Table of Contents
Toggle1. System Overview
The constant temperature & humidity container for energy storage is an integrated temperature control protection equipment developed by KITOZER exclusively for energy storage scenarios. It integrates four core technologies: high-precision temperature and humidity regulation, high-efficiency thermal insulation & sealing, intelligent monitoring linkage, and energy storage safety protection. It can stably maintain an internal environment with temperature accuracy of ±0.5℃ and humidity accuracy of ±2% RH under extreme ambient temperatures ranging from -40℃ to +80℃. It provides a safe operating space with constant temperature, constant humidity, dustproof, explosion-proof and anti-corrosion performance for core components such as energy storage battery packs, PCS, BMS and fire-fighting equipment.
Widely applied to grid energy storage, industrial & commercial energy storage, energy storage supporting photovoltaic/wind power, emergency energy storage power stations and other scenarios, it features modular integration, rapid deployment, flexible relocation and low energy consumption operation. It serves as the core infrastructure for outdoor deployment of energy storage systems.
2. System Composition
The KITOZER constant temperature & humidity container system adopts a modular layered architecture, consisting of 10 core subsystems that coordinate linkage and independent control to guarantee stable and efficient system operation:
- Container Structure Subsystem Adopts standard ISO container frames (20ft/40ft). The outer wall is made of weather-resistant steel/stainless steel, the inner wall of SUS304 stainless steel, and the middle layer filled with high-density polyurethane foam insulation (50-100mm thick). Double-layer door sealing delivers windproof, rainproof, dustproof, anti-corrosion, impact-resistant and flame-retardant performance.
- Cooling & Heating Subsystem Core components include KITOZER customized scroll compressors (cooling) and stainless steel electric heating tubes (heating), matched with high-efficiency condensers, evaporators and electronic expansion valves. Cooling and heating capacity can be customized to match energy storage capacity.
- Humidification & Dehumidification Subsystem Integrates electrode humidifiers (humidification capacity: 0.5-5kg/h) and refrigeration dehumidification modules (dehumidification capacity: 10-50L/d), paired with high-precision humidity sensors to realize closed-loop precise humidity control and prevent condensation and corrosion of energy storage equipment.
- Ventilation & Air Exchange Subsystem Composed of explosion-proof axial fans, electric air dampers and air filters, with adjustable fresh air exchange volume (0-500m³/h). Linked with combustible gas detectors to timely discharge flammable gas generated by thermal runaway of energy storage equipment and reduce safety risks.
- Intelligent Monitoring Subsystem Equipped with KITOZER industrial-grade PLC controllers, supporting temperature/humidity sensors, smoke sensors, combustible gas sensors, door magnetic sensors, voltage/current sensors for real-time data collection and upload. It supports local touch control and remote monitoring.
- Energy Storage Integration Subsystem Built-in battery racks, insulating partitions, cable trays and grounding devices, compatible with lithium iron phosphate / ternary lithium battery packs. Reserved installation interfaces for PCS, BMS and fire-fighting equipment to meet energy storage system integration requirements.
- Power Distribution Subsystem Three-phase five-wire AC380V/50Hz input, equipped with UPS power supply, air switches, residual current protectors, surge arresters and terminal blocks. It ensures stable power supply for the whole system with overvoltage, undervoltage, overload and short-circuit protection functions.
- Fire Protection Subsystem Fitted with heptafluoropropane gas fire extinguishing devices, smoke & temperature composite detectors, sound-light alarms, emergency lighting and evacuation indicators. Linked with BMS to realize thermal runaway early warning and automatic fire suppression for energy storage safety.
- Noise Reduction & Thermal Insulation Subsystem Sound-absorbing cotton attached to the inner wall of the container, shock-absorbing pads installed at the base of equipment, and silencers configured at air vents to reduce equipment operating noise (≤60dB) while enhancing thermal insulation and cutting energy consumption.
- Auxiliary Function Subsystem Includes LED explosion-proof lighting, emergency escape doors, observation windows, cable sealing glands, forklift slots and lifting lugs to meet installation, operation & maintenance and emergency requirements.
3. System Classification
KITOZER constant temperature & humidity containers are categorized by four dimensions: size, temperature control precision, energy storage capacity and protection rating, covering full-scenario demands from low to high specifications.
3.1 Classification by Size
- 20ft Standard Type External dimensions: 6058mm×2438mm×2591mm; internal dimensions: approx. 5400mm×2200mm×2300mm. Compatible with 100-500kWh energy storage capacity. Compact and flexible for distributed energy storage and household energy storage.
- 20ft High Cube Type External dimensions: 6058mm×2438mm×2896mm; internal dimensions: approx. 5400mm×2200mm×2600mm. Compatible with 500-1000kWh energy storage capacity. Larger internal space for integrating more energy storage equipment.
- 40ft Standard Type External dimensions: 12192mm×2438mm×2591mm; internal dimensions: approx. 11500mm×2200mm×2300mm. Compatible with 1000-2000kWh energy storage capacity, suitable for industrial & commercial energy storage and small & medium-sized energy storage power stations.
- 40ft High Cube Type External dimensions: 12192mm×2438mm×2896mm; internal dimensions: approx. 11500mm×2200mm×2600mm. Compatible with 2000-5000kWh energy storage capacity. Sufficient space for integrated assembly of BMS, PCS and fire-fighting systems.
3.2 Classification by Temperature Control Precision
- Standard Precision (Economical Type) Temperature range: -10℃ ~ +50℃, precision ±1℃; Humidity range: 30%RH-70%RH, precision ±5%RH. Suitable for energy storage scenarios with general temperature & humidity requirements, low cost and high cost performance.
- High Precision (Standard Type) Temperature range: -25℃ ~ +60℃, precision ±0.5℃; Humidity range: 20%RH-80%RH, precision ±3%RH. Applied to mainstream energy storage scenarios, balancing precision and cost.
- Ultra-High Precision (High-End Type) Temperature range: -40℃ ~ +80℃, precision ±0.2℃; Humidity range: 10%RH-90%RH, precision ±1%RH. Designed for high-demand scenarios including precision energy storage, laboratory energy storage and military energy storage.
3.3 Classification by Energy Storage Capacity
- Small Energy Storage (Low Configuration) Compatible with 100-500kWh energy storage capacity, temperature control power 5-10kW, basic monitoring configuration, meeting demands of small distributed energy storage.
- Medium Energy Storage (Medium Configuration) Compatible with 500-2000kWh energy storage capacity, temperature control power 10-30kW, intelligent monitoring & linkage control, applicable to industrial park energy storage.
- Large Energy Storage (High Configuration) Compatible with 2000-5000kWh energy storage capacity, temperature control power 30-80kW, redundant design + remote operation & maintenance + upgraded safety protection, for large energy storage power stations and grid peak shaving energy storage.
3.4 Classification by Protection Rating
- IP54 (Basic Protection): Dustproof and splash-proof, for indoor or sheltered energy storage deployment.
- IP65 (Standard Protection): Dustproof and water jet resistant, for outdoor open-air deployment in rainy and dusty environments.
- IP67 (High-End Protection): Dustproof and resistant to short-term immersion, for extreme harsh environments such as coastal saline-alkali areas and heavy rain zones.
4. System Schematic Diagrams
4.1 Temperature Control System Schematic (Cooling/Heating/Humidification/Dehumidification)
Core Process:
- Temperature and humidity sensors collect real-time internal data and transmit to PLC controllers.
- Data is compared with set thresholds: High temperature → Activate cooling cycle (compressor → condenser → electronic expansion valve → evaporator → circulation); Low temperature → Activate electric heating.
- High humidity → Activate refrigeration dehumidification (water condensed on evaporator → drainage); Low humidity → Activate electrode humidifier.
- Ventilation linkage: When combustible gas concentration exceeds the limit, explosion-proof fans and electric dampers start to discharge harmful gas.
- Cold/hot air and moisture circulate through T-shaped floor and air ducts to achieve uniform temperature and humidity distribution inside the container.
4.2 Energy Storage Integration System Schematic
Core Architecture: Energy storage battery pack → BMS battery management system → PCS energy storage converter → Grid-connected/off-grid interface The internal power distribution system supplies power to BMS, PCS, temperature control and fire-fighting systems. Fire-fighting system linked with BMS: Thermal runaway early warning → Automatic fire suppression + Power cut-off Intelligent monitoring system collects real-time data of battery voltage, current, temperature and internal environmental parameters, and uploads data to remote platforms.
4.3 Electrical System Schematic
Core Circuit: AC380V mains input → Surge arrester → Air switch → UPS power supply → Each subsystem (temperature control, monitoring, fire protection, energy storage) Equipped with leakage, overvoltage, undervoltage, overload and short-circuit protection. PLC controllers communicate with all sensors and actuators (compressors, fans, heaters, humidifiers) to realize automatic control. Supports RS485/CAN communication interfaces to connect upper computers or remote monitoring platforms.
5. Complete System Configuration List (KITOZER Brand, Low/Medium/High Configurations)
5.1 Low Configuration List (Small Energy Storage, 20ft Standard, IP54, 100-500kWh)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Constant Temperature & Humidity Container | KTZ-CON-20S-L | Outer size:6058×2438×2591mm; Inner size:5400×2200×2300mm; Outer wall: weather-resistant steel, inner wall:SUS304; 50mm PU insulation; IP54, flame retardant & anti-corrosion | 1 | Set | KITOZER | 20ft standard basic model |
| 2 | Scroll Compressor | KTZ-COMP-5KW-L | Cooling capacity 5kW, power 1.5kW, AC220V, R407C refrigerant, IP54 mute design | 1 | Set | KITOZER | Core cooling component |
| 3 | Condenser | KTZ-COND-5KW-L | Heat exchange area 2.5㎡, copper tube & aluminum fin, fan power 0.3kW, air volume 800m³/h, anti-rust coating | 1 | Set | KITOZER | Heat dissipation component |
| 4 | Evaporator | KTZ-EVAP-5KW-L | Heat exchange area 2㎡, copper tube & aluminum fin, fan power 0.2kW, air volume 600m³/h, antibacterial coating | 1 | Set | KITOZER | Heat absorption component |
| 5 | Electronic Expansion Valve | KTZ-EEV-1.5KW-L | Bore 1.5mm, working pressure 3MPa, DC24V, precise flow control | 1 | Pc | KITOZER | Refrigerant flow control |
| 6 | Electric Heating Tube | KTZ-HEAT-3KW-L | Power 3kW, AC220V, stainless steel, dry-burning prevention, insulation resistance ≥5MΩ | 1 | Pc | KITOZER | Low-temperature heating |
| 7 | Electrode Humidifier | KTZ-HUM-0.5KG-L | Humidification capacity 0.5kg/h, power 0.8kW, AC220V, water shortage protection & automatic cleaning | 1 | Set | KITOZER | Humidity compensation |
| 8 | Refrigeration Dehumidification Module | KTZ-DEHU-10L-L | Dehumidification capacity 10L/d, power 0.6kW, AC220V, operating temp 10-35℃, automatic defrosting | 1 | Set | KITOZER | Dehumidification & humidity control |
| 9 | Explosion-proof Axial Fan | KTZ-FAN-300-L | Air volume 300m³/h, power 0.15kW, AC220V, ExdⅡBT4 explosion-proof, IP54 | 2 | Set | KITOZER | Ventilation & air exchange |
| 10 | Electric Air Damper | KTZ-VALVE-300-L | Caliber 300mm, power 0.1kW, AC220V, switch type with tight sealing | 1 | Pc | KITOZER | Fresh air control |
| 11 | PLC Controller | KTZ-PLC-BASIC-L | 8DI/6DO, DC24V, RS485, 7-inch local touch screen, basic logic control | 1 | Set | KITOZER | Core system controller |
| 12 | Temperature & Humidity Sensor | KTZ-SENSOR-TH-L | Temp range -10~+50℃, ±1℃ accuracy; Humidity 30-70%RH, ±5%RH accuracy; DC24V, IP54 | 2 | Pc | KITOZER | Ambient monitoring |
| 13 | Smoke Sensor | KTZ-SENSOR-SM-L | Photoelectric type, sensitivity 0.15dB/m, DC24V, alarm output, IP54 | 1 | Pc | KITOZER | Fire early warning |
| 14 | Combustible Gas Sensor | KTZ-SENSOR-GAS-L | Detect methane/hydrogen, range 0-100%LEL, ±3% accuracy, DC24V, linkage output, IP54 | 1 | Pc | KITOZER | Combustible gas monitoring |
| 15 | UPS Power Supply | KTZ-UPS-1KVA-L | 1kVA capacity, 0.8kW, AC220V input/output, 30min backup, voltage stabilization | 1 | Set | KITOZER | Emergency power supply |
| 16 | Air Switch | KTZ-SWITCH-32A-L | 32A rated, 3P, short-circuit/overload protection, AC380V, IP54 | 2 | Pc | KITOZER | Circuit protection |
| 17 | Residual Current Protector | KTZ-RCD-32A-L | 32A rated, 30mA leakage trip, 3P+N, AC380V, IP54 | 1 | Pc | KITOZER | Leakage protection |
| 18 | Surge Arrester | KTZ-SPD-40KA-L | 40kA discharge capacity, protection voltage ≤1.5kV, AC380V, Class III protection, failure indicator | 1 | Pc | KITOZER | Lightning protection |
| 19 | Heptafluoropropane Fire Extinguishing Device | KTZ-FIRE-4KG-L | 4kg agent, 5.8% extinguishing concentration, startup pressure 1.2MPa, auto/manual startup, residue-free | 1 | Set | KITOZER | Fire suppression |
| 20 | LED Explosion-proof Lamp | KTZ-LIGHT-20W-L | 20W, AC220V, ExdⅡBT4, IP65, 2000lm brightness | 2 | Pc | KITOZER | Internal lighting |
| 21 | Emergency Escape Door | KTZ-DOOR-ESCAPE-L | 800×1900mm, steel, escape lock, sealing strip, IP54 | 1 | Pc | KITOZER | Emergency evacuation |
| 22 | Cable Gland | KTZ-GLAND-50-L | 50mm caliber, brass, waterproof & dustproof, fit cable OD 40-50mm | 4 | Pc | KITOZER | Cable sealing |
5.2 Medium Configuration List (Medium Energy Storage, 20ft High Cube, IP65, 500-2000kWh)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Constant Temperature & Humidity Container | KTZ-CON-20H-M | Outer size:6058×2438×2896mm; Inner size:5400×2200×2600mm; Galvanized steel outer wall with nano coating, SUS304 inner wall; 80mm PU insulation; IP65, UV resistant | 1 | Set | KITOZER | 20ft high cube standard medium model |
| 2 | Scroll Compressor | KTZ-COMP-15KW-M | Cooling capacity15kW, power4.5kW, AC380V, R410A eco refrigerant, IP65, low-temperature startup | 1 | Set | KITOZER | High-efficiency energy-saving cooling core |
| 3 | Condenser | KTZ-COND-15KW-M | Heat exchange area6㎡, copper tube & aluminum fin, fan power0.8kW, air volume2000m³/h, self-cleaning anti-rust coating | 1 | Set | KITOZER | High-efficiency heat dissipation |
| 4 | Evaporator | KTZ-EVAP-15KW-M | Heat exchange area5㎡, copper tube & aluminum fin, fan power0.5kW, air volume1500m³/h, anti-frost antibacterial coating | 1 | Set | KITOZER | Uniform temperature control heat absorption |
| 5 | Electronic Expansion Valve | KTZ-EEV-4KW-M | Bore4mm, working pressure4MPa, DC24V, intelligent precise flow regulation | 1 | Pc | KITOZER | Precise refrigerant flow control |
| 6 | Electric Heating Tube | KTZ-HEAT-8KW-M | Power8kW, AC380V, SUS316 stainless steel, dry-burning & overheat protection, insulation resistance≥10MΩ | 2 | Pc | KITOZER | Fast low-temperature heating |
| 7 | Electrode Humidifier | KTZ-HUM-2KG-M | Humidification capacity2kg/h, power1.5kW, AC220V, water shortage/humidity excess protection, automatic cleaning & scale alarm | 1 | Set | KITOZER | Precise humidity compensation |
| 8 | Refrigeration Dehumidification Module | KTZ-DEHU-30L-M | Dehumidification capacity30L/d, power1.2kW, AC220V, operating temp5-40℃, intelligent defrost & humidity control | 1 | Set | KITOZER | High-efficiency anti-condensation dehumidification |
| 9 | Explosion-proof Axial Fan | KTZ-FAN-500-M | Air volume500m³/h, power0.3kW, AC220V, ExdⅡBT4, IP65, low noise | 4 | Set | KITOZER | Forced rapid ventilation |
| 10 | Electric Air Damper | KTZ-VALVE-500-M | Caliber500mm, power0.2kW, AC220V, switch & regulating dual type, anti-condensation tight seal | 2 | Pc | KITOZER | Precise fresh air regulation |
| 11 | PLC Controller | KTZ-PLC-STD-M | 16DI/12DO, DC24V, RS485/CAN, 10-inch touch screen, intelligent linkage & programmable logic | 1 | Set | KITOZER | Intelligent system control core |
| 12 | Temperature & Humidity Sensor | KTZ-SENSOR-TH-M | Temp range -25~+60℃, ±0.5℃ accuracy; Humidity 20-80%RH, ±3%RH accuracy; DC24V, IP65 high precision | 4 | Pc | KITOZER | Multi-point ambient monitoring |
| 13 | Smoke Sensor | KTZ-SENSOR-SM-M | Composite photoelectric & ion type, sensitivity0.1dB/m, DC24V, fault self-check & alarm output, IP65 | 2 | Pc | KITOZER | Accurate fire early warning |
| 14 | Combustible Gas Sensor | KTZ-SENSOR-GAS-M | Detect methane/hydrogen/CO, range0-100%LEL, ±2% accuracy, DC24V, concentration display & linkage output, IP65 | 2 | Pc | KITOZER | Multi-gas monitoring |
| 15 | UPS Power Supply | KTZ-UPS-3KVA-M | 3kVA capacity, 2.4kW, AC380V input, AC220V output, 60min backup, voltage purification & stabilization | 1 | Set | KITOZER | Long-duration emergency power supply |
| 16 | Air Switch | KTZ-SWITCH-63A-M | 63A rated, 3P, short-circuit/overload/leakage protection, AC380V, IP65 | 3 | Pc | KITOZER | Multi-stage circuit protection |
| 17 | Residual Current Protector | KTZ-RCD-63A-M | 63A rated, 30mA leakage trip, 3P+N, AC380V, IP65 delay protection | 2 | Pc | KITOZER | Dual leakage protection |
| 18 | Surge Arrester | KTZ-SPD-60KA-M | 60kA discharge capacity, protection voltage ≤1.2kV, AC380V, Class IV protection, remote alarm & failure indicator | 2 | Pc | KITOZER | Comprehensive lightning protection |
| 19 | Heptafluoropropane Fire Extinguishing Device | KTZ-FIRE-8KG-M | 8kg agent, 5.8% extinguishing concentration, startup pressure1.5MPa, auto/manual/remote startup, eco residue-free | 2 | Set | KITOZER | Zoned fire suppression |
| 20 | LED Explosion-proof Lamp | KTZ-LIGHT-30W-M | 30W, AC220V, ExdⅡBT4, IP65, 3000lm brightness, emergency backup | 4 | Pc | KITOZER | High-brightness explosion-proof lighting |
| 21 | Emergency Escape Door | KTZ-DOOR-ESCAPE-M | 900×2000mm, stainless steel, escape lock with observation window, waterproof sealing strip, IP65 | 1 | Pc | KITOZER | Safe emergency evacuation |
| 22 | Cable Gland | KTZ-GLAND-80-M | 80mm caliber, nickel-plated brass, waterproof/dustproof/explosion-proof, fit cable OD60-80mm | 6 | Pc | KITOZER | Sealing protection |
| 23 | T-type Floor | KTZ-FLOOR-T-M | High-strength aluminum alloy, T-slot design, load capacity5t/㎡, ventilation & drainage, anti-corrosion | 1 | Set | KITOZER | Air circulation & load bearing |
| 24 | Remote Monitoring Module | KTZ-MONITOR-REMOTE-M | 4G/Ethernet support, real-time data upload, remote control, abnormal alarm, mobile APP & PC terminal | 1 | Set | KITOZER | Remote operation & maintenance management |
5.3 High Configuration List (Large Energy Storage, 40ft High Cube, IP67, 2000-5000kWh)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Constant Temperature & Humidity Container | KTZ-CON-40H-H | Outer size:12192×2438×2896mm; Inner size:11500×2200×2600mm; SUS316 stainless steel outer & inner wall; 100mm PU insulation; IP67, anti-salt spray & aging resistant | 1 | Set | KITOZER | 40ft high cube flagship high-end model |
| 2 | Scroll Compressor | KTZ-COMP-40KW-H | Single unit cooling capacity40kW, power12kW, AC380V, R410A eco refrigerant, dual redundant, IP67, wide-temperature startup | 2 | Set | KITOZER | Dual redundant stable cooling |
| 3 | Condenser | KTZ-COND-40KW-H | Heat exchange area15㎡, copper tube & aluminum fin, fan power2kW, air volume5000m³/h, self-cleaning anti-corrosion coating | 2 | Set | KITOZER | Redundant high-efficiency heat dissipation |
| 4 | Evaporator | KTZ-EVAP-40KW-H | Heat exchange area12㎡, copper tube & aluminum fin, fan power1.5kW, air volume4000m³/h, uniform air distribution anti-frost antibacterial coating | 2 | Set | KITOZER | Dual redundant uniform heat absorption |
| 5 | Electronic Expansion Valve | KTZ-EEV-10KW-H | Bore10mm, working pressure5MPa, DC24V, intelligent regulation & redundant backup | 2 | Pc | KITOZER | Redundant precise flow control |
| 6 | Electric Heating Tube | KTZ-HEAT-20KW-H | Single set power20kW, AC380V, SUS316L stainless steel, dry-burning/overheat protection, constant temperature control, insulation resistance≥15MΩ | 4 | Pc | KITOZER | Uniform fast heating |
| 7 | Electrode Humidifier | KTZ-HUM-5KG-H | Humidification capacity5kg/h, power3kW, AC220V, water shortage/humidity excess/scale protection, automatic cleaning & remote monitoring | 2 | Set | KITOZER | Ultra-precise humidity compensation |
| 8 | Refrigeration Dehumidification Module | KTZ-DEHU-50L-H | Dehumidification capacity50L/d, power2kW, AC220V, operating temp -5~50℃, intelligent defrost & redundant backup | 2 | Set | KITOZER | Powerful anti-condensation dehumidification |
| 9 | Explosion-proof Axial Fan | KTZ-FAN-800-H | Air volume800m³/h, power0.5kW, AC220V, ExdⅡBT4, IP67, low noise anti-corrosion | 6 | Set | KITOZER | High-efficiency anti-corrosion ventilation |
| 10 | Electric Air Damper | KTZ-VALVE-800-H | Caliber800mm, power0.3kW, AC220V, regulating type with feedback signal, anti-condensation anti-corrosion tight seal | 3 | Pc | KITOZER | Precise fresh air regulation |
| 11 | PLC Controller | KTZ-PLC-HIGH-H | 32DI/24DO, DC24V, RS485/CAN/Ethernet, 15-inch touch screen, redundant linkage & programmable logic | 2 | Set | KITOZER | Dual redundant control core |
| 12 | Temperature & Humidity Sensor | KTZ-SENSOR-TH-H | Temp range -40~+80℃, ±0.2℃ accuracy; Humidity10-90%RH, ±1%RH accuracy; DC24V, IP67 anti-interference high precision | 8 | Pc | KITOZER | Full-area precise monitoring |
| 13 | Smoke Sensor | KTZ-SENSOR-SM-H | Triple composite (photoelectric/ion/temperature), sensitivity0.05dB/m, DC24V, fault self-check & remote alarm, IP67 | 4 | Pc | KITOZER | Multi-dimensional fire early warning |
| 14 | Combustible Gas Sensor | KTZ-SENSOR-GAS-H | Detect methane/hydrogen/CO/hydrogen sulfide, range0-100%LEL, ±1% accuracy, DC24V, concentration display & remote linkage alarm, IP67 | 4 | Pc | KITOZER | Full-spectrum gas monitoring |
| 15 | UPS Power Supply | KTZ-UPS-10KVA-H | 10kVA capacity, 8kW, AC380V input, AC220V output, 120min backup, voltage purification & redundant output | 2 | Set | KITOZER | Dual redundant emergency power supply |
| 16 | Air Switch | KTZ-SWITCH-100A-H | 100A rated, 3P, short-circuit/overload/leakage/overvoltage protection, AC380V, IP67 | 4 | Pc | KITOZER | Full-range circuit protection |
| 17 | Residual Current Protector | KTZ-RCD-100A-H | 100A rated, 30mA leakage trip, 3P+N, AC380V, IP67 delay redundant protection | 3 | Pc | KITOZER | Triple leakage protection |
| 18 | Surge Arrester | KTZ-SPD-80KA-H | 80kA discharge capacity, protection voltage ≤1.0kV, AC380V, Class V protection, redundant remote alarm & failure indicator | 3 | Pc | KITOZER | Top-tier lightning protection |
| 19 | Heptafluoropropane Fire Extinguishing Device | KTZ-FIRE-16KG-H | 16kg agent, 5.8% extinguishing concentration, startup pressure1.8MPa, auto/manual/remote/BMS linkage startup, eco residue-free redundant design | 4 | Set | KITOZER | Zoned redundant fire suppression |
| 20 | LED Explosion-proof Lamp | KTZ-LIGHT-50W-H | 50W, AC220V, ExdⅡBT4, IP67, 5000lm brightness, emergency backup anti-corrosion | 6 | Pc | KITOZER | Ultra-bright anti-corrosion explosion-proof lighting |
| 21 | Emergency Escape Door | KTZ-DOOR-ESCAPE-H | 1000×2100mm, SUS316 stainless steel, escape lock with bulletproof observation window, double-sided opening waterproof anti-corrosion sealing strip, IP67 | 2 | Pc | KITOZER | Bidirectional safe evacuation |
| 22 | Cable Gland | KTZ-GLAND-100-H | 100mm caliber, nickel-plated anti-corrosion brass, waterproof/dustproof/explosion-proof, fit cable OD80-100mm | 8 | Pc | KITOZER | Anti-corrosion sealing protection |
| 23 | T-type Floor | KTZ-FLOOR-T-H | High-strength SUS316 aluminum alloy, T-slot modular splicing, load capacity10t/㎡, ventilation/drainage anti-corrosion | 1 | Set | KITOZER | Heavy-load air circulation floor |
| 24 | Cloud Remote Operation & Maintenance Platform | KTZ-PLATFORM-CLOUD-H | Cloud data storage, real-time monitoring, remote control, abnormal alarm, data analysis & report generation, multi-terminal compatible | 1 | Set | KITOZER | Cloud intelligent operation & maintenance |
| 25 | Shock-absorbing Base | KTZ-BASE-DAMP-H | High-strength carbon steel with shock-absorbing rubber, load capacity20t, shock absorption efficiency≥80%, anti-corrosion with fixing bolts | 1 | Set | KITOZER | Stable equipment shock absorption |
6. Full Product Technical Parameters
6.1 Container Technical Parameters
- Material: Outer wall (Low: weather-resistant steel; Medium: galvanized steel with nano coating; High: SUS316 stainless steel); Inner wall SUS304/SUS316 stainless steel; High-density PU foam insulation (50mm/Low,80mm/Medium,100mm/High)
- Sizes: 20ft Standard (6058×2438×2591mm); 20ft High Cube (6058×2438×2896mm); 40ft High Cube (12192×2438×2896mm)
- Protection Rating: Low IP54; Medium IP65; High IP67
- Load Capacity: Floor ≥5t/㎡(Low), ≥8t/㎡(Medium), ≥10t/㎡(High); Top ≥2t/㎡
- Operating Temperature Range: Low -10℃~+50℃; Medium -25℃~+60℃; High -40℃~+80℃
- Humidity Range: Low 30%RH-70%RH; Medium 20%RH-80%RH; High 10%RH-90%RH
- Flame Retardant Grade: GB8624-2012 Class B1 (Hardly Flammable)
- Service Life: ≥15 years(Low), ≥20 years(Medium), ≥25 years(High)
6.2 Cooling & Heating Component Parameters
6.2.1 Scroll Compressor
- Low: Cooling capacity5kW, power1.5kW, AC220V, R407C, IP54, noise ≤55dB
- Medium: Cooling capacity15kW, power4.5kW, AC380V, R410A eco refrigerant, IP65, noise ≤50dB, -10℃ low-temperature startup
- High: Single unit cooling capacity40kW, power12kW, AC380V, R410A, dual redundant, IP67, noise ≤45dB, -25℃ wide-temperature startup
6.2.2 Electric Heating Tube
- Low: 3kW, AC220V, stainless steel, insulation resistance≥5MΩ, dry-burning prevention
- Medium: 8kW, AC380V, SUS316 stainless steel, insulation resistance≥10MΩ, dry-burning & overheat protection
- High: 20kW, AC380V, SUS316L stainless steel, insulation resistance≥15MΩ, dry-burning/overheat/constant temperature control
6.3 Humidification & Dehumidification Component Parameters
6.3.1 Electrode Humidifier
- Low: 0.5kg/h humidification, 0.8kW, AC220V, water shortage protection
- Medium: 2kg/h humidification, 1.5kW, AC220V, water shortage/humidity excess protection + automatic cleaning
- High: 5kg/h humidification, 3kW, AC220V, water shortage/humidity excess/scale protection + automatic cleaning + remote monitoring
6.3.2 Refrigeration Dehumidification Module
- Low: 10L/d dehumidification, 0.6kW, AC220V, operating temp10-35℃, automatic defrosting
- Medium: 30L/d dehumidification, 1.2kW, AC220V, operating temp5-40℃, intelligent defrost & humidity control
- High: 50L/d dehumidification, 2kW, AC220V, operating temp -5~50℃, intelligent defrost & redundant backup
6.4 Ventilation Component Parameters
- Explosion-proof Axial Fan: Low air volume300m³/h, 0.15kW, IP54; Medium air volume500m³/h, 0.3kW, IP65; High air volume800m³/h, 0.5kW, IP67; All ExdⅡBT4 explosion-proof grade
- Electric Air Damper: Low caliber300mm, 0.1kW; Medium caliber500mm, 0.2kW; High caliber800mm, 0.3kW; Support switch/regulating type with tight sealing
6.5 Intelligent Monitoring Component Parameters
6.5.1 Temperature & Humidity Sensor
- Low: Temp ±1℃, Humidity ±5%RH, DC24V, IP54
- Medium: Temp ±0.5℃, Humidity ±3%RH, DC24V, IP65 high precision
- High: Temp ±0.2℃, Humidity ±1%RH, DC24V, IP67 anti-interference ultra-precision
6.5.2 PLC Controller
- Low: 8DI/6DO, DC24V, RS485, 7-inch touch screen
- Medium:16DI/12DO, DC24V, RS485/CAN,10-inch touch screen, intelligent linkage programming
- High:32DI/24DO, DC24V, RS485/CAN/Ethernet,15-inch touch screen, dual redundant cloud docking
6.6 Power Distribution Component Parameters
- UPS Power Supply: Low 1kVA/0.8kW, 30min backup; Medium3kVA/2.4kW,60min backup; High10kVA/8kW,120min backup; AC380V input, AC220V output
- Air Switch & Residual Current Protector: Low32A, IP54; Medium63A, IP65; High100A, IP67; Equipped with short-circuit, overload & leakage protection
- Surge Arrester: Low40kA Class III protection; Medium60kA Class IV protection; High80kA Class V protection; Protection voltage ≤1.5kV/1.2kV/1.0kV respectively
6.7 Fire Protection Component Parameters
- Heptafluoropropane Fire Extinguishing Device: Low4kg, 1.2MPa startup pressure; Medium8kg,1.5MPa startup pressure; High16kg,1.8MPa startup pressure; Auto/manual startup, residue-free eco agent
- Sensors: Low smoke sensor single photoelectric, combustible gas sensor single gas detection; Medium composite smoke sensor, multi-gas detector; High triple composite smoke sensor, full-spectrum gas detector; All DC24V with linkage alarm output
7. Product Application Scope
7.1 Core Application: Energy Storage Field
- Grid Energy Storage: Grid peak shaving, frequency regulation, peak load shifting and backup power, compatible with 100-5000kWh capacity to stabilize grid operation
- Industrial & Commercial Energy Storage: Factories, industrial parks, office buildings, shopping malls for peak-valley tariff arbitrage and emergency backup power, compatible with 500-2000kWh capacity
- New Energy Supporting Storage: PV power stations and wind farms to smooth output fluctuation, improve grid connection stability and extend power generation duration, compatible with 100-5000kWh capacity
- Emergency Energy Storage: Emergency power vehicles, communication base station backup, independent power supply for remote areas and disaster relief energy storage, compatible with 100-1000kWh capacity
- Distributed Energy Storage: Household energy storage, community energy storage and microgrid energy storage, compatible with 100-500kWh capacity
7.2 Industrial Precision Control Field
- Storage & transportation of precision equipment: Precision instruments, semiconductor equipment, optical equipment and medical devices sensitive to temperature & humidity, preventing dampness, deformation and damage
- Electronic workshops & laboratories: Electronic component production workshops, constant temperature labs and testing labs to maintain stable ambient conditions and guarantee production/test precision
- Chemical & new material industry: Storage of chemical raw materials, new materials and reagents to avoid deterioration, volatilization and chemical reactions for safety
7.3 Medical & Pharmaceutical Field
- Vaccine & pharmaceutical storage/transportation: Vaccines, biological agents and cold-chain pharmaceuticals to maintain efficacy and avoid failure
- Medical equipment storage: Surgical equipment, emergency devices and precision medical instruments with dustproof, moisture-proof and anti-corrosion protection
7.4 Other Special Fields
- Cultural relic & art storage: Museum cultural relics, calligraphy and sculptures to prevent mildew, insect damage and aging
- Food cold chain: High-end ingredients, fresh produce and red wine for constant temperature preservation and extended shelf life
- Outdoor special scenarios: Equipment protection and energy storage deployment in harsh environments including coastal saline-alkali land, deserts and frigid regions
8. Product Advantages
8.1 Core Functional Features
- Ultra-Precise Temperature & Humidity Regulation: Self-developed KITOZER temperature control algorithm, accuracy up to ±0.2℃/±1%RH (high configuration), wide operating range -40℃~+80℃ to cover all energy storage scenarios
- High Energy Efficiency: Eco-friendly R410A/R407C refrigerant, high-efficiency compressors and variable frequency intelligent control, energy saving rate 30%-50% vs traditional equipment; thick insulation reduces cold & heat loss
- Multi-Layer Safety Protection: IP54/IP65/IP67 dustproof, waterproof, explosion-proof and anti-corrosion grades; fire linkage + combustible gas monitoring + overheat protection to eliminate thermal runaway risks; dual redundant design for high configuration to ensure uninterrupted operation
- Intelligent Remote O&M: PLC automatic control + cloud monitoring platform, real-time data collection, remote control, abnormal alarm and data analysis; mobile APP & PC multi-terminal management to cut operation costs
- Modular Integrated Design: Standard ISO container frames in 20ft/40ft sizes, prefabricated in factory, on-site installation & commissioning completed within 1-3 days; flexible relocation and capacity expansion for variable energy storage demands
- Long Service Life & Stability: High-grade stainless steel/weather-resistant steel with anti-corrosion coating, core components from top brands, service life 15-25 years; stable operation under -40℃~+80℃ extreme temperatures, anti-vibration & impact resistant
8.2 Customization Service Capacity
- Size Customization: Non-standard sizes (10ft/30ft/custom length & height) available based on energy storage capacity and site conditions
- Function Customization: Adjustable cooling/heating/humidification/dehumidification power, customized anti-explosion, anti-corrosion, flame retardant and anti-salt spray protection; integrated BMS, PCS, inverters and charging piles
- Interface Customization: Communication ports (RS485/CAN/Ethernet) compatible with all mainstream battery, BMS and PCS brands; multi-power input interfaces for mains, PV, wind turbines and generators
- Layout Customization: Custom internal battery racks, cable trays, maintenance channels, heat dissipation air ducts and drainage systems
8.3 OEM & ODM Confidential Service
- OEM/ODM Processing: Support customer brand labeling, complete technical scheme, manufacturing, quality inspection and after-sales service; customized production per customer drawings and technical specifications
- Confidentiality Agreement: Sign non-disclosure agreements to fully protect client technical drawings, parameters and order information; full confidentiality during production to avoid technical leakage
8.4 Spot Supply & Fast Delivery
- Standard Models In Stock: Regular 20ft/40ft standard & high cube low/medium configurations ready for shipment, delivery within 7-15 days upon order confirmation
- Rush Order Priority: Urgent orders scheduled for priority production, fastest delivery within 3-7 days; nationwide warehouses for nearby shipment to shorten logistics cycle
8.5 Comprehensive Technical Parameter Advantages
- Ultra-Wide Temperature & Humidity Adaptation: Temperature -40℃~+80℃, humidity10-90%RH to satisfy energy storage, industrial and medical scenarios
- Long-Term Stable Precision: Max temperature accuracy ±0.2℃, humidity ±1%RH with zero long-term drift to guarantee battery operation efficiency
- Top-Tier Protection Rating: IP67 maximum grade for stable long-term operation under heavy rain, temporary immersion, salt spray and desert environments
- Heavy-Duty Load Design: Max floor load capacity 10t/㎡ to hold large-capacity battery packs safely
- Low Noise Operation: Optimized mute design for core components, operating noise controlled at 45-55dB, suitable for residential and office surrounding deployment
9. Tender Control Parameters (Asterisk Marked Mandatory Index)
9.1 Container Tender Parameters
*1. Container Sizes: Three standard specifications (20ft Standard,20ft High Cube,40ft High Cube) with non-standard customization available *2. Material Standard: Outer wall weather-resistant steel/galvanized steel with nano coating/SUS316 stainless steel; inner wall SUS304/SUS316 stainless steel; PU insulation thickness ≥50mm *3. Protection Rating: ≥IP54(Low), ≥IP65(Medium), ≥IP67(High), dustproof, waterproof, explosion-proof & anti-corrosion *4. Operating Temperature Range: -10℃~+50℃(Low), -25℃~+60℃(Medium), -40℃~+80℃(High) *5. Operating Humidity Range: 30-70%RH(Low), 20-80%RH(Medium),10-90%RH(High) *6. Load Capacity: Floor load ≥5t/㎡, top load ≥2t/㎡ *7. Flame Retardant Grade: GB8624-2012 Class B1 hardly flammable
9.2 Temperature Control Component Tender Parameters
*1. Compressor: Scroll type, cooling capacity ≥5kW(Low),≥15kW(Medium),≥40kW(High), eco refrigerant, protection rating ≥IP54 *2. Heating Tube: Power ≥3kW(Low),≥8kW(Medium),≥20kW(High), SUS316/SUS316L stainless steel with dry-burning & overheat protection *3. Humidifier: Humidification capacity ≥0.5kg/h(Low),≥2kg/h(Medium),≥5kg/h(High), water shortage & humidity excess protection *4. Dehumidification Module: Dehumidification capacity ≥10L/d(Low),≥30L/d(Medium),≥50L/d(High), automatic defrosting function
9.3 Intelligent Monitoring Tender Parameters
*1. Temperature & Humidity Sensor: Temp accuracy ≤±1℃(Low),≤±0.5℃(Medium),≤±0.2℃(High); Humidity accuracy ≤±5%RH(Low),≤±3%RH(Medium),≤±1%RH(High) *2. PLC Controller: ≥8DI/6DO(Low),≥16DI/12DO(Medium),≥32DI/24DO(High), support RS485/CAN/Ethernet communication *3. Full Monitoring Function: Real-time collection of temperature, humidity, smoke, combustible gas, door magnetic, voltage & current data with abnormal alarm output
9.4 Power Distribution & Fire Protection Tender Parameters
*1. UPS Power Supply: Capacity ≥1kVA(Low),≥3kVA(Medium),≥10kVA(High), backup duration ≥30min *2. Surge Arrester: Discharge capacity ≥40kA(Low),≥60kA(Medium),≥80kA(High), Class III or higher lightning protection *3. Fire Extinguishing Device: Heptafluoropropane gas suppression, 5.8% extinguishing concentration, auto & manual startup, residue-free eco agent
9.5 Performance & After-Sales Tender Parameters
*1. Energy Saving Efficiency: ≥30% energy saving compared with traditional equipment *2. Service Life: ≥15 years(Low),≥20 years(Medium),≥25 years(High) *3. On-Site Deployment Cycle: ≤3 days for installation & commissioning *4. Quality Warranty: Whole machine ≥1 year, core components ≥3 years *5. Operation & Maintenance Service: 7×24h remote O&M + on-site service, response time ≤2 hours
10. Complete Product Solutions
10.1 Small Distributed Energy Storage Solution (Low Configuration,20ft Standard,100-500kWh)
- Scenarios: Household energy storage, community energy storage, microgrid and independent power supply for remote areas
- Core Configuration: 20ft standard IP54 container, 5kW cooling compressor,3kW electric heating,0.5kg/h humidifier,10L/d dehumidifier, basic PLC monitoring,1kVA UPS,4kg heptafluoropropane fire suppression
- Solution Advantages: Compact size, flexible deployment and low cost with high cost performance; meets basic constant temperature & humidity demands to stabilize small energy storage systems; compatible with off-grid & grid-connected operation for PV/wind matching
- Implementation Period: Site leveling → Container positioning → Equipment installation → Wiring connection → Commissioning & operation → Acceptance delivery, completed within 1-2 days
10.2 Industrial & Commercial Energy Storage Solution (Medium Configuration,20ft High Cube,500-2000kWh)
- Scenarios: Factories, industrial parks, office buildings and shopping malls for peak-valley tariff arbitrage and emergency backup power
- Core Configuration: 20ft high cube IP65 container,15kW cooling compressor,8kW electric heating,2kg/h humidifier,30L/d dehumidifier, intelligent linkage PLC,3kVA UPS,8kg heptafluoropropane fire suppression, remote monitoring module
- Solution Advantages: Spacious internal layout, high temperature control precision and upgraded safety protection; intelligent linkage matching industrial & commercial peak power demands; remote O&M reduces labor costs; waterproof & anti-corrosion for open-air outdoor deployment
- Implementation Period: Site planning → Foundation construction → Container hoisting → Equipment integration → Circuit commissioning → Fire inspection → Trial operation → Delivery training, completed within 2-3 days
10.3 Large Energy Storage Power Station Solution (High Configuration,40ft High Cube,2000-5000kWh)
- Scenarios: Grid peak shaving & frequency regulation, large-scale PV/wind supporting energy storage, grid backup power and emergency storage power stations
- Core Configuration: 40ft high cube IP67 container, dual 40kW cooling compressors,20kW electric heating,5kg/h humidifier,50L/d dehumidifier, dual redundant PLC,10kVA UPS,16kg heptafluoropropane fire suppression, cloud O&M platform, shock-absorbing base
- Solution Advantages: Large energy storage capacity, full redundant design and extreme temperature adaptability; ultra-precise temperature control to maximize battery efficiency & service life; cloud intelligent O&M with real-time data analysis and fault early warning; top-tier protection for coastal, saline-alkali and desert harsh environments
- Implementation Period: Project design → Foundation treatment → Cluster container deployment → Equipment integration → System joint commissioning → Fire acceptance → Grid connection debugging → Trial operation → O&M delivery, completed within 3-5 days
10.4 Extreme Environment Energy Storage Custom Solution (High Configuration Custom,IP67 Enhanced Anti-Corrosion)
- Scenarios: Coastal high salt spray zones, saline-alkali land, high-temperature arid deserts, -40℃ frigid regions and heavy rain areas
- Core Configuration: SUS316 stainless steel container, IP67 rating, anti-salt spray coating, wide-range temperature control (-40℃~+80℃), full redundant system, anti-vibration design and anti-corrosion power distribution components
- Solution Advantages: Super anti-corrosion & anti-salt spray aging resistance; stable operation under extreme high/low temperatures; redundant design eliminates single-point failure; heavy load anti-vibration structure for long-term reliable harsh environment operation
10.5 Precision Energy Storage Laboratory Solution (Ultra-High Precision Custom)
- Scenarios: Energy storage battery R&D labs, BMS testing labs, energy storage system inspection labs and precision instrument storage
- Core Configuration: Ultra-precise constant temperature & humidity container (±0.2℃/±1%RH), clean ventilation, anti-static design, high-precision sensors, data acquisition & analysis system, explosion-proof anti-corrosion assembly
- Solution Advantages: Ultra-precise ambient control for accurate repeatable experimental data; clean anti-static protection for precision R&D equipment; full data traceability; comprehensive safety protection eliminating lab risks
11. Product Application Cases
11.1 Grid Energy Storage Case: Guangdong Grid Peak Shaving Power Station (40ft High Configuration,5000kWh)
- Project Background: Large grid peak-valley difference requiring energy storage for peak shaving & frequency regulation to stabilize power grid
- Configuration Scheme: KITOZER 40ft high cube IP67 constant temperature & humidity container, dual 40kW compressors,20kW heating tube,5kg/h humidifier,50L/d dehumidifier, dual redundant PLC and cloud O&M platform
- Operation Effect: Stable internal environment at 25℃±0.2℃,50%RH±1%RH; Battery operation efficiency increased by 15%, service life extended by 20%; Remote fault response ≤1 hour, annual O&M cost reduced by 40%
11.2 Industrial & Commercial Energy Storage Case: Zhejiang Industrial Park Energy Storage Project (20ft Medium Configuration,1000kWh)
- Project Background: Large peak-valley electricity price gap for tariff arbitrage and factory emergency backup power demand
- Configuration Scheme: KITOZER 20ft high cube IP65 container,15kW cooling compressor,8kW heating tube,2kg/h humidifier,30L/d dehumidifier, intelligent linkage PLC and remote monitoring module
- Operation Effect: Stable internal temperature 22-28℃±0.5℃, humidity40-60%RH±3%RH; Annual electricity cost saving of about 800,000 RMB via peak-valley arbitrage; Backup power protects core equipment against power outages and reduces economic losses
11.3 New Energy Supporting Case: Inner Mongolia Wind Farm Energy Storage Project (20ft Low+Medium Configuration,800kWh)
- Project Background: Unstable wind power output requires energy storage to smooth fluctuation and improve grid connection performance
- Configuration Scheme: KITOZER 20ft standard IP54 container (400kWh) + 20ft high cube IP65 container (400kWh), basic & intelligent temperature control systems adapted to extreme cold & hot climate
- Operation Effect: Stable temperature & humidity control under -30℃~+40℃ ambient temperature; Wind farm grid connection stability improved by 30%, wind curtailment rate reduced by 25%; Cumulative fault-free operation over 8000 hours
11.4 Extreme Environment Case: Hainan Coastal Energy Storage Project (40ft High Configuration,3000kWh)
- Project Background: High salt spray & high humidity coastal environment requiring fully anti-corrosion moisture-proof energy storage container
- Configuration Scheme: KITOZER 40ft high cube IP67 SUS316 stainless steel container, anti-salt spray coating, full anti-corrosion power distribution components and wide-range temperature control system
- Operation Effect: Zero rust & corrosion on container shell under long-term high salt spray & humidity; Internal humidity stably maintained at 50%RH±1%RH to eliminate condensation; No damp damage to energy storage equipment with consistent reliable operation
11.5 Precision Laboratory Case: Jiangsu Energy Storage R&D Lab (20ft Ultra-High Precision,500kWh)
- Project Background: Energy storage battery R&D demands ultra-stable constant temperature & humidity environment for accurate experimental data
- Configuration Scheme: KITOZER 20ft high cube ultra-precise constant temperature & humidity container, ±0.2℃ temperature & ±1%RH humidity accuracy, clean ventilation and anti-static design
- Operation Effect: Stable lab environment at 25℃±0.2℃,50%RH±1%RH; Experimental data accuracy improved by 20% with strong repeatability; Clean anti-static protection safeguards precision R&D instruments
12. Product Faults & Maintenance Guide
12.1 Common Faults, Troubleshooting & Solutions
12.1.1 Abnormal Temperature (Too High/Too Low)
- Fault Phenomenon: Internal temperature exceeds set upper/lower limit
- Root Causes: Compressor failure, refrigerant leakage, broken heating tube, faulty sensor, blocked ventilation, damaged insulation layer
- Troubleshooting Steps:
- Inspect compressor operation for abnormal noise & overheating; replace faulty compressor
- Test refrigerant pressure; replenish refrigerant and repair leakage points if leakage exists
- Check heating tube continuity; replace damaged heating tube
- Calibrate temperature sensor; replace failed sensor
- Clear debris from air vents to guarantee smooth ventilation; repair broken insulation layer
12.1.2 Abnormal Humidity (Too High/Too Low)
- Fault Phenomenon: Internal humidity out of range, causing condensation or excessive dryness
- Root Causes: Malfunctioned humidifier, damaged dehumidification module, faulty humidity sensor, mismatched ventilation volume, loose door sealing
- Troubleshooting Steps:
- Check humidifier water level & electrodes; repair or replace faulty humidifier
- Inspect dehumidifier compressor & evaporator; replace damaged dehumidification module
- Calibrate humidity sensor; replace malfunctioned sensor
- Adjust ventilation air volume; replace aging door sealing strips & seal gaps
12.1.3 System Alarm (Smoke/Combustible Gas/Overload)
- Fault Phenomenon: Sound-light alarm activated with corresponding fault indicator lit
- Root Causes: Smoke concentration exceeding threshold, combustible gas leakage, circuit overload/short-circuit, sensor false alarm
- Troubleshooting Steps:
- Smoke Alarm: Cut off power supply immediately, eliminate fire source, clear smoke and reset alarm
- Combustible Gas Alarm: Activate full ventilation, locate & repair leakage points before reset
- Overload/Short-Circuit Alarm: Inspect circuit & equipment, replace damaged air switches/residual current protectors after fault removal
- False Sensor Alarm: Calibrate or replace faulty sensor
12.1.4 Failed Remote Monitoring
- Fault Phenomenon: Mobile APP/PC terminal cannot view data or send remote control commands
- Root Causes: Network disconnection, communication module failure, PLC crash, cloud platform maintenance
- Troubleshooting Steps:
- Check wired/wireless network connection; restart router & switch
- Reboot PLC controller and communication module; replace damaged module if failure persists
- Contact cloud platform customer service to confirm platform operation status
12.2 Periodic Daily & Scheduled Maintenance
12.2.1 Daily Inspection
- Check real-time internal temperature & humidity data to confirm within set range
- Observe equipment running status for abnormal noise, odor and overheating
- Inspect door sealing strips for breakage & air leakage
- Clear dust & debris from air vents and heat dissipation fins
12.2.2 Weekly Maintenance
- Calibrate temperature & humidity sensors to guarantee data accuracy
- Inspect wiring terminals of compressors, fans, heating tubes and humidifiers for looseness & oxidation
- Clean internal container space, wipe inner walls and floor to prevent dust accumulation & mildew
- Test fire alarm and fire suppression devices to ensure normal operation
12.2.3 Monthly Maintenance
- Test refrigerant pressure; replenish refrigerant or repair leakage if insufficient
- Clean evaporator & condenser fins to remove oil stain and dust for improved heat exchange efficiency
- Test UPS power supply, surge arrester and air switches; simulate emergency power supply function
- Inspect container structure for deformation & rust; touch up anti-corrosion paint timely
12.2.4 Annual Overhaul
- Full calibration of all sensors and controllers; upgrade system program version
- Replace aging sealing strips, cables and filter elements
- Lubricate moving parts including compressors and fans
- Complete inspection of fire protection and power distribution systems to eliminate potential safety hazards
12.3 Maintenance Precautions
- Cut off total power supply and hang warning signs before any maintenance operation to avoid electric shock accidents
- Refrigerant-related operations must be completed by certified professionals to prevent leakage and frostbite injuries
- Fire suppression equipment maintenance shall comply with national fire protection codes; unauthorized disassembly & modification prohibited
- Record all maintenance work in detail for fault tracing and analysis
- Increase maintenance frequency after extreme weather (heavy rain, typhoon, extreme cold) and inspect equipment integrity comprehensively
13. Factory Strength & After-Sales Service System
13.1 Factory Production Capacity
- Production Scale: KITOZER owns two major production bases (Guangzhou, Guangdong & Suzhou, Jiangsu), total floor area 50,000㎡ with 30,000㎡ standardized workshops, annual output capacity of 10,000 sets of constant temperature & humidity containers to fulfill global orders
- R&D Team: 50 professional R&D engineers including 15 senior engineers dedicated to temperature control and energy storage protection technology; 20 invention patents and 50 utility model patents with fully self-developed core technology for continuous iteration & upgrade
- Production Equipment: Imported CNC cutting machines, bending machines, welding robots, automatic spraying lines and assembly pipelines with 80% automation rate; Core components (compressors, sensors, PLC) sourced from top international brands with strict quality control
- Quality Inspection System: Full-process quality management covering raw material procurement, production and finished product testing; Every unit undergoes 72-hour continuous operation test, temperature & humidity precision test, protection rating test and fire linkage test before delivery to guarantee 100% qualified rate
- Supply Chain Advantages: Long-term strategic cooperation with global top suppliers for stable core component supply; Large-volume centralized procurement reduces overall cost for competitive product pricing
13.2 After-Sales Service System
13.2.1 Warranty Commitment
- Whole Machine Warranty: 1-year free warranty for all KITOZER constant temperature & humidity containers; free repair & component replacement for non-human damage within warranty period
- Core Component Warranty: 3-year warranty for compressors, PLC controllers and sensors with lifetime maintenance support
- Extended Warranty: Paid extended warranty service available up to 2-5 years for comprehensive protection upon customer demand
13.2.2 Global Service Network
- Domestic Service: Service outlets covering all 31 provinces & municipalities in China, 24-hour service hotline with response time ≤2 hours, on-site service within 4 hours (excluding remote mountainous areas)
- Overseas Service: Authorized service centers established in Southeast Asia, Europe and America to provide localized after-sales support for overseas projects
13.2.3 Full-Cycle Service Content
- Pre-Sales Service: Free site survey, customized scheme design and technical consultation; Product samples, parameter documents and project case provision; personalized tailored solution development
- In-Sales Service: Dedicated technical engineers track production, installation and commissioning progress; Free on-site installation guidance and operator training; Assist customers with project acceptance and grid connection debugging
- After-Sales Service: 7×24h remote O&M with real-time equipment monitoring and fault early warning; Free software upgrade and technical update; Regular return visits and periodic on-site maintenance to guarantee long-term stable equipment operation; Lifetime free technical consultation for all clients
13.2.4 Emergency Fault Response
- Dedicated emergency repair team prioritizes handling sudden equipment failures; Standby spare units provided to minimize customer economic losses; Major faults resolved within 24 hours to restore system operation rapidly
14. Conclusion
With five core strengths including ultra-precise temperature control, high energy efficiency, comprehensive safety reliability, intelligent O&M and flexible customization, KITOZER constant temperature & humidity containers for energy storage fully cover grid energy storage, industrial & commercial energy storage, new energy supporting storage and emergency energy storage scenarios. It delivers a safe operating space with constant temperature, constant humidity, dustproof, explosion-proof and anti-corrosion performance for energy storage systems, boosting high-quality development of the energy storage industry.
Moving forward, KITOZER will continue deepening the energy storage protection sector, increase R&D investment, optimize product performance, upgrade technical standards and improve service systems. We will supply premium products and professional services to meet diversified global customer demands, and cooperate with partners to create a new future for the energy storage industry.
15. SEO Optimization (Keywords, Tags & Anchor Texts)
15.1 Core Primary Keywords
- Constant Temperature & Humidity Container
- Energy Storage Constant Temperature & Humidity Container
- Energy Storage Container
- KITOZER Constant Temperature & Humidity Container
15.2 High Conversion Long-Tail Keywords
- Grid Energy Storage Constant Temperature & Humidity Container
- Industrial & Commercial Energy Storage Constant Temperature & Humidity Solution
- 20ft/40ft Energy Storage Constant Temperature & Humidity Container
- High Precision Energy Storage Constant Temperature & Humidity Container
- Extreme Environment Energy Storage Protection Container
- Energy Storage Battery Constant Temperature & Humidity Box
15.3 Industry Traffic Keywords
- Energy Storage Container
- Temperature Control Container
- Energy Storage Equipment Protection Box
- Constant Temperature & Humidity Equipment
- Energy Storage System Solution
- New Energy Storage Equipment
15.4 Brand Exclusive Keywords
- KITOZER Energy Storage Container
- KITOZER Temperature Control Equipment
- KITOZER Constant Temperature & Humidity Solution
- KITOZER Energy Storage Equipment
15.5 Search Drop-Down & Related Search Keywords
- Constant Temperature & Humidity Container Price
- Energy Storage Container Manufacturer
- Constant Temperature & Humidity Container Application Scenarios
- Energy Storage Container Configuration List
- Constant Temperature & Humidity Container Maintenance Guide
- Recommended Energy Storage Container Brands
快速
图像生成
帮我写作
翻译
PPT 生成
视频生成
深入研究
AI 播客
更多