2. Project Requirement Description
To ensure the safe and stable operation of public and private charging pile stations, centralized charging sites, and battery swap stations, and to mitigate safety hazards such as high temperature, water accumulation, combustible gas leakage, and fire incidents, a fully unattended intelligent operation and maintenance system is required. A complete set of charging pile environment monitoring systems shall be deployed.
The system is required to perform 7×24-hour uninterrupted collection and monitoring of site-wide environmental parameters, equipment operating status, security status, and electrical working conditions across all charging stations. It shall enable:
- Anomaly early warning
- Intelligent linkage control
- Data statistics and reporting
- Remote operation and maintenance
The system must comprehensively enhance the safety management capability and intelligent operation & maintenance level of charging pile stations, fully satisfying the safety operation specifications for new energy charging infrastructure.
3. System Composition Introduction
The complete charging pile environment monitoring system adopts a layered modular architecture, comprising four major layers:
Perception Layer
- Outdoor waterproof temperature and humidity sensor
- Photoelectric smoke detector
- Explosion-proof combustible gas sensor
- Water immersion / flooding sensor
- Access control magnetic door sensor
- Charging pile data acquisition unit
- HD video surveillance camera
- Audible and visual alarm device
Transmission Layer
- Industrial-grade 4G full-network transmission module
- Gigabit industrial Ethernet switch
- Shielded communication cables
- Supports wired + wireless dual-link transmission, with breakpoint resume and data encryption
Control Layer
- Dedicated monitoring host for charging pile stations
- Intelligent linkage control module
- Supports local data storage, logic computation, and automatic equipment linkage control
- Standalone operation capability even when network is disconnected
Platform Layer
- Charging pile environment intelligent monitoring cloud platform
- Enables centralized management of multiple stations, data visualization, alarm push notifications, report statistics, and remote debugging & maintenance
4. Core Product Specifications & Parameters
4.1 Charging Pile Station Monitoring Host
- Industrial-grade embedded high-end ARM processor, stable embedded Linux system
- 7×24-hour uninterrupted operation
- 12 RS485 communication interfaces, 12 DI/DO switch interfaces, 2 Gigabit Ethernet interfaces
- Built-in 4G full-network transmission module
- Local large-capacity storage, caching more than 6 months of historical data
- Automatic data saving upon network disconnection, automatic data resend upon reconnection
- Working temperature range: -20℃ ~ +60℃
- Wide voltage DC 12-48V power supply
- Protection rating: IP30
- Wall-mounted lightweight design, suitable for installation in charging pile power distribution rooms and station equipment rooms
4.2 Front-end Sensing and Monitoring Equipment
| Equipment | Key Parameters |
|---|---|
| Outdoor Temperature & Humidity Sensor | Range -30℃~+80℃, temp accuracy ±0.3℃, humidity accuracy ±2%RH, IP65 full waterproof & dustproof, RS485 Modbus protocol output, UV-resistant, weather-resistant |
| Photoelectric Smoke Detector | Compliant with national fire inspection standards, photoelectric detection principle, low false alarm rate, high sensitivity, relay switch output, suitable for fire monitoring in indoor power distribution areas of charging stations |
| Explosion-proof Combustible Gas Sensor | Industrial explosion-proof design, detects hydrogen, methane and other combustible gases, range 0~100%LEL, accuracy ±5%FS, response time ≤30s, suitable for EV charging leak monitoring |
| Water Immersion Sensor | High-sensitivity inductive detection, IP67 waterproof, accurately monitors low-lying areas, cable trench water seepage, and equipment water ingress risks |
| Charging Pile Acquisition Unit | Compatible with mainstream AC/DC charging pile protocols on the market, real-time acquisition of charging voltage, current, power, energy consumption, equipment fault codes, operating status and all parameters |
4.3 Monitoring Platform Parameters
- B/S cloud architecture, no client installation required
- Multi-terminal adaptive access via computer, mobile phone, tablet
- Supports unlimited number of charging station access points
- Data refresh interval ≤ 1s, alarm response ≤ 3s
- Built-in data statistics, curve analysis, alarm logs, equipment ledger, operation & maintenance report functions
- Supports Excel and PDF format data export and printing
5. Core Functions & Features of Products
Environmental Full-domain Monitoring
- Real-time collection of temperature, humidity, water accumulation, smoke, combustible gas concentration and other environmental parameters across charging stations
- Precisely captures station environmental anomalies
Charging Pile Operating Condition Monitoring
- Real-time monitoring of charging pile operating status, charging load, electrical parameters, fault information
- Precisely locates equipment fault points
Intelligent Linkage Control
- Supports custom linkage logic
- High temperature: automatically activate ventilation and heat dissipation equipment
- High humidity: activate dehumidification equipment
- Gas/smoke exceeding limit: activate audible & visual alarm with linkage to power-off protection
Multi-level Intelligent Alarm
- Supports level-by-level alarms for parameter exceeding limits, equipment offline, faults and anomalies, illegal intrusion
- On-site audible & visual alarm + remote APP/dual-channel SMS push notification
Security Linkage Monitoring
- Integrated video surveillance functions
- Automatic pop-up recording and snapshot retention upon alarm trigger
- Integrated environment + security integrated management
Multi-station Centralized Operation & Maintenance
- Supports unified access and management of multiple charging stations
- Remote debugging, parameter configuration, status inspection
- Realizes unattended operation & maintenance
Data Statistics & Analysis
- Automatically generates daily/monthly/yearly environment reports, equipment operation reports, and alarm statistics reports
- Provides data support for station safety operation and equipment maintenance
6. Core Advantages of The Solution
Industry-specific Solution
- Deep cultivation in the new energy charging infrastructure sector
- Closely aligned with charging pile station operation norms and safety standards
- Software and hardware deeply adapted to charging scenarios, eliminating general-purpose equipment adaptation defects
Zero-blind-spot Safety Control
- Multi-dimensional sensor monitoring + intelligent linkage protection
- Early hazard warning and rapid fault handling
- Significantly reduces station safety accident rate
Significant Cost Reduction & Efficiency Improvement
- Replaces traditional manual inspection mode
- Achieves unattended operation & maintenance
- Greatly reduces labor, inspection, and maintenance costs
- Improves station operation efficiency
Full-network Compatibility
- Compatible with 99% of mainstream domestic charging pile equipment brands
- Can connect to various charging operation management platforms
- No need to modify existing equipment, strong adaptability
Customized Service Capability
- Customized monitoring points, linkage logic, and platform interface based on station scale, equipment layout, and management requirements
- Adapts to differentiated needs of various projects
7. Manufacturer Strength Introduction
KITOZER is represented by Guangzhou Lai’an Intelligent System Development Co., Ltd. and Guangdong Lai’an Smart Machine Room Equipment Co., Ltd.
The company operates a standardized production industrial park in Panyu, Guangzhou, with complete production lines for sheet metal processing, electronic assembly, program debugging, and aging testing.
Key strengths include:
- KITOZER is an independent core brand deeply engaged in the energy monitoring field
- Full series of products are independently researched, developed, manufactured, and serviced — no middleman markup
- Factory holds dedicated R&D qualifications for new energy monitoring systems
- All products undergo strict high/low temperature aging, waterproof/dustproof, and EMC testing
- Compliant with power new infrastructure and new energy industry standards
- Large ready stock inventory available, supporting fast delivery, expedited customization, and project-specific solution implementation
- Professional technical team provides full-process installation guidance, debugging training, and lifetime technical after-sales support
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Charging Pile Station Monitoring Host | KTZ-CP-M01 | Industrial embedded, multi-interface, 4G transmission, local storage | 1 | Unit | $1,775.94 | $1,775.94 | KITOZER | Station monitoring core |
| 2 | Outdoor Temperature & Humidity Sensor | KTZ-TH-W2 | -30~+80℃, IP65 protection, RS485, high precision | 4 | Pcs | $110.99 | $443.95 | KITOZER | Station environment temp/humidity acquisition |
| 3 | Photoelectric Smoke Detector | KTZ-SM-CP01 | Photoelectric detection, fire standard, relay output, low false alarm | 4 | Pcs | $71.04 | $284.15 | KITOZER | Power distribution area fire monitoring |
| 4 | Explosion-proof Combustible Gas Detector | KTZ-GAS-CP02 | 0~100%LEL, explosion-proof design, response ≤30s, RS485 output | 2 | Pcs | $310.79 | $621.58 | KITOZER | Hydrogen/combustible gas leak monitoring |
| 5 | Point-type Water Immersion Sensor | KTZ-WL-CP01 | IP67 waterproof, high sensitivity, real-time flood/leak detection | 3 | Pcs | $53.28 | $159.83 | KITOZER | Low-lying area & cable trench water monitoring |
| 6 | Charging Pile Data Acquisition Unit | KTZ-CP-C01 | Compatible with mainstream charging pile protocols, full electrical parameter acquisition, fault identification | 2 | Units | $399.59 | $799.17 | KITOZER | Charging pile operation data integration |
| 7 | Intelligent Linkage Control Module | KTZ-CTRL-CP08 | 8 relay outputs, custom linkage logic, automatic equipment start/stop | 1 | Unit | $355.19 | $355.19 | KITOZER | Fan/ventilation equipment linkage control |
| 8 | Audible & Visual Alarm | KTZ-ALM-CP01 | High-decibel audible & visual alarm, red flashing warning, DC24V wide voltage | 2 | Pcs | $88.80 | $177.59 | KITOZER | On-site anomaly alarm notification |
| 9 | 5-port Gigabit Industrial Switch | KTZ-SW-05CP | Industrial DIN-rail type, wide temperature operation, anti-interference, Gigabit transmission | 1 | Unit | $266.39 | $266.39 | KITOZER | On-site equipment network setup |
| 10 | Charging Pile Monitoring Management Platform | KTZ-CP-V1.0 | B/S architecture, multi-station centralized management, alarm, report, remote O&M | 1 | Set | $6,215.78 | $6,215.78 | KITOZER | Permanent platform license deployment |
| 11 | Station Installation Auxiliary Materials Kit | KTZ-FC-CP | Including shielded cables, waterproof connectors, mounting brackets, terminals, cable trays — full accessory kit | 1 | Set | $355.19 | $355.19 | KITOZER | Project installation supporting use |
| 12 | System Commissioning & Technical Service Fee | KTZ-TS-CP01 | Equipment installation guidance, system commissioning, linkage configuration, personnel training | 1 | Item | $1,109.96 | $1,109.96 | KITOZER | Full-process technical implementation service |
| Total | $12,564.75 |
Total Quotation Price: USD 12,564.75
9. Quotation Terms & Conditions
1. Prices: All prices above are in USD, based on EXW Guangzhou, China (or as negotiated).
2. Taxes: The quotation excludes taxes and freight charges. For VAT special invoices, an additional 10% tax point applies; for VAT general invoices, an additional 3% tax point applies.
3. Shipping: Equipment is shipped via logistics. Freight is collected upon delivery (freight collect), paid on-site by the receiving party.
4. Warranty: Full series products carry a 3-year warranty. Within the warranty period, non-artificial damage is repaired, replaced, or upgraded free of charge.
5. Payment Terms: 30% deposit / 70% balance before shipment (negotiable).
6. Lead Time: 15-30 working days depending on configuration.
7. Validity: This quotation is valid for 30 days from the date of issue.
8. Packing: Packing and shipping costs are quoted separately.
10. After-sales Service Description
- Warranty: 12-24 months standard warranty per product (3 years for this system), covering free repair, replacement, and upgrade for non-artificial damage within the warranty period
- Lifetime Technical Support: Lifetime remote technical support and consulting services provided
- Spare Parts Availability: Full range of spare parts maintained in stock for rapid dispatch
- Remote Troubleshooting: Remote diagnostic and troubleshooting services available for quick issue resolution
- On-site Service: On-site installation guidance, commissioning, and training support available as needed
- Technical Team: Professional technical support team available to provide full-process installation guidance, commissioning training, and lifetime after-sales service
11. Contact & Order Information
Order Channels:
- Place orders through the official website: gdlain.com
- Or contact the KITOZER sales team directly
Manufacturer:
- Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Smart Machine Room Equipment Co., Ltd.
Brand:
- KITOZER
Project Contact:
- Contact person: Mr. Zhou
- Phone: +86 13538869979
Factory Address:
- Chaotian District, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China — Zhongrun Industrial Park
Response Commitment:
All inquiries will receive a response within 24 hours. Custom project requirements, OEM/ODM solutions, and bulk order quotations are welcome.
12. SEO Keywords & Tags
KITOZER quotation, charging pile environment monitoring system price list, charging station monitoring system quotation, charging pile safety monitoring system factory price, new energy charging station environment monitoring system, charging pile dynamic environment monitoring, EV charging station temperature and humidity monitoring, charging pile combustible gas monitoring system, charging station intelligent monitoring system quotation, charging pile environment monitoring system wholesale price, KITOZER charging station monitoring solution, charging pile security early warning system, charging pile environment monitoring system manufacturer, charging station monitoring system supplier, charging pile safety monitoring equipment configuration, new energy charging station environmental monitoring quotation, charging pile smoke and water immersion detection system, charging pile station unattended monitoring system price