ToggleProduct Overview
Our computer room leak monitoring system is a real-time monitoring and early warning solution designed to protect server rooms and data centers from the risks of water leaks from air conditioning, water pipes, and fire suppression systems. With high-precision sensing cables and intelligent controllers, it detects leaks quickly, pinpoints their location, and triggers immediate alerts, preventing costly equipment damage and downtime.
Product Positioning
This system is specifically engineered for environments where water damage can cause catastrophic failures. It provides continuous, unattended monitoring, ensuring even the smallest leak is detected and addressed promptly.
Core Value
- Prevention: Detect minute leaks before they escalate, avoiding equipment damage and business interruption.
- Accurate Location: Positioning systems pinpoint the exact leak point with accuracy up to ±0.5 meters, reducing troubleshooting time by 90%.
- Unattended Operation: 24/7 monitoring with multi-channel alerts eliminates the need for manual inspections.
- Automated Response: Integrates with solenoid valves and drainage pumps to automatically isolate water sources and mitigate damage.
- Compliance: Meets data center standards such as GB 50174 (Code for Design of Data Centers), supporting security certifications.
Product Highlights
- Positioning accuracy up to ±0.5 meters, quickly locating leaks with 90% faster troubleshooting.
- Anti-interference sensing cables that ignore dust and humidity, minimizing false alarms.
- Supports both positioning and non-positioning systems to suit different scenarios and budgets.
- Reusable sensing cables—simply wipe dry and the system resets, no replacement needed.
- High protection rating (IP67), ideal for underfloor and pipe-side installations.
- Seamless integration with environment monitoring systems for unified management and control.
Product Classification and Composition
Product Classification
- By detection range: Positioning, Non-positioning, Point-type
- By liquid type: Water, Acid/alkali, Oil
- By controller type: Wall-mounted, Rack-mount, Modular
System Composition
- Sensing cables: Laid in vulnerable areas, available in positioning (4-core) and non-positioning (2-core) variants.
- Controllers: Process signals, determine leaks, compute positions, output alerts, and upload data.
- Accessories: Termination ends, fixing clips, and lead wires.
- Optional actuators: Solenoid valves and drainage pumps for automated response.
Technical Specifications
Main System Specifications
| Parameter | Positioning System | Non-positioning System |
| ————————– | ————————– | ————————– |
| Max Detection Length | 200 meters | 500 meters |
| Positioning Accuracy | ±0.5% L + 0.5 m | No positioning function |
| Response Time | ≤2 seconds | ≤1 second |
| Power Supply | DC 12V / AC 220V | DC 12V / AC 220V |
| Communication Interface | RS485 + relay output | RS485 + relay output |
| Operating Temperature | -20°C ~ 60°C | -20°C ~ 60°C |
| Sensing Cable Protection | IP67 | IP67 |
| Alarm Methods | Sound/light + dry contact + platform alert | Sound/light + dry contact + platform alert |
| Reset Method | Automatic reset after wiping dry | Automatic reset after wiping dry |
Additional Specifications
- Detection Length per Controller: up to 200 meters
- Positioning Accuracy: ±(0.5% of cable length + 0.5 m), highest up to ±0.1 m
- Response Time: ≤2 seconds
- Communication Interfaces: RS485, RJ45, relay dry contacts
- Power Supply: DC 12V / AC 220V
- Working Environment: Temperature -20°C to 60°C, Humidity 0~100% RH
- Sensing Cable Protection Rating: IP67
SKU List
| SKU | Product Name | Model | Suitable Scenario | Unit |
| ———– | ———————————- | —————— | ————————– | —— |
| LSJK-001 | Positioning Leakage Controller | KITOZER-LS-DW | Positioning leak monitoring | Unit |
| LSJK-002 | Positioning Sensing Cable (per meter) | KITOZER-LS-X | Leak detection cable | Meter |
| LSJK-003 | Non-positioning Leakage Controller | KITOZER-LS-FD | Simple leak detection | Unit |
| LSJK-004 | Point Water Immersion Detector | KITOZER-LS-DS | Point leak detection | Piece |
Core Advantages
Material Advantages
- Sensing cables use high-density polyethylene (HDPE) outer sheath, corrosion-resistant and durable.
- Conductive wires are tin-plated copper for stable conductivity and oxidation resistance.
- Controllers feature flame-retardant ABS housing (V0 grade), moisture and dust proof.
- Premium high-precision analog chips ensure sensitivity and noise immunity.
Process Advantages
- Spiral winding structure suppresses electromagnetic interference, reducing false alarms.
- Potting/sealing process for controllers enhances moisture resistance.
- Waterproof injection-molded connectors guarantee reliable sealing (IP67).
- Factory leak simulation tests ensure detection sensitivity and reliability.
Customization Advantages
- Custom sensing cable lengths and special liquid detection (acid, alkali, oil).
- Custom controller features and alarm methods.
- Third-party system integration support.
- Tailored installation plans based on computer room layout.
Cost Advantages
- Reusable sensing cables eliminate replacement costs.
- Simple installation reduces labor expenses.
- Early warning prevents equipment damage and minimizes loss.
- High cost-effectiveness—small investment, significant protection.
Quality Advantages
- Strict production and testing: each cable and controller undergoes leak testing.
- High reliability with low false alarm rate.
- Industry certifications and third-party metrology validation.
- 1-year warranty and lifetime technical support.
Product Category Details
- Non-positioning Leak Monitoring System: Detects the presence of leaks without location identification. Cost-effective for small, simple areas.
- Positioning Leak Monitoring System: Precisely locates the leak position. Ideal for long pipelines and large computer rooms.
- Point Water Immersion Detector: Single-point detection for specific spots like under air conditioners or near floor drains.
- Multi-zone Leak Monitoring System: One host monitors multiple independent areas with zone-based alarms, suited for large data centers.
Materials and Process Analysis
Material Details
- Sensing Cable: Outer sheath of high-density polyethylene (HDPE), internal four-core or two-core tin-plated copper wire with spiral structure.
- Controller Housing: V0-grade flame-retardant ABS engineering plastic, moisture-proof and dust-proof, with excellent insulation.
- Conductive Core Wire: High-purity tin-plated copper with superior conductivity, oxidation resistance, and corrosion resistance.
- Lead Wire Cable: RVVP shielded cable, resistant to electromagnetic interference, suitable for complex electromagnetic environments.
Core Processes
- Spiral Braiding: The sensing cable’s core wires are spirally wound for uniform distribution, enhancing sensitivity and anti-interference capability.
- Waterproof Injection Molding: Connectors are integrally molded to achieve IP67 rating, preventing false alarms at connection points.
- Calibration and Debugging: Each controller is calibrated to a standard length before shipment to ensure positioning accuracy.
- Aging Test: Sensing cables undergo bend and corrosion tests to ensure long-term performance stability.
Safety Certifications
- CE and ROHS certifications.
- Compliant with GB 50174 (Code for Design of Data Centers) leak detection requirements.
- Positioning accuracy validated by third-party metrology.
Stock Availability
Standard 5m, 10m, and 20m positioning/non-positioning sensing cables, standard controllers, and common accessories are in stock. Orders ship within 24 hours. Custom lengths are delivered in 3-5 days.
OEM and Confidentiality
We offer OEM/ODM services for leak monitoring systems, including controller branding, custom packaging, and cable printing. Custom functions and parameters are available. Your plans and information are kept strictly confidential.
Application Scenarios
- Computer Rooms: Under precision air conditioners, along underfloor water pipes, near fire sprinkler pipes, and windows.
- Data Centers: Water pipe shafts, chilled water pipes, humidifier water lines, and cooling towers.
- Building Facilities: Underground parking, pump rooms, warehouses, and archive storage.
- Industrial Sites: Water and chemical liquid pipe leak detection in water plants and chemical facilities.
- Commercial Spaces: Leak monitoring for water and heating pipes in office buildings and shopping malls.
Customization Services
Customization Scope
- Hardware: Custom cable length, special liquid detection cables, controller appearance.
- Functionality: Custom alarm methods, linkage logic, third-party platform integration.
- Solution: Tailored installation plans based on computer room layout and leak risk points.
Customization Process
- Requirement consultation
- On-site survey
- Solution design and quotation
- Contract signing
- Custom production
- Installation and commissioning
- Acceptance and delivery
Customization Advantages
- Professional leak detection technical team with extensive computer room project experience.
- On-site survey available, ensuring solutions fit actual environments.
- Custom special liquid detection for acid, alkali, and oil scenarios.
- Full-service from design to installation and commissioning.
Success Cases
- A Large IDC: Deployed positioning leak monitoring across all air conditioners and piping, successfully detected 3 refrigerant leaks within 10 minutes, preventing any equipment loss.
- A Bank Data Center: Full-scope leak monitoring linked with fire and environment systems, automatic water shutoff on detection, passed Level 3 security assessment.
- An Archive Repository: 24/7 leak monitoring for all water pipes and windows, ensuring document safety.
Procurement Services
Stock Guarantee
- Regular specifications are kept in large stock; custom lengths are delivered quickly. Sufficient capacity for bulk orders to ensure project schedules.
Quality Assurance
- 100% leak simulation testing before shipment.
- 1-year free warranty for controllers, 2-year for sensing cables.
- Lifetime technical support.
Logistics Support
- Professional packaging prevents cable bending or damage.
- Express delivery with tracking, plus on-site installation service available.
After-sales Support
- 7×24 technical support with remote guidance.
- Fast replacement for quality issues.
- Free solution design and technical consultation.
Invoicing
- Can issue 13% VAT special invoices, compliant and shipped with goods or separately.
Conversion Module
Contact Information
- Phone: 13538869979 / 13538869979
- Website: https://gdlain.com
- Brand: KITOZER
- Address: Chaotian Park, Zhongrun Industrial Park, No.5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
Promotions
- New customers get 10% off first order.
- Free computer room leak risk assessment and installation plan.
- Bulk orders enjoy tiered discounts.
- Combined discounts when bundling with environment monitoring systems.
FAQs
Q: Do dust and humidity cause false alarms?
A: No. Our sensing cables use a specialized conductive polymer material that only triggers an alarm when in contact with conductive liquids. Dust, moisture, and condensation will not cause false alarms.
Q: Can the sensing cable be reused after a leak?
A: Yes. Simply wipe the liquid dry and the system automatically resets. The cable can be reused indefinitely, reducing long-term costs.
Q: How is it installed under the floor? Will it interfere with existing cabling?
A: Sensing cables are only a few millimeters in diameter and can be laid along floor supports without affecting other cables. Installation is simple and discreet.
Q: Can it automatically shut off the water valve?
A: Yes. The controller has relay outputs that can actuate solenoid valves to shut off the water source, or trigger drainage pumps for automatic mitigation.
Q: How accurate is positioning over long distances?
A: The positioning error is 0.5% of the cable length plus 0.5 meters. For example, a 100-meter cable has an error of about 1 meter, which is sufficient for on-site troubleshooting.
Troubleshooting and Maintenance
Common Faults and Solutions
- False Alarm: Check for water accumulation on the cable, damp connectors, or conductive debris nearby. Clean and dry to restore.
- No Alarm: Verify controller power supply, cable connection, and termination end.
- Inaccurate Positioning: Check calibration parameters, ensure no mid-line connections, and verify total cable length.
- Communication Error: Check communication wiring, address/baud rate settings, and controller status.
Daily Maintenance
- Regularly inspect cable laying areas for debris or water; keep clean.
- Check connector integrity and cable damage quarterly.
- Perform a simulated leak test annually to verify detection and alarm functions.
- Avoid heavy pressure or sharp objects on cables to prevent sheath damage.
- Keep controller dry and clean to prevent moisture and dust accumulation.
Factory Strength and After-sales Service
Factory Strength
- Dedicated leak detection product line with core detection algorithms and cable manufacturing processes.
- Automated cable production line with sufficient capacity.
- Years of computer room project experience, with strong solution design and implementation capabilities.
After-sales Service
- Warranty: 1-year free warranty for controllers, 2-year for sensing cables.
- Technical Support: 7×24 hotline for rapid response.
- On-site Service: Installation, commissioning, and testing available.
- Parts Supply: Long-term supply of accessories and extension cables.
- Lifetime Maintenance: Ongoing technical support and product maintenance.
Conclusion
Water leaks are a hidden threat to computer room safety, and even a small leak can cause severe equipment failure and business interruption. Our computer room leak monitoring system provides accurate detection, reliable quality, and complete solutions, building a comprehensive safety net for your valuable IT equipment. With early detection, rapid response, and elimination of leak risks, we help ensure uninterrupted operation and peace of mind.