low)
    • Causes: Abnormal input voltage, degraded SPD modules, internal circuit failure, overload loads.
    • Handling: Test input voltage (-48VDC±10%) and troubleshoot front-end power supply if abnormal; inspect SPD leakage current & residual voltage and replace degraded modules; reduce load to avoid overload; repair internal DCDU circuits or replace equipment if abnormality remains.
  3. Fault Phenomenon 3: Frequent alarms from distribution box / DCDU
    • Causes: Excessive ambient temperature, poor heat dissipation, loose wiring, faulty monitoring module.
    • Handling: Clear heat dissipation channels and improve ventilation; fasten all wiring terminals for reliable contact; calibrate or replace faulty monitoring modules; lower ambient temperature to avoid high-temperature operation.

12.1.3 Monitoring / O&M Module Faults

  1. Fault Phenomenon 1: No data upload from monitoring module, communication interruption
    • Causes: Loose communication cables, damaged interfaces, incorrect parameter configuration, faulty module.
    • Handling: Inspect RS485/Ethernet wiring, re-plug and fasten interfaces; verify communication parameters (baud rate, address, protocol) and reconfigure; replace monitoring module if no data is transmitted afterward.
  2. Fault Phenomenon 2: False alarms from monitoring module
    • Causes: Unreasonable alarm threshold settings, faulty sensors, environmental interference, incorrect wiring.
    • Handling: Recalibrate alarm thresholds (leakage current ≥50μA trigger alarm, temperature ≥85℃ trigger alarm); replace faulty sensors; eliminate environmental interference sources with shielding; correct miswired circuits.

12.2 Routine Maintenance Regulations

12.2.1 Daily Maintenance (Remote)

  • Check SPD status, leakage current, residual voltage, ambient temperature, power distribution voltage & current via remote O&M platform to confirm no active alarms.
  • View lightning strike count data, record strike frequency and analyze lightning risks for advance prevention.

12.2.2 Monthly Maintenance (On-site + Remote)

  • Inspect SPD indicator status on site, wipe dust off module surfaces and fasten wiring terminals.
  • Measure earthing resistance to ensure ≤4Ω (≤1Ω for severe lightning zones); troubleshoot earthing grids and add resistance reducing agent if unqualified.
  • Calibrate monitoring module parameters remotely and test normal alarm functionality.

12.2.3 Quarterly Maintenance (On-site)

  • Test SPD leakage current (≤30μA) and residual voltage (≤1.0kV) with lightning protection testers, replace degraded modules promptly.
  • Inspect internal wiring, air switches and fuses of distribution boxes / DCDUs, fasten loose terminals and replace aging accessories.
  • Clean heat dissipation channels of distribution boxes / DCDUs, inspect cooling fans (if equipped) for normal operation and proper heat dissipation.
  • Check sealing performance of outdoor protective cabinets and replace aging waterproof rubber strips to prevent rainwater intrusion.

12.2.4 Annual Maintenance (On-site, Before Thunderstorm Season)

  • Full inspection of lightning protection system: performance of B/C/D SPD modules, functionality of SCB backup protectors and reliability of equipotential bonding.
  • Replace aging SPD modules, wiring terminals, waterproof rubber strips and other accessories to guarantee qualified system performance.
  • Retest earthing resistance and optimize earthing grids to maintain ≤4Ω (≤1Ω for severe lightning zones).
  • Test remote O&M and alarm functions, connect to environment monitoring systems to ensure real-time fault reporting.

12.2.5 Maintenance for Long-term Decommissioned Equipment

  • Cut off the main air switch of distribution boxes to disconnect power supply if base stations are out of service for over 3 months.
  • Clean equipment surfaces for dust & moisture prevention, fully seal outdoor equipment against rain and dampness.
  • Check equipment status remotely monthly and conduct on-site inspections quarterly to avoid aging & damage.

13. Factory Strength & After-sales Service

13.1 Factory Strength

  1. Enterprise Qualifications KITOZER is a national high-tech enterprise specializing in R&D, production and sales of communication lightning protection power distribution equipment for 15 years. It holds ISO9001 Quality Management System and ISO14001 Environmental Management System certifications; products pass CE, UL, RoHS, TUV and other international certifications, complying with industry standards YD/T 5098, GB 18802.1, etc.
  2. R&D Capacity Independent R&D center with R&D team accounting for 30% of total staff; core technicians with over 10 years of experience in communication lightning protection, capable of self-developed chip, circuit and structural design, applying over 20 patents annually for continuous technical iteration.
  3. Production Scale 10,000㎡ standardized modern production workshop equipped with fully automatic production lines, SMT chip mounters, lightning impulse testers and high-low temperature aging chambers. Monthly output: 50,000 SPD modules, 5,000 distribution boxes, 3,000 DCDUs, meeting mass order delivery demands.
  4. Quality Control Full-process quality control system covering raw material procurement (premium international brand components), production assembly, debugging, aging test, lightning impulse test and finished product delivery. Every product undergoes 100% aging, load and lightning impulse testing to ensure zero-defect delivery.
  5. Cooperative Clients Long-term supplier for China Mobile, China Telecom, China Unicom, State Grid, China Southern Power Grid, Huawei, ZTE and other well-known enterprises. Products deployed across all 31 provincial-level regions of China and over 50 overseas countries & regions, with over 1 million sets installed and excellent market reputation.

13.2 After-sales Service

  1. Warranty Commitment 3-year free warranty for all products with lifetime maintenance; free component replacement & repair for non-human damage within warranty period; only component cost charged after warranty without labor fees.
  2. Fast Response 7×24-hour after-sales hotline; technical support responds to customer inquiries within 15 minutes after fault reporting; on-site service within 24 hours for major domestic cities and 48 hours for remote areas to resolve faults promptly.
  3. Technical Support Free technical selection, scheme design, wiring diagram design and installation & commissioning guidance; free online & offline technical training for customer operation & maintenance staff covering product principles, installation & debugging, daily maintenance and fault troubleshooting.
  4. Customization Service Product customization and OEM/ODM processing services with dedicated technical teams to align customer demands, rapidly complete scheme design and product R&D to guarantee project progress.
  5. Spare Parts Support Spot inventory of core products and sufficient stock of key spare parts (SPD modules, monitoring modules, air switches); emergency orders shipped within 24 hours to enable fast faulty component replacement and minimize downtime.
  6. Regular Follow-up Establish customer files with periodic follow-ups to track equipment operation status, provide maintenance suggestions and predict potential faults in advance for long-term stable equipment operation.

14. Conclusion

The KITOZER base station lightning protection power distribution module solution addresses core pain points of outdoor-deployed 4G/5G mobile communication base stations including severe lightning interference and complex environments, building a full-link protection system integrating three-level lightning protection, AC-DC integration, intelligent monitoring and remote O&M. It covers full-tier demands from economical to flagship, adapting to ordinary lightning zones, severe lightning zones, mountainous areas, coastal regions, deserts and all other scenarios.

Core products adopt self-developed technology and strict quality control, featuring large discharge capacity, low residual voltage, fast response, wide environmental adaptability and modular easy maintenance. Meanwhile, customized service and OEM/ODM processing with confidential cooperation mechanisms are provided to satisfy personalized demands of diverse customers.

Backed by robust factory capacity and comprehensive after-sales service system, KITOZER has delivered reliable lightning protection & power distribution solutions to massive base stations nationwide and overseas, effectively reducing risks of equipment damage and communication outages caused by lightning strikes to support stable operation of 4G/5G networks. Moving forward, KITOZER will continue to deepen its layout in the communication lightning protection power distribution sector, iterate product technology and optimize solutions to deliver higher-quality products and services for safe, stable and efficient operation of mobile communication networks.

15. Search Keywords, SEO & Tags

15.1 Search Keywords (Core + Long-tail)

  • Core Keywords: Base Station Lightning Protection Power Distribution Module, 4G/5G Base Station Lightning Protection, Base Station SPD Surge Protector, Base Station Power Lightning Protection Box, DCDU Lightning Protection Unit
  • Long-tail Keywords: Mountain Base Station Lightning Protection Solution, Coastal Base Station Lightning Protection Equipment, 5G Base Station AC-DC Lightning Protection & Power Distribution, Base Station Intelligent Lightning Protection Monitoring System, KITOZER Base Station Lightning Protection Module Manufacturer, Communication Base Station Three-level Lightning Protection, Low/Mid/High Tier Base Station Lightning Protection Power Distribution Equipment

15.2 SEO Optimization Content

  • Page Title: KITOZER Base Station Lightning Protection Power Distribution Module Solution – 4G/5G Base Station SPD Surge Protection
  • Page Keywords: Base Station Lightning Protection Power Distribution Module, 4G/5G Base Station Lightning Protection, Base Station SPD, Base Station Power Lightning Protection Box, DCDU Lightning Protection Unit
  • Page Description: KITOZER provides full-set lightning protection power distribution solutions for 4G/5G base stations, including B/C/D three-level lightning protection, AC/DC power distribution, intelligent monitoring and remote O&M functions, adaptable to mountainous, coastal and severe lightning base station scenarios. Customization & OEM processing available, direct factory supply with guaranteed quality.

15.3 Tags (Classification + Hot Tags)

  • Classification Tags: #BaseStationLightningProtection #CommunicationPowerDistributionEquipment #SPDSurgeProtector #5GBaseStationAccessory #PowerLightningProtectionBox
  • Hot Tags: #KITOZER #BaseStationLightningProtectionSolution #MountainBaseStationLightningProtection #CoastalBaseStationLightningProtection #IntelligentLightningProtectionMonitoring
Shopping Cart