The project requires the construction of a full-domain building intelligent automation control system that enables the following:
- Unified remote monitoring and automatic linkage control of air conditioning units, fresh air systems, water supply & drainage, public lighting, elevators, and power distribution equipment across the building.
- Real-time data acquisition of temperature, humidity, differential pressure, water pressure, current, and voltage.
- Automatic alarm (audible/visual + SMS) on equipment faults.
- Support for scheduled control strategies, energy consumption statistical reports, and remote access via mobile phone / PC web interface.
- System compatibility with BACnet and Modbus standard protocols.
- Local offline data caching and encrypted data storage.
- Suitable for smart operation and maintenance of commercial complexes, office buildings, and industrial park building electromechanical systems.
- No geographic or confidentiality restrictions; deployable in general commercial building scenarios.
3. System Composition Introduction
The complete building automation system adopts a three-layer architecture:
Perception Layer (Field Devices):
- Duct / pipe temperature and humidity transmitters
- Differential pressure sensors
- Water pressure and liquid level sensors
- Current and voltage acquisition modules
- Indoor COâ‚‚ sensors
- Water flow switches
Control Layer (Controllers & Actuators):
- DDC (Direct Digital Controller) zone controllers
- Zone control cabinets
- Electric two-way regulating valves
- Damper actuators
- Fan and pump variable frequency drives (VFDs)
- Communication acquisition gateways
Management Layer (Supervision & Software):
- Industrial monitoring workstations
- Building automation configuration (SCADA) software
- Network switches
- Audible & visual alarm terminals
- SMS alarm modules
- Data storage servers
4. Core Product Specifications & Parameters
KITOZER Duct Temperature & Humidity Transmitter — KT-BA-TH08
- Range: Temperature -30°C ~ 70°C; Humidity 0 ~ 100% RH
- Accuracy: ±0.3°C; ±2% RH
- Output: 4-20mA / RS485 dual output
- Protection rating: IP54
- Power supply: DC24V
KITOZER DDC Medium Controller — KT-DDC-100
- I/O: 12 analog inputs, 12 analog outputs, 12 digital inputs, 6 relay outputs
- Protocols: BACnet MS/TP, Modbus RTU
- Local storage: 30 days of operating data
- Offline auto-cache with batch upload on network recovery
KITOZER Building Automation Configuration Software V3.0 — KT-BA-SOFT-V3
- Unlimited point licensing
- WEB client + mobile mini-program
- Multi-account role-based permission levels
- Automatic daily / monthly / yearly energy consumption reports
- Customizable linkage logic and fault pop-up alarms
- OPC UA interface for third-party platform integration
KITOZER Electric Two-Way Regulating Valve — KT-FM-DN25
- Brass valve body, DN25 bore
- 24VAC drive; 0-10V proportional regulation
- Open/close response ≤ 12s
- With valve opening feedback signal
KT-GW-04 Industrial Communication Gateway
- 4 × RS485 ports, 1 × gigabit Ethernet port
- Dual protocol conversion
- Built-in hardware firewall
- Encrypted data transmission
- Auto-reconnect on line drop
5. Core Functions & Features of Products
Core Functions:
- Real-time visual monitoring of all mechanical and electrical equipment status — one-click view of fans, pumps, air conditioners, and lighting operating parameters.
- Automatic linkage start/stop of air conditioning, fresh air, and dehumidification equipment when temperature/humidity exceed set points, enabling constant temperature and humidity control.
- Scheduled on/off control of public lighting with human-body sensing linkage to reduce overall building energy consumption.
- Automatic alarm on abnormal water level / water pressure in water supply & drainage with linkage pump start/stop to prevent leaks and overflows.
- Triple alarm delivery (SMS, audible/visual, and platform pop-up) for equipment overload, fault, or offline events.
- Full-cycle energy data collection, statistics, comparison, and analysis with energy-saving optimization reports.
- Remote web and mobile mini-program access to the system, including remote control-strategy modification.
- One-year historical data storage with curve playback and fault record tracing for operation & maintenance audit compliance.
Product / System Features:
- Three-layer distributed architecture with independent zone control — a fault in one zone does not affect the entire building system.
- Dual protocol compatibility (BACnet / Modbus) — integrates with mainstream mechanical and electrical equipment without modification of existing devices.
- Local offline cache mechanism — automatic local control continues even if the external network is interrupted, with no data loss.
- All devices are industrial-grade protected for machine rooms, basements, rooftops, and other complex high/low-temperature, humid environments.
- Modular hardware with flexible point expansion — later additions do not require replacement of core controllers.
- No annual software fee — one-time purchase, permanent use, unlimited monitoring points.
6. Core Advantages of The Solution
- Integrated software & hardware R&D under the independent KITOZER brand — highly matched components with no third-party compatibility faults.
- Energy-saving algorithm optimization that reduces building mechanical & electrical energy consumption by 15%-25%, saving long-term operating costs.
- Role-based permission management (administrator, maintenance personnel, visitor) to safeguard system data security.
- Visual drag-and-drop linkage logic configuration — device linkage strategies can be customized without programming.
- Supports integration with fire protection, security, and energy monitoring systems for a unified smart building platform.
- Millisecond-level data acquisition response with fault alarm delay ≤ 1 second for rapid response to equipment safety hazards.
7. Manufacturer Strength Introduction
- KITOZER, operated by Guangzhou Lai’an Intelligent System Development Co., Ltd. (founded in 2002), is a high-tech enterprise certified to ISO 9001 / ISO 14001 / ISO 45001.
- Own production industrial park with full-process in-house manufacturing of sheet metal, sensors, and controllers — no middleman markup, stable supply cycle.
- Customization services available: point expansion, secondary development of software functions, and system integration customization.
- All products undergo a 72-hour burn-in test before shipment; warranty period of 24 months; lifetime free remote technical debugging.
- Proven track record with hundreds of completed projects in large commercial buildings, industrial parks, and office buildings.
- Pre-sales services include free on-site survey and solution design; post-sales services include nationwide on-site installation and commissioning guidance, with 7×24 technical support.
- Full supporting documentation delivered (drawings, operation manuals, test reports); bid documents can be prepared upon request.
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Duct Temperature & Humidity Transmitter | KT-BA-TH08 | -30~70°C, 0-100%RH, ±0.3°C accuracy, RS485/4-20mA, IP54 | 24 | Unit | 175.82 | 4219.68 | KITOZER | Deployed in each floor office area & machine room |
| 2 | Water Pipe Temperature Sensor | KT-BA-WT06 | 0-100°C, DN20 thread, DC24V, 4-20mA output | 16 | Unit | 142.96 | 2287.40 | KITOZER | Chilled/hot water pipeline |
| 3 | Air Differential Pressure Sensor | KT-BA-CY03 | 0-1000Pa, filter differential pressure monitoring, 0-10V output | 12 | Unit | 132.31 | 1587.69 | KITOZER | For fresh air units & AHUs |
| 4 | DDC Medium Zone Controller | KT-DDC-100 | 12AI/12AO/12DI/6DO, BACnet protocol, local storage | 8 | Unit | 2617.73 | 20941.84 | KITOZER | Per-floor zone control core |
| 5 | Electric Two-Way Regulating Valve DN25 | KT-FM-DN25 | Brass body, 24V proportional regulation, opening feedback | 32 | Set | 393.37 | 12587.83 | KITOZER | For fan coil units |
| 6 | Industrial Communication Gateway | KT-GW-04 | 4×RS485, gigabit Ethernet, dual protocol conversion | 4 | Unit | 1035.37 | 4141.48 | KITOZER | Cross-zone data aggregation |
| 7 | Building Automation Configuration Software V3.0 | KT-BA-SOFT-V3 | Unlimited point license, WEB + mini-program, energy reports, OPC UA | 1 | Set | 13273.35 | 13273.35 | KITOZER | Permanent license for whole system |
| 8 | Industrial Monitoring Workstation | KT-WS-IPC21 | 21.5″ touch screen, quad-core, 8GB RAM + 512GB SSD, industrial host | 1 | Unit | 3502.15 | 3502.15 | KITOZER | Central control room local monitoring terminal |
| 9 | 16-Port Gigabit Industrial Switch | KT-SW-16G | DIN-rail, surge protection, DC24V | 3 | Unit | 317.89 | 953.68 | KITOZER | Device networking & transmission |
| 10 | SMS Alarm Module | KT-AL-SMS02 | 4G full-network, multi-channel alarm push, power-off cache | 2 | Unit | 502.59 | 1005.18 | KITOZER | Dual terminal — duty room + property backend |
| 11 | Zone Control Cabinet (incl. breakers & terminals) | KT-CAB-BA12 | 12U cold-rolled steel, IP54, with wiring accessories | 8 | Unit | 690.84 | 5526.71 | KITOZER | DDC controller mounting cabinet |
| 12 | Fan/Pump Variable Frequency Drive 5.5KW | KT-VFD-5.5KW | 5.5KW, built-in PID, DDC linked speed regulation | 6 | Unit | 1908.24 | 11449.46 | KITOZER | Chilled water circulation pump & fresh air fan |
| 13 | COâ‚‚ Indoor Air Quality Sensor | KT-AQ-CO2 | 0-5000ppm, NDIR infrared, RS485 output | 18 | Unit | 231.76 | 4171.67 | KITOZER | Conference rooms, lobby & high-occupancy areas |
| 14 | Liquid Level / Water Pressure Acquisition Module | KT-MOD-LY01 | 4 analog inputs, water tank & pipe network pressure monitoring | 10 | Unit | 293.92 | 2939.17 | KITOZER | Water supply & drainage system |
| 15 | Audible & Visual Alarm Terminal | KT-AL-SG01 | 220V, high decibel, red warning light, relay linkage | 4 | Unit | 107.44 | 429.78 | KITOZER | Machine room & central control room on-site alarm |
Total Quotation Price: USD 89,081.55
*(Note: USD amounts are converted from the original CNY quotation at the fixed rate of 1 USD = 6.7570 CNY (CNY 601,924 total). Individual line items are rounded to 2 decimals; minor differences from line-item sums are due to rounding.)*
9. Quotation Terms & Conditions
- All prices above are quoted in USD (converted from CNY at the rate of 1 USD = 6.7570 CNY) and are EXW Guangzhou, China unless otherwise negotiated.
- The total quotation price of USD 89,081.55 excludes taxes, freight/logistics charges, and any on-site installation labor, cable, or auxiliary material costs (these may be quoted separately based on the actual site area).
- Tax options:
- Special VAT invoice: an additional 10% on the quotation total (CNY 601,924 × 1.10 = CNY 662,116.40 ≈ USD 97,989.82).
- Standard invoice: an additional 3% on the quotation total (CNY 601,924 × 1.03 = CNY 619,981.72 ≈ USD 91,753.84).
- Payment terms: 30% deposit with order, 70% balance before shipment (negotiable).
- Lead time: 15-30 working days depending on configuration and quantity.
- Validity of quotation: 30 days from the date of issue.
- Packing, insurance, and shipping costs are quoted separately upon request.
10. After-sales Service Description
- Standard product warranty: 12-24 months (this system carries a 24-month warranty) from the date of delivery.
- Lifetime free remote technical support and phone/online troubleshooting.
- Spare parts guaranteed to be available for the service life of the products.
- Remote troubleshooting and on-site installation & commissioning guidance / service options available nationwide.
- Free technical consultation for operation, maintenance, and system optimization throughout the equipment lifecycle.
11. Contact & Order Information
- Orders can be placed through the official KITOZER website at gdlain.com or by contacting the KITOZER sales team directly.
- All inquiries receive a response within 24 hours.
- For quotation clarification, technical pre-sales support, or customized system design, please contact the KITOZER sales department with your project requirements, building area, and point count to receive a tailored quotation.
12. SEO Keywords & Tags
KITOZER building automation system quotation, building automation system price list, building automation system factory price, wholesale building automation system quotation, KITOZER DDC controller quotation, duct temperature humidity sensor price, building BA control system complete quotation, commercial building M&E intelligent monitoring solution, office building automation system, industrial park BA control system, DDC controller complete equipment, building mechanical electrical energy monitoring system, central air conditioning automatic control system, public lighting intelligent management system, water supply drainage remote monitoring equipment, building automation SCADA software price, DDC controller technical parameters, building automation equipment manufacturer, cost of building automation system