KITOZER
KITOZER

KITOZER Bridge Monitoring System: Optical Deflection + Tilt + NOC Display for Long-Span Bridges

KITOZER Bridge Structural Health Monitoring System: Deflection, Tilt, Crack, Solar-powered IoT

KITOZER bridge structural health monitoring (SHM) system provides automated acquisition, transmission, analysis, and threshold-based early warning for in-service bridges. The four-layer architecture — sensor layer, acquisition/transmission layer, solar power/protection layer, and local platform — covers displacement, tilt, vibration, cracks, water level, temperature, humidity, and rainfall.

String-type deflection sensor for bridge and dam monitoring

1. Sensor Layer

Sensor Qty Key Specs
Photographic deflection meter 27 ±80m range, ≤55m measurement, ≤0.15mm accuracy, RJ45/RS485
Triaxial tilt-vibration unit 8 ±5°, 0.001° resolution, ±0.005° accuracy, RS485
Image crack gauge 17 ≤100m distance, 0.005mm resolution, ±0.02mm accuracy
8MP smart PTZ camera 9 360° pan/tilt, smart event recognition, outdoor
Radar water level gauge 2 ≥15m range, ±1mm accuracy, 4–20mA/RS485
Accelerometer / rain gauge / thermometer 1+1+2 ±2g triaxial / 0.2mm / IP68 -55~125°C

Dual-axis inclinometer tilt sensor for bridge monitoring

2. Acquisition & Transmission

Smart DAQ units (KITOZER-DAQ24-6E6S-2026) provide 24-bit A/D, ≥4 analog inputs, ≥6 Ethernet ports, ≥6 serial ports, BeiDou timing, 4G, and edge computing. Wired Ethernet is primary; 4G is backup with local buffering and auto-backfill after outages. Shielded signal cable (RVVSP 4×0.5), power cable (YJY 3×1.5), and PVC-coated stainless conduit protect field wiring.

Photographic deflection meter outdoor enclosure for bridge SHM

3. Solar Power & Protection

41 low-power monitoring points each use a 100W solar panel, 12.8V/40Ah LiFePO4 battery, and MPPT controller — mounted on 3m hot-dip galvanized poles with brackets and weather hoods. Designed for 3–5 days of continuous cloudy autonomy.

4. Local Platform

KITOZER-BHMS-L local platform handles point management, data acquisition/storage, curves/reports, threshold alerts, and access control. Administrators configure thresholds, permissions, and report templates from the web UI. Reference price ¥316,000 per project including deployment and training.

Bridge health monitoring NOC video wall with real-time curves

5. Reference Price

Typical configuration (27 deflection meters, 8 tilt units, 17 crack gauges, 4 DAQ enclosures, 41 solar power units): RMB ~¥3,857,000 (~USD 535,700), tax-inclusive delivered and installed. Final pricing subject to site survey and point re-verification.

About KITOZER

KITOZER bridge structural health monitoring systems provide automated acquisition, transmission, analysis, and early warning of displacement, tilt, vibration, cracks, water level, and environmental parameters for in-service bridges.

Tel/WhatsApp: +86 18520668845 | WeChat: +86 13922289957 | WhatsApp: +86 19068534140
Website: gdlain.com / lain.com.cn