Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Computer Room Precision Power Distribution Monitoring System

KITOZER Computer Room Precision Power Distribution Monitoring System Quotation List

Equipment RoomPrecisionWithElectricMonitoringSystem

2. Project Requirement Description

The computer room power system is the core infrastructure of the data center. Servers, storage devices, switches, UPS systems, and precision air conditioners all rely on stable power distribution. Ordinary electric meters can only provide rough readings of total power consumption and cannot perform refined real-time monitoring of each output circuit, three-phase busbar, UPS incoming line, or column head cabinet branch.

Project Requirements:

  • 7×24 hour uninterrupted collection of electrical parameters for all distribution circuits, including three-phase voltage, current, power, power factor, harmonics, electrical energy, and switch on/off status;
  • Support full-chain monitoring of main/standby dual-path ATS, UPS, precision power distribution cabinets, column head cabinets, and busway systems;
  • Graded alarm for power distribution anomalies: overcurrent, overload, phase loss, harmonic exceedance, switch tripping, insulation faults;
  • Local data storage for ≥2 years, with automatic generation of power distribution energy consumption reports and load trend curves;
  • Support integration with environment monitoring host, fire protection, and access control systems; power distribution faults automatically trigger audible/visual alarms, SMS/APP push notifications;
  • Full system industrial-grade anti-electromagnetic interference, suitable for high-density cabinet strong electromagnetic environments in computer rooms;
  • Integrated delivery of complete hardware + management software, supporting future point expansion.

3. System Composition Introduction

The KITOZER Computer Room Precision Power Distribution Monitoring System consists of three major layers: Sensing & Acquisition Layer, Transmission & Communication Layer, and Central Management Layer.

Sensing & Acquisition Layer:

  • Precision power distribution monitoring main module
  • Branch current acquisition modules
  • Split-core current transformers
  • Insulation monitoring unit
  • Power distribution cabinet touch screen display
  • Utility power/UPS protocol collectors

Transmission & Communication Layer:

  • Industrial RS485 bus
  • Dual network port acquisition gateway
  • Lightning protection communication isolators
  • POE powered switches

Central Management Layer:

  • Precision power distribution monitoring management software
  • Local monitoring server
  • Audible/visual alarm device
  • 4G SMS alarm module

4. Core Product Specifications & Parameters

Precision Power Distribution Main Monitoring Module — KITOZER-AMC100-Z

  • Input: Dual-path AC380V three-phase incoming lines, supporting main/standby dual power redundancy;
  • Monitoring channels: 4 incoming line three-phase full parameter acquisition, supporting voltage, current, active/reactive power, power factor, 2nd–31st harmonic, frequency, accumulated electrical energy;
  • Communication: 2× RS485 (Modbus-RTU), 1× RJ45 Ethernet Modbus TCP;
  • Protection: surge lightning protection, optoelectronic isolation, EMC Class B industrial electromagnetic compatibility;
  • Operating environment: -20°C ~ 70°C, humidity 0~95% RH non-condensing;
  • Installation: DIN rail standard cabinet mounting.

48-Channel Branch Acquisition Module — KITOZER-AMC100-F48

  • Single module supports up to 48 single-phase branch monitoring, cascading expands to max 192 output circuits;
  • Comes with split-core current transformers — no power-off installation required, 0-100A wide-range acquisition;
  • Supports passive dry contact acquisition of branch switch status.

Power Distribution Cabinet Touch Screen Display — KITOZER-ATP07

  • 7-inch industrial touch LCD screen, local real-time display of one-line power distribution diagram and all circuit parameters;
  • Local graded alarm pop-ups, supports on-site threshold parameter configuration.

Power Distribution Monitoring Management Software V5.0

  • B/S architecture, browser access without client installation;
  • Data storage cycle ≥24 months, data acquisition every 1 minute;
  • Supports Excel energy report export, load heat map, 24-hour trend curves;
  • Open API interface for integration with computer room environment monitoring master platform.

5. Core Functions & Features of Products

  • Full-circuit real-time electrical parameter monitoring: Real-time refresh of current, voltage, power, electrical energy, and harmonics for incoming lines, UPS, and every output of column head cabinets;
  • Switch status online monitoring: Real-time upload of circuit breaker trip, close, and fault status; records switch operation logs;
  • Insulation fault monitoring: Real-time detection of insulation resistance between busbar/branch to ground, early warning of short-circuit hazards;
  • Multi-level threshold alarms: Graded push notifications for overload, overvoltage, undervoltage, phase loss, harmonic exceedance, and power outage;
  • Energy consumption statistical analysis: Daily/weekly/monthly/yearly statistics of total computer room energy consumption and per-cabinet itemized energy consumption, generating energy-saving analysis reports;
  • Event recording and traceability: Stores all alarm, operation, and fault records, supporting historical data playback;
  • Multi-channel alarm push: Local audible/visual, SMS, WeChat Official Account, mobile APP, and email alarms;
  • Cross-system integration: Power distribution faults link with air conditioning, access control, and fire protection systems; abnormal events automatically trigger video recording;
  • Remote operation and maintenance management: Web-based remote threshold modification, data viewing, report export, and cloud-based remote access.

6. Core Advantages of The Solution

  • High-precision acquisition: Current accuracy ±0.2%, voltage accuracy ±0.1%, harmonic analysis accuracy down to 2nd harmonic — far exceeding ordinary power meters;
  • Full-chain coverage: Unified monitoring of utility power input, ATS switching, UPS output, column head cabinets, and cabinet branches with zero monitoring blind spots;
  • Reduced O&M costs: Replaces manual daily inspections; automatic fault location reduces power outage troubleshooting time by 70%;
  • Refined energy consumption control: Precisely tracks electricity usage per cabinet, supporting data center PUE optimization and energy-saving retrofits;
  • Strong compatibility: Compatible with all brands of UPS, precision power distribution cabinets, and ATS dual-power switching devices;
  • Safety & compliance: Meets classified protection (Dengbao) and data center computer room construction standards; power distribution monitoring logs serve as security audit evidence;
  • Flexible deployment: Wired RS485 + Ethernet dual transmission; supports local server deployment or cloud platform deployment.

7. Manufacturer Strength Introduction

KITOZER, a brand of Guangzhou Lai’an Intelligent System Development Co., Ltd., was founded in 2002 and is a certified high-tech enterprise holding ISO 9001, ISO 14001, and ISO 45001 certifications.

  • Own sheet metal, software, and sensor R&D and production lines, offering four core services: customization, OEM manufacturing, confidentiality projects, and stock products;
  • Self-owned industrial park production base in Guangzhou — all KITOZER brand equipment is self-manufactured with no outsourcing;
  • One-stop supply of the full series of computer room power distribution and environment monitoring products, backed by a professional commissioning and installation technical team;
  • Project cases cover government/enterprise computer rooms, IDC data centers, classified/confidential computer rooms, and university computer centers;
  • Warranty standards: 3-year free hardware warranty, lifetime free software upgrades and remote technical support;
  • Full-process services available: on-site survey, solution customization, on-site installation and commissioning, and completion training;
  • Flexible business terms: project prepayment options, phased delivery, and dedicated one-on-one technical liaison for each project.

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Precision Power Distribution Main Monitoring Module KITOZER-AMC100-Z Dual-path three-phase incoming, 4 incoming line acquisition, RS485 + Ethernet, DIN rail mounting 1 Unit 870.21 870.21 KITOZER Host core unit, incl. communication lightning protection
2 48-Channel Branch Acquisition Module KITOZER-AMC100-F48 48-channel single-phase branch monitoring, cascade expansion, dry contact switch acquisition 3 Unit 541.66 1624.98 KITOZER For monitoring 3 column head cabinets
3 Split-Core Current Transformer KITOZER-AKH0.66-W 0-100A split-core, no power-off installation, accuracy class 0.2 144 Pcs 20.42 2940.48 KITOZER Matches 48-channel modules
4 Busbar Insulation Monitoring Unit KITOZER-ZJY02 Dual busbar insulation resistance real-time monitoring, fault alarm output 1 Unit 630.46 630.46 KITOZER Main distribution cabinet insulation monitoring
5 7-Inch Industrial Touch Screen Display KITOZER-ATP07 Industrial LCD, local one-line power distribution diagram, threshold setting 2 Unit 435.10 870.20 KITOZER Local operation terminal for distribution cabinets
6 Industrial Acquisition Gateway KITOZER-GW485 4-channel RS485 to Ethernet, optoelectronic isolation, dual network port redundancy 1 Unit 683.73 683.73 KITOZER Data aggregation upload to environment monitoring platform
7 POE Industrial Switch KITOZER-SW08P 8-port POE powered, gigabit transmission, lightning protection 1 Unit 381.83 381.83 KITOZER Power supply & transmission for gateway and display
8 Audible/Visual Alarm Device KITOZER-ALM01 85dB high-decibel, red/yellow lights, relay linked triggering 2 Unit 102.11 204.22 KITOZER One for computer room, one for monitoring room
9 4G SMS Alarm Module KITOZER-SMS4G Full network compatible, multi phone number alarm push 1 Unit 319.67 319.67 KITOZER Offline SMS alarm backup channel
10 Power Distribution Monitoring Management Software V5.0 KITOZER-POWER-V5 B/S architecture, 24-month data storage, report export, API integration 1 Set 2752.70 2752.70 KITOZER Permanent license, lifetime free upgrades
11 Local Monitoring Server (Industrial PC) KITOZER-IPC4U 4U industrial host, 8G RAM, 1T SSD, 7×24-hour operation 1 Unit 2486.31 2486.31 KITOZER Local data storage & software operation
12 Supporting Installation Accessories (Cables, Brackets, Terminals) Customized Communication shielded cable, DIN rails, mounting brackets, wiring terminals 1 Batch 643.78 643.78 KITOZER Full set of installation consumables
Total — — — — — — 14408.57 — Excluding tax & freight; VAT special invoice +10%, VAT regular invoice +3%, freight collect

Total Quotation Price: USD 14408.57

9. Quotation Terms & Conditions

  • Currency: All prices are quoted in US Dollars (USD).
  • Price Basis: EXW Guangzhou, China (or as negotiated).
  • Payment Terms: 30% deposit with order, 70% balance before shipment (negotiable for project-based agreements).
  • Lead Time: 15–30 working days depending on configuration and order quantity.
  • Validity: This quotation is valid for 30 days from the date of issue.
  • Packing & Shipping: Packing and freight costs are quoted separately; international logistics arrangements are subject to negotiation.
  • Tax: Prices exclude tax. VAT special invoice +10%, VAT regular invoice +3%, as applicable.
  • Warranty: Hardware products carry a 3-year free warranty; software includes lifetime free upgrades.

10. After-sales Service Description

  • Warranty Coverage: 12–24 months standard warranty per product (KITOZER precision power distribution products carry 3-year free hardware warranty);
  • Lifetime Technical Support: Free remote technical support for the lifetime of the product;
  • Spare Parts Availability: Original spare parts are guaranteed to be available for the product lifecycle;
  • Remote Troubleshooting: Professional engineers provide remote diagnosis and troubleshooting support;
  • On-site Service: Field installation, commissioning, and maintenance services available upon request;
  • Software Upgrades: Lifetime free software upgrades and feature enhancements;
  • Training: Remote or on-site operation training available for customer engineering teams.

11. Contact & Order Information

To place an order or request more information, please contact the KITOZER sales team through any of the following channels:

  • Official Website: www.gdlain.com
  • Brand: KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.)
  • Order Process: Submit inquiry → Technical confirmation → Contract & payment → Production → Quality inspection → Shipping → After-sales service
  • Response Time: All inquiries receive a response within 24 hours.
  • Customization: OEM/ODM, custom configuration, and project-based solutions are available upon request.

12. SEO Keywords & Tags

KITOZER quotation, computer room precision power distribution monitoring system price list, data center power monitoring equipment quotation, column head cabinet branch monitoring module price, IDC power distribution monitoring system cost, computer room UPS power monitoring equipment wholesale price, precision power distribution monitoring module manufacturer, computer room energy consumption monitoring system quotation, KITOZER precision power distribution system price, data center PUE monitoring equipment factory price, computer room power distribution alarm system cost, server room power monitoring solution pricing