This manual is the official installation, wiring, and commissioning guide for the LA-AR series convergence layer routers independently developed and manufactured by Guangdong Lain Intelligent System Development Co., Ltd. It applies to all models of the LA-AR1000 box-type access convergence series, LA-AR3000 mid-to-high-end chassis-type convergence series, and LA-AR7000 high-end carrier-grade convergence series. The document covers the full product lifecycle technical essentials, providing comprehensive and detailed instructions on product awareness, deployment installation, cable connection, system commissioning, routine operation and maintenance, fault troubleshooting, and project acceptance. It is designed to provide network engineers, operations personnel, and project implementation staff with standardized, actionable operating guidelines to ensure standardized equipment deployment, stable operation, and compliant performance.
This manual is compiled based on current mainstream network technology architectures and industry standards, and complies with national and industry standards including YD/T 1097-2019 *”Router Equipment Technical Requirements — High-End Routers”* and GB/T 30094-2013 *”Technical Specification for Industrial Ethernet Switches”*. All operational procedures have been validated through laboratory testing and field project verification. Readers may strictly follow the procedures; for customized models or special scenario deployments, please contact our technical support team for a dedicated solution.
Please read this manual carefully before equipment installation and commissioning, and strictly comply with operating specifications and safety precautions to avoid equipment damage, service interruption, or personal safety hazards caused by improper operation. It is recommended that the entire process of equipment unpacking, installation, wiring, commissioning, and acceptance be performed by professionally qualified network engineers.
Chapter 1 Product Introduction
1.1 Definition of Convergence Layer Router and Network Positioning
The convergence layer router is a critical network node device in the three-tier network architecture (access layer – convergence layer – core layer) that serves as the link between the upper and lower layers. It is deployed between the access layer and the core layer and undertakes four core functions: access traffic aggregation, subnet route forwarding, network policy enforcement, and WAN interconnection. Unlike access layer devices that focus on terminal access and core layer devices that focus on high-speed forwarding, the convergence layer router is the network’s “dispatch center.” It must not only achieve bandwidth convergence of multiple access nodes but also handle complex service processing such as inter-VLAN routing, access control, QoS scheduling, and VPN termination, while interfacing upward with core layer devices to ensure efficient, secure, and orderly transmission of network-wide traffic.
In traditional campus network architectures, convergence layer routers are typically deployed by building or zone, with each convergence device connecting dozens of access layer switches and covering hundreds to thousands of terminal nodes. In carrier metropolitan area networks, convergence layer routers are deployed at POP points, receiving access network traffic from the service area and forwarding it to core routing nodes. In industry private networks for government, finance, energy, and other sectors, convergence layer routers simultaneously undertake security functions such as service isolation, encrypted transmission, and boundary protection, serving as core supporting devices in the hierarchical private network architecture.
The Guangdong Lain LA-AR series convergence layer routers are developed based on domestic high-performance network processors and independently controllable network operating systems, covering the full performance range from gigabit access to 100G uplink. They are suitable for all industry scenarios including enterprise, carrier, government, finance, energy, and transportation, and feature core advantages of high reliability, multi-service support, easy operation and maintenance, and strong security. They can fully replace imported equipment at the same level, meeting the network construction requirements of IT innovation (Xinchuang) transformation and digital transformation.
1.2 Development History of Convergence Layer Routers
The technological evolution of convergence layer routers is deeply tied to the upgrade of network service formats, having undergone four generations of technological iteration:
First Generation: Basic Routing Convergence Stage (Before 2000)
Early convergence layer devices focused on simple route forwarding as their core function, supporting only basic protocols such as static routing and RIP. Interfaces were primarily 10M/100M Ethernet ports and WAN interfaces such as E1 and POS. Performance was low, service capabilities were limited, and the main purpose was to solve multi-subnet interconnection and WAN access issues. Device form factors were predominantly fixed-interface box-type structures.
Second Generation: Multi-Service Convergence Stage (2000-2010)
With the proliferation of enterprise informatization and the internet, convergence layer routers began integrating service functions such as firewall, NAT, VPN, and QoS, supporting dynamic routing protocols including OSPF and BGP. Interfaces were upgraded to gigabit Ethernet and 155M/622M POS interfaces. Modular chassis-type devices gradually became the mainstream for mid-to-high-end products, allowing flexible function expansion through service line cards to meet scenarios such as enterprise branch interconnection and leased line access.
Third Generation: High-Performance Cloudification Stage (2010-2020)
The explosive growth of cloud computing, big data, and mobile office drove exponential growth in network traffic. Convergence layer routers evolved toward high performance and virtualization, with forwarding performance increasing from hundreds of Gbps to Tbps levels. 10GE/40GE interfaces became standard, supporting cloud network technologies such as IRF stacking, MDC virtual devices, and VXLAN. The control plane and forwarding plane adopted hardware separation, achieving carrier-grade reliability and supporting fine-grained scheduling and elastic expansion of cloud service traffic.
Fourth Generation: Intelligent and Secure Stage (2020 to Present)
The IT innovation industry upgrade and network security requirements have driven convergence layer routers into the era of independent controllability and intelligent operations. Domestic CPUs, switching chips, and operating systems are now comprehensively applied, with hardware-level national cryptography encryption and built-in security becoming standard. Concurrently, new technologies such as AI operations, SRv6, and Flex-E slicing have been introduced, enabling intelligent prediction of network faults and flexible scheduling of service bandwidth. Device operations are transitioning from manual CLI configuration to visualized, automated, and intelligent management.
The LA-AR series convergence layer routers belong to the fourth-generation intelligent and secure products, fully adapted to digital transformation and IT innovation construction requirements, achieving domestic leading levels in hardware independence, service richness, reliability, and intelligent operations.
1.3 Core Product Value
1.3.1 Network Architecture Value
Traffic Hub Connecting Upper and Lower Layers: Achieves convergence and forwarding of access layer traffic, reducing access pressure on core layer devices, simplifying the core layer architecture, and enhancing overall network scalability. Through hierarchical architecture, fault domains are isolated to local areas—a single convergence device failure does not affect the entire network, improving overall network reliability.
Edge Node for Policy Enforcement: Offloads policies such as access control, QoS scheduling, and security protection to the convergence layer for execution, avoiding excessive core layer device performance consumption on service policy processing and ensuring core forwarding efficiency. Simultaneously, it enables zone-based and service-based fine-grained management at convergence nodes, adapting to differentiated network requirements of different departments and services.
WAN Access Termination: Serves as the WAN egress node for campuses and branches, terminating multiple WAN links including leased lines, 5G, and the internet, implementing VPN encryption, route optimization, and link load balancing to ensure stable cross-regional service interconnection.
1.3.2 Service Support Value
Multi-Service Converged Carriage: A single device can simultaneously carry multiple service types including data, voice, video, and IoT. Through HQoS technology, service bandwidth assurance and priority scheduling are achieved, ensuring low latency and zero packet loss for critical services such as video conferencing and industrial control.
Smooth Expansion Protecting Investment: Modular devices support on-demand expansion of service line cards and interface modules; box-type devices support stacking expansion. Systems can be gradually upgraded as services grow without requiring complete unit replacement, reducing network construction and upgrade costs.
Security Compliance Assurance: Built-in security functions including firewall, intrusion prevention, access control, and log auditing, with support for national cryptography algorithm encryption, meeting the requirements of Classified Protection 2.0 and industry private network security specifications, providing end-to-end security protection for service data.
1.3.3 Operation and Maintenance Management Value
Unified Management Simplifying Operations: Supports multiple management methods including Web network management, CLI command line, SNMP, and cloud management platforms, enabling batch configuration, status monitoring, and alarm reporting to reduce operational complexity. Supports zero-touch provisioning—the device automatically obtains configuration after power-on, significantly shortening project deployment cycles.
High Reliability Reducing Downtime: Critical components adopt redundant design, supporting hot-swapping and seamless switching, with whole-machine availability reaching 99.999%. Comprehensive fault detection and self-healing mechanisms enable rapid fault location and isolation, reducing service interruption time.
Intelligent Operations Reducing Costs and Increasing Efficiency: Supports Telemetry real-time performance collection and AI fault prediction, enabling early identification of hazards such as port congestion, link degradation, and resource overload. Proactive operations replace reactive troubleshooting, significantly reducing operations labor costs.
1.4 Product Applicability Scope
This series of convergence layer routers is widely applicable to network construction and upgrade in the following scenarios:
- Convergence layer deployment in large and medium-sized enterprise campus networks and multi-branch enterprise interconnection networks
- Carrier metropolitan area network access convergence, 5G bearer network edge convergence, and broadband access network BRAS scenarios
- Government private networks at provincial/municipal/county levels, and convergence nodes in government cloud external connection zones
- Branch network convergence and data center edge convergence for financial institutions including banks, securities, and insurance companies
- Industrial private network convergence in energy and transportation industries including electric power, petroleum, coal, and rail transit
- Network convergence layers for large public venues such as hospitals, universities, campuses, and stadiums
- Data center access convergence and cloud edge node route deployment
Chapter 2 Product Composition
2.1 Hardware System Composition
The LA-AR series convergence layer routers adopt a modular hardware architecture design (box-type devices use integrated modular structures). The hardware system can be divided into six major modules: chassis subsystem, main control and switching subsystem, service processing subsystem, power subsystem, cooling subsystem, and interface subsystem. All modules work cooperatively to implement core functions including data forwarding, service processing, and device management.
2.1.1 Chassis Subsystem
The chassis is the physical carrier of the device, providing mounting slots, physical support, and electromagnetic shielding protection for all functional modules, while integrating the backplane bus to achieve data exchange and power connectivity between modules.
Chassis Material: 1.5mm thickened high-quality cold-rolled steel plate, surface treated with electrostatic powder coating, featuring high strength, corrosion resistance, and anti-electromagnetic interference characteristics. Complies with the GB/T 13926 electromagnetic compatibility standard, meeting industrial-grade environmental electromagnetic protection requirements.
Backplane Design: High-end chassis-type devices adopt a passive backplane design. The backplane integrates high-speed SerDes buses and power buses with no active components, significantly reducing backplane failure probability. Single-slot bandwidth supports 100G/400G, meeting the non-blocking switching requirements of high-speed service line cards.
Slot Layout: Chassis-type device slots are divided into four categories: main control slots, service line card slots, power slots, and fan slots. Slots feature keyed/mistake-proof designs to prevent incorrect module insertion. Slot rails use precision stamping technology to ensure smooth module insertion/removal and reliable contact.
EMC Protection: Conductive foam is installed at chassis seams, filter circuits are provided at interface locations, and the complete unit meets Class B electromagnetic compatibility levels, enabling stable operation in complex electromagnetic environments without generating electromagnetic interference to surrounding electronic equipment.
Structural Design: Standard 19-inch rack-mount structure. Box-type devices cover heights of 1U/2U/3U, and chassis-type devices cover 4U/6U/8U/16U, adaptable to standard server cabinet installation. The chassis is equipped with a removable front panel, balancing dust protection with operational convenience.
2.1.2 Main Control and Switching Subsystem
The main control and switching subsystem is the “brain” of the device, divided into two parts: the control plane and the switching plane. The control plane is responsible for system management, protocol computation, and configuration distribution, while the switching plane is responsible for high-speed cross-board forwarding of data packets. Mid-to-high-end devices adopt a separated architecture of main control and switching fabric boards, while entry-level devices use an integrated main control and switching design.
Main Processing Unit (MPU)
- Core Processor: Equipped with a domestic multi-core high-performance CPU, main frequency ≥2.0GHz, core count ≥16 cores, with a dedicated hardware encryption engine capable of efficiently handling tasks including routing protocol computation, service configuration management, and encryption operations.
- Storage Units: Equipped with DDR4 high-speed memory (8GB minimum for entry-level, 64GB minimum for high-end devices) for system operation, routing table storage, and service table entry caching. Equipped with eMMC flash storage (16GB minimum) for storing system images, configuration files, and log files.
- Management Interfaces: The main control board integrates a Console port, MGMT management Ethernet port, USB port, and SD card slot, supporting local serial port management, remote Web/SSH management, and system file backup and upgrade.
- Reliability Design: Supports dual main control redundancy backup. Active and standby main controls synchronize configuration and status data in real-time through the backplane bus. In the event of active main control failure, the standby main control can perform seamless switchover within 50ms without service interruption. Supports hot-swapping of the main control board, allowing online replacement of a faulty main control without shutdown.
- System Clock: Built-in high-precision clock module supporting 1588v2 PTP precision time protocol and Synchronous Ethernet clock, meeting scenarios with high time synchronization accuracy requirements such as 5G bearer networks and industrial control.
Switch Fabric Unit (SFU)
- Switching Chips: Uses domestic high-performance switching chips based on a CLOS multi-stage switching architecture, achieving non-blocking switching. The whole-machine switching capacity ranges from 320Gbps to 32Tbps, meeting different performance tier requirements.
- Redundancy Design: High-end devices are equipped with N+M redundant switching fabric boards. A single fabric board failure does not affect the entire machine’s forwarding performance. Supports fabric board hot-swapping for online expansion or replacement.
- Load Balancing: Supports packet hash load sharing, distributing traffic evenly across multiple fabric boards to fully utilize switching bandwidth and avoid single fabric board congestion.
2.1.3 Service Processing Subsystem
The service processing subsystem is responsible for deep processing of various network services, including route forwarding, security protection, VPN encryption, and QoS scheduling. It is divided into two categories: integrated service boards and dedicated function boards.
General-Purpose Routing Service Board
As the most basic service line card, it provides Ethernet and WAN interfaces and handles general services including basic route forwarding, ACL access control, QoS scheduling, and NAT address translation. Based on hardware forwarding chips for wire-speed processing, forwarding performance does not degrade when all services are enabled.
Security Service Board
Built-in hardware firewall engine and national cryptography encryption chips, providing security functions including intrusion prevention, virus filtering, IPSec/SSL VPN encryption, and support for national cryptography algorithms SM1/SM2/SM3/SM4. Can serve as a boundary security gateway for private networks.
WAN Interface Board
Provides traditional WAN interfaces including E1, CPOS, POS, and ATM, adapted to legacy link access scenarios such as carrier leased lines and industrial private networks. Supports WAN protocols including PPP, HDLC, and Frame Relay.
Value-Added Service Board
Includes load balancing boards, DPI deep packet inspection boards, video optimization boards, etc. Can be flexibly selected based on service requirements to implement application-layer traffic identification and optimization.
2.1.4 Power Subsystem
The power subsystem provides stable and reliable DC/AC power to the entire machine, adopting modular redundant design and serving as the foundation for stable device operation.
Power Module Types: Supports three types: AC power (100-240V AC, 50/60Hz), DC power (-48V DC), and high-voltage DC power (240V DC), adaptable to different computer room power supply environments. Power module capacity covers 300W-3000W, selected according to device model and configuration.
Redundancy Design: Standard configuration includes 1+1 redundant power supplies. Both power supplies operate simultaneously with load sharing; if one power supply fails, the other can assume full machine load power supply without service interruption. Supports hot-swapping of power modules for online replacement of faulty power modules.
Protection Mechanisms: Built-in multiple protection circuits for overvoltage, undervoltage, overcurrent, overtemperature, and short circuit. In the event of abnormal power supply, the faulty circuit is automatically cut off to avoid damage to other device components. Supports real-time power status monitoring with proactive alarm reporting upon failure.
Energy Efficiency Standards: 80PLUS Platinum certified, conversion efficiency ≥94%. Features intelligent power adjustment that dynamically adjusts output power based on device load, reducing no-load losses and complying with green energy-saving requirements.
2.1.5 Cooling Subsystem
The cooling subsystem ensures stable device operation within the rated temperature range, adopting an intelligent temperature-controlled cooling solution that dynamically adjusts fan speed based on device temperature, balancing cooling efficiency with low noise.
Fan Modules: Uses chassis-type fan assemblies equipped with high-speed ball-bearing fans with a service life of ≥100,000 hours. Supports N+1 redundant design—a single fan failure does not affect the entire machine’s cooling. Supports hot-swapping for online replacement.
Cooling Airflow: Uses a front-intake, rear-exhaust direct airflow channel design with short airflow paths and high cooling efficiency. Critical chips are equipped with independent heat sinks and airflow guides to ensure uniform chip temperatures and avoid localized overheating.
Intelligent Speed Control: The device is equipped with multiple temperature sensors that monitor temperatures of critical areas including chips, interfaces, and power supplies in real-time, automatically adjusting fan speed according to temperature tiers. Low-speed operation under low load reduces noise and energy consumption; automatic speed increase under high load ensures adequate cooling.
Dust Protection Design: The air intake is equipped with a washable dust filter that intercepts airborne dust particles, preventing dust from entering the chassis and causing poor heat dissipation on components. The dust filter can be pulled out directly from the front panel for cleaning without disassembling the machine.
2.1.6 Interface Subsystem
The interface subsystem provides the device’s connection ports to the external network, divided into three categories: service interfaces, management interfaces, and auxiliary interfaces.
Service Interfaces
- Ethernet Copper Ports: 10/100/1000Mbps auto-negotiation RJ45 interfaces, connected using Cat5e or higher twisted pair cables, transmission distance ≤100 meters, used for access layer device interconnection and local service access.
- Ethernet Optical Ports: Includes GE, 10GE, 25GE, 40GE, and 100GE rates, using pluggable optical modules such as SFP/SFP+/QSFP+/QSFP28. Supports single-mode, multi-mode, and different transmission distance optical module options, used for core uplink, inter-device interconnection, and long-distance transmission.
- WAN Interfaces: Interfaces such as E1, CPOS, and POS for traditional leased line access, matching carrier transmission networks.
Management Interfaces
- Console Port: RJ45-type serial port, default baud rate 9600bps, used for device initial configuration and fault emergency management. This is the most basic management channel of the device.
- MGMT Port: 10/100/1000M auto-negotiation Ethernet port, independent of the service forwarding plane, used for remote management via Web network management, SSH, SNMP, etc. Management traffic does not occupy service bandwidth.
Auxiliary Interfaces
- USB Interface: USB 2.0 standard interface for system version upgrades, configuration file import/export, and external storage device log backup.
- Alarm Interface: Dry contact alarm output interface that can interface with computer room power and environment monitoring systems, enabling audible/visual alarm and centralized monitoring of device faults.
2.2 Software System Composition
The LA-AR series convergence layer routers run on Lain’s independently developed LA-OS network operating system, developed based on a modular Linux kernel, featuring high stability, high scalability, and high security. The software system is divided into four layers: system kernel layer, protocol control layer, service function layer, and management and operations layer.
2.2.1 System Kernel Layer
The system kernel layer is the foundation of the software system, providing underlying capabilities including process management, memory management, driver scheduling, and hardware abstraction.
Modular Kernel: Adopts a microkernel architecture where each functional module operates independently; a single module failure does not cause the entire machine to crash. Supports dynamic module loading and unloading, enabling on-demand function enablement to conserve system resources.
Hardware Abstraction Layer (HAL): Shields differences between hardware platforms, eliminating the need for upper-layer software to adapt to specific hardware, achieving unified software versions across hardware platforms and reducing version maintenance costs.
Real-Time Operating System Features: Supports task priority scheduling. Critical protocol processes and forwarding processes have the highest priority, ensuring that the management plane and control plane remain controllable even under high-volume traffic attacks.
Security Hardening: The kernel undergoes security trimming, removing unnecessary system services and ports. Built-in buffer overflow protection and permission control mechanisms reduce the risk of system attacks.
2.2.2 Protocol Control Layer
The protocol control layer is responsible for computation and maintenance of various network protocols, generating key tables including routing tables and forwarding tables and distributing them to the forwarding plane.
Routing Protocol Suite
- Unicast Routing Protocols: Supports mainstream unicast routing protocols including static routing, RIP v1/v2, OSPF v2/v3, IS-IS, and BGP4/BGP4+. Supports routing policies, policy-based routing, and route recursion, meeting route deployment requirements for networks of different scales.
- Multicast Routing Protocols: Supports multicast protocols including IGMP v1/v2/v3, PIM-SM, PIM-DM, MSDP, and MBGP. Supports multicast CAC and multicast QoS, adapted to multicast service scenarios such as IPTV, video conferencing, and live streaming.
- MPLS Protocols: Supports MPLS-related protocols including MPLS LDP, MPLS TE, BGP L3VPN, BGP L2VPN, VPLS, and EVPN, enabling construction of large-scale virtual private networks with multi-service isolated carriage.
Link Protocol Suite
Supports link layer protocols including Ethernet, PPP, HDLC, Frame Relay, and ATM. Supports VLAN extension technologies including 802.1Q VLAN, QinQ, and VLAN Stacking. Supports link reliability protocols including LACP link aggregation and LACP MAD.
Clock Synchronization Protocols
Supports 1588v2 PTP, Synchronous Ethernet, and BITS clock input/output, meeting high-precision time synchronization requirements in power, transportation, and 5G bearer applications.
2.2.3 Service Function Layer
The service function layer provides various network service processing capabilities and serves as the core carrier of multi-service convergence for convergence layer routers.
Security Services: Stateful firewall, ACL access control lists, NAT/NAPT address translation, IPSec VPN, SSL VPN, GRE VPN, L2TP VPN, intrusion prevention, anti-DDoS attack, URL filtering, and national cryptography algorithm support.
QoS Services: Traffic classification, traffic policing, traffic shaping, congestion management, congestion avoidance, HQoS hierarchical QoS, and application-based QoS scheduling. Supports multiple queue scheduling algorithms including SP, WRR, WFQ, and PQ.
Reliability Services: VRRP/VRRP6, BFD fast detection, ETH OAM, IP FRR, LDP FRR, TE FRR, NSR non-stop routing, and ISSU in-service software upgrade.
Value-Added Services: DPI deep packet inspection, application identification, load balancing, video optimization, NAT66, and IPv6 transition technologies (dual stack, tunneling, translation).
2.2.4 Management and Operations Layer
The management and operations layer provides device configuration, monitoring, operations, and troubleshooting management functions, supporting multiple management methods and operations tools.
Configuration Management: Supports CLI command line, Web graphical management, NETCONF/YANG automated configuration, and ZTP zero-touch provisioning. Supports configuration file backup, restoration, comparison, and rollback.
Monitoring and Alarming: Supports SNMP v1/v2c/v3, Telemetry, Syslog, and alarm Traps. Supports real-time monitoring of resources including port status, CPU, memory, temperature, power supply, and fans. Supports threshold alarming and alarm classification.
Diagnosis and Troubleshooting: Supports Ping, Tracert, port mirroring, packet capture, traffic statistics, and fault diagnosis tools. Supports one-click information collection for rapid fault cause identification.
System Maintenance: Supports local/remote system upgrades, patch loading, log management, and user permission management. Supports dual system image backup with automatic rollback to the previous version upon upgrade failure.
Chapter 3 Product Classification
The LA-AR series convergence layer routers can be classified into multiple categories according to product form factor, performance tier, application scenario, and interface type, comprehensively covering network convergence requirements of different scales and industries. Users can flexibly select models based on actual networking scenarios and performance requirements.
3.1 Classification by Product Form Factor
3.1.1 Box-Type Convergence Routers
Box-type convergence routers feature an integrated design of fixed interfaces plus expansion slots, offering high integration, compact size, and flexible deployment. They are suitable for small-to-medium scale network convergence and branch node convergence scenarios.
1U Box-Type Convergence Routers (LA-AR1000 Series)
- 1U device height, standard rack mounting, saving cabinet space;
- Fixed 16-24 gigabit copper ports + 4-8 gigabit/10-gigabit optical ports, equipped with 1-2 expansion slots for flexible expansion of WAN interfaces or security service modules;
- Forwarding performance of 1-10 Mpps, switching capacity of 32-128 Gbps, adapted to convergence layer deployment in small-to-medium enterprises, county/district branches, and small campuses;
- Supports dual power supply redundancy and intelligent fan cooling, with reliability meeting enterprise-grade requirements;
- Representative models: LA-AR1016, LA-AR1024, LA-AR1024X.
2U/3U Box-Type Convergence Routers (LA-AR2000 Series)
- Device height of 2U or 3U, with stronger performance and expansion capability;
- Fixed 24-48 gigabit interfaces + 8-16 10-gigabit optical ports, equipped with 2-4 service expansion slots, supporting multiple board types including security, WAN, and value-added service boards;
- Forwarding performance of 10-50 Mpps, switching capacity of 128-512 Gbps, adapted to scenarios including medium-sized enterprises, municipal branches, and building convergence;
- Supports dual main control and dual power supply redundancy, supports hot-swappable modules, with higher reliability;
- Representative models: LA-AR2048, LA-AR2024X, LA-AR2016H.
3.1.2 Chassis-Type Convergence Routers
Chassis-type convergence routers adopt a fully modular design of chassis plus service line cards, offering strong performance, high expansion capability, and high reliability. They are suitable for scenarios including core convergence in medium-to-large networks, carrier POP point convergence, and industry private network backbone convergence.
Medium-Small Chassis-Type Convergence Routers (LA-AR3000 Series)
- Chassis height of 4U-8U, equipped with 2 main control slots + 4-8 service board slots + 2 power slots;
- Switching capacity of 512G-2Tbps, forwarding performance of 50-200 Mpps, supporting interface configurations primarily with 10-gigabit and 100G uplinks;
- Supports dual main control redundancy, N+1 power redundancy, and hot-swapping of all modules, with carrier-grade reliability design;
- Adapted to scenarios including large enterprise campuses, municipal-level government networks, and MAN edge convergence;
- Representative models: LA-AR3008, LA-AR3016.
Large Chassis-Type Convergence Routers (LA-AR7000 Series)
- Chassis height of 12U-16U, equipped with 2 main control slots + 4 switching fabric board slots + 16-32 service board slots + 4 power slots;
- Switching capacity of 2T-32Tbps, forwarding performance of 200-1200 Mpps, supporting 100G/400G high-speed interfaces for large-capacity traffic convergence requirements;
- Adopts CLOS non-blocking switching architecture with three-plane separation of control, switching, and service. Supports full redundancy of main control, switching fabric boards, power supplies, and fans, with whole-machine availability of 99.999%;
- Adapted to high-end scenarios including provincial government networks, carrier MAN core convergence, and large data center convergence;
- Representative models: LA-AR7016, LA-AR7032.
3.2 Classification by Performance Tier
3.2.1 Entry-Level Convergence Routers
- Performance Range: Switching capacity of 32-128 Gbps, forwarding performance of 1-10 Mpps;
- Interface Specifications: Primarily gigabit interfaces, with 10-gigabit interfaces used for uplink;
- Service Capabilities: Supports basic routing, NAT, VPN, and basic QoS, meeting simple service convergence requirements;
- Applicable Scenarios: Small enterprises, township branches, and building branch convergence, with node count ≤500 terminals;
- Product Advantages: High cost-effectiveness, simple deployment, convenient operation and maintenance, suitable for small-scale networks with limited budgets and single service types.
3.2.2 Mid-to-High-End Convergence Routers
- Performance Range: Switching capacity of 128G-2Tbps, forwarding performance of 10-200 Mpps;
- Interface Specifications: Primarily gigabit access + 10-gigabit uplink, supporting 100G uplink expansion;
- Service Capabilities: Full service feature support including HQoS, firewall, MPLS VPN, multicast, and IPv6, capable of carrying multi-service converged traffic;
- Applicable Scenarios: Medium-sized enterprise campuses, municipal-level industry private networks, and MAN access convergence, with terminal node count of 500-5000;
- Product Advantages: Balanced performance and functionality, strong expandability, high reliability, currently the most widely applied tier in the market.
3.2.3 High-End Carrier-Grade Convergence Routers
- Performance Range: Switching capacity above 2Tbps, forwarding performance above 200 Mpps;
- Interface Specifications: 10G/25G access + 100G/400G uplink, with high-density high-speed interfaces;
- Service Capabilities: Supports carrier-grade features including SRv6, Flex-E, EVPN, large-scale MPLS, and carrier-grade OAM, supporting massive routing table entries;
- Applicable Scenarios: Carrier MANs, provincial-level and above industry private networks, and large data center convergence, with terminal node count above 5000;
- Product Advantages: Carrier-grade reliability, ultra-large capacity, and rich carrier-grade features, meeting high-specification, large-scale network deployment requirements.
3.3 Classification by Application Scenario
3.3.1 Enterprise-Grade Convergence Routers
Designed for enterprise campus and multi-branch interconnection scenarios, focusing on multi-service convergence, VPN interconnection, and security protection capabilities.
- Built-in rich VPN functions supporting multiple VPN technologies including IPSec, SSL, and L2TP, meeting cross-regional branch interconnection needs;
- Integrated security functions including stateful firewall, intrusion prevention, and internet behavior management, replacing independent security devices and simplifying network architecture;
- Supports cloud management platform for unified management and batch configuration of multi-branch devices, reducing multi-branch operations costs;
- Adapted to typical enterprise services including office applications, video conferencing, and cloud access, with fine-grained QoS assurance.
3.3.2 Carrier-Grade Convergence Routers
Designed for carrier MAN, 5G bearer network, and broadband access network scenarios, focusing on large capacity, high reliability, and carrier-grade operations capabilities.
- Supports BRAS broadband remote access function, implementing PPPoE and IPoE user access authentication, accounting, and bandwidth control;
- Supports next-generation bearer network technologies including SRv6, EVPN, and Flex-E, adapted to 5G bearer and cloud-network convergence service requirements;
- Supports carrier-grade OAM and protection switching, achieving 50ms-level fault switchover to meet carrier network availability requirements of 99.999%;
- Supports integration with carrier OSS/BSS systems, implementing full-process automation of resource management, accounting, and operations.
3.3.3 IT Innovation (Xinchuang) Security Convergence Routers
Designed for industries with high requirements for independent controllability and security compliance, such as government, finance, and energy, achieving full-stack domestic independence of hardware and software.
- 100% domestic core components: domestic CPU, domestic switching chips, domestic memory, and domestic storage;
- Equipped with a domestic independently controllable network operating system, certified at Classified Protection 2.0 Level 3 or above, compliant with IT innovation product catalog requirements;
- Built-in national cryptography algorithm hardware engine supporting the full SM1-SM4 national cryptography algorithm suite, including national cryptography VPN and national cryptography authentication;
- Certified by authoritative institutions including the National Secrecy Administration, Ministry of Public Security, and Cryptography Administration, meeting requirements for classified networks and critical information infrastructure construction.
3.3.4 Industrial-Grade Convergence Routers
Designed for industrial scenarios including electric power, transportation, mining, and factories, adapted to harsh industrial environments with industrial-grade reliability.
- Wide Temperature Design: Operating temperature range of -40°C to 75°C, adapted to extreme high and low temperature environments;
- High Protection Rating: Chassis protection rating of IP40 and above, dustproof and moisture-proof, supporting both DIN-rail and rack mounting;
- Industrial-Grade Electromagnetic Compatibility: Meets IEC 61850 and GB/T 17626 industrial EMC standards, resistant to strong electromagnetic interference;
- Industrial Protocol Support: Supports transparent transmission and parsing of industrial protocols including Modbus and IEC 60870-5-104, adapted to industrial control networks.
3.4 Classification by Interface Rate
- Gigabit Convergence Routers: Primarily gigabit Ethernet interfaces with 10-gigabit uplink expansion capability, suitable for small-to-medium networks with low access bandwidth requirements;
- 10-Gigabit Convergence Routers: 10-gigabit interfaces as the primary uplink and interconnection interfaces, with mixed gigabit/10-gigabit access side. This is the current mainstream configuration, suitable for most medium-to-large networks;
- 100G Convergence Routers: 100G interfaces as the core uplink with 10G/25G access side, suitable for high-traffic, high-density high-end convergence scenarios such as data centers and MAN core convergence.
Chapter 4 Product Checklist
4.1 Standard Configuration Checklist
The device ships with the host unit and standard accessories. After unpacking, please verify against the following checklist item by item. If any items are missing, damaged, or do not match the model, please contact our sales or after-sales personnel promptly.
| No. | Item Name | Quantity | Remarks |
|---|---|---|---|
| 1 | Convergence layer router host unit | 1 unit | Corresponds to ordered model, including chassis and default-configured main control/service boards |
| 2 | AC/DC power module | 1-2 pcs | Standard configuration is single power supply; redundant power supply is optional, shipped according to order configuration |
| 3 | Fan module | 1 set | Standard complete fan assembly, meeting whole-machine cooling requirements |
| 4 | Console configuration cable | 1 pc | RJ45 to DB9 serial cable, 1.5 meters, for local configuration |
| 5 | Power cable | 1-2 pcs | National standard three-pin power cable, 1.8 meters, corresponding to the number of power modules |
| 6 | Rack mounting kit | 1 set | Includes rails, mounting screws, and clips for standard equipment cabinet installation |
| 7 | Dust filter | 1 pc | Standard installed at air intake, includes 1 spare dust filter pad |
| 8 | Product certificate of conformity | 1 copy | Factory quality conformity certificate |
| 9 | Product warranty card | 1 copy | Warranty service voucher, please keep in a safe place |
| 10 | This manual | 1 copy | Printed installation and commissioning manual; electronic version available for download from the official website |
4.2 Optional Accessory Checklist
Optional accessories must be ordered separately and selected according to actual project requirements. Our company provides the full range of original manufacturer accessories. The use of original manufacturer accessories is recommended to ensure device performance and reliability.
4.2.1 Interface Accessories
- Optical Modules: Full series specifications including SFP gigabit optical modules (multi-mode 550m/single-mode 10km/20km/40km/80km), SFP+ 10-gigabit optical modules, QSFP+ 40G optical modules, QSFP28 100G optical modules, and copper port modules;
- Optical Attenuators: 5dB/10dB/15dB fixed optical attenuators and adjustable optical attenuators for long-distance transmission optical power adjustment;
- Fiber Patch Cords: LC-LC, SC-SC, and LC-SC single-mode/multi-mode fiber patch cords, OM3/OM4 10-gigabit multi-mode patch cords;
- Network Cables: Cat5e, Cat6, and Cat6 shielded Ethernet patch cables in selectable lengths;
- WAN Cables: E1 coaxial cables, POS fiber patch cords, and serial cables.
4.2.2 Hardware Expansion Accessories
- Main Control Boards: Spare main control boards for dual main control redundancy configuration;
- Service Line Cards: Full series boards including general-purpose routing service boards, security service boards, WAN interface boards, and value-added service boards;
- Power Modules: Redundant power modules, selectable by power rating and power supply type;
- Fan Modules: Spare fan assemblies;
- Expansion Sub-Cards: Interface sub-cards and encryption sub-cards.
4.2.3 Operations Tool Accessories
- Optical Power Meter: Handheld optical power meter for fiber link loss testing;
- Visual Fault Locator: Red-light pen for fiber fault detection, used for fiber continuity and breakpoint detection;
- Serial to USB Cable: USB to RJ45 Console cable, adapted for laptops without serial ports;
- Tool Kit: Professional network engineering tool kit including crimping pliers, wire strippers, screwdrivers, etc.
4.3 Installation Tool Checklist
The following tools should be prepared before device installation to ensure a smooth installation process:
- Basic Tools: Phillips screwdrivers (PH1, PH2), flat-head screwdriver, hex key set, adjustable wrench, diagonal cutting pliers, wire strippers, crimping pliers;
- Measurement Tools: Tape measure, spirit level, multimeter, optical power meter, visual fault locator;
- Auxiliary Tools: Anti-static wrist strap, anti-static gloves, cable ties, label paper, marker pen, ladder (for cabinet installation);
- Commissioning Tools: Laptop computer (with serial port or USB-to-serial adapter), Console cable, spare network cables, fiber patch cords.
4.4 Unpacking and Inspection Procedures
- Outer Packaging Inspection: Before opening, inspect whether the device packaging box is intact and free of damage, water stains, or impact marks. If the outer packaging is severely damaged, take photos for documentation and contact the logistics carrier and manufacturer. Do not open the box.
- Unpacking Sequence: Open along the packaging sealing markings. First remove the packing list and manual, then sequentially remove the accessory package and host unit. Do not use violent methods to open, to avoid scratching the device.
- Model Verification: Verify against the order and packing list, checking device model, configuration, and quantity. Confirm that the main control board, power supply, interface modules, and other configurations match the order.
- Appearance Inspection: Check the device body for deformation, paint peeling, or scratches. Check interfaces for damage or foreign objects. Verify slot blank panels are intact and fan/power modules are firmly inserted.
- Power-On Preliminary Test: Where conditions permit, a simple power-on test can be performed after unpacking to confirm the device boots normally, indicator lights display correctly, and there are no abnormal alarms.
- Sign-off Confirmation: After inspection confirms no issues, sign on the delivery note to confirm receipt. If there are shortages or damage, note them on the delivery note, refuse acceptance, and contact the manufacturer for handling.
Chapter 5 Product Working Principles
5.1 Overall Architecture Principles
The aggregation layer router adopts a distributed architecture with separated control plane and forwarding plane. The two planes operate independently and collaborate with each other, ensuring both the stability of control management and high-speed forwarding of data packets.
5.1.1 Control Plane
The control plane runs on the main control board CPU and serves as the device’s “decision center,” responsible for all protocol computation, system management, and table entry generation. Its workflow is as follows:
- Receives protocol packets sent by other devices on the network (e.g., OSPF Hello packets, BGP Update packets);
- Runs routing protocol algorithms, calculates network topology and optimal routing paths, and generates the Routing Table;
- Generates forwarding tables (FIB – Forwarding Information Base), ARP tables, MAC address tables, and other forwarding-required tables based on the routing table;
- Distributes the generated forwarding table entries to the forwarding chips of each service board via the backplane bus;
- Handles device configuration management, status monitoring, alarm processing, user interaction, and other management functions.
The control plane does not process business data packets; it only processes protocol packets and management packets. Therefore, even under full business traffic load, device management and protocol operation remain unaffected. Under a dual main control architecture, the active and standby control planes synchronize data in real time, ensuring seamless failover during faults.
5.1.2 Forwarding Plane
The forwarding plane runs on the hardware forwarding chips of the service boards and serves as the device’s “execution center,” responsible for high-speed reception, table lookup, processing, and transmission of data packets. Its workflow is as follows:
- Packet Reception: The interface module receives data packets from the network, performs physical layer and link layer parsing, and extracts packet header information;
- Table Lookup Forwarding: Matches the packet’s destination IP, five-tuple, and other information against the FIB table, ACL table, and QoS table in the forwarding chip to obtain the outgoing interface and processing actions;
- Service Processing: Based on the table lookup result, performs NAT address translation, QoS scheduling, ACL filtering, VPN encapsulation/decapsulation, and other service processing;
- Packet Transmission: Encapsulates the link layer header on the processed packet and sends it to the next-hop device through the outgoing interface.
The forwarding plane implements hardware wire-speed forwarding based on dedicated ASIC/NP chips. Packet processing does not pass through the CPU, resulting in extremely high forwarding performance and ultra-low latency, enabling full-port wire-speed forwarding.
5.1.3 Data Interaction Flow
The control plane and forwarding plane interact through a dedicated internal channel. The control plane distributes table entries and configuration downward, while the forwarding plane reports alarms, statistics data, and abnormal packets upward. The advantages of this separated architecture are:
- High Performance: Data forwarding is completed by hardware chips, unaffected by CPU performance limitations;
- High Reliability: Control plane faults do not affect existing forwarding services; forwarding plane faults do not affect device management;
- Strong Scalability: Adding new service boards expands forwarding performance, while the control plane centrally manages all boards.
5.2 Routing and Forwarding Principles
Routing and forwarding is the core function of the aggregation layer router, implementing cross-subnet packet forwarding based on the longest-match principle and route priority mechanism.
5.2.1 Routing Table and Forwarding Table
Routing Table
The routing table is stored in the control plane’s memory and is the collection of all routing entries calculated by routing protocols. Each routing entry contains destination subnet, subnet mask, next-hop address, outgoing interface, routing protocol, priority, metric value, and other information.
- Route Priority: Different routing protocols have different trust levels. The smaller the priority value, the higher the trust level. When multiple routes to the same destination subnet exist from different protocols, the route with the highest priority is selected for the active routing table. Common route priorities: Direct route 0, Static route 60, OSPF 10, IS-IS 15, BGP 255.
- Metric Value: Within the same routing protocol, this parameter measures path quality — the smaller the metric, the better the path. When multiple routes to the same destination subnet exist within the same protocol, the route with the smallest metric is selected as the optimal route.
Forwarding Table (FIB Table)
The FIB table contains the optimal route entries extracted from the routing table and is distributed to the forwarding chips for actual packet forwarding. Each entry in the FIB table contains destination subnet, next hop, outgoing interface, encapsulation information, etc. The forwarding chip directly queries the FIB table to complete packet forwarding without CPU involvement.
- Longest Match Principle: When a packet’s destination IP matches multiple FIB entries, the entry with the longest subnet mask (i.e., the most precise subnet) is selected for forwarding. For example, if destination IP 192.168.1.10 simultaneously matches 192.168.1.0/24 and 192.168.1.0/28, the /28 entry takes priority.
5.2.2 Unicast Packet Forwarding Process
1. The router receives the data frame from the ingress interface, strips the Layer 2 frame header, and extracts the IP packet;
2. Checks the IP packet header validity, including version, checksum, length, etc.; illegal packets are discarded directly;
3. Queries the FIB table using the destination IP as the key. If no routing entry matches, the packet is discarded and an ICMP unreachable message is returned to the source;
4. If the optimal route is matched, obtains the next-hop IP address and outgoing interface;
5. Queries the ARP table to obtain the MAC address corresponding to the next-hop IP;
6. Encapsulates the Layer 2 data frame header (destination MAC is the next-hop MAC, source MAC is the outgoing interface MAC);
7. Sends the encapsulated data frame from the outgoing interface to the next-hop device.
5.2.3 Dynamic Routing Protocol Working Principles
Taking the most commonly used OSPF protocol as an example, dynamic routing protocols achieve dynamic route updates and self-healing through automatic neighbor discovery, link state exchange, and route path calculation.
- Neighbor Discovery Phase: The router periodically sends Hello packets on interfaces where OSPF is enabled, discovers OSPF neighbors on the same subnet, and establishes neighbor relationships after parameter negotiation;
- Link State Exchange Phase: Neighbors exchange LSAs (Link State Advertisements) that describe their interfaces, subnets, costs, and other link information. Eventually, all routers synchronize to the same Link State Database (LSDB);
- Route Calculation Phase: Based on the LSDB, each router uses the SPF (Shortest Path First) algorithm with itself as the root node to calculate the shortest paths to all destination subnets, generating the OSPF routing table;
- Route Maintenance Phase: Hello packets maintain neighbor relationships. When links change, LSAs are updated and flooded across the entire network, and all routers recalculate routes, achieving automatic route convergence during network topology changes.
5.3 QoS Working Principles
The QoS (Quality of Service) function of the aggregation layer router achieves bandwidth guarantee and low latency for key services through traffic classification, policing, and scheduling, resolving service quality issues during network congestion.
5.3.1 QoS Processing Flow
QoS processing is divided into two phases: ingress direction processing and egress direction processing. The complete flow is as follows:
- Traffic Classification: At the ingress interface, packets are classified into different service categories based on the five-tuple (source IP, destination IP, source port, destination port, protocol number), VLAN, DSCP, 802.1p, application type, and other characteristics;
- Traffic Policing: Bandwidth thresholds are set for each traffic category. Traffic exceeding the threshold is discarded or remark with lower priority, limiting bandwidth consumption by non-critical services;
- Congestion Avoidance: Through mechanisms such as WRED (Weighted Random Early Detection), low-priority packets are proactively discarded before queue congestion occurs, avoiding global packet loss when queues are full, and ensuring high-priority services;
- Queue Scheduling: At the egress interface, packets of different priorities are placed into different queues. Scheduling algorithms determine packet transmission order, ensuring high-priority services are sent first while low-priority services still receive allocated bandwidth;
- Traffic Shaping: Rate smoothing is performed on egress traffic, shaping bursty traffic into uniform traffic to avoid congestion at downstream devices caused by traffic bursts.
5.3.2 HQoS Hierarchical QoS Principles
Traditional QoS can only perform single-level scheduling based on ports, which cannot meet the refined scheduling requirements of “multi-user + multi-service.” The aggregation layer router supports HQoS (Hierarchical QoS), implementing multi-level nested queue scheduling, typically divided into three layers:
- Layer 1: User-Level Queues: Each user/access node corresponds to a first-level queue, guaranteeing the total bandwidth of each user;
- Layer 2: Service-Level Queues: Under each user queue, multiple service sub-queues (voice, video, data) are further divided, guaranteeing priority among different services within the same user;
- Layer 3: Port-Level Scheduling: All user queues undergo total bandwidth scheduling at the egress port, ensuring the port’s total bandwidth does not exceed limits.
HQoS technology is particularly suitable for carrier broadband access, campus multi-department aggregation, and similar scenarios, enabling dual bandwidth guarantees by user and by service, with a refinement level far exceeding traditional QoS.
5.4 High Reliability Working Principles
As a critical network node, the aggregation layer router achieves carrier-grade high reliability through three mechanisms: hardware redundancy, protocol protection, and rapid fault detection.
5.4.1 Hardware Redundancy Principles
- Dual Main Control Redundancy: Adopts 1+1 active/standby mode. During normal operation of the active main control, the standby main control is in hot-standby state, synchronizing configuration, routing tables, session tables, and other data in real time. When the active main control fails, the standby main control takes over the control plane within 50ms. Since forwarding tables have already been distributed to forwarding chips in advance, data forwarding is uninterrupted, achieving NSR (Non-Stop Routing).
- Power Redundancy: 1+1 or N+1 redundant power supplies operate in parallel with load sharing. When a single power supply fails, the remaining supplies immediately assume the full load, with no output voltage fluctuation and no service impact.
- Fan Redundancy: N+1 redundant fans. When a single fan fails, the remaining fans increase speed to compensate for cooling capacity. The device continues normal operation and supports hot-swappable replacement.
5.4.2 Link and Node Protection Principles
- Link Aggregation (LACP): Bundles multiple physical links into one logical link, increasing bandwidth while achieving link redundancy. When a single physical link fails, traffic automatically switches to other links with millisecond-level switching time and no service interruption.
- VRRP Virtual Router Redundancy: Multiple aggregation routers form a virtual gateway sharing the same virtual IP. When the master gateway fails, the backup gateway takes over the virtual IP within seconds. End users recover network connectivity without modifying their gateway settings, achieving gateway redundancy.
- FRR Fast Re-route: Backup paths are calculated in advance and distributed to the forwarding table. When the primary link fails, the forwarding chip directly switches to the backup path without waiting for routing protocol reconvergence. Switching time is ≤50ms, meeting the protection requirements of latency-sensitive services such as voice and video.
- BFD Fast Detection: Bidirectional Forwarding Detection protocol sends detection packets at millisecond-level intervals, rapidly detecting link and node connectivity. Detection time can be as low as 10ms. When used with routing protocols, VRRP, and FRR, it significantly shortens fault convergence time.
5.5 Security Protection Principles
As a network boundary node, the aggregation layer router possesses multi-layered security protection capabilities, securing the network from three dimensions: hardware-level, system-level, and service-level.
5.5.1 Hardware-Level Security
- Domestic Chip Independent Controllability: Xinchuang (information technology application innovation) models use fully domestic hardware, eliminating backdoor risks from foreign chips;
- Hardware Encryption Engine: Built-in national cryptographic algorithm hardware chips. Encryption operations are completed by hardware, offering high performance and strong security, avoiding the performance loss and security vulnerabilities of software encryption;
- Physical Security: Supports chassis anti-theft locks, configuration encryption, and log anti-tampering, preventing physical contact attacks and configuration tampering.
5.5.2 System-Level Security
- Independent Controllable Operating System: The LA-OS system undergoes security hardening, closing unnecessary ports and services to minimize the attack surface;
- DDoS Attack Protection: Supports protection against multiple DDoS attack types including SYN Flood, UDP Flood, and ICMP Flood. Hardware chips identify and clean attack traffic, ensuring availability of normal services;
- User Permission Control: Supports multi-level user permissions, AAA authentication, and login IP restrictions to prevent unauthorized device access. Operation logs are comprehensively recorded, supporting audit and traceability.
5.5.3 Service-Level Security
- ACL Access Control: Access control lists based on Layer 2 to Layer 7 information, precisely filtering illegal traffic and prohibiting unauthorized access;
- Stateful Firewall: Session-based stateful inspection firewall that only allows legitimate return packets to pass, blocking external proactive attacks;
- VPN Encrypted Transmission: Supports VPN technologies such as IPSec and SSL, encrypting data transmitted across public networks to prevent data eavesdropping and tampering;
- Intrusion Prevention: Built-in intrusion prevention signature database that identifies common network attacks and vulnerability exploitation behaviors, blocking attack traffic in real time.
Chapter 6 Product Technical Specifications
6.1 Hardware Technical Specifications
6.1.1 Chassis Specifications
| Parameter | LA-AR1024X (Box Entry-Level) | LA-AR3008 (Chassis Mid-to-High-End) | LA-AR7016 (Chassis High-End) |
|---|---|---|---|
| Device Form Factor | 1U Box | 6U Chassis | 16U Chassis |
| Standard Rack Width | 19-inch | 19-inch | 19-inch |
| Main Control Slots | 1 (Integrated Main Control) | 2 (Active/Standby Redundancy) | 2 (Active/Standby Redundancy) |
| Service Board Slots | 2 Expansion Slots | 8 | 16 |
| Switch Fabric Board Slots | Integrated | 2 (Redundant) | 4 (N+M Redundancy) |
| Power Supply Slots | 2 (1+1 Redundancy) | 2 (1+1 Redundancy) | 4 (N+M Redundancy) |
| Switching Capacity | 128Gbps | 2Tbps | 16Tbps |
| Forwarding Performance | 10Mpps | 120Mpps | 960Mpps |
| Routing Table Capacity | 16K | 512K | 4M |
| ACL Entries | 8K | 128K | 1M |
| Maximum Chassis Power | 150W | 800W | 3200W |
| Operating Temperature | 0°C~45°C | 0°C~45°C | 0°C~45°C |
| Storage Temperature | -40°C~70°C | -40°C~70°C | -40°C~70°C |
| Relative Humidity | 10%~90% (Non-condensing) | 10%~90% (Non-condensing) | 10%~90% (Non-condensing) |
| Chassis Weight | ≤8kg | ≤45kg (Fully Configured) | ≤180kg (Fully Configured) |
| Dimensions (WĂ—DĂ—H) | 442mmĂ—320mmĂ—44.5mm | 442mmĂ—450mmĂ—266mm | 442mmĂ—600mmĂ—712mm |
6.1.2 Main Control Board Specifications
| Parameter | Specification |
|---|---|
| CPU Model | Domestic 16-core ARM architecture processor, 2.2GHz clock speed |
| Memory Capacity | 16GB DDR4 (Expandable to 64GB) |
| Flash Capacity | 32GB eMMC |
| Encryption Engine | Built-in national cryptographic SM1/SM2/SM3/SM4 hardware encryption engine |
| Management Interfaces | 1 Console port (RJ45), 1 MGMT Gigabit electrical port, 2 USB 2.0 interfaces, 1 SD card slot |
| Clock Functionality | Supports 1588v2 PTP, Synchronous Ethernet, BITS clock input/output |
| Switchover Time | Active/Standby switchover time ≤50ms |
| Hot Swap | Supported |
6.1.3 Power Module Specifications
| Parameter | 300W AC Power Supply | 1000W AC Power Supply | 2000W DC Power Supply |
|---|---|---|---|
| Input Voltage | 100-240V AC, 50/60Hz | 100-240V AC, 50/60Hz | -36V~-72V DC |
| Rated Output Power | 300W | 1000W | 2000W |
| Conversion Efficiency | ≥92% | ≥94% | ≥94% |
| Protection Functions | Overvoltage, undervoltage, overcurrent, overtemperature, short-circuit protection | Overvoltage, undervoltage, overcurrent, overtemperature, short-circuit protection | Overvoltage, undervoltage, overcurrent, overtemperature, short-circuit protection |
| Hot Swap | Supported | Supported | Supported |
| Operating Temperature | -10°C~60°C | -10°C~60°C | -10°C~60°C |
| MTBF (Mean Time Between Failures) | ≥500,000 hours | ≥500,000 hours | ≥500,000 hours |
6.1.4 Interface Specifications
Gigabit Electrical Port Specifications
- Interface Standard: IEEE 802.3ab
- Rate: 10/100/1000Mbps auto-negotiation
- Transmission Medium: Cat5e or higher UTP (unshielded twisted pair)
- Maximum Transmission Distance: 100 meters
- Interface Type: RJ45
- Supported Functions: Auto-negotiation, MDI/MDIX auto-sensing, flow control
Gigabit Optical Port (SFP) Specifications
- Interface Standard: IEEE 802.3z
- Rate: 1000Mbps
- Interface Type: SFP slot, hot-swappable
- Optical Module Types: Multi-mode (850nm, 550m), Single-mode (1310nm, 10km/20km/40km/80km)
- Supported Functions: Digital diagnostics (DDM), optical power monitoring
10G Optical Port (SFP+) Specifications
- Interface Standard: IEEE 802.3ae
- Rate: 10Gbps
- Interface Type: SFP+ slot, hot-swappable
- Optical Module Types: Multi-mode (850nm, 300m), Single-mode (1310nm, 10km/20km/40km/80km)
- Supported Functions: Digital diagnostics (DDM), optical power monitoring, CRC error statistics
100G Optical Port (QSFP28) Specifications
- Interface Standard: IEEE 802.3bm
- Rate: 100Gbps
- Interface Type: QSFP28 slot, hot-swappable
- Optical Module Types: SR4 Multi-mode (100m), LR4 Single-mode (10km), ER4 Single-mode (40km)
- Supported Functions: Digital diagnostics, channel status monitoring, Forward Error Correction (FEC)
6.1.5 Environmental and Reliability Specifications
- Electromagnetic Compatibility: Complies with GB 9254 Class B, YD/T 968, EN 55022 Class B standards;
- Safety Certifications: Complies with GB 4943.1, UL 60950-1, CE EN 60950-1 standards;
- Seismic Resistance: Complies with GB/T 9813.1-2016 earthquake intensity level 9 requirements;
- MTBF (Mean Time Between Failures): ≥500,000 hours (box type), ≥800,000 hours (chassis type);
- MTTR (Mean Time To Repair): ≤30 minutes (hot-swappable modular component replacement).
6.2 Software Technical Specifications
6.2.1 Routing Protocol Specifications
| Protocol Type | Supported Specifications |
|---|---|
| Static Routes | Supports IPv4/IPv6 static routes, default routes, static route priority, static route BFD linkage |
| RIP | Supports RIP v1/v2, RIPng, split horizon, poison reverse, triggered updates |
| OSPF | Supports OSPF v2/v3, multi-area, Stub/NSSA areas, OSPF FRR, OSPF TE, supports 500+ neighbors |
| IS-IS | Supports IS-IS IPv4/IPv6, Level-1/Level-2, IS-IS FRR, wide metrics |
| BGP | Supports BGP4/BGP4+, BGP VPNv4/VPNv6, BGP EVPN, route reflector, supports 1000+ BGP neighbors, 4M route entries |
| Policy-Based Routing | Supports policy routing based on source IP, destination IP, five-tuple, supports multi-level policies |
| Route Policies | Supports Route-Policy, prefix lists, AS path filtering, community attribute filtering |
6.2.2 Service Function Specifications
- MPLS: Supports LDP, MPLS TE, L3VPN, L2VPN, VPLS, EVPN, supports ≥1024 VPN instances;
- VPN: Supports IPSec VPN (≥1000 tunnels), SSL VPN (≥500 concurrent users), L2TP VPN, GRE VPN;
- NAT: Supports static NAT, dynamic NAT, NAPT, NAT Server, bidirectional NAT, NAT logging, ≥1 million concurrent sessions;
- QoS: Supports traffic classification, traffic policing, traffic shaping, congestion management, congestion avoidance, supports 8 priority queues, supports HQoS three-level scheduling;
- Security: Supports stateful firewall, ACL (Layer 2 to 7), DDoS attack protection, intrusion prevention, URL filtering, national cryptographic algorithms;
- Multicast: Supports IGMP v1/v2/v3, IGMP Snooping, PIM-SM/DM, MSDP, MBGP, ≥4096 multicast groups.
6.2.3 Reliability Specifications
- Device Level: Dual main control hot standby, NSR (Non-Stop Routing), ISSU (In-Service Software Upgrade), hot-swappable critical components;
- Link Level: LACP link aggregation, static aggregation, load sharing, ≥128 aggregation groups;
- Network Level: VRRP/VRRP6, BFD (minimum detection time 10ms), IP FRR, LDP FRR, TE FRR, switchover time ≤50ms;
- System Level: Dual system image backup, automatic configuration backup, automatic fault recovery, watchdog mechanism.
6.2.4 Management and Operations Specifications
- Management Methods: CLI command line, Web graphical management, SSH/Telnet, SNMP v1/v2c/v3, NETCONF, REST API;
- Monitoring Functions: Real-time CPU/memory/temperature/port status monitoring, traffic statistics, optical power monitoring, resource threshold alarms;
- Logging Functions: Syslog, operation logs, security logs, fault logs, hierarchical log storage, remote log server support;
- Upgrade Methods: Local USB upgrade, TFTP/FTP/SFTP remote upgrade, Web upgrade, batch upgrade, supports ISSU smooth upgrade;
- Zero-Configuration Deployment: Supports DHCP Option, ZTP zero-touch provisioning, device automatically retrieves configuration file upon power-on.
Chapter 7 Product Functions and Features
7.1 Core Routing Functions
7.1.1 Full-Scenario Routing Capability
The LA-AR series aggregation layer routers fully support IPv4/IPv6 dual-stack routing, covering the full protocol stack from static routing to BGP, adapting to all routing scenarios from small branches to large metropolitan area networks.
- Flexible Routing Policies: Supports policy-based routing based on source address, destination address, application type, and user tags, enabling flexible routing requirements such as service traffic distribution, link optimization, and bandwidth guarantee. For example, video traffic can be directed to low-latency links and data traffic to high-bandwidth links;
- Ultra-Large Routing Table Capacity: High-end models support 4M BGP routing table entries, capable of carrying the full Internet routing table, meeting the egress routing requirements of carriers and large Internet enterprises. Supports route aggregation and route filtering to optimize routing table size and improve forwarding efficiency;
- Intelligent Route Optimization: Supports dynamic route adjustment based on link quality. Combined with BFD and NQA link quality detection, when the primary link’s latency or packet loss rate exceeds thresholds, traffic is automatically switched to the backup link to ensure service quality.
7.1.2 Full IPv6 Service Support
Fully adapts to IPv6 network upgrade requirements, supporting the complete IPv6 protocol stack and transition technologies, ensuring smooth network evolution.
- Native IPv6 Support: All interfaces, protocols, and services support IPv6, including OSPFv3, BGP4+, IPv6 ACL, IPv6 QoS, IPv6 VPN, etc., enabling full-service carriage in IPv6 environments;
- Rich Transition Technologies: Supports multiple IPv6 transition technologies including dual-stack, 6PE, 6VPE, NAT66, DS-Lite, enabling gradual IPv6 deployment without replacing the existing IPv4 network, protecting user investment;
- IPv6 Security Features: Supports IPv6 firewall, ND attack protection, DHCPv6 Snooping, IPv6 SAVI, and other security functions to defend against network attacks in IPv6 environments and ensure IPv6 network security.
7.2 Multi-Service Convergence Functions
7.2.1 Integrated Security Protection
Breaks the traditional “router + firewall” multi-device stacking architecture by embedding security capabilities directly into the aggregation router, achieving deep integration of routing and security, simplifying network architecture, and reducing deployment and operational costs.
- Stateful Inspection Firewall: Full session-based stateful inspection, supporting security zone division, security policy configuration, inter-zone access control, and attack protection. Enabling the firewall function does not affect forwarding performance, achieving both security and performance;
- Intrusion Prevention System (IPS): Built-in signature database supporting identification and blocking of common network attacks including vulnerability exploits, Trojans, worms, SQL injection, XSS cross-site scripting, and more. The signature database supports online upgrades for continuous protection against new attacks;
- DDoS Attack Protection: Supports detection and cleaning of multiple DDoS attack types including SYN Flood, UDP Flood, ICMP Flood, and DNS Flood. Uses traffic modeling and abnormal behavior identification technology to ensure normal service availability under high-volume attack traffic;
- National Cryptographic Security Capability: Xinchuang models feature built-in national cryptographic hardware encryption engines supporting the full SM1/SM2/SM3/SM4 cryptographic algorithm suite, enabling construction of VPN encryption networks based on national cryptographic standards, meeting cryptographic compliance requirements for government, financial, and other industries.
7.2.2 Refined QoS Scheduling
Features industry-leading HQoS hierarchical QoS capability, implementing multi-level refined scheduling from port to user to service, perfectly adapting to multi-user, multi-service converged carriage scenarios.
- Multi-Dimensional Traffic Identification: Supports traffic classification based on multiple dimensions including VLAN, IP five-tuple, DSCP, 802.1p, application identification, and user accounts, precisely identifying different services and users;
- Flexible Scheduling Algorithms: Supports multiple scheduling algorithms including SP (Strict Priority), WRR (Weighted Round Robin), WFQ (Weighted Fair Queueing), and CBWFQ (Class-Based Weighted Fair Queueing), flexibly combinable according to business requirements. Critical services use SP scheduling for low latency; general services use WFQ scheduling for fairness;
- Bandwidth Guarantee and Rate Limiting: Supports CIR (Committed Information Rate) and PIR (Peak Information Rate) configuration per user and per service, ensuring stable bandwidth for critical services while limiting maximum bandwidth for non-critical services to prevent resource preemption of core services;
- Intelligent Congestion Management: Supports WRED (Weighted Random Early Detection), setting different drop thresholds based on packet priority, preferentially dropping low-priority packets during congestion. Supports queue length monitoring and congestion alarms for early warning of network bottlenecks.
7.2.3 Full-Scenario VPN Interconnection
Supports multiple VPN technologies to meet cross-region interconnection requirements in different scenarios, building secure, flexible, and cost-effective wide area networks.
- IPSec VPN: Suitable for site-to-site fixed leased line replacement, using tunnel mode for encrypted data transmission. Supports IKEv1/v2 key negotiation and national cryptographic algorithms. Highly secure, suitable for fixed site interconnection between enterprise headquarters and branches or cross-region organizations, replacing expensive leased lines and significantly reducing WAN construction costs. Supports tunnel nesting and VPN instance binding, enabling encrypted transmission of multiple independent business services simultaneously with service security isolation. Supports IKE Dead Peer Detection (DPD) for automatic detection of tunnel peer status, with automatic tunnel re-establishment after interruption to ensure business continuity. Supports IPSec-BFD linkage for millisecond-level tunnel fault detection and traffic switchover, meeting encrypted transmission requirements for high-reliability services.
- SSL VPN: Suitable for mobile office and remote employee access scenarios. No dedicated client installation required — secure access to intranet resources is achieved through a browser, compatible with PCs, mobile phones, tablets, and other terminal types. Supports multiple authentication methods including Portal authentication, username/password authentication, SMS authentication, and UKey authentication, and can integrate with enterprise unified identity authentication systems for single sign-on. Supports fine-grained permission control, assigning different intranet access permissions based on user roles to ensure secure and controllable remote access. Supports both SSL VPN tunnel encryption and application-layer proxy access modes, enabling either full network-layer secure access or targeted proxy access to web systems and business systems, flexibly meeting different remote office requirements.
- L2TP VPN: Combines the L2TP tunneling protocol with IPSec encryption technology, suitable for remote dial-in access by enterprise employees and dynamic IP access by branch sites. Supports both client and LNS deployment modes. Supports L2TP multi-instance and tunnel backup, handling large numbers of concurrent remote users. Supports user authentication, accounting, and bandwidth management, and can integrate with AAA servers for unified user management. Suitable for low-cost WAN access scenarios such as retail stores and small branches, establishing secure intranet connections without requiring fixed public IPs.
- GRE VPN: Generic Routing Encapsulation protocol, supporting encapsulation of multiple network layer protocols over IP networks to build transparent virtual private lines, suitable for Layer 2 and Layer 3 transparent transmission across regions. Supports GRE tunnels carrying multicast and dynamic routing protocols, allowing OSPF, BGP, and other routing protocols to run inside tunnels for dynamic routing learning across the entire network. Supports GRE combined with IPSec for data security during transparent transmission, suitable for multi-branch network route interconnection, multicast services across WAN transmission, and similar scenarios.
- MPLS L3VPN: Layer 3 virtual private network based on MPLS label switching, suitable for medium-to-large enterprise multi-branch interconnection and industry private network multi-service isolation scenarios — currently the mainstream WAN VPN technology. Supports the BGP/MPLS VPN architecture, achieving complete isolation of routing and forwarding between different services and tenants through VPN instances, with isolation equivalent to physical private networks. Supports multiple networking modes including Hub-Spoke, Full-Mesh, and hierarchical VPN, flexibly deployable according to business architecture. Supports advanced features including VPN inter-AS, VPN nesting, and VPN NAT, enabling construction of large-scale, multi-level virtual private networks to meet deployment requirements of carrier MAN VPNs, provincial industry private networks, and other large networks.
- EVPN (Ethernet Virtual Private Network): A next-generation VPN technology based on BGP, supporting unified Layer 2 and Layer 3 carriage, suitable for new scenarios including data center interconnection, cloud-network convergence, and 5G bearer networks. Supports multiple encapsulation modes including EVPN VXLAN and EVPN MPLS, enabling cross-region Layer 2 network extension to meet business requirements such as virtual machine migration and cloud resource pool interconnection. Supports fast convergence, multi-homing access, and load sharing, offering stronger reliability and scalability than traditional VPLS technology — the core VPN technology for next-generation WAN carriage.
7.2.4 Multicast and Video Service Carriage
For batch transmission requirements of video services including IPTV, video conferencing, security surveillance, and live streaming, the LA-AR series aggregation routers provide a complete multicast solution, achieving efficient distribution of video traffic and significantly saving network bandwidth.
- Full Protocol Multicast Support: Fully supports multicast protocols including IGMP v1/v2/v3, IGMP Snooping, PIM-SM, PIM-DM, PIM-SSM, MSDP, and MBGP, adapting to both ASM and SSM multicast models to meet multicast service deployment across different scales and scenarios;
- Controllable Multicast Management: Supports multicast CAC (Call Admission Control), limiting multicast channel count and bandwidth based on port, VLAN, or user to prevent multicast flooding from consuming entire network resources. Supports multicast permission control with user authentication for precise authorization of paid channels — unauthorized users cannot receive multicast traffic;
- Multicast QoS Guarantee: Supports multicast traffic priority marking and queue scheduling, mapping video multicast traffic to high-priority queues to ensure low latency, low jitter, and zero packet loss for video services. Supports multicast replication optimization with hardware chips implementing wire-speed multicast packet replication, with no forwarding performance degradation even with full multicast services enabled;
- Multicast Reliability: Supports PIM FRR and fast multicast switchover, enabling rapid switching to backup paths upon multicast link failure with switchover time ≤50ms, ensuring no video stuttering or black screens. Supports dual RP redundancy and MSDP multi-active to prevent single points of failure from interrupting multicast services;
- Live Streaming and Surveillance Adaptation: For security surveillance scenarios, supports aggregation of multicast streams from massive numbers of IPC cameras, with a single device handling forwarding of thousands of surveillance video streams. For live streaming scenarios, supports identification and optimization of streaming protocols including RTSP and RTMP to enhance streaming smoothness.
7.2.5 Network Virtualization and Elastic Scaling
Achieves flexible allocation and elastic scaling of network resources through virtualization technologies, improving resource utilization, simplifying network architecture, and adapting to cloud-era network construction requirements.
- IRF Intelligent Resilient Framework Stacking: Supports stacking multiple box-type aggregation routers into one logical device. After stacking, unified management and unified forwarding table entries simplify network topology and configuration management. Stacking bandwidth can reach hundreds of Gbps, with cross-device link aggregation providing link redundancy and load sharing — a single device failure does not affect entire network operation. Supports up to 9 devices in a stack, with port density and forwarding performance scaling linearly with the number of devices, enabling smooth capacity expansion as business grows without replacing core devices;
- MDC (Multi-Tenant Device Environment): High-end chassis devices support MDC technology, virtualizing one physical router into multiple independent logical routers. Each MDC has independent hardware resources, independent operating system, and independent configuration management, with service isolation equivalent to physical devices. MDC technology enables multiple services and tenants to share one physical device, significantly reducing hardware procurement costs and data center floor space. Suitable for carrier MANs, government cloud multi-department sharing, and similar scenarios;
- VXLAN Virtual Extensible LAN: Supports VXLAN Layer 2 and Layer 3 gateway functions, enabling construction of large Layer 2 virtual networks to meet virtual machine cross-region migration and cloud resource pool interconnection requirements. Supports the EVPN VXLAN control plane for automatic VXLAN tunnel establishment and MAC address learning, offering greater flexibility and scalability than traditional static VXLAN deployment. Adapts to cloud data center aggregation, campus cloudification transformation, and related scenarios;
- Network Slicing Capability: Supports Flex-E (Flexible Ethernet) technology, dividing one physical port into multiple independent logical slices, each with independent bandwidth and independent forwarding plane for carrying different services. Slices are hard-isolated without mutual interference, meeting multi-service hard-isolation carriage requirements in 5G bearer, industrial private network, and similar scenarios.
7.2.6 Intelligent Operations and Automated Management
Aimed at next-generation network operations requirements, built-in rich intelligent and automated operations tools transform traditional manual CLI operations toward visualization, automation, and intelligence, significantly reducing operational complexity and labor costs.
- Zero-Touch Provisioning (ZTP): Supports multiple zero-configuration deployment methods including DHCP Option, USB drive, and email. Upon power-on, the device automatically obtains an IP address, automatically downloads configuration files, and automatically completes system upgrades and service configuration without on-site engineer commissioning, significantly shortening deployment cycles for large-scale projects. For multi-branch projects, devices can be shipped directly from the factory to the site and brought online simply by plugging in, greatly reducing on-site implementation costs and technical barriers;
- Telemetry Technology: Uses push-based data collection technology, collecting performance data in real time at sub-second precision including port traffic, CPU utilization, queue congestion, and packet loss rate, reporting in real time to the network management platform. Compared to traditional SNMP polling, collection precision is improved by a hundredfold, with more real-time and comprehensive data, providing precise data support for network performance analysis and fault location;
- AI Intelligent Operations: Built-in AI operations engine establishes traffic baselines based on historical performance data, automatically identifying potential faults such as traffic anomalies, port congestion, and link degradation, issuing early warnings to enable proactive operations. Supports fault root cause analysis — when network faults occur, automatically investigates causes, locates fault points, and provides repair recommendations, significantly reducing fault troubleshooting time;
- Automated Configuration Interfaces: Supports automated configuration interfaces including NETCONF/YANG, REST API, and Python scripting, enabling integration with enterprise automated operations platforms and cloud management platforms for automated batch configuration, batch upgrade, and status monitoring. Supports mainstream automation tools such as Ansible, adapting to existing enterprise operations systems to achieve full-process automation of network operations.
7.3 Core Product Features
7.3.1 Carrier-Grade High Reliability
All product series adhere to carrier-grade reliability design standards, building a comprehensive reliability system from four dimensions — hardware, software, protocol, and architecture. Chassis availability reaches 99.999%, with average annual business interruption time not exceeding 5 minutes.
- Full Hardware Redundancy Design: Mid-to-high-end chassis devices support redundant configuration and hot swap for main control boards, switch fabric boards, power supplies, and fans. A single component failure does not affect overall machine operation, and failed components can be replaced online without shutdown. Box-type devices come standard with dual power supply redundancy and intelligent fan redundancy, with key components using industrial-grade specifications to reduce failure probability;
- Uninterrupted Business Capability: Supports NSR (Non-Stop Routing) and NSF (Non-Stop Forwarding) technologies. During active/standby main control switchover, the forwarding plane continues operating with no interruption to business traffic. Supports ISSU (In-Service Software Upgrade) with zero business interruption during system version upgrades, meeting the extremely high business continuity requirements of finance, power, carrier, and similar sectors;
- Millisecond-Level Fault Self-Healing: Combines BFD fast detection, FRR fast re-route, VRRP, link aggregation, and other technologies to achieve millisecond-level detection and switchover for link and node faults, with fault switchover time ≤50ms. Real-time services such as voice and video are completely unaffected, ensuring continuous operation of critical services;
- Rigorous Reliability Validation: All products pass multiple reliability tests including high/low temperature cycling tests, long-duration full-load aging tests, electromagnetic compatibility tests, and vibration/shock tests. MTBF (Mean Time Between Failures) is ≥800,000 hours, ensuring long-term stable operation in data center environments.
7.3.2 Full-Stack Independent Controllability and Security Trustworthiness
Xinchuang series products achieve full-chain domestic independent controllability of hardware and software, with proprietary intellectual property rights from core chips to the operating system, fully meeting national information technology application innovation requirements and critical information infrastructure security requirements.
- Fully Domestic Hardware: 100% core components use domestic solutions, featuring domestic multi-core CPUs, domestic high-performance switching chips, and domestic memory and storage, completely eliminating dependence on foreign chips. Backdoor risks are eliminated at the hardware foundation, ensuring supply chain security;
- Independent Controllable Operating System: Powered by KITOZER’s independently developed LA-OS network operating system, deeply customized based on a domestic Linux kernel with complete proprietary intellectual property rights, certified by national authoritative security organizations. System code is independently controllable, supporting customization and security hardening according to industry requirements, adapting to specialized needs of specific sectors;
- National Cryptographic Security System: Built-in national cryptographic algorithm hardware encryption engine, fully supporting SM1, SM2, SM3, and SM4 cryptographic algorithms. Supports national cryptographic VPN, national cryptographic authentication, and national cryptographic data encryption, compliant with State Cryptography Administration regulations, enabling construction of full-link secure networks based on national cryptographic standards;
- Multi-Level Security Certification: Products pass the Confidential Information System Product Testing of the National Administration of State Secrets Protection, the Computer Information System Security Special Product Certification of the Ministry of Public Security, and the Commercial Cryptography Certification of the State Cryptography Administration. Meets Classified Protection 2.0 Level 3 and above security requirements, adapting to security compliance needs of government, finance, energy, transportation, and other critical industries.
7.3.3 Flexible Expansion and Investment Protection
Adopts modular, expandable architecture design, supporting on-demand smooth expansion of performance, interfaces, and services, maximizing user investment protection and adapting to networks with continuously growing business requirements.
- Smooth Performance Expansion: Chassis devices can increase overall forwarding performance and port density by adding service boards and switch fabric boards without replacing the chassis or main control boards. Box-type devices achieve linear performance and port expansion through IRF stacking, expanding from a single unit to multiple stacked units as business grows;
- On-Demand Service Loading: Supports on-demand configuration of service boards and function sub-cards. Users configure corresponding functions based on current business requirements, and when new services are added later, only need to add corresponding service boards or enable software licenses without whole-device replacement. The universal routing platform is compatible with the full series of service boards, supporting mixed insertion of old and new boards to protect user historical investment;
- Technology Evolution Compatibility: Fully compatible with IPv4/IPv6 dual-stack, supporting next-generation network technologies including SRv6, EVPN, and Flex-E, enabling smooth evolution toward future networks and avoiding device obsolescence from technology iteration. Simultaneously compatible with traditional WAN interfaces including E1 and POS, adapting to existing legacy networks and supporting gradual network upgrade and transformation;
- Unified Software Version: The full product series uses the unified LA-OS operating system with identical command line, configuration logic, and management methods. Operations personnel mastering one device can manage the entire product series, reducing learning costs and operational difficulty. Unified version iteration enables new features to be synchronized across the full device series, continuously providing users with feature upgrades.
7.3.4 Green Energy-Saving and Low-Carbon Design
Follows green low-carbon design philosophy, reducing device energy consumption from multiple dimensions including hardware selection, architecture design, and intelligent control, contributing to energy-saving and emission-reduction goals of data centers and equipment rooms.
- High-Efficiency Power Design: Uses 80PLUS Platinum-grade high-efficiency power modules with conversion efficiency up to 96%, significantly reducing power conversion losses. Supports intelligent power regulation that dynamically adjusts power supply output based on actual device load, reducing energy waste during idle and light-load conditions;
- Intelligent Cooling System: Uses zoned intelligent temperature-controlled cooling solutions. The device incorporates dozens of temperature sensors monitoring temperatures in each zone in real time, dynamically adjusting fan speeds based on temperature and load. Fans run at low speed under low-load, low-temperature conditions, significantly reducing energy consumption and noise. Key chips use refined cooling designs for higher cooling efficiency, reducing overall cooling power consumption by over 30%;
- Chip-Level Energy Efficiency Optimization: Uses next-generation low-power switching chips and processors with leading process technology, delivering lower power consumption at equivalent performance. Supports energy-saving technologies including port sleep and dynamic power adjustment — idle ports automatically enter low-power mode, and chip operating frequency automatically decreases when business traffic decreases, balancing performance and energy efficiency;
- Material Environmental Compliance: All machine materials comply with RoHS environmental standards — lead-free and mercury-free, reducing environmental pollution. Packaging uses recyclable paper materials to reduce plastic usage, practicing green environmental philosophy.
7.3.5 Minimal Operations and Intelligent Management
Starting from user operations experience, provides multi-dimensional, full-scenario management methods, simplifying the entire process of device configuration, monitoring, and troubleshooting, making network operations simpler and more efficient.
- Multi-Method Management Compatibility: Supports multiple management methods including traditional CLI command line, Web graphical management, cloud management platform, and mobile APP, satisfying both the efficient command-line configuration needs of senior network engineers and the visual graphical management needs of general operations personnel. The Web management interface features Chinese visual design with wizards for configuration and graphical monitoring, enabling routine configuration and monitoring without memorizing complex commands;
- Visual Operations Panel: The Web network management system provides an intuitive visual operations panel displaying device topology, port status, traffic trends, resource utilization, and alarm information in real time — network-wide status at a glance. Supports traffic heat maps and congestion warning alerts, enabling operations personnel to quickly grasp network operating status and promptly identify potential issues;
- One-Click Fault Diagnosis: Built-in intelligent fault diagnosis tool supports one-click collection of device logs, status, configuration, and other diagnostic information, automatically analyzing common faults and providing solutions. Supports remote diagnosis — technical support personnel can quickly locate faults through remote assistance, significantly shortening fault repair time;
- Unified Management Platform: Can interface with the KITOZER intelligent network management platform for unified management of multiple devices and sites, supporting batch configuration deployment, batch version upgrades, unified alarm monitoring, and performance report generation. Suitable for large-scale network operations with multiple branches and nodes, significantly improving operations efficiency.
Chapter 8 Product Application Scenarios
The LA-AR series aggregation layer routers, with their rich service features, flexible product form factors, and high-reliability hardware design, are widely applied across enterprises, carriers, government, finance, energy, transportation, education, healthcare, and other industries, adapting to network aggregation layer deployments of different scales and architectures. This chapter provides detailed descriptions of typical application scenarios, illustrating device networking solutions, functional value, and deployment key points.
Chapter 8: Typical Application Scenarios for Aggregation Layer Routers
8.1 Large and Medium Enterprise Campus Network Aggregation Scenario
8.1.1 Scenario Overview
Large and medium enterprise campuses typically consist of multiple office buildings with thousands to tens of thousands of terminal nodes. The network adopts a three-tier architecture: Core Layer – Aggregation Layer – Access Layer. Aggregation layer routers are deployed per building or per zone, carrying all traffic from access switches within their area and uplinking to core routers. They serve as the traffic hub and policy enforcement point of the campus network. Additionally, enterprises commonly have requirements for multi-branch interconnection, remote office access, and multi-service bearing, placing high demands on the service capability, reliability, and scalability of aggregation layer devices.
8.1.2 Network Architecture
- Access Layer: Access layer switches are deployed on each floor, connecting desktop terminals, IP phones, wireless APs, cameras, and other end devices via Gigabit twisted-pair cabling.
- Aggregation Layer: Each building is deployed with 1–2 LA-AR series aggregation routers in a dual-device hot-standby architecture, connecting all access switches within the building via 10G fiber optics. Multiple VLANs are configured within the building, and inter-VLAN routing is completed at the aggregation layer.
- Core Layer: Core routers are deployed at the campus center, connecting to aggregation routers of each building via 10GE/40GE links to achieve high-speed forwarding of cross-building traffic.
- WAN Interconnection: The aggregation or core layer connects to WAN links, implementing interconnection with the enterprise headquarters and remote branches via IPSec/MPLS VPN, and enabling remote office access for employees via SSL VPN.
8.1.3 Core Device Value
- Multi-service Converged Bearer: A single device simultaneously carries office data, voice calls, video conferencing, security surveillance, wireless WiFi, and other services. HQoS technology enables service-level scheduling to guarantee low latency and high reliability for real-time services such as voice and video, solving the quality issues of multi-service mixed transmission.
- Refined Security Control: Access control policies and firewall functions are deployed at the aggregation layer to achieve security isolation between departments and business zones, preventing unauthorized access and lateral attacks. Combined with terminal authentication, it implements identity verification and permission control for access terminals, securing the intranet.
- High-reliability Architecture Assurance: Dual-device VRRP hot-standby plus link aggregation architecture ensures that a single device or link failure does not affect business operation. All critical components feature full redundancy design, achieving 99.999% device availability and guaranteeing 7Ă—24 stable operation of enterprise services.
- Smooth Scalability for Growth: Modular devices can gradually expand ports and functions as enterprise business grows, without requiring full-unit replacement. IRF stacking technology is supported, virtualizing multiple devices into one, simplifying management while enhancing performance to accommodate enterprise scale expansion.
8.1.4 Deployment Key Points
- Dual-device redundant deployment is recommended at the aggregation layer to avoid single points of failure; dual-uplink configuration is recommended for core business zones to achieve link redundancy and load sharing.
- Divide VLANs and VPN instances by department and service type to achieve service isolation and reduce the scope of fault impact.
- Configure QoS policies to classify voice, video conferencing, and production services as high priority, guaranteeing bandwidth for critical services.
- Enable logging and audit functions to record network access and operation logs, meeting enterprise security compliance requirements.
8.2 Carrier Metro Network Access/Aggregation Scenario
8.2.1 Scenario Overview
Carrier metro networks typically adopt a three-tier architecture: Core – Aggregation – Access. Aggregation layer routers are deployed at POP points in each district/county, carrying broadband access, leased line access, 5G bearer, and other service traffic within the region, and forwarding uplink to the metro network core layer. In this scenario, devices must possess large capacity, high reliability, carrier-grade O&M, and multi-service bearer capability, while also supporting carrier-grade features such as BRAS, SRv6, and EVPN. These devices are critical nodes in the carrier metro network.
8.2.2 Network Architecture
- Access Layer: Includes OLT, DSLAM, community switches, and other access devices, covering home broadband, enterprise leased lines, base station backhaul, and other access services.
- Aggregation Layer: LA-AR high-end chassis aggregation routers are deployed at each district/county POP point, featuring dual main control boards, dual power supplies, and dual uplinks for high reliability. They connect to various access devices via GE/10GE interfaces, carrying all access traffic within the region.
- Core Layer: Core routers are deployed at the metro network core, connecting aggregation nodes via 100G/400G high-speed links to achieve high-speed forwarding and egress scheduling for metro traffic.
- Service Layer: Aggregation layer routers integrate BRAS functionality to implement broadband user access authentication, billing, and bandwidth control. They also carry services such as 5G base station backhaul, enterprise leased lines, and IPTV.
8.2.3 Core Device Value
- Large-capacity High-performance Forwarding: High-end chassis devices provide T-level switching capacity and hundreds of Mpps of forwarding performance, supporting high-density 10GE/100GE interfaces. They can carry access traffic from tens of thousands of users within a region, meeting the traffic growth demands of high-bandwidth video, 5G, and other services.
- Full-service Bearer Capability: A single device simultaneously carries multiple service types including home broadband, enterprise leased lines, IPTV, and 5G backhaul. HQoS enables fine-grained bandwidth scheduling per user and per service. Built-in BRAS functionality can replace traditional standalone BRAS devices, simplifying network architecture and reducing construction costs.
- Carrier-grade Reliability: Full hardware redundancy design with support for carrier-grade reliability features such as NSR and ISSU, achieving 99.999% system availability. Supports sub-50ms fault switching for seamless user experience. Carrier-grade OAM enables end-to-end link and service O&M monitoring.
- Cloud-network Convergence Evolution Capability: Supports next-generation bearer network technologies including SRv6, EVPN, and Flex-E, enabling smooth evolution toward cloud-network convergence and 5G bearer networks, protecting carrier investment. Network slicing is supported, providing dedicated isolated network slice services for customers in different industries, empowering carrier enterprise business innovation.
8.2.4 Deployment Key Points
- Aggregation nodes must adopt dual-device redundant architecture with all critical components redundantly configured to ensure no single points of failure.
- Plan rational routing domains and IP address segments, implement route aggregation, optimize routing table size, and improve forwarding efficiency.
- Configure comprehensive QoS policies to differentiate service levels and guarantee service quality for high-value services.
- Integrate with carrier OSS/BSS systems to achieve unified management of resources, users, billing, and O&M.
- Deploy Telemetry systems for fine-grained network performance monitoring and intelligent O&M.
8.3 Government Affairs Private Network Aggregation Scenario
8.3.1 Scenario Overview
Government affairs private networks adopt a four-tier architecture: Province – City – District/County – Township. Aggregation layer routers are deployed at the city and district/county levels, carrying government service traffic from departments at their level and subordinate units, enabling secure transmission and sharing of government data. Government affairs private networks have extremely high requirements for independent controllability, security compliance, service isolation, and reliability, and must meet the requirements of Classified Protection 2.0 (Classified Protection 2.0), Xinchuang (IT innovation) transformation, and classified information system specifications.
8.3.2 Network Architecture
- Access Nodes: Government terminals in district/county departments and township/street offices connect to local aggregation nodes via access switches.
- District/County Aggregation Layer: LA-AR Xinchuang security aggregation routers are deployed at each district/county with dual-device hot-standby deployment, connecting all departmental access nodes within the jurisdiction. Different business VPNs are configured for service isolation.
- City-level Aggregation Layer: High-end aggregation routers are deployed at the city level, connecting to district/county aggregation nodes to achieve aggregation and forwarding of city-wide government data, with uplink to the provincial government network.
- Security Protection: Security mechanisms such as national cryptography encryption, firewalls, and intrusion prevention are deployed at aggregation nodes to achieve intranet/extranet isolation and business domain isolation, safeguarding government data security.
8.3.3 Core Device Value
- Full-stack Xinchuang Independent Controllability: Hardware and software are 100% domestically produced, compliant with the National Xinchuang Product Catalog requirements, completely eliminating reliance on foreign technology and ensuring the security of the government network supply chain and data. Equipped with a domestically developed operating system, it can be security-hardened and custom-developed as needed to adapt to specific government requirements.
- Multi-service Security Isolation: Through MPLS VPN, virtual firewall, and other technologies, physical-level isolation is achieved among government office services, public services, classified services, and other service types. Service systems operate without mutual interference, meeting the hierarchical protection requirements of government networks. Fine-grained service access control strictly manages cross-departmental data access permissions.
- National Cryptography Security Compliance: Built-in national cryptography hardware encryption engine supports the full suite of national cryptographic algorithms, ensuring end-to-end national cryptographic encryption for government data transmitted across networks, compliant with State Cryptography Administration regulations. Passed authoritative security certifications from the National Administration of State Secrets Protection and the Ministry of Public Security, meeting compliance requirements for Classified Protection Level 3 and above and classified information systems.
- High-reliability Stable Operation: Carrier-grade hardware redundancy design with all critical components hot-swappable and redundant, ensuring 7Ă—24 uninterrupted operation of the government network. Dual redundancy for both links and nodes with millisecond-level fault switching ensures uninterrupted government services, meeting the people’s needs for continuous government service availability.
8.3.4 Deployment Key Points
- Strictly follow government network security specifications, properly implement business domain division and security isolation, and prohibit unauthorized cross-domain access.
- Use Xinchuang model devices to ensure full-stack domestic production, meeting Xinchuang transformation acceptance requirements.
- Deploy unified security management and log audit systems, with all operations and access activities fully recorded for compliance audit requirements.
- Configure national cryptography VPN encryption; cross-regional government data transmission must be encrypted.
- Establish comprehensive O&M management policies, restrict device management permissions, and implement O&M auditing.
8.4 Financial Industry Private Network Aggregation Scenario
8.4.1 Scenario Overview
Financial industry (banking, securities, insurance) network architectures are highly standardized, typically adopting a three-tier structure: Head Office – Branch – Sub-branch. Aggregation layer routers are deployed at branches or prefecture-level sub-branches, carrying business traffic from outlets, self-service devices, and office terminals within their jurisdiction, with uplink to the head office data center. The financial industry has extremely high requirements for business continuity, data security, and low transaction latency. Any network failure can cause enormous economic losses and reputational damage.
8.4.2 Network Architecture
- Access Layer: Access devices are deployed at sub-branch outlets and self-service banking locations, connecting counter terminals, ATMs, self-service devices, and office terminals.
- Aggregation Layer: Dual LA-AR aggregation routers are deployed at prefecture-level branches in dual-device hot-standby architecture, connecting all sub-branch outlets within the jurisdiction via leased lines, carrying production services, office services, video surveillance, and other traffic.
- Core Layer: Core routers and data center equipment are deployed at the head office/provincial branch, connecting to aggregation nodes of each branch via high-speed leased lines, achieving unified service bearing and data exchange across the entire bank.
- Backup Links: Each aggregation node is configured with primary and backup leased line links from two different carriers, plus 5G/4G backup links, achieving multi-link redundancy backup.
8.4.3 Core Device Value
- Extreme Business Reliability: Full redundant hardware architecture plus full link redundancy design, supporting multiple reliability mechanisms including NSR, FRR, and dual-device hot-standby. Fault switching time is millisecond-level, completely transparent to transaction services. 99.999% system availability guarantees perpetual operation of financial services, eliminating business interruption risks.
- Financial-grade Security Protection: Built-in financial-grade firewall, intrusion prevention, and DDoS protection functions, combined with VPN encrypted transmission, build an end-to-end security protection system. Supports financial dedicated encryption algorithms and national cryptographic algorithms, ensuring secure transaction data transmission and preventing data leakage and tampering.
- Low Latency for Transaction Services: Hardware chip-based wire-speed forwarding with packet forwarding latency as low as microsecond level. Transaction traffic priority scheduling ensures core transaction services enjoy dedicated bandwidth and priority forwarding, meeting low-latency requirements for financial transactions.
- Multi-service Isolated Bearer: VPN instances achieve complete isolation of production services, office services, video surveillance, and external connection services. Different services do not affect each other, complying with financial industry network security specifications. Fine-grained access control strictly manages access permissions between service domains.
8.4.4 Deployment Key Points
- Strictly follow financial industry network security specifications; production network and office network must be physically or logically isolated, prohibiting unauthorized cross-network access.
- All nodes adopt dual-device dual-link redundant deployment, with primary and backup links routed through different physical paths to avoid single points of failure and single-link failures.
- Configure refined QoS policies with production transaction services at the highest priority, guaranteeing bandwidth and latency.
- Deploy comprehensive log audit and security monitoring systems, with all operations and traffic fully traceable.
- Conduct regular disaster recovery drills to verify fault switching and service recovery capabilities.
8.5 Energy and Power Industry Private Network Aggregation Scenario
8.5.1 Scenario Overview
Industrial production private networks in the energy sector (electric power, petroleum, coal) cover production sites such as substations, oil production plants, and mining areas. Aggregation layer routers are deployed at regional centralized control centers, carrying traffic from industrial terminals, measurement and control devices, and cameras within the jurisdiction, enabling collection, transmission, and control of production data. This scenario features complex and harsh environments, requiring devices with wide temperature tolerance, interference resistance, and industrial-grade reliability. Production control services also place extremely high demands on real-time performance and reliability.
8.5.2 Network Architecture
- Field Access Layer: Industrial switches are deployed at substations and mining sites, connecting PLCs, RTUs, measurement and control devices, industrial cameras, sensors, and other terminals.
- Regional Aggregation Layer: LA-AR industrial-grade aggregation routers are deployed at prefecture/regional centralized control centers, connecting all field access nodes within the jurisdiction via fiber optics, aggregating production control, video surveillance, office management, and other service traffic.
- Core Dispatching Layer: Core routers are deployed at provincial/headquarters dispatching centers, connecting to regional aggregation nodes to achieve unified dispatching and monitoring of production data across the entire region.
- Clock Synchronization: 1588v2 PTP precise time synchronization is deployed across the entire network to ensure consistent time accuracy for industrial measurement and control devices.
8.5.3 Core Device Value
- Industrial-grade Environmental Adaptability: Industrial-grade models support wide temperature operation from -40°C to 75°C, with high-level electromagnetic compatibility protection, moisture resistance, and corrosion resistance. They can adapt to harsh industrial environments such as substations and mining areas, operating stably regardless of environmental conditions.
- High-reliability Industrial Bearer: Supports industrial-grade redundancy protocols with fault switching time ≤50ms, ensuring uninterrupted production control services. Dual power supplies and dual main control boards with hot-swappable critical components adapt to 7×24 uninterrupted operation requirements at industrial sites.
- High-precision Clock Synchronization: Supports 1588v2 PTP precise time protocol and Synchronous Ethernet, with time synchronization accuracy reaching sub-microsecond level, meeting high-precision time synchronization requirements for power differential protection, industrial measurement and control, and other services.
- Industrial Protocol Adaptation: Supports transparent transmission and parsing of industrial dedicated protocols including Modbus, IEC 60870-5-104, and IEC 61850, adapting to industrial control systems in the power and petrochemical industries. Supports industrial data priority scheduling, ensuring priority transmission of control commands with low latency and zero packet loss.
8.5.4 Deployment Key Points
- Prioritize industrial-grade model devices to adapt to harsh field environments; implement dust protection, heat dissipation, and moisture prevention measures in equipment rooms/cabinets.
- Strictly isolate the production control network from the office management network; the production network is prohibited from accessing the Internet to ensure production safety.
- Deploy a high-precision time synchronization system to ensure time consistency across all industrial devices.
- Configure link and device redundancy; production links should use dual-route backup to prevent single-link failures from affecting production.
- Implement network security protection by deploying industrial firewalls and access control policies to prevent network attacks from impacting production safety.
8.6 Transportation Industry Private Network Aggregation Scenario
8.6.1 Scenario Overview
Transportation industry private networks (rail transit, expressways, airports, ports) cover stations, toll booths, and surveillance points along the route. Aggregation layer routers are deployed at road section/line control centers, carrying toll collection, surveillance, dispatching, and communication service traffic from all access nodes along the route. They serve as the network bearing core of intelligent transportation systems.
8.6.2 Network Architecture
- Along-route Access: Access switches are deployed at expressway toll stations, tunnels, surveillance points, metro stations, and signal equipment locations, connecting toll terminals, cameras, signal equipment, broadcast systems, and more.
- Road Section Aggregation: LA-AR aggregation routers are deployed at road section/line control centers with dual-device redundant deployment, connecting all access nodes along the route via fiber optic ring networks, aggregating toll collection, surveillance, dispatching, and signal service traffic.
- Provincial/Central Core: Core equipment is deployed at provincial transportation command centers and metro line network centers, connecting to road section aggregation nodes for unified dispatching and management across the entire road/line network.
8.6.3 Core Device Value
- Ring Network High-reliability Bearer: Supports industrial ring network protocols including RRPP and ERPS. In the event of a single node failure on the fiber optic ring, fast switching occurs within 50ms, ensuring uninterrupted services along the route. The ring network architecture saves fiber resources while providing high reliability, suitable for long-distance transportation along-route deployment scenarios.
- Large-traffic Video Bearer: Supports aggregation and forwarding of massive security surveillance video streams, combined with multicast technology for efficient video traffic distribution. Large-bandwidth ports and high forwarding performance meet the bandwidth demands of 4K ultra HD surveillance and intelligent transportation big data transmission.
- Multi-service Unified Bearer: A single device simultaneously carries toll collection, video surveillance, signal dispatching, voice broadcast, office management, and other service types. HQoS enables service-level classification, ensuring low latency and high reliability for critical services such as toll collection and signals, improving network resource utilization.
- Long-term Stable Operation: Carrier-grade reliability design with MTBF ≥800,000 hours, adapting to 7×24 uninterrupted operation requirements of transportation equipment rooms. Wide temperature, dust-proof, and interference-resistant design adapts to harsh deployment environments such as tunnels and outdoor locations.
8.6.4 Deployment Key Points
- Ring network architecture is recommended for long-distance along-route deployment, improving reliability while saving fiber resources.
- Configure independent VPNs and high-priority QoS for critical services to ensure stable operation of toll collection, signals, and other services.
- Outdoor deployment nodes should have equipment protection measures, with industrial-grade equipment and protective cabinets as options.
- Deploy unified video surveillance and network management platforms for visualized management of all network devices and services.
8.7 Education and Healthcare Industry Aggregation Scenarios
8.7.1 University Campus Network Aggregation Scenario
University campus networks have a large number of terminals and rich service types, including teaching, research, office, dormitory, security, and other services. Aggregation layer routers are deployed per building or campus, carrying massive terminal access traffic.
- Network Solution: Access switches are deployed in each teaching building and dormitory building. LA-AR aggregation routers are deployed at building aggregation points with dual-device hot-standby, uplinking to the campus core via 10G fiber. The dormitory area supports PPPoE authentication, while the teaching area supports 802.1X authentication.
- Core Value: High-performance forwarding carries concurrent traffic from massive terminals; supports user authentication and bandwidth control to guarantee bandwidth for teaching and research services; supports IPv6 dual-stack, meeting education network IPv6 deployment requirements; built-in security protection functions defend against common campus network viruses and attacks.
8.7.2 Hospital Private Network Aggregation Scenario
Hospital information systems include core services such as HIS, LIS, PACS, and remote consultation, with high requirements for network reliability and data security. Aggregation layer routers are deployed in inpatient buildings, outpatient buildings, and medical technology buildings, carrying business traffic from various departments.
- Network Solution: Access switches from each department aggregate to building aggregation routers with dual-device redundant deployment, connecting to the hospital core data center. Business systems are divided into independent VLANs and VPNs for security isolation.
- Core Value: High-reliability architecture ensures 7Ă—24 uninterrupted operation of hospital services; priority guarantee for high-bandwidth services such as PACS imaging; low-latency transmission for remote consultation video services; compliant with healthcare industry classified protection requirements, safeguarding patient data security.
8.8 Data Center Access/Aggregation Scenario
8.8.1 Scenario Overview
The access/aggregation layer of small and medium data centers and edge data centers carries access traffic from servers and storage devices, implementing routing and forwarding between server zones and between the data center and the WAN. This scenario has high requirements for high-density high-speed interfaces, large forwarding performance, and virtualization support.
8.8.2 Network Architecture
- Access Layer: Access switches are deployed in server cabinets, connecting servers and storage devices.
- Aggregation Layer: LA-AR high-end aggregation routers are deployed as data center aggregation gateways, carrying access layer traffic and implementing inter-VLAN routing, security policies, load balancing, and other functions. They also serve as the data center egress, connecting to the WAN and the Internet.
- Core Layer: Core switches are deployed in large data centers, with the aggregation layer uplinking to the core layer.
8.8.3 Core Device Value
- High-density High-speed Interfaces: Supports 10GE/25GE access and 100GE uplinks, meeting high-speed server access and large-traffic data exchange requirements.
- Virtualization Support: Supports VXLAN and EVPN, adapting to cloud data center large Layer 2 network requirements and supporting flexible virtual machine migration.
- Security Protection: Built-in firewall and DDoS protection serves as the data center boundary security gateway, securing the internal data center.
- High-reliability Design: Full redundant architecture ensures stable operation of data center services, avoiding network single points of failure.
Chapter 9: Product Installation
9.1 Pre-installation Preparation
9.1.1 Installation Environment Inspection
Before device installation, a comprehensive inspection of the installation site environment must be conducted to ensure the environment meets device operating requirements, avoiding device failure or shortened service life due to environmental issues.
Equipment Room Space Inspection
- Confirm that sufficient space is reserved at the cabinet installation position, with at least 80cm of operating space reserved in front of and behind the device for installation, cabling, and subsequent maintenance;
- Reserve at least 30cm of heat dissipation space above the cabinet to ensure smooth hot air exhaust;
- Confirm that the cabinet is a standard 19-inch rack, with dimensions matching the device, and load-bearing capacity meeting the fully loaded weight requirement of the device (for fully loaded large chassis devices, confirm cabinet load-bearing capacity ≥200kg).
Temperature and Humidity Environment Inspection
- The equipment room operating temperature must be maintained between 0°C–45°C, with optimal operating temperature of 20°C–25°C; avoid placing devices near heat sources, air conditioning vents, or areas with sudden temperature changes;
- The equipment room relative humidity must be maintained between 10%–90% (non-condensing), avoiding internal short circuits caused by humid environments; dehumidification equipment is recommended for high-humidity regions;
- The equipment room must meet dust-proof standards, with no corrosive gases or conductive dust in the air, avoiding dust ingress into the device interior that could affect heat dissipation and component lifespan.
Power Supply Environment Inspection
- Confirm that the equipment room power supply type matches the device power module (AC/DC), with supply voltage within rated range: AC 100-240V, DC -36V~-72V;
- The power supply system must have proper grounding with ground resistance ≤1Ω, avoiding static electricity and lightning damage to equipment;
- It is recommended to connect devices to a UPS uninterruptible power supply to avoid device damage and business interruption from sudden power outages; dual-power devices should be connected to two independent power supply circuits for power supply redundancy.
Electromagnetic Environment Inspection
- Keep devices away from strong electromagnetic interference sources such as high-power motors, transformers, and radar equipment;
- The equipment room electromagnetic environment must comply with GB 9254 standards, avoiding abnormal device operation caused by strong electromagnetic interference.
9.1.2 Equipment and Tool Inspection
Equipment Outbound Inspection
- Verify the device model, configuration, and accessory quantities against the order and packing list, confirming consistency with the order;
- Inspect the device exterior for scratches, paint loss, or deformation; check that interfaces are undamaged and free of foreign objects, and slot covers are intact;
- Verify that the device serial number matches the warranty card, and record the device SN code for subsequent warranty and O&M purposes.
Installation Tool Preparation
- Prepare all tools required for installation, ensuring they are in good working condition. The specific list is as follows:
| Tool Category | Tools |
|---|---|
| Fastening Tools | PH2 cross-head screwdriver, PH1 cross-head screwdriver, flat-head screwdriver, hex key set, adjustable wrench |
| Auxiliary Tools | Anti-static wrist strap, anti-static gloves, spirit level, tape measure, utility knife, cable ties, label paper, marker pen |
| Testing Tools | Multimeter, optical power meter, red light pen (VFL), network cable tester |
| Height Access Tools | Ladder or lifting platform (for high cabinet installation positions), ensuring work-at-height safety |
9.1.3 Safety Precautions
Installation must strictly comply with safety specifications to avoid personal injury and device damage:
- Installers must wear anti-static wrist straps with reliable grounding to avoid static damage to device components;
- Ensure power is disconnected before device installation; hot installation of the host unit and core components is prohibited to prevent electric shock and device short circuits;
- Heavy equipment (such as fully loaded large chassis devices) must be moved by multiple personnel or with dedicated lifting tools, avoiding personal injury and device damage from dropping;
- During installation, tools, screws, and other foreign objects must not be left inside the device chassis to prevent short circuits when powered on;
- Work at height must be performed with safety harnesses, complying with work-at-height safety regulations.
9.2 Rack-mount Installation
All LA-AR series aggregation routers adopt standard 19-inch rack-mount design, recommended for installation in standard server cabinets. This is the most mainstream installation method.
9.2.1 Installing Slide Rails
- Unpack the slide rail packaging and distinguish left from right rails. Rails are marked “L” for left side and “R” for right side;
- Align the rails with the square holes of the cabinet posts, adjust rail length to match cabinet depth, and snap the front hooks of the rails into the square holes of the cabinet posts. Confirm the hooks are fully engaged;
- Secure the rear of the rails to the rear cabinet posts with screws, tightening to ensure the rails are firm and do not wobble;
- After both left and right rails are installed, use a spirit level to check the rails are level, adjusting until perfectly horizontal to prevent device tilting or slipping;
- Slide the inner rails in and out to confirm smooth travel without sticking, and that the locking mechanisms function properly.
9.2.2 Rack-mounting the Device
- Lightweight Devices (box/pod-type, ≤20kg): Two installers work together — one supports the bottom of the device, the other holds the front — aligning the device bottom with the rail channels and pushing smoothly into the cabinet;
- Heavy Devices (large chassis fully loaded, ≥40kg): Use dedicated server lifting tools or four-person coordinated lifting to place the device smoothly onto the rails and push slowly into the cabinet, avoiding impact that could damage the rails or device;
- Push the device in until the front panel is flush with the cabinet posts, confirming the device is fully seated in the rail locking position;
- Use the device’s own fixing screws to secure the left and right mounting ears of the front panel to the cabinet posts, tightening to ensure the device is firm and does not wobble;
- After rack-mounting, re-check the levelness and firmness of the device to confirm stable installation.
9.2.3 Installation Precautions
- The recommended installation height is in the middle of the cabinet, facilitating operation and cabling. Avoid installing at the very bottom of the cabinet (prone to dust accumulation) or the very top (poor heat dissipation);
- The device air intake (front panel) and exhaust (rear panel) must not be blocked; ensure unobstructed airflow paths. Do not pile items in front of or behind the device;
- It is recommended to reserve 1U of heat dissipation space between devices in the cabinet to improve cooling effectiveness;
- The device must be securely fixed. Relying solely on rails without tightening the fixing screws is strictly prohibited, as cabinet vibration could cause the device to slide out.
9.3 Desktop Installation
Small box-type aggregation routers can also be installed on desktops or platforms, suitable for scenarios without cabinets such as small equipment rooms and offices.
- Clean the installation surface, ensuring it is flat, dry, and free of debris, with load-bearing capacity meeting the device weight;
- Attach the rubber feet provided with the device to the four foot positions on the bottom of the chassis, ensuring firm adhesion;
- Place the device steadily on the surface, confirming it is level and does not wobble;
- Reserve at least 10cm of space around the device, and 20cm in front and behind for heat dissipation, ensuring unobstructed airflow. Do not cover device vents;
- Avoid placing the device at the edge of surfaces to prevent falls from impact; avoid stacking other equipment on top.
9.4 Functional Module Installation
The main control boards, service boards, power modules, and fan modules of chassis devices may not be pre-installed at the factory and require on-site installation. Expansion modules and power modules of box-type devices can also be installed as needed. All modular components support hot-swapping, but first-time installation should be performed with power disconnected.
9.4.1 Main Control Board Installation
- Wear an anti-static wrist strap. Remove the main control board from its anti-static packaging, holding the faceplate and board edges. Do not touch chips, components, or gold fingers on the board to avoid static damage;
- Align the board with the main control slot rails in the chassis and insert smoothly, keeping the board level during insertion to avoid tilting that could scratch the backplane connector;
- When the board is nearly fully inserted, turn the ejector lever screws on the board faceplate clockwise to use lever action to fully seat the board into the backplane connector, until the board faceplate is flush with the chassis panel;
- Tighten the fixing screws on the faceplate to firmly secure the main control board to the chassis;
- For dual main control configuration, insert the two main control boards into the active and standby main control slots respectively, using the same installation method.
9.4.2 Service Board Installation
- Remove the blank panel from the corresponding service slot and store it properly. Empty slots must have blank panels reinstalled for dust protection;
- Remove the service board, holding the faceplate and board edges, and insert smoothly along the slot rails;
- Operate the board ejector levers to fully seat the board into the backplane connector. A “click” sound indicates proper seating;
- Tighten the faceplate fixing screws to ensure the board is firmly secured;
- There is no mandatory installation order for service boards, but bottom-to-top installation is recommended for easier cabling. Different types of service boards can be mixed, with slot compatibility details referenced in the corresponding model’s hardware manual.
9.4.3 Power Module Installation
- Remove the blank panel from the power slot and confirm the power slot type matches the power module;
- Holding the power module faceplate, push smoothly along the rails into the power slot. A latch click sound at the bottom indicates proper installation;
- Tighten the fixing screws on the power module faceplate to ensure firm contact;
- For dual power configuration, install the two power modules separately, connecting to two independent power supply circuits;
- After installation, check that the power modules have no looseness and are properly seated, avoiding poor contact that could cause power supply abnormalities.
9.4.4 Fan Module Installation
- Remove the fan module and insert smoothly along the fan slot rails;
- After pushing to the bottom, fasten the faceplate latch to ensure close contact between the fan module and chassis;
- Confirm the fan module is properly installed without looseness;
- Install multiple fan modules in sequence, ensuring all fan slots have modules installed to avoid airflow path short-circuits. Install blank panels in empty slots to maintain proper airflow.
9.4.5 Optical Module Installation
- Remove the optical module from its anti-static packaging and check that the module connector type matches the device slot;
- Remove the dust plug from the optical module, align the module with the interface slot, insert horizontally and smoothly, and listen for a “click” indicating proper seating;
- Gently pull the optical module to confirm it cannot be removed, verifying secure connection;
- Unused optical ports must retain their dust plugs to prevent dust ingress that could affect optical interface performance;
- Optical modules are precision optical devices. Do not bump or drop them, and do not touch the optical interface end faces to avoid contamination and damage.
9.5 Post-installation Inspection
After all components are installed, a comprehensive inspection must be conducted before power-on to confirm correct installation.
- Exterior Inspection: Device is securely installed, level and stable; all modules are properly installed with fixing screws fully tightened; panels are undamaged with no foreign objects fallen into the device interior.
- Airflow Path Inspection: Air intakes and exhausts are unobstructed; all slots have modules or blank panels installed, with complete airflow paths and no short circuits; dust filters are properly installed.
- Cabling Inspection: Power cables and service cables are not yet connected at this point; confirm all interfaces are free of foreign objects and short circuit hazards.
- Grounding Inspection: Confirm the device grounding terminal is reliably connected to the equipment room ground busbar, with grounding resistance meeting requirements.
9.6 Installation Safety Regulations
- All installation operations must be performed by professional technical personnel. Non-professionals are prohibited from disassembling the device or installing modules;
- All operations must be performed with anti-static equipment. Boards and optical modules must not be placed casually after removal; they must be placed on anti-static mats;
- Hot-swapping of main control boards and service boards is prohibited (hot-swap functionality is only for maintenance replacement during normal device operation; first-time installation must be performed with power disconnected);
- If component damage or interface abnormalities are found during installation, stop installation immediately and contact the manufacturer’s technical support for handling. Forced installation is prohibited.
Chapter 10: Product Cabling
After device installation, cable connections are performed. Cable connection quality directly affects device operation stability and service transmission quality. Cabling specifications must be strictly followed. This chapter describes cabling methods and specifications by category: power cables, service cables, management cables, grounding cables, and alarm cables.
10.1 Grounding Cable Connection
Device grounding is a core measure for ensuring equipment safety, static protection, and lightning protection. It must be connected first and the connection must be reliable.
- Grounding Terminal Location: A dedicated grounding terminal is located at the lower left corner of the rear panel of the device chassis, marked with a grounding symbol;
- Grounding Cable Specifications: Use yellow-green dual-color stranded copper grounding cable with cross-sectional area ≥6mm². Length is selected based on on-site grounding distance;
- Connection Steps:
- Use a screwdriver to loosen the fixing screw of the device grounding terminal;
- Insert the lug at one end of the grounding cable into the grounding terminal and tighten the fixing screw, ensuring tight contact without looseness;
- Connect the other end of the grounding cable to the equipment room ground busbar and secure firmly with screws;
- Use a multimeter to measure conductivity between the device chassis and the ground busbar, confirming proper grounding with ground resistance ≤1Ω.
- Precautions:
- Do not connect the grounding cable to non-dedicated ground bodies such as water pipes, heating pipes, or the neutral wire of the mains supply;
- The grounding cable must be firmly connected; loose connections and wrapped connections are prohibited;
- The grounding cable must be continuous without intermediate splices.
10.2 Power Cable Connection
10.2.1 AC Power Cable Connection
- Confirm the device power switch is in the “OFF” position;
- Insert one end of the AC power cable into the power interface of the device power module. After fully inserting, fasten the cable retaining clip (if applicable) to prevent the power cable from coming loose;
- Insert the other end of the power cable into the equipment room PDU power outlet, confirming normal power supply at the outlet;
- For dual-power devices, connect the two power cables to two independent power supply circuits from different distribution cabinets for power supply redundancy;
- After connection, check that power cables are firmly connected without looseness; dress and tie power cables neatly, avoiding blockage of airflow paths and interfaces.
10.2.2 DC Power Cable Connection
DC power cabling requires attention to positive and negative polarity. Reverse connection will damage the device.
- Confirm the equipment room DC power supply switch is in the disconnected (OFF) position;
- DC power typically consists of three cables: -48V (negative), RTN (positive, working ground), and PGND (protective ground);
- Use a screwdriver to open the terminal cover of the power module. Connect cables in sequence according to terminal markings: -48V to negative, RTN to positive, PGND to protective ground;
- Tighten the terminal fixing screws, gently pull cables to confirm no looseness, and install the terminal protective cover;
- Connect the other ends of the cables to the corresponding terminals on the equipment room DC power distribution panel, confirming consistent polarity;
- After connection, use a multimeter to verify input voltage is normal and polarity is correct. Only after confirmation may the switch be closed to supply power.
10.2.3 Power Cable Connection Precautions
- Power cables must comply with national standard specifications. Select appropriate conductor size based on device power rating to avoid overheating from undersized conductors;
- Power cable connections must use crimped cable lugs. Directly twisting bare copper wire onto terminals is prohibited to prevent poor contact and overheating;
- Route power cables away from high-temperature areas and sharp objects to avoid damage and leakage;
- Hot connection of power cables is prohibited; confirm the supply side is de-energized before connection;
- Do not hang heavy objects on power cables or compress power cables.
10.3 Service Cable Connection
Service cables are divided into three categories: Ethernet network cables, fiber optic patch cords, and WAN cables. They serve as the carriers of service data transmission, and connection quality directly affects transmission performance.
10.3.1 Ethernet Electrical Port Connection (RJ45 Network Cable)
- Cable Specifications: Gigabit electrical ports use Cat5e or higher twisted-pair cable, with Cat6 unshielded twisted-pair recommended; shielded twisted-pair cable is used in industrial interference environments;
- Connection Steps:
- Terminate both ends of the RJ45 connectors using T568B wiring standard, and use a network cable tester to verify continuity and absence of crosstalk;
- Insert one end of the network cable into the device Ethernet electrical port, listening for a “click” indicating the connector is latched;
- Insert the other end into the corresponding interface of the peer device (access switch, terminal, etc.);
- After connection, observe the device interface indicator lights. Under normal conditions, a steady green light indicates link connectivity, and a flashing yellow light indicates data transmission.
- Cabling Specifications:
- Network cable transmission distance must not exceed 100 meters; fiber optic transmission is required for longer distances;
- Route network cables away from power cables and electromagnetic interference sources; avoid parallel routing, and use 90-degree crossing when crossing is necessary;
- Network cable bend radius ≥8 times the cable diameter. Sharp bends are prohibited to avoid core damage;
- Apply labels at both ends of network cables, marking the local interface number and the peer device/interface number for subsequent maintenance.
10.3.2 Fiber Optic Interface Connection
- Preparations: Confirm the optical module is correctly installed in the device optical port; prepare fiber optic patch cords of the appropriate specification, confirming the fiber end faces are clean, undamaged, and unbent;
- Connection Steps:
- Remove the dust plug from the optical module and the dust cap from the fiber patch cord to avoid end face contamination;
- Confirm the fiber patch cord connector type matches the optical module (LC/SC, etc.), insert the patch cord smoothly into the optical module interface, and listen for a soft click indicating proper seating;
- Insert the other end of the fiber into the corresponding optical interface of the peer device, noting transmit/receive correspondence: local transmit (TX) connects to peer receive (RX), local receive (RX) connects to peer transmit (TX);
- After connection, observe the optical port indicator. A steady light indicates normal link synchronization. Use an optical power meter to test received optical power, confirming it is between the optical module receive sensitivity and overload power levels.
- Cabling Specifications:
- Fiber bend radius ≥30mm. Sharp bends are prohibited, as excessive bending can cause fiber breakage or severe loss increase;
- Install fiber protection sleeves for fiber routing to avoid crushing and pulling. Route fibers in fiber troughs within cabinets, and never mix with power cables;
- Apply labels at both ends of fibers, marking the link name and local/peer interfaces;
- Cover unused optical ports and fiber connectors with dust caps promptly to prevent dust contamination;
- For long-distance transmission, calculate link loss based on distance, and add optical attenuators when necessary to avoid optical power levels high enough to damage optical modules.
10.3.3 WAN Cable Connection
E1, CPOS, POS, and other WAN cable connections are performed according to the corresponding interface type:
- E1 Coaxial Cable: Use 75Ω coaxial cable with BNC connectors. Align and tighten the connector during connection to ensure good contact. Transmission distance depends on cable specifications, typically not exceeding 300 meters;
- POS Fiber: Connection method is the same as Ethernet fiber. Pay attention to interface rate and protocol matching, confirming consistency with peer parameters.
10.3.4 Link Aggregation Cabling Specifications
For multiple physical links configured for link aggregation, note the following:
- All cables within the same aggregation group must be of identical specifications, identical length, and identical rate to avoid abnormal traffic caused by inconsistent transmission delay;
- Multiple links are recommended to be routed through different physical paths to avoid complete aggregation group failure if a single fiber cable is cut;
- After connection, confirm all member interfaces are UP, and the aggregation group bandwidth is properly accumulated.
10.4 Management and Auxiliary Cable Wiring
10.4.1 Console Configuration Cable Wiring
Used for local device configuration and fault debugging, this is the most fundamental management channel for the device.
The Console cable is an RJ45-to-DB9 serial cable. Insert the RJ45 end into the device’s Console port, and the DB9 end into the serial port of the debugging computer.
If the computer has no serial port, use a USB-to-serial adapter. Install the driver before connecting the Console cable.
After wiring is completed, open serial port software such as Windows HyperTerminal or SecureCRT on the computer. Set the baud rate to 9600, data bits to 8, stop bits to 1, parity to None, and flow control to None. After establishing the serial connection, power on the device, and the command-line interface will be accessible for local configuration management. The Console port is the device’s out-of-band management channel at the underlying layer, independent of the business forwarding plane. Even if the device’s business configuration is corrupted or the management network port is completely disconnected, emergency debugging, password reset, and system recovery can still be performed through this interface. It is the core access method for network engineers conducting on-site operations and maintenance.
10.4.2 MGMT Management Network Port Wiring
The MGMT port is a dedicated out-of-band management Ethernet interface with an independent forwarding plane and hardware resources. Management traffic does not consume business bandwidth, providing higher security and stability. It is primarily used for daily remote Web management, SSH login, SNMP monitoring, system version upgrades, and configuration file transfer.
Use Category 5e or higher standard twisted-pair cable. Insert one end into the RJ45 interface labeled “MGMT” on the device panel, and connect the other end to a dedicated operations and maintenance (O&M) management switch in the equipment room. Physically or logically isolate this from the business network to prevent business network attacks from penetrating the management plane.
During device initialization, configure a dedicated management IP address, subnet mask, and management gateway for the MGMT port. Plan an independent management address segment and prohibit mixing it with business addresses.
It is recommended to configure management access whitelist and access control policies. Only allow designated O&M terminals and network management servers to access the management interface. Disable unnecessary management services to enhance device management security.
After wiring is completed, use the Ping command to test management IP connectivity and confirm the management link is operational. Subsequent device O&M can then be performed remotely without requiring on-site presence.
10.4.3 Dry Contact Alarm Wiring
The device comes standard with a dry contact alarm output interface that can be connected to the equipment room’s power and environment monitoring (PEM) system. This enables centralized audible and visual alarms and remote notification of device faults, allowing O&M personnel to immediately detect device anomalies. It is suitable for unattended equipment room scenarios.
The alarm interface uses a Phoenix terminal block format, including pins for common terminal, power failure alarm, fan failure alarm, over-temperature alarm, and system anomaly alarm. Pin definitions for different models are subject to the hardware manual.
Use RVVP shielded control cable to connect the alarm interface to the environment monitoring system. Connect each alarm pin and the common terminal according to the switch input definitions of the monitoring system.
When wiring, distinguish between Normally Open (NO) and Normally Closed (NC) modes. The Normally Closed mode is recommended, as alarms can still be triggered when the line is disconnected, preventing alarm failure due to line faults.
After wiring is completed, simulate various alarms through the command line to verify that alarm signals are properly uploaded to the environment monitoring platform, ensuring the alarm link is effective.
Alarm cables must be routed separately from high-voltage power cables and kept away from electromagnetic interference sources to prevent false alarms or missed alarms caused by interference.
10.5 Cable Organization and Labeling Standards
After all cables are connected, standardized organization, bundling, and labeling must be performed. This not only improves equipment room tidiness but also significantly reduces the difficulty of later O&M and fault troubleshooting. It is one of the core acceptance items for project delivery.
Classification and Routing Principle: Power cables, business network cables, fiber optic cables, management cables, and alarm cables must be strictly classified, routed, and bundled separately. Mixing them together is prohibited. The spacing between high-voltage and low-voltage cabling must be ≥30cm. When crossing is necessary, use 90-degree perpendicular crossing to avoid electromagnetic interference affecting transmission quality.
Cabinet Routing Standards: Follow the routing principle of “low-voltage on the left, high-voltage on the right; high-voltage below, low-voltage above.” Route power cables along the right-side column of the cabinet and signal cables along the left-side column. Fiber optic cables must be placed in dedicated fiber troughs to avoid compression and stress, with sufficient bending radius reserved at turns.
Bundling Process Requirements: Use nylon cable ties for uniform bundling, maintaining 15-20cm spacing. Tightness should be moderate — cables should not be loose, and the cable sheath should show no compression marks. Cable tie directions must be uniform, excess portions trimmed flush, with no sharp burrs that could scratch O&M personnel.
Labeling Standards: Labels must be affixed to both ends of all cables. Label content should be clear and standardized, including the local device number, interface number, remote device number, interface number, and link number. Labels should be uniformly positioned 2cm from the connector, facing the side that is easy to view, with legible and wear-resistant text.
Redundancy Reservation Requirements: Reserve 30-50cm of redundant cable length inside the cabinet for later maintenance adjustments and port migration. Cables must not be pulled too tight. Fiber optic cables should have appropriate service loop length reserved, with coil diameter ≥6cm, avoiding small-angle bends.
10.6 Pre-Power-On Inspection After Wiring
After all wiring is completed, a comprehensive compliance inspection must be performed before power-on to confirm that the wiring is correct, preventing wiring errors from causing hardware damage or business anomalies.
Power Wiring Inspection: Confirm that power cables are securely connected and plugs are fully inserted. For DC power, use a multimeter to verify positive and negative polarity, confirming there is no reverse polarity risk. Supply voltage must be within the device’s rated range. Grounding must be reliable, with ground resistance ≤1Ω.
Business Cable Inspection: Confirm that all interfaces are fully seated and that cable types match the interfaces. Fiber optic transmit/receive pairs must be correctly matched, with no excessive bending or compression. Network cables must be properly terminated with no short-circuit or open-circuit hazards. All cable labels must be complete and consistent with the planning and design.
Safety Hazard Inspection: No exposed wire ends, no short-circuit hazards. Cables must have no damage or compression. Device ventilation openings must not be blocked, and airflow paths must be unobstructed. No tools, screws, or other foreign objects should be left inside the device or cabinet.
Peer Device Inspection: Confirm that peer device interface parameters are configured to match, with speed, duplex mode, VLAN, and other parameters consistent on both ends. The peer device must be in normal working condition with no faults.
After equipment installation and wiring are completed, the system commissioning phase begins. Commissioning must be strictly executed in accordance with the network planning and design scheme, following the principles of “basics before services, single points before the entire network, verification before cutover.” Implementation should be carried out step by step with item-by-item verification, ensuring that device functions, performance, and reliability all meet design requirements.
11.1 Pre-Commissioning Preparation
11.1.1 Tools and Documentation Preparation
- Commissioning Terminal: 1 laptop PC, pre-installed with serial terminal software such as SecureCRT or PuTTY. Install TFTP/FTP server software for system upgrades and configuration file transfer. Equip with a USB-to-serial adapter for laptops without serial ports.
- Test Instruments: Optical power meter, red light pen (VFL), network cable tester, multimeter, and network traffic tester (optional), used for link performance and device parameter testing.
- Technical Documentation: Project network topology diagram, IP address allocation table, VLAN allocation table, routing allocation table, business configuration templates, security policy list, and this product’s technical manual, ensuring all commissioning operations have a clear basis.
- Credentials and Accounts: Plan device administrator accounts, O&M accounts, and audit accounts in advance, assigning corresponding permissions. Confirm integration parameters for the network management platform and authentication server.
11.1.2 Commissioning Safety Regulations
- The commissioning process must be strictly implemented according to the plan. Random modification of core configurations is prohibited. Unplanned enabling of features is prohibited to avoid triggering network-wide anomalies.
- Before any important configuration modification, the current configuration file must be backed up to ensure rapid rollback in case of configuration errors, minimizing business interruption time.
- Commissioning involving in-service business cutover must be performed during business off-peak hours. A detailed cutover plan and rollback plan must be formulated in advance and reported to relevant supervisors for approval before implementation.
- Maintain complete operation records throughout the commissioning process. All configuration changes, test results, and fault handling must be documented and archived as project acceptance and O&M reference materials.
11.2 Device Power-On and System Initialization
11.2.1 Power-On Startup Process
1. Confirm all wiring inspections have passed and the device front panel power switch is in the “OFF” position.
2. Turn on the cabinet power supply circuit breaker to supply power to the device’s power input side. Use a multimeter to confirm the input voltage is normal.
3. Press the device front panel power switch to the “ON” position. The device begins starting up. The power indicator LED illuminates steady green, and the running LED begins to flash.
4. Observe the startup log through the Console serial port. The device sequentially completes hardware self-test, backplane initialization, line card power-on, system kernel loading, driver initialization, and business module loading.
5. When the command-line login prompt appears after startup, the device has started successfully. Box-type (fixed-configuration) devices take approximately 3-5 minutes to start. Fully loaded large chassis devices take approximately 8-15 minutes to start. The more line cards installed, the longer the startup time.
11.2.2 Post-Startup Hardware Status Verification
After the device starts, verify hardware operating status immediately. Confirm that all components are working normally before proceeding with further configuration.
Indicator Light Verification: Observe the front panel indicator LEDs. Power LED steady green indicates normal power supply. Running LED uniform green flashing indicates normal system operation. Alarm LED off indicates no hardware alarms. When a single component fails, the corresponding alarm LED illuminates.
Line Card Status Verification: View device line card information through the command line. Confirm that the main control board, service boards, power modules, and fan modules are all properly registered with status “Normal.” No components should be offline or in fault status. For dual main control devices, confirm the primary/standby status is correct.
Resource Status Verification: Check device CPU utilization and memory utilization. In idle state, CPU utilization should be below 30% and memory utilization below 50%, with no abnormally high-occupancy processes.
Environmental Status Verification: Check device temperature sensor readings. All chip, interface, and power supply area temperatures must be within rated ranges. Check fan speeds. In intelligent temperature control mode, fans should dynamically adjust with temperature, with no abnormal stoppage.
11.2.3 Basic System Configuration
The first power-on uses factory default configuration. Basic system configuration must be completed first to establish the management channel and system base environment.
Device Naming: Set the hostname according to the project naming convention. The recommended format is “Area-Function-Number,” e.g., “GZ-CORE-AR01,” facilitating identification and management across the entire network.
Account and Permission Configuration: Set the super administrator account and password. Passwords must meet complexity requirements (uppercase + lowercase letters + numbers + special characters, length ≥8 characters). Disable default accounts and weak-password accounts. Create tiered accounts such as O&M and audit accounts as needed, assigning corresponding permissions.
Management Interface Configuration: Configure the MGMT port IP address, subnet mask, and management gateway. Test connectivity with the O&M network. Enable the SSH service, disable the insecure Telnet service, and enable encrypted remote management.
System Time Configuration: Set the system time zone, date, and time. Configure NTP clock synchronization to align with the network-wide unified clock source, ensuring device time is consistent across the network. This provides an accurate time reference for log analysis, fault location, and protocol authentication.
Basic Service Configuration: Enable necessary management services and disable unnecessary system services to minimize the attack surface. Configure device login IP restrictions to enhance management security.
11.2.4 System Version and Configuration Backup
- Check the current system software version and patch version, confirming they match the project requirements. If an upgrade is needed, complete the system version upgrade first before performing business configuration, to avoid configuration loss due to upgrade.
- Back up the factory default configuration and basic configuration separately to both the local computer and the device storage, with clear naming for traceability.
- Configure an automatic device backup policy to periodically back up configuration files to a remote FTP server, preventing configuration loss due to device failure.
11.3 Interface and Link Layer Commissioning
11.3.1 Physical Interface Basic Configuration
- Configure description information for all business interfaces, noting the peer device, interface number, link purpose, and bandwidth level for later O&M identification. Interfaces without descriptions are prohibited.
- Interface speed and duplex mode should use auto-negotiation by default to ensure parameter matching between both ends. When forced configuration is required in special scenarios, the speed and duplex of the local and peer devices must be completely consistent to avoid abnormal states such as half-duplex.
- Enable MDI/MDIX auto-crossover for Ethernet copper ports. Enable flow control as needed. For optical interfaces, enable digital diagnostic monitoring (DDM) and configure optical power alarm thresholds for real-time optical link quality monitoring.
Interface Status Verification: Check the interface physical status and protocol status. Both should be “Up” under normal conditions. If the interface is Down, troubleshoot in the order of “cable → optical module → peer configuration → local hardware.”
11.3.2 Link Aggregation Commissioning
Link aggregation increases link bandwidth and provides link redundancy. It is a common configuration for aggregation layer devices.
- Create an aggregate logical interface. Configure the aggregation mode. LACP dynamic aggregation mode is recommended, as it provides better fault detection capability and compatibility compared to static aggregation.
- Add physical member interfaces to the aggregation group. Ensure all member interfaces have completely consistent speed, duplex mode, VLAN attributes, and link types.
- Configure the load-balancing hash algorithm. Select source/destination IP, source/destination MAC, or five-tuple hashing based on business traffic characteristics, ensuring traffic is evenly distributed across member links.
Function Verification: Check the aggregation group status, confirming all member interfaces are in the Selected state. Verify load-balancing effectiveness through traffic testing. Manually unplug a single link and verify automatic traffic switching with no business interruption.
11.3.3 VLAN and Layer 3 Interface Commissioning
- Create all business VLANs according to the VLAN allocation table. Configure VLAN descriptions corresponding to different departments and business areas.
- Assign interface types: Access-side interfaces are configured in Access mode and assigned to corresponding VLANs. Interconnection-side interfaces are configured in Trunk mode, allowing only planned VLANs to pass through, with Native VLAN configured.
- Create VLANIF Layer 3 logical interfaces, configuring IP addresses and subnet masks as the default gateways for terminals in the corresponding VLANs.
Connectivity Verification: Connect test terminals in the corresponding VLANs, configure IP addresses, and Ping the gateway to verify Layer 2 access and Layer 3 gateway functionality. Test inter-VLAN terminal communication to verify inter-VLAN routing and forwarding.
11.4 Routing Protocol Commissioning
11.4.1 Static Routes and Default Routes
- For fixed network segments and small-scale networks, configure static routes specifying the destination network segment, subnet mask, and next-hop address or outgoing interface.
- As the network egress aggregation device, configure a default static route (0.0.0.0/0) pointing to the upstream egress to enable forwarding for unknown network segments.
- Configure static route association with BFD to improve fault detection speed for static routes.
Verification: View the IP routing table to confirm static routes are correctly generated. Perform cross-subnet Ping tests to verify static route forwarding.
11.4.2 OSPF Dynamic Routing Commissioning
OSPF is the most commonly used interior gateway protocol for enterprise and private networks. Commissioning steps are as follows:
- Enable the OSPF process and configure a globally unique Router ID. The Loopback0 interface address is recommended as the Router ID for higher stability.
- Divide OSPF areas. The backbone area is Area 0. All non-backbone areas must be directly connected to the backbone area. Advertise corresponding interfaces into the designated OSPF areas.
- Configure interface OSPF cost values according to link bandwidth and path selection planning to guide traffic along optimal paths.
Neighbor Verification: Check OSPF neighbor status, confirming neighbor state eventually reaches Full state and that the neighbor relationship is successfully established.
Route Verification: View the OSPF routing table, confirming all network segment routes are correctly learned. Perform end-to-end Ping tests across subnets to verify route forwarding.
Reliability Optimization: Configure OSPF FRR (Fast Reroute) and OSPF-BFD linkage to reduce fault convergence time from seconds to milliseconds.
11.4.3 BGP Protocol Commissioning
BGP is applicable to route interconnection in cross-domain and large-scale networks. Commissioning steps are as follows:
- Configure the BGP process number and local AS number. Configure the BGP Router ID.
- Configure BGP neighbors, specifying the peer IP address and peer AS number. For IBGP neighbors, establishing the session via Loopback interfaces is recommended for improved stability.
- Configure route advertisement policies. Advertise local network segment routes to BGP using the network command or route redistribution.
- Configure route policies to filter and modify attributes for both received and advertised routes, achieving route optimization and traffic control.
Verification: Check BGP neighbor status, confirming the neighbor state is Established. View the BGP routing table, confirming routes are learned correctly. Test end-to-end connectivity across AS network segments.
11.5 Core Business Function Commissioning
11.5.1 QoS Service Quality Commissioning
Traffic Classification: Classify voice, video, production, and office traffic into different priority categories based on service levels using ACLs, DSCP marking, 802.1p, application identification, or other methods.
Traffic Policing: Configure traffic policing on ingress interfaces. Set committed bandwidth and peak bandwidth for each traffic class. Traffic exceeding thresholds should be discarded or re-marked to limit bandwidth consumption by non-critical services.
Queue Scheduling: Configure queue scheduling policies on egress interfaces. High-priority real-time traffic uses SP (Strict Priority) queues to guarantee low latency. Ordinary traffic uses WFQ (Weighted Fair Queuing) to ensure fair bandwidth allocation.
Congestion Avoidance: Configure WRED (Weighted Random Early Detection), setting different drop thresholds based on packet priority to avoid global packet loss caused by queue saturation.
Function Verification: Use a traffic generator to simulate different priority traffic, verifying that high-priority service latency, jitter, and packet loss meet design requirements. Verify key service bandwidth assurance under congestion scenarios.
11.5.2 Security Protection Function Commissioning
ACL Access Control: Configure Layer 2 to Layer 7 ACLs according to security policies, matching traffic requiring control. Apply them in the ingress/egress direction of corresponding interfaces to filter illegal traffic.
Firewall Function: Configure security zones, assigning interfaces for external networks, internal networks, DMZ, and other areas to corresponding security domains. Configure inter-zone security policies for access control based on five-tuple, time, user, and other dimensions.
Attack Defense Configuration: Enable DDoS attack protection for SYN Flood, UDP Flood, ICMP Flood, and other attack types. Configure attack detection thresholds and protection actions. Enable defenses against common attacks such as port scanning and IP spoofing.
Function Verification: Simulate attacks and illegal access using testing tools. Verify that protection policies take effect, legitimate traffic passes normally, and illegal traffic is precisely blocked.
11.5.3 VPN Service Commissioning
Using the most common IPSec site-to-site VPN as an example:
- Configure the interesting traffic ACL, defining the traffic range that requires VPN encrypted transmission. The ACLs on both ends must be mirror-matched.
- Configure IKE security proposals, setting authentication algorithm, encryption algorithm, and DH group. Configure the pre-shared key. Parameters on both ends must be completely consistent.
- Configure IPSec security proposals and security policies, binding the interesting traffic ACL and IKE configuration. Set the encapsulation mode.
- Apply the IPSec security policy on the outbound interface connected to the public network.
Function Verification: Trigger VPN traffic and check the IKE SA and IPSec SA establishment status, confirming the tunnel is successfully established. Perform end-to-end Ping tests across the tunnel to verify encrypted transmission. Check encryption/decryption packet statistics to confirm all traffic is transmitted through the encrypted tunnel.
11.6 High Reliability Function Commissioning
11.6.1 VRRP Virtual Gateway Redundancy
- Two aggregation routers form a VRRP backup group, configured with the same virtual IP address and virtual MAC address, serving as the default gateway for terminals.
- Configure the master device priority higher than the backup device. Enable preemption mode and preemption delay to avoid frequent master/backup switching.
- Configure VRRP linkage with uplink state. When all uplinks are down, automatically lower the master device priority, triggering master/backup switching to avoid business black holes.
Function Verification: Check VRRP status, confirming master/backup roles are correct. Simulate master device failure or uplink interruption, test terminal business interruption time, and verify switching speed meets design requirements.
11.6.2 BFD Fast Detection
- Configure BFD sessions, which can bind to interfaces, static routes, OSPF, VRRP, etc. Configure the minimum detection interval and detection multiplier for millisecond-level fault detection.
- Link BFD with the corresponding protocols. When a fault occurs, BFD detects it rapidly and immediately triggers protocol switching without waiting for the protocol’s own timeout.
Function Verification: Simulate link interruption, check the BFD session Down time, and confirm detection accuracy matches configuration. Verify that linked routes and VRRP switch quickly with significantly reduced convergence time.
11.7 Management and O&M Function Commissioning
11.7.1 Network Management and Monitoring Integration
- Configure the SNMP protocol, setting read/write community strings, SNMP version, and network management server addresses to integrate the device into the unified network management platform.
- Configure Trap alarm reporting to send device fault, threshold violation, and other alarm information in real time to the network management server and O&M email.
- Configure Syslog, sending system logs, operation logs, and security logs to the log server in a graded manner for auditing and traceability.
Function Verification: View device resources, port status, and traffic data on the network management platform, confirming monitoring data accuracy. Trigger test alarms to verify alarm reporting works correctly.
11.7.2 Zero-Touch Provisioning and Automation Verification
- For batch deployment scenarios, verify the ZTP (Zero-Touch Provisioning) function: after device factory reset and power-on, it can automatically obtain an IP address, download configuration, and complete go-live without manual on-site configuration.
- Verify NETCONF/REST API interface availability for integration with automated O&M platforms to enable batch configuration delivery, meeting the automation O&M requirements of large-scale networks.
12.1 Installation Environment Precautions
- The device must be deployed in an indoor, ventilated, and dry environment. Outdoor installation is prohibited. Deployment in humid, water-accumulated, excessive-dust, or corrosive-gas environments is prohibited, as this accelerates component aging and can cause short circuits and corrosion.
- Sufficient heat dissipation space must be reserved at the front and rear of the device. Reserve ≥60cm on the front panel air intake side and ≥80cm on the rear panel air exhaust side. Blocking ventilation openings is prohibited. Stacking items on top of the device or near ventilation openings is prohibited.
- The device must be kept away from strong electromagnetic interference sources such as high-power motors, transformers, and radar. Avoid direct sunlight and direct heat source exposure. Maintain a stable operating environment temperature within the range of 0°C to 45°C.
- For cabinet installation, confirm the load-bearing capacity is sufficient. Heavy chassis-type devices must be installed in the lower portion of the cabinet to maintain cabinet center of gravity stability and prevent cabinet tipping. The cabinet must be securely anchored to the floor.
12.2 Power Supply Safety Precautions
- The device supply voltage must match the rated voltage, and fluctuation must be within the standard allowable range. Long-term operation under overvoltage or undervoltage is prohibited, as this can damage the power supply and core components.
- The device must be reliably grounded with ground resistance ≤1Ω. Operation without grounding is prohibited. The ground wire must not be connected to water pipes, heating pipes, or the mains neutral wire. It must be connected to the dedicated grounding busbar in the equipment room.
- Power wiring must be performed by certified professional electricians. Live wiring is prohibited. Before DC power wiring, positive and negative polarity must be repeatedly confirmed. Reverse polarity connection is strictly prohibited, as it will directly burn out the power supply and device motherboard.
- Avoid frequent power cycling of the device. The interval between switch operations must be ≥30 seconds to prevent power surge damage to components. During normal device operation, do not directly cut off power. First perform a proper shutdown through the command line, then disconnect power.
- In thunderstorm weather, it is recommended to disconnect device power and external fiber optic/network cables to prevent induced lightning damage. In critical scenarios, install surge protectors.
12.3 Operational Usage Precautions
- Back up the current configuration before any configuration modification. For important changes, develop a rollback plan and perform operations during business off-peak hours to avoid business interruption caused by configuration errors.
- Random deletion of system files, modification of kernel parameters, or installation of unauthorized software is prohibited, as this may cause system crashes or failure to boot.
- System version upgrades must use the official release version for the corresponding model. Test versions and customized versions are prohibited. During the upgrade process, power-off and restart are strictly prohibited, as this may prevent the device from booting.
- When inserting or removing optical modules, do not look directly at the optical transmitter end to avoid laser eye injury. When replacing optical modules, remove the fiber first, then remove the optical module.
- Precision components such as line cards and optical modules must not be touched directly by hand on the gold fingers, chips, or optical end faces to prevent electrostatic discharge damage and end-face contamination. Anti-static wrist straps must be worn during operation.
12.4 Daily O&M Precautions
- Regularly clean the device dust filter and equipment room dust. In high-dust environments, clean the dust filter monthly. In ordinary equipment rooms, clean it quarterly. Prevent dust accumulation from blocking airflow paths and causing device overheating.
- Perform daily inspections of device operating status through the network management platform, monitoring CPU, memory, temperature, port traffic, and alarm information. Detect and handle anomalies promptly.
- Regularly back up configuration files and system logs. Back up immediately after important configuration changes. Store backup files in off-site locations to prevent data loss due to device failure.
- During device operation, random hot-swapping of main control boards or service boards is prohibited. Hot-swap operations must strictly follow standard procedures, and confirm the component supports hot-swap before operation.
- Implement access control for the equipment room to prevent unauthorized personnel from accessing devices. Device accounts must be assigned to specific individuals. Account sharing is prohibited. Change passwords regularly.
12.5 Security and Compliance Precautions
- Device deployment and use must comply with the “Cybersecurity Law of the People’s Republic of China,” the “Data Security Law,” and other relevant laws and regulations. The device must not be used for illegal network activities or illegal data transmission.
- Promptly upgrade system security patches and attack signature databases. Conduct regular security vulnerability scans to defend against new types of network attacks.
- Implement cybersecurity classified protection requirements, including boundary protection, access control, log auditing, and data encryption. Conduct regular classified protection evaluations.
- Using the device for network attacks, online fraud, illegal VPN circumvention, or other illegal activities is prohibited. Violators will be held legally accountable.
13.1 Daily Maintenance System
13.1.1 Tiered Maintenance Cycles
Establish a five-tier maintenance system covering daily, weekly, monthly, quarterly, and annual cycles to ensure long-term stable device operation:
Daily Inspection and Maintenance: Perform remote inspection through the network management platform. Check device online status, CPU/memory utilization, temperature, port status, and alarm information. Record operational data and confirm no abnormal alarms.
Weekly On-Site Inspection: Check device indicator LED status on site. Listen for abnormal fan noise. Smell for any burning odors. Check cable connections for looseness or damage. Verify equipment room temperature and humidity are within acceptable ranges.
Monthly Routine Maintenance: Clean device surfaces and cabinet dust. Check dust filter accumulation and clean as needed. Check ground terminals for looseness or oxidation. Test backup link connectivity.
Quarterly Deep Maintenance: Clean dust inside the cabinet. Check power supply and fan operating parameters. Test redundancy switching functions to verify high-availability architecture effectiveness. Verify configuration files and backup validity.
Annual Comprehensive Maintenance: Perform comprehensive hardware testing on the device. Clean line card gold fingers and connectors. Evaluate system versions and upgrade to stable versions as needed. Test ground resistance and power supply quality. Issue an annual O&M report.
13.1.2 Dust Filter Cleaning and Maintenance
The dust filter is the first line of defense for device dust protection and heat dissipation. It is recommended to clean it every 1-3 months. Shorten the cleaning cycle appropriately in dusty, roadside, or industrial environments.
Cleaning Method: Pull the dust filter frame out from the device front panel. Remove the filter media. Rinse with clean water and gently brush away accumulated dust with a soft brush. Allow to air dry completely in a cool, ventilated area before reinstalling.
- Cleaning with alcohol, gasoline, or corrosive cleaning agents is prohibited.
- Exposure to direct sunlight or baking/drying is prohibited, as this may deform the filter media and reduce filtration effectiveness.
- When the dust filter shows damage, aging, or reduced filtration effectiveness, replace it promptly with the original manufacturer’s matching filter.
13.1.3 Optical Interface and Optical Module Maintenance
- Unused optical ports must be fitted with dust caps to prevent dust from contaminating the internal laser and receiver components of the optical interface.
- Quarterly spot checks of optical module optical power are recommended. When abnormal attenuation is detected, promptly clean the fiber end faces and optical interfaces. Use dedicated fiber cleaning pens, lint-free wipes, and anhydrous ethanol for cleaning. Wiping optical end faces with ordinary tissue or fingers is prohibited.
- Avoid excessively frequent insertion/removal of optical modules to prevent connector wear leading to poor contact. Random replacement with different models or different manufacturers’ optical modules is prohibited to avoid compatibility issues.
13.2 Basic Principles of Fault Repair
Software Before Hardware: Fault troubleshooting should first analyze from the configuration, protocol, and system levels. After ruling out software configuration issues, protocol faults, and system bugs, then locate hardware faults. Avoid blindly replacing hardware.
Peripherals Before Device: First troubleshoot peripheral factors such as cables, optical modules, peer devices, power supply, and environment. After confirming the peripheral environment is normal, then locate faults in the local device itself. This reduces unnecessary device disassembly.
Common Causes Before Special Cases: First troubleshoot common causes of global or large-scale faults, then analyze special cases of individual ports or individual services. This improves troubleshooting efficiency.
Recovery Before Investigation: For business interruption faults, prioritize emergency measures to restore business, such as switching to backup links, restarting line cards, or rolling back configurations. After business recovery, conduct in-depth investigation of the root cause to minimize business interruption duration.
Original Manufacturer Repair Principle: Hardware faults should be repaired by original manufacturer certified engineers or returned to the factory for repair. Users are prohibited from disassembling the device or replacing components themselves, as this will void the warranty.
13.3 Common Hardware Fault Repair
13.3.1 Power Module Fault
Fault Symptoms: Power indicator LED not lit, device cannot power on. System reports power fault alarm. In single-power scenarios, the entire device loses power. In dual-power scenarios, the other power module bears the full load.
Troubleshooting Steps:
1. Use a multimeter to measure whether the input power supply is normal.
2. Re-insert the power module, confirming it is fully seated.
3. Cross-swap power module slots to test, ruling out slot faults.
4. Confirm whether the power module fan is running.
Repair Method: After confirming the power module is damaged, purchase the same model of original manufacturer power module for replacement. In dual-power scenarios, hot-swap replacement is supported and can be performed online without business interruption. In single-power scenarios, power off the device before replacement.
13.3.2 Fan Module Fault
Fault Symptoms: Fan alarm LED illuminates, and the system reports a fan fault. Device temperature continues to rise, fan noise is abnormal, or fans stop completely.
Troubleshooting Steps:
1. Check the system fan status to locate the specific faulty fan.
2. Check whether the fan airflow path is blocked by foreign objects.
3. Pull out the fan module and check whether the blades are damaged.
Repair Method: The fan module is a hot-swappable component. Directly pull out the faulty fan module and replace it with an original manufacturer spare fan module. After replacement, the system automatically identifies the new fan and normal operation resumes.
13.3.3 Business Interface Fault
Fault Symptoms: A single interface cannot come Up, and the link is down. Interface is Up but experiences severe packet loss and CRC errors. Interface frequently flaps Up/Down.
Troubleshooting Steps:
1. Replace cables and optical modules to test, ruling out peripheral link issues.
2. Change the port on the peer device to test, ruling out peer device faults.
3. Change to another interface on the local device to test, confirming whether it is a single-interface fault.
Repair Method: For a single interface fault, adjust the plan and use an alternate unused interface as a replacement. If multiple interfaces on the same board fail simultaneously, remove the service board, clean the gold fingers, and reinsert. If the issue persists, replace with the same model of service board.
13.3.4 Service Board Fault
Fault Symptoms: Service board cannot register, status shows fault or offline. All interfaces on the board cannot work. The board restarts frequently.
Troubleshooting Steps:
1. Check system alarm information to confirm the board fault type.
2. Remove the board and check the gold fingers for oxidation or foreign objects. Clean and reinsert for testing.
3. Change slots for testing to rule out slot/backplane faults.
Repair Method: After confirming the board has a hardware fault, replace it with the same model of original manufacturer service board. After importing the original configuration, business is restored.
13.4 System Software Fault Repair
13.4.1 Configuration Loss Recovery
If configuration is lost due to misoperation or failure to save, recover using the previously backed-up configuration file. Import the backup configuration file into the device and restart to apply.
When no valid backup exists, reconfigure according to the network planning documentation. It is recommended to save the configuration promptly after configuration and maintain backups in multiple locations.
13.4.2 System Crash / Cannot Boot
When the device system software is damaged or an upgrade fails causing failure to boot normally, enter BootROM mode through the Console port and reload the system image via a TFTP server.
After system recovery is complete, import the backed-up configuration file and verify business functions are normal.
13.4.3 Software Function Anomalies
For software faults such as process anomalies, function failures, or protocol flapping, first attempt to reset the corresponding function module or restart the corresponding business process.
If the fault cannot be recovered, restart the device or the corresponding service board during business off-peak hours.
For frequently recurring software faults, contact manufacturer technical support to confirm whether it is a known bug. Resolve by upgrading the system version or installing patches.
13.5 Warranty and After-Sales Service Description
Warranty Period: Free warranty for the complete device is 3 years. Core components such as main control boards and service boards have a 5-year warranty. Consumable components such as power supplies and fans have a 1-year warranty. The warranty period is calculated from the device manufacturing date.
Warranty Coverage: During the warranty period, hardware faults caused by non-human damage and non-force majeure events are covered by free repair and replacement services. Software faults are covered by 7Ă—24-hour free remote technical support and version upgrade services.
Non-Warranty Coverage: Human damage, unauthorized disassembly or modification, force majeure damage (flood, fire, lightning, etc.), and faults caused by the use of non-original manufacturer accessories are not covered by the free warranty.
Value-Added Services: Extended warranty services, on-site maintenance services, and advance spare parts services are available for purchase, providing a higher level of after-sales protection and faster fault response.
| No. | Fault Symptom | Possible Causes | Troubleshooting Steps | Solutions |
|---|---|---|---|---|
| 1 | Device has no response when powered on; power LED not lit | 1. External power supply interrupted; 2. Power cable poor contact; 3. Power module damaged; 4. Power switch not turned on; 5. Backplane power supply fault | 1. Measure input voltage with multimeter; 2. Re-insert power cable, confirm secure connection; 3. Test by changing power slot or using spare power supply; 4. Check whether power switch is in ON position; 5. If all power supplies fail, troubleshoot backplane fault | 1. Restore equipment room power; 2. Reconnect power cable; 3. Replace faulty power module; 4. Turn on power switch; 5. Return to factory for backplane repair |
| 2 | Optical interface cannot come Up; indicator LED not lit | 1. Fiber TX/RX reversed; 2. Optical module incompatible or damaged; 3. Fiber link loss too high; 4. Speed/duplex mismatch between ends; 5. Local interface hardware fault | 1. Cross the fiber TX/RX ends to confirm correct connection; 2. Test by replacing with original manufacturer compatible optical module; 3. Test received optical power with power meter, confirm within sensitivity range; 4. Verify interface speed and duplex configuration on both ends; 5. Change slot/interface for cross-validation | 1. Correctly connect fiber TX/RX; 2. Replace with original manufacturer compatible optical module; 3. Repair fiber link, add optical amplifier or replace with low-loss fiber; 4. Unify interface parameters on both ends; 5. Replace faulty interface/service board |
| 3 | Same VLAN communication works; inter-VLAN access fails | 1. VLANIF interface not created or not Up; 2. Terminal gateway configuration incorrect; 3. No route for the destination network segment in routing table; 4. ACL/firewall blocking inter-VLAN traffic; 5. Destination terminal firewall blocking | 1. Check VLANIF status and IP configuration; 2. Check whether terminal gateway address matches VLANIF; 3. View routing table, confirm route to destination network segment exists; 4. Check interface ACLs and security policies; 5. Disable destination terminal local firewall for testing | 1. Correctly configure VLANIF Layer 3 interfaces; 2. Modify terminal gateway configuration; 3. Add corresponding static/dynamic routes; 4. Adjust security policies to allow legitimate traffic; 5. Configure terminal firewall allow rules |
| 4 | OSPF neighbor cannot establish | 1. Interface IPs on both ends not in the same subnet; 2. Area numbers do not match; 3. Router ID conflict; 4. Hello/Dead timers inconsistent; 5. Authentication password mismatch; 6. Netmask inconsistent (broadcast network); 7. Physical link down | 1. Verify interface IP and netmask on both ends; 2. Confirm interface belongs to the same OSPF area; 3. Modify Router ID to ensure network-wide uniqueness; 4. Unify Hello and Dead timer parameters; 5. Confirm OSPF authentication type and password match; 6. Ensure interface netmask matches on broadcast networks; 7. Ping test direct link connectivity | 1. Correct interface IP configuration; 2. Unify area planning; 3. Replace with unique Router ID; 4. Unify protocol parameters; 5. Configure consistent authentication information; 6. Adjust netmask for consistency; 7. Repair physical link |
| 5 | IPSec VPN tunnel establishment fails | 1. Interesting traffic ACL mismatch; 2. IKE/IPSec proposal parameters inconsistent; 3. Pre-shared key mismatch; 4. Public network link down; 5. Intermediate firewall blocking IKE/ESP packets; 6. Abnormal NAT environment on local/peer end | 1. Verify ACLs on both ends, ensure mirror symmetry; 2. Verify encryption, authentication, and DH group parameters are completely consistent; 3. Confirm pre-shared key case and characters match exactly; 4. Ping peer public address to verify connectivity; 5. Check intermediate firewall allows UDP 500/4500 and ESP protocol; 6. Configure NAT traversal | 1. Modify ACLs for symmetric matching; 2. Unify security proposal parameters; 3. Configure consistent pre-shared key; 4. Repair public network connectivity; 5. Allow corresponding ports and protocols; 6. Enable NAT-T traversal |
| 6 | Device CPU utilization persistently too high | 1. DDoS attack or port scanning causing excessive CPU-bound packets; 2. Route flapping causing frequent protocol calculations; 3. Excessive management packets from logging, network management, etc.; 4. Business specifications exceeding device performance limits; 5. Abnormal system processes | 1. Check processes with high CPU usage to identify the specific cause; 2. Check whether routing table changes frequently; 3. Check attack defense statistics for large numbers of attack packets; 4. Verify whether business specifications exceed device parameters; 5. Check system process status | 1. Configure attack defense policies to filter abnormal packets; 2. Investigate root cause of route flapping, stabilize network topology; 3. Optimize logging and network management configuration; 4. Expand device capacity or optimize business configuration; 5. Restart abnormal processes or upgrade system |
| 7 | Severe network packet loss; business lag | 1. Link bandwidth saturated with congestion; 2. Abnormal optical power causing bit errors and packet loss; 3. Poor network cable quality or electromagnetic interference; 4. Unreasonable QoS configuration, no guarantee for key services; 5. Device forwarding resources exhausted | 1. Check port traffic statistics, confirm bandwidth utilization; 2. Check interface error and packet loss statistics, test optical power; 3. Replace with shielded cable, keep away from high-voltage interference; 4. Check queue drop statistics, optimize QoS policy; 5. Check device resource utilization | 1. Expand link bandwidth, optimize traffic scheduling; 2. Clean fiber end faces, replace faulty optical modules/fibers; 3. Replace with compliant cable, optimize cabling; 4. Adjust QoS to guarantee key business bandwidth; 5. Expand device performance |
| 8 | Device temperature alarm; fans at high speed with loud noise | 1. Equipment room ambient temperature too high; 2. Dust filter blocked, airflow path restricted; 3. Individual fan failure reducing cooling capacity; 4. Device running at full load with high heat generation; 5. Chip thermal grease aging | 1. Check equipment room air conditioning and ambient temperature; 2. Check dust filter accumulation; 3. Check fan status, confirm whether any fan is faulty; 4. Check device load and traffic; 5. For long-running devices, check cooling efficiency | 1. Turn on air conditioning, lower equipment room temperature; 2. Clean or replace dust filter; 3. Replace faulty fan module; 4. Optimize services to reduce device load; 5. Return to factory for reapplication of thermal grease |
| 9 | Cannot remotely manage device via SSH/Web | 1. Management network down; 2. Remote management service not enabled; 3. Incorrect username/password or insufficient permissions; 4. ACL blocking management IP access; 5. Management plane CPU congestion | 1. Ping device management IP to verify connectivity; 2. Log in via Console port to check service status; 3. Confirm username, password, and permissions; 4. Check management interface access control list; 5. Check management plane CPU utilization | 1. Repair management network connectivity; 2. Enable SSH/Web management services; 3. Reset account password and permissions; 4. Adjust ACL to allow management addresses; 5. Investigate cause of high CPU usage |
| 10 | VRRP master/backup frequent switching flapping | 1. Unstable uplink with frequent flapping; 2. VRRP timers or authentication mismatch between ends; 3. Link congestion causing VRRP packet loss; 4. Device CPU too high to process packets in time | 1. Check uplink status and error statistics; 2. Verify VRRP timer parameters and authentication configuration on both ends; 3. Check link bandwidth and congestion; 4. Check device CPU and protocol process status | 1. Repair unstable uplink; 2. Unify VRRP parameters on both ends; 3. Expand link capacity or optimize QoS; 4. Resolve high CPU usage issue |
15.1 Basic Knowledge FAQs
Q1: What are the specific differences between aggregation layer routers, core routers, and access layer switches?
A: The three types of equipment differ significantly in their positioning and core capabilities within the three-layer network architecture:
- Access Layer Switches: Closest to end terminals, focused on high-density port access, primarily performing Layer 2 switching functions. They feature simple functionality, dense port distribution, and low cost, and are responsible for terminal network access and VLAN partitioning.
- Aggregation Layer Routers: Serve as the intermediate node connecting the upper and lower layers, focusing on access traffic aggregation, inter-VLAN routing, policy enforcement, and multi-service processing. They balance forwarding performance with service capabilities and act as the network’s policy enforcement center.
- Core Routers: Positioned at the top tier of the network, focused on high-speed non-blocking forwarding. They deliver extremely high performance and high interface rates, with cross-regional traffic scheduling as the core function. Service features are relatively streamlined, prioritizing maximum forwarding performance and reliability.
Q2: Does the LA-AR series aggregation router fully support IPv6? Can it meet IPv6 migration requirements?
A: The entire product series natively supports IPv4/IPv6 dual-stack, covering all service features including OSPFv3, BGP4+, IPv6 ACL, IPv6 QoS, IPv6 VPN, and IPv6 firewall. It also supports multiple IPv6 transition technologies including dual-stack, 6PE, DS-Lite, and NAT66. It fully meets the IPv6 upgrade and migration requirements for government, enterprise, and other scenarios, enabling smooth evolution.
Q3: Does the product meet Xinchuang (domestic IT innovation) requirements? Can it be used for government and classified networks?
A: The LA-AR Xinchuang series achieves full-stack domestic localization of both hardware and software. Core components use 100% domestic solutions, equipped with the independently controllable LA-OS operating system and a built-in national cryptography hardware encryption engine. It has passed authoritative certifications from the National Administration of State Secrets Protection, the Ministry of Public Security, and the State Cryptography Administration, and is included in the Xinchuang product catalog. It is fully suitable for Xinchuang migration and classified network construction in key industries such as government, finance, and energy.
15.2 Installation & Deployment FAQs
Q4: Which components of the equipment support hot-swapping? What precautions should be taken during operation?
A: Power modules, fan modules, service line cards, and main control boards of mid-to-high-end chassis devices all support hot-swapping and can be replaced online without service interruption. For box-type (desktop) devices, power modules and fan modules support hot-swapping; expansion cards depend on the specific model specifications.
Hot-swap operation precautions:
- Must wear an anti-static wrist strap
- Operate smoothly and steadily; avoid violent shaking
- Insert and remove slowly; never force the components
- When replacing a main control board, confirm the primary/backup status and only remove/insert the backup main control board
Q5: Must original factory optical modules be used? What impact do third-party optical modules have?
A: Original factory-matched optical modules are strongly recommended. Original modules undergo full compatibility testing and high/low-temperature aging tests, offering stable performance and matched parameters, and are eligible for complete warranty coverage. Third-party optical modules may cause issues such as failure to be recognized, unstable performance, significant temperature drift, and high bit error rates. Equipment failures caused by third-party optical modules are not covered under warranty.
Q6: Can the device be wall-mounted or installed upside down?
A: No. The device uses a front-to-back airflow design, and component layout has gravity orientation requirements. Inverted or wall-mounted installation will disrupt the cooling airflow path, sharply reducing cooling efficiency and causing overheating failures, while also affecting line card connection reliability. The device must be installed upright in a rack or placed horizontally on a desktop to ensure correct airflow direction.
15.3 Configuration & Operations FAQs
Q7: What should be done if the administrator password is forgotten? Will the configuration be lost?
A: The administrator password can be reset by entering BootROM mode via the Console port and using the official password recovery function. This operation does not result in the loss of existing configuration files. For high-security-level models, an enterprise authorization certificate must be provided, and the operation is guided by technical support. It is recommended to properly store passwords, change them regularly, and maintain archived records.
Q8: Will system upgrades cause service interruption?
A: Mid-to-high-end chassis devices support ISSU (In-Service Software Upgrade) without service interruption. During the upgrade, the forwarding plane continues to operate with smooth primary/backup switching, resulting in zero-perceived service interruption. Entry-level box-type devices require a system restart for upgrades, which may cause brief service interruption; it is recommended to perform such upgrades during off-peak hours. Configuration files and system images must be backed up before any upgrade.
Q9: Will the routing table capacity be insufficient? What specification does an ordinary enterprise need?
A: Different models offer routing table capacities ranging from 16K to 4M entries. For ordinary enterprise campus and government private network scenarios, the number of routing entries is typically within a few thousand, which entry-level and mid-range models fully satisfy. For carrier internet egress and large-scale private networks, high-end models with large routing tables should be selected to accommodate full BGP routes across the network.
15.4 Troubleshooting FAQs
Q10: What causes configuration loss after device restart? How can this be avoided?
A: The vast majority of configuration loss cases result from failing to execute the save command after modifying configuration, causing the device to revert to the last saved configuration upon restart. In rare cases, the configuration file is corrupted, or an incorrect configuration file is loaded at startup.
Preventive measures:
- After configuration changes are confirmed effective, immediately execute the save command
- Regularly back up configuration files to external storage
- Configure automatic configuration backup policies
Q11: The optical interface is Up but packet loss is severe — what should be checked first?
A: Prioritize checking optical link quality:
1. Use an optical power meter to test the received optical power, confirming it falls between the optical module’s receive sensitivity and overload power
2. If the power is too low, check whether the fiber end face is contaminated, the fiber is excessively bent, or connectors are loose
3. If the power is too high, add an optical attenuator to prevent optical module saturation
4. After ruling out link issues, check optical module compatibility and interface hardware faults
15.5 Warranty & Service FAQs
Q12: How long is the warranty period? What situations are excluded from warranty coverage?
A: The complete device carries a 3-year free warranty, core components are covered for 5 years, and consumable parts for 1 year. The following situations are not covered by the free warranty: man-made damage, unauthorized disassembly or modification, water damage/lightning strikes or other force majeure damage, failures caused by the use of non-original accessories, and out-of-warranty equipment. Software issues receive lifetime remote technical support.
Q13: How quickly can hardware failures be resolved? Is there an expedited response service?
A: Software issues can be resolved in real time remotely via the 7×24-hour technical hotline. Hardware failures can be resolved with same-day spare part replacement to restore service when spare parts are available. Factory repairs typically take 7–15 working days. Core customers can purchase advance spare parts service and on-site service, with priority dispatch of backup equipment after failures to ensure rapid service recovery.
Chapter 16 Product Acceptance
After equipment installation and commissioning are completed, both parties (Party A and Party B) jointly conduct project acceptance. Upon successful acceptance, the equipment is formally delivered and enters the warranty/maintenance period. Acceptance work must be objective, standardized, and verified item by item to ensure that equipment performance and functionality fully meet contract and design requirements.
16.1 Acceptance Basis and Standards
- Project procurement contract, technical specification documents, and bidding/tender documents
- Project networking design plans, IP/VLAN/routing planning tables, and service configuration plans
- National and industry standards:
- YD/T 1097-2019 “Technical Requirements for Router Equipment — High-end Routers”
- GB/T 30094-2013 “Technical Specification for Industrial Ethernet Switches”
- GB/T 21671-2018 “Test and Evaluation Specification for LAN Systems Based on Ethernet Technology”
- GB/T 22239-2019 “Information Security Technology — Baseline for Classified Protection of Cybersecurity”
- Factory inspection standards and technical manuals of this product
16.2 Appearance and Installation Acceptance
Visual Inspection: The equipment is intact and undamaged, free from scratches, paint loss, or deformation. Panel labels and markings are clear and complete, and serial numbers match the contract.
Installation Workmanship Inspection: Equipment is securely and correctly installed, leveled to specification, with all mounting screws present. Rack layout is reasonable and complies with the overall data center arrangement.
Cabling Acceptance: Cables are classified, neatly bundled, and clearly labeled. Fiber optic, network, and power cables are laid out in compliance with standards, without compression or excessive bending. Rack cable routing is clean with reasonable redundant slack.
Grounding and Power Inspection: Equipment grounding is reliable with ground resistance ≤ 1 Ω. Dual-power devices are connected to two independent power supply circuits, with supply voltage stable within the rated range.
16.3 Hardware and Reliability Acceptance
Component Completeness Acceptance: Verify against the contract configuration list that all components — including main control boards, service cards, power supplies, fans, and optical modules — match in model, quantity, and version. All components are properly registered and operational without faults or alarms.
Indicator and Status Acceptance: All indicators display normally without fault alarms persistently lit. System operating status, resource utilization, and temperature parameters are all within the normal range.
Redundancy Function Acceptance:
- Power Redundancy: Removing a single power supply keeps the device running normally with no service interruption
- Fan Redundancy: Simulating a single fan failure keeps device temperature normal without over-temperature alarms
- Main Control Redundancy: Primary/backup main control board switchover test achieves zero service interruption, with switchover time meeting rated specifications
- Link Redundancy: Disconnecting a single link automatically switches traffic with no service awareness
Environmental Stability Acceptance: The device runs continuously at full load for 2 hours; temperatures in all device zones are tested and remain within the rated operating temperature range without over-temperature alarms.
16.4 Interface and Link Performance Acceptance
Interface Status Acceptance: All planned service interfaces are Up without abnormal Down ports. Interface statistics show no error packets, damaged packets, or dropped packets, with a bit error rate of 0.
Link Quality Acceptance:
- Copper Ports: Network cable tester verifies correct wire sequence with no crosstalk or open circuits; Gigabit port throughput meets specifications
- Optical Ports: Optical power meter tests transmit and receive power, both within the optical module’s normal operating range; link loss meets design values
- Throughput Testing: Professional traffic generator performs full-port throughput testing, achieving wire-speed forwarding with zero packet loss; both long-frame and short-frame tests meet performance metrics
Link Aggregation Acceptance: All members of the aggregation group operate normally with even traffic load distribution. Single-link failure switchover time ≤ 50 ms with no service interruption.
16.5 Function and Service Acceptance
16.5.1 Routing Function Acceptance
- Static routes, OSPF, BGP and other protocols operate normally with stable neighbor relationships, complete route learning, and routing tables consistent with planning
- Route convergence time test: Route convergence time after link failure meets technical specifications
- Routing policies and policy-based routing functions take effect, with traffic paths consistent with planned expectations
16.5.2 Service Function Acceptance
- VLAN Function: VLAN partitioning is correct, isolation effects meet requirements, and inter-VLAN routing forwarding operates normally
- QoS Function: Scheduling of different priority services is normal; bandwidth, latency, and packet loss for critical services meet design requirements
- Security Function: ACL, firewall, and anti-attack policies take effect; illegal access and attack traffic are precisely blocked
- VPN Function: VPN tunnels are stably established, encrypted transmission operates normally, and cross-VPN service access meets permission requirements
16.5.3 High Availability Acceptance
- VRRP gateway switchover is normal with switchover time meeting specifications; terminal services show no significant interruption
- BFD fast detection and coordination functions operate normally; fault detection accuracy meets configuration requirements
- Both device failure failover and link failure failover meet business continuity requirements
16.6 Management and Operations Acceptance
Management Method Acceptance: CLI command-line, Web graphical, SSH, SNMP and other management methods all operate normally with complete functionality.
Monitoring and Alarm Acceptance: Device resource, port traffic, and operating status monitoring data are accurate. Alarms are correctly reported to the network management platform with clear classification and timely reporting.
Log Audit Acceptance: System logs, operation logs, and security logs are completely recorded and can be exported to log servers normally, meeting audit requirements.
Account Permission Acceptance: Multi-level user permission controls are effective, with permission partitioning meeting security management requirements.
16.7 72-Hour Stability Test
After all functional acceptance tests pass, a 72-hour full-load continuous operation stability test is conducted. During the test period, the following requirements apply:
- No abnormal restarts, power failures, or hardware fault alarms
- Service traffic forwarding is stable without abnormal packet loss, latency increases, or interruptions
- CPU, memory, and temperature remain stable without abnormal spikes or severe fluctuations
- Routing neighbors and VPN tunnels remain stable without flapping or interruption
- No abnormal system logs or alarm messages
Passing the 72-hour continuous operation test without anomalies constitutes successful stability testing.
16.8 Acceptance Documentation Delivery
Upon successful acceptance, complete project documentation is delivered to the user. Both parties sign and stamp to confirm acceptance, and the project is formally delivered. Delivered documentation includes:
- Project acceptance report with acceptance items, test data, and acceptance conclusions
- Device final configuration files, system version information, and account permission tables
- Performance test reports, functional test records, and 72-hour stability test records
- Product manuals, warranty cards, certificates of conformity, and original factory quality certifications
- Operations and maintenance manuals, routine inspection guides, and troubleshooting handbooks
SEO Keyword System and Optimization Tags
I. Search Keyword Classification
1. Core Primary Keywords
Aggregation layer router, aggregation router, campus network aggregation router, enterprise-level aggregation router
2. High-Conversion Long-Tail Keywords
Aggregation layer router installation and commissioning, aggregation layer router wiring tutorial, aggregation layer router configuration manual, aggregation layer router manufacturer, aggregation layer router price, aggregation layer router selection, aggregation layer router brand recommendation, domestic aggregation layer router, Xinchuang aggregation router, industrial-grade aggregation router
3. Industry Traffic Keywords
Enterprise campus network aggregation equipment, government private network aggregation router, financial private network aggregation router, electric power private network aggregation router, carrier metro network aggregation router, data center aggregation router, campus network aggregation router, hospital private network aggregation router
4. Brand-Specific Keywords
Lain aggregation layer router, Guangdong Lain aggregation router, LA-AR series aggregation router, Lain intelligent network equipment, Lain data center network equipment
5. Dropdown/Related Search Keywords
Function of aggregation layer router, difference between aggregation layer router and core router, aggregation layer router working principle, aggregation layer router technical parameters, aggregation layer router common faults, how to configure aggregation layer router, aggregation layer router installation steps
II. SEO Optimization Tag System
1. Core Page Optimization Tags
- Page Topic: Aggregation Layer Router Installation, Wiring, and Commissioning Manual
- Core Positioning: Full lifecycle technical guide for aggregation layer routers, covering product introduction, installation, wiring, commissioning, operations, and troubleshooting
- Target Audience: Network engineers, operations and maintenance personnel, system integrators, data center construction teams, enterprise IT departments
2. Title Tag
Aggregation Layer Router Installation Wiring Commissioning Manual_Product Parameters_Fault Troubleshooting – Guangdong Lain Smart Data Center
3. Meta Keywords
Aggregation layer router, aggregation router installation and commissioning, aggregation router wiring tutorial, aggregation layer router configuration manual, domestic aggregation router, Xinchuang aggregation router, Lain aggregation router, LA-AR series router
4. Meta Description
Guangdong Lain Smart Data Center officially provides the complete LA-AR series aggregation layer router installation, wiring, and commissioning manual, covering product introduction, technical parameters, installation steps, wiring specifications, commissioning processes, common fault troubleshooting, operations and maintenance, and project acceptance — a full-dimension technical guide. Enterprise-grade, carrier-grade, and Xinchuang series aggregation routers suitable for campus networks, government, finance, electric power, and carrier scenarios.
5. H1 Tag
Aggregation Layer Router Installation Wiring Commissioning Manual
6. H2 Tags
Product Introduction, Product Composition, Product Classification, Product List, Product Working Principle, Product Technical Parameters, Product Functions and Features, Product Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Product Precautions, Product Repair and Maintenance, Product Common Problems and Solutions, Product FAQ, Product Acceptance
III. Internal Link Optimization Tags (Natural Anchor Text Placement)
1. Core Anchor Text
Aggregation layer router, aggregation router installation and commissioning, aggregation router technical parameters
2. Long-Tail Anchor Text
Aggregation layer router common fault resolution, aggregation layer router acceptance standards, Xinchuang aggregation router manufacturer, industrial-grade aggregation router applications
3. Related Anchor Text
Access layer switch, core layer router, micro-module cold aisle, data center power and environment monitoring, network security equipment
Copyright Notice
This document is copyrighted by Guangdong Lain Smart Data Center Equipment Co., Ltd. and protected by the Copyright Law of the People’s Republic of China. Without prior written authorization from the company, no individual or organization may reproduce, redistribute, excerpt, alter, or commercially disseminate all or part of this document in any form.
For reprinting or citation of this document, the source must be credited as “Official Document of Guangdong Lain Smart Data Center Equipment Co., Ltd.,” and the content must not be abridged, modified, or used in a distorted manner.
Should the content of this document undergo technical updates or version iterations, no separate notice will be provided. Please refer to the company’s official website for the latest official version.
The company assumes no legal liability for any direct or indirect losses resulting from improper use of this document.