Table of Contents
ToggleProduct Overview
KITOZER (Guangzhou Lain Intelligent System Development Co., Ltd.) offers a dedicated classified facility intelligent integration solution that unifies security surveillance, access control, electromagnetic shielding, confidentiality inspection, environmental monitoring, and network security into a single, compliant platform. Designed for high-security environments such as party and government agencies, military enterprises, classified research institutes, and confidential core departments, this solution strictly follows the national BMB series confidentiality standards, ensuring full compliance for personnel management, physical protection, electromagnetic safety, and audit traceability.
Product Introduction
The classified facility intelligent integration system integrates multiple subsystems—including classified video surveillance, multi-factor access control, electromagnetic shielding, confidentiality inspection, environmental monitoring (temperature, humidity, smoke, water leak, vibration), intrusion alarm, network security isolation, a classified management platform, power protection and grounding, and physical protection facilities—into one unified security architecture. Every component is selected for compliance with national classified protection requirements.
Product Positioning
This solution targets high-security classified units such as government secret-related departments, military enterprises, and research institutes. It is positioned as a secure and reliable infrastructure product that complies with national confidentiality regulations and meets hierarchical control requirements, supporting three levels of classified environments: secret, confidential, and top secret.
Core Value
- Full compliance with national confidentiality regulations, reducing leak risks.
- Multi-system linkage provides whole-area situational awareness; abnormal events trigger rapid alerts and responses.
- Unified management platform improves site security efficiency and reduces manual control costs.
- All operations are logged and auditable, meeting confidentiality inspection and traceability needs.
- Domestic (Chinese-made) equipment fully adapted, ensuring supply chain and technology self-control.
Product Highlights
- Designed strictly per national confidentiality standards, passing official security inspection and acceptance.
- Triple protection: electromagnetic shielding + physical security + network security.
- Multi-factor authentication and hierarchical permission control for precise personnel access.
- End-to-end encrypted data storage with full audit trail.
- Compatible with existing unit confidentiality management platforms for unified multi-site supervision.
Product Classification and System Components
Product Classification
By venue type:
- Classified computer room intelligent integration
- Secure meeting room integration
- Classified archives room integration
- Military industrial classified factory integration
By security level:
- Secret-level venue integration
- Confidential-level venue integration
- Top-secret-level venue integration
System Components
- Classified video surveillance system
- Multi-factor access control system
- Electromagnetic shielding system
- Confidentiality inspection system
- Environmental monitoring system (temperature, humidity, smoke, water leak, vibration)
- Intrusion alarm system
- Network security isolation system
- Classified management comprehensive platform
- Power protection and grounding system
- Physical protection auxiliary facilities
System Working Principle
The system centers on the classified management comprehensive platform, which uses a dedicated classified intranet in a closed loop to connect all security and control devices. It collects multi-dimensional data such as personnel access, video surveillance, environmental status, and electromagnetic signals in real time. Based on preset confidentiality control rules, the system automatically triggers abnormal behavior alerts, manages access permissions hierarchically, and operates shielding systems in linkage.
All operation logs and event data are encrypted and stored with full audit trail that cannot be tampered with, meeting confidentiality audit and traceability requirements. The system is physically isolated from the internet, eliminating any risk of data leakage through network channels.
Technical Parameters
- Electromagnetic shielding room: Shielding effectiveness ≥100dB (magnetic field), ≥110dB (electric field), compliant with BMB3-1999 standard.
- Access control system: Supports face/card/fingerprint/password multi-factor authentication; response time ≤0.5s; hierarchical permission management.
- Surveillance system: 2MP/4MP classified-specific cameras, H.265 encoding, encrypted storage for ≥90 days.
- Environmental monitoring: Temperature accuracy ±0.5°C, humidity accuracy ±3%RH, water leak detection localization accuracy ≤1m.
- The entire system is physically isolated with no external network interfaces, meeting classified information system hierarchical protection requirements.
Standard Product Configuration List
| No. | Equipment Name | Specifications | Qty | Unit | Remarks |
| —– | —————- | —————- | —– | —— | ——— |
| 1 | Classified management platform host | Domestic processor, encrypted storage | 1 | Set | System core |
| 2 | Classified access controller | Multi-factor authentication, hierarchical permissions | 2 | Unit | Entrance/exit control |
| 3 | Classified surveillance camera | 4MP, encrypted output | 10 | Unit | Configured as needed |
| 4 | Electromagnetic shielding cabinet | 700x700x1800mm, shielding effectiveness ≥80dB | 2 | Unit | Equipment protection |
| 5 | Environmental monitoring host | Temp/humidity/water leak/smoke access | 1 | Unit | Environmental control |
| 6 | Intrusion alarm host | Supports infrared and vibration detectors | 1 | Unit | Perimeter protection |
| 7 | Confidentiality inspection terminal | Electromagnetic leakage, red-black power detection | 1 | Unit | Compliance testing |
| 8 | Shielded cables and accessories | Classified shielded cables, conduit | 1 | Batch | Configured as needed |
Product Category Details
- Secret-level basic integration suite: Suitable for general classified office areas; includes basic security, access control, and environmental monitoring; meets secret-level compliance requirements.
- Confidential-level standard integration suite: For important classified venues; adds electromagnetic shielding, network isolation, and confidentiality inspection modules; meets confidential-level control standards.
- Top-secret-level high-end integration suite: For core classified spaces; features high-performance shielding rooms, multi-factor identity authentication, and full-dimensional monitoring; meets top-secret protection requirements.
- Classified computer room dedicated integration suite: Customized for classified computer rooms; integrates shielding, security, fire protection, and environmental control modules; meets classified computer room construction standards.
Materials and Craftsmanship Analysis
Material Details
- Shielding structure: 2mm high-quality cold-rolled steel plate + copper mesh shielding layer, excellent conductivity, stable shielding effectiveness.
- Shielding door: Beryllium copper leaf spring sealing, wear-resistant and corrosion-resistant, long-term shielding performance does not degrade.
- Transmission cables: Classified-specific shielded cables with double-layer shielding structure, strong anti-electromagnetic leakage capability.
- Equipment housing: Explosion-proof flame-retardant metal shell, meeting both fire protection and security standards.
- Sealing materials: Conductive rubber and electromagnetic sealing gaskets ensure shielding continuity at joints.
Core Craftsmanship Description
- Shielding room construction: Welded joint process with full seam welding and grinding to ensure continuous shielding effectiveness without breaks.
- Cabling process: Strong/weak current separation; all cables run through galvanized steel conduit with shielding protection; shielding sealing at wall penetrations.
- System debugging: Strictly follows national confidentiality inspection procedures, checking shielding effectiveness and safety performance item by item.
- Construction management: Fully closed-loop construction; all personnel certified; construction process fully recorded; meets confidentiality management requirements.
Safety Certifications and Qualifications
- National Secrets Bureau classified information system integration qualification
- National authoritative inspection certification for electromagnetic shielding rooms
- Security engineering enterprise first-level qualification
- ISO27001 information security management system certification
- 3C compulsory product certification
Stock Availability
Standard products such as basic security equipment, shielding cabinets, classified access control, and environmental monitoring devices are regularly in stock and can be shipped quickly. Customized shielding projects and top-secret level special solutions are produced and delivered according to agreed cycles; core spare parts maintain emergency inventory.
OEM and Confidentiality Services
We provide OEM customization for classified equipment, allowing adjustments to equipment appearance, labeling, parameters, and system interface to meet customer branding and adaptation needs.
Special confidentiality services: All projects sign a special confidentiality agreement; all personnel involved sign confidentiality commitments. Project materials, technical parameters, and customer information are managed under strict closed-loop control and are strictly prohibited from leaking. Construction processes strictly follow confidentiality regulations to ensure absolute security of classified information.
Product Attributes (SKU)
| SKU Code | Product Name | Applicable Security Level | Warranty Period |
| ———- | ————– | ————————— | —————– |
| LA-SM-001 | Secret-level basic integration suite | Secret | 1 year |
| LA-SM-002 | Confidential-level standard integration suite | Confidential | 1 year |
| LA-SM-003 | Top-secret-level high-end integration suite | Top secret | 2 years |
| LA-SM-004 | Classified computer room dedicated integration suite | Corresponding room level | 2 years |
Specification Summary Table
| System Module | Core Indicator | Unit | Execution Standard |
| —————- | —————- | —— | ——————– |
| Electromagnetic shielding system | Shielding effectiveness ≥100dB | dB | BMB3-1999 |
| Access control system | Authentication response time ≤0.5s | s | Confidential security standard |
| Video surveillance system | Encrypted storage, ≥90 days | Days | GB50348 |
| Environmental monitoring system | Temperature accuracy ±0.5°C | °C | Industry standard |
| Whole system | Physical isolation, no external interfaces | / | Hierarchical protection standard |
Core Competitive Advantages
Material Advantage
All core shielding and security materials pass national confidentiality inspection certification. Shielding materials use high-conductivity cold-rolled steel plate and copper mesh; cables use high-shielding-performance classified-specific wire materials, ensuring electromagnetic and physical security from the source.
Craftsmanship Advantage
We have a mature classified engineering construction team that strictly follows national confidentiality construction specifications. Shielding engineering craftsmanship is mature and stable; the project delivery pass rate for official confidentiality inspection is 100%.
Customization Advantage
We offer full-scene customization based on venue security level, spatial layout, and functional needs, adapting to the personalized control requirements of different classified units and supporting full adaptation of domestic equipment.
Cost Advantage
Our own shielding equipment production factory and standardized module production reduce site construction time and labor costs. Overall project cost is controllable, with better price-performance than industry average.
Quality Advantage
Full-process compliant quality control; every link meets national confidentiality standards. Pre-delivery testing and full functional testing ensure system compliance, stability, and reliability.
Application Scenarios
- Party and government confidential core departments
- Military enterprise classified factories and laboratories
- Research institute classified research centers
- Classified archives management centers
- Confidential meeting rooms
- Political and legal unit classified office areas
- Classified data center computer rooms
Customization Service Details
Customization Scope
- Security level adaptation: tailor protection solutions according to venue classification level.
- Space customization: custom shielding rooms and security layout per site dimensions.
- Function customization: add or remove control modules; integrate with existing classified management platforms.
- Domestic adaptation: configure fully domestic equipment and systems as required for compliance.
Customization Process
Confidential requirements survey → On-site survey → Compliant solution design → Confidential review of solution → Contract signing → Production and construction → On-site debugging → Pre-test rectification → Official inspection and acceptance → Operation and maintenance support.
Customization Advantages
We hold certified classified integration qualification teams; solution design is fully compliant, familiar with confidentiality inspection standards and processes. After delivery, we provide continuous compliance upgrades and technical support to keep the venue compliant long-term.
Success Case Showcase
Partner Clients
- A provincial-level confidential unit
- A military electronics research institute
- A political and legal agency classified office area
- A municipal classified archives management center
Case Highlights
- A military research institute classified facility integration project: covers 3 classified laboratories and 1 core classified computer room; passed the National Secrets Bureau first-level confidentiality qualification in one attempt; security control efficiency improved 60%; zero leak incidents.
- A political and legal unit confidential meeting room project: achieved full-band electromagnetic signal shielding, multi-factor access control, and encrypted recording of meetings; met the confidential meeting requirements of political and legal systems and passed special confidential inspections.
Product Troubleshooting
- Shielding effectiveness degradation: Check whether the shielding door sealing strip is aged or damaged, whether cable wall penetration sealing is loose, or whether the shielding body has openings or damage; have a certified technician perform sealing repair.
- Access control authentication failure: Check permission configuration, device power and network connection, and whether the card reader surface is obstructed; restart the access controller to test.
- Surveillance image abnormality: Check camera power, classified intranet connection, and encryption key matching status; have classified maintenance personnel troubleshoot; unauthorized personnel are prohibited from operating.
- Environmental alarm abnormality: Check sensor positioning and line connections; investigate whether there is an actual environmental anomaly; reset alarm and calibrate sensor for false alarms.
Note: Fault handling in classified venues must be performed by certified classified maintenance personnel. Unauthorized personnel are strictly prohibited from disassembling equipment or connecting external networks.
Daily Maintenance and Care
- Regularly inspect shielding door sealing components and wall penetration sealing; periodically test shielding effectiveness to ensure protection performance.
- Conduct regular confidentiality technical inspections; remove unauthorized devices; check for illegal external connection risks.
- Regularly back up system logs and audit data; data storage must comply with confidentiality management requirements.
- Equipment maintenance is performed by certified classified personnel; maintenance process is fully recorded; unauthorized storage devices are strictly prohibited.
Factory Strength and After-Sales Service System
We hold the classified information system integration qualification issued by the National Secrets Bureau, own a shielding equipment production factory and a professional classified engineering construction team. Core technical personnel hold confidentiality work certificates, and project experience covers multiple classified levels.
After-sales service: 7×24 hour confidential hotline technical support; classified faults handled by certified engineers on site. Free on-site maintenance during warranty period; lifelong confidential compliance consulting and technical upgrade services.
Procurement Service Guarantees
Supply Guarantee
Standard classified equipment is regularly in stock; we collaborate with legitimate classified equipment manufacturers, ensuring full traceability and project delivery progress.
Quality Guarantee
All equipment meets national confidentiality standards and provides formal inspection reports; construction strictly follows confidentiality specifications; delivery passes third-party confidentiality inspection and acceptance.
Logistics Guarantee
Classified equipment is delivered via dedicated vehicles with closed-loop personnel transport, ensuring confidentiality throughout; equipment and transportation process are safe and controllable.
After-sales Guarantee
Standard projects provide 1-3 years warranty, certified engineers on-site service, and lifetime confidentiality compliance consulting and technical support.
Invoice Guarantee
We can issue 13% VAT special invoice, compliant with regulations and can provide corresponding invoicing services per customer needs.
FAQ
Q: What qualification is needed to undertake classified facility integration projects?
A: Our company holds the classified information system integration qualification issued by the National Secrets Bureau, enabling us to undertake various classified facility intelligent integration projects.
Q: Can you guarantee passing confidentiality inspection?
A: Solution design strictly follows national confidentiality standards, construction is fully compliant, and pre-delivery testing is performed to ensure one-time pass of official confidentiality inspection.
Q: Can you integrate with our existing classified systems?
A: Yes, we support mainstream classified management platforms, classified access control, and surveillance systems, allowing full reuse of existing classified assets.
Q: Is on-site service during warranty extra charge?
A: Non-human-induced faults during warranty are repaired free of charge without additional fees.
Conclusion
Classified facility intelligent integration is vital technical support for confidentiality security. Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER) always puts compliance as the core and security as the bottom line. With professional qualifications and mature technology, we provide reliable, compliant, and efficient intelligent solutions for various classified units, strengthening the confidentiality defense line.
Contact Us
Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER)
Contact: Mr. Zhou, 13538869979 (WeChat same), 13538869979 (WeChat same)
Address: Chaitian Industrial Park, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou