Data Center Container Room | Modular Container Data Center – KITOZER

Product Overview

The Data Center Container Room is a high-grade prefabricated data center product developed by KITOZER (Guangzhou Lain Intelligent System Development Co., Ltd.) for medium to large-scale computing load demands. Using standard containers as modules, it integrates high-density racks, redundant power distribution, precision cooling, intelligent management, and fire safety systems. It supports both independent single-cabin deployment and flexible multi-cabin expansion, enabling rapid construction of T3/T4 standard data center computing clusters. The entire process is factory-prefabricated and delivered on-site with only water and power connections needed for operation, significantly shortening the data center construction cycle. It is a mainstream choice for enterprise data centers, intelligent computing centers, and disaster recovery centers.

Product Introduction

The Data Center Container Room is a prefabricated, modular data center solution that comes as a fully integrated container unit. Each unit is built with high-density IT racks, redundant power and cooling, DCIM monitoring, and fire protection. It is designed for rapid deployment and can be used as a standalone facility or linked together to form larger clusters. KITOZER offers models ranging from 5kW to 20kW per rack, supporting T3 to T4 availability levels, ensuring high reliability for mission-critical operations.

Product Positioning

Positioned as a professional-grade prefabricated data center product for medium to high-density computing loads, it serves internet, government, finance, and computing service providers. It replaces traditional brick-and-mortar data centers by offering rapid deployment, elastic scaling, and energy-efficient standardized solutions, meeting requirements for server hosting, cloud computing, AI training, and disaster recovery.

Core Value

Rapid Deployment

Shortens construction time by 60%-80% compared to traditional data centers. From order to production in as little as 3 months, quickly responding to computing expansion needs.

Elastic Scalability

Modular cabin design supports phased deployment. When business grows, new cabins can be quickly added, avoiding large upfront investments and resource idle.

Energy Efficiency

Closed cold aisle and high-efficiency precision cooling achieve PUE as low as 1.25, significantly reducing long-term energy costs.

Reliability

Strict compliance with data center design standards, supports N+1/2N redundancy, availability above 99.99%, ensuring business continuity.

Product Highlights

  • Supports 10-20 high-density racks per cabin, with per-rack power from 5 to 20kW, meeting high-performance equipment demands.
  • Fully redundant system architecture – power, cooling, and network all have redundant configurations, eliminating single points of failure.
  • Intelligent DCIM platform provides full visualization of all data center elements, improving operations efficiency by over 50%.
  • Multi-cabin expansion enables rapid construction of clusters with over 100 racks.

Product Classification and Composition

Classification

By power density: Standard Density (5kW/rack), Medium Density (10kW/rack), High Density (20kW/rack). By availability: T3 redundant, T4 fault-tolerant. By deployment: single cabin, multi-cabin cluster.

System Composition

A data center container room consists of eight core systems:

  • Container Structure System: Reinforced steel container, including thermal insulation, anti-seismic reinforcement, waterproof sealing.
  • Power Supply and Distribution System: HV/LV switchgear, modular UPS, battery banks, precision distribution cabinet, busway, lightning protection and grounding.
  • Cooling and Temperature Control System: Row-based precision air conditioners, closed cold aisle, free cooling unit, intelligent temperature control.
  • Rack and Cabling System: High-density server racks, power and data cabling, fiber optic distribution, smart PDU.
  • Fire and Security System: Very early smoke detection, FM200/IG541 gas suppression, video surveillance, access control, perimeter protection.
  • DCIM Management System: Data center infrastructure management platform, energy management, capacity management, alarm management.
  • Fresh Air and Exhaust System: High-efficiency fresh air units, air filters, positive pressure maintenance.
  • Auxiliary Systems: Lighting, emergency escape devices, maintenance access, tool storage.

System Working Principle

The data center container room uses standardized cabin units, with subsystems working together to create a reliable computing environment:

  • Power System: Dual incoming power feeds, modular UPS, and battery banks achieve 2N redundancy for zero downtime. Intelligent distribution monitors loads in real-time for precise energy management.
  • Cooling System: Closed cold aisle architecture – cold air supplied from the front of racks, hot air exhausted from the back; row-based precision cooling combined with free cooling uses outside cold air in winter, reducing energy consumption.
  • Fire Suppression: Very early smoke detection provides pre-warning. Upon alarm, non-fire power is cut off and gas suppression activates without damaging equipment.
  • DCIM System: Collects all data from power, cooling, security, and environment. 3D visualization displays operational status, supports intelligent alarms, capacity prediction, energy analysis, and smart O&M.

Technical Specifications

The following table shows key specifications for different models:

Item Standard Density (20ft) Medium Density (40ft) High Density (40ft)
—— ————————- ———————– ———————
External Dimensions (L×W×H) 6058×2438×3100mm 12192×2438×3100mm 12192×2438×3300mm
Container Material Q235B reinforced steel Q235B reinforced steel Q235B reinforced steel
Protection Rating IP54 IP54 IP54
Floor Loading 1000kg/㎡ 1200kg/㎡ 1500kg/㎡
Number of Racks 8×42U high-density 16×42U high-density 18×42U high-density
Per-Rack Power 5kW 10kW 20kW
Total IT Load 40kW 160kW 360kW
Power Architecture N+1 redundant 2N redundant 2N redundant
UPS Capacity 60kVA modular 200kVA modular 400kVA modular
Backup Time 15min/30min optional 15min/30min optional 15min/30min optional
Cooling Method Row-based precision AC + closed cold aisle Row-based precision AC + closed cold aisle Row-based precision AC + closed cold aisle + free cooling
Design PUE ≤1.4 ≤1.3 ≤1.25
Operating Temperature -30℃~+45℃ -30℃~+45℃ -30℃~+45℃
Fire Suppression FM200 gas IG541 gas IG541 gas
Availability Level T3 T3+ T4
Design Life ≥25 years ≥25 years ≥25 years

Product Configuration List

No. Product Name Specification Qty Unit Brand Remark
—– ————— ————— —– —— ——- ——–
1 Container Cabin Reinforced steel, composite insulation, waterproof sealing 1 Set KITOZER Includes structural reinforcement and anti-corrosion
2 High-Density Server Rack 42U, 600×1200×2000mm, load 1500kg 8-18 Unit KITOZER Configured per model
3 Modular UPS Online double-conversion, modular redundancy 1-2 Set First-line brand Per capacity
4 Battery Bank VRLA or lithium optional 1-2 Group First-line brand Backup time optional
5 Precision Distribution Cabinet/Power Distribution Unit Smart monitoring, branch measurement 1-2 Unit KITOZER Includes lightning protection
6 Row-Based Precision AC Constant temp/humidity, inverter energy-saving 2-6 Unit First-line brand Per cooling capacity
7 Closed Cold Aisle System Tempered glass doors, top flip skylight 1 Set KITOZER Linked to fire system
8 DCIM Management System 3D visualization, full monitoring 1 Set KITOZER Includes server and software
9 Gas Suppression System FM200/IG541 piping network 1 Set National standard brand Includes very early smoke detector
10 Security System Access control, HD surveillance, perimeter protection 1 Set National standard brand Includes storage
11 Structured Cabling System Busway, cable tray, fiber distribution, smart PDU 1 Set KITOZER Per rack quantity
12 Fresh Air & Lighting System High-efficiency fresh air, LED lighting, emergency lighting 1 Set National standard brand Includes air filter

Core Advantages

Material Advantage

The mainframe uses thickened H-beam steel welded construction; side panels are 2mm quality cold-rolled steel, overall seismic rating of 8 degrees. Insulation layer uses A-class fireproof polyurethane insulation board, 80mm thick with low thermal conductivity, preventing thermal bridges. Surface uses heavy-duty fluorocarbon spray system for excellent weather and corrosion resistance, suitable for long-term outdoor deployment. Internal racks use 1.5mm quality cold-rolled steel, static load up to 1500kg, meeting high-density equipment requirements.

Craftsmanship Advantage

High-precision CNC machining ensures dimensional accuracy within ±1.5mm, guaranteeing sealing for multi-cabin splicing. Full welding + flaw detection process ensures structural strength. Internal installation follows GB50174 (Code for Design of Data Centers) with separate power and data cabling. Before delivery, 48-hour full-load simulation tests verify redundancy switching, temperature control precision, and alarm response.

Customization Advantage

Supports full-scenario customization from single cabin to cluster. Flexible adjustment of rack quantity, power density, redundancy level. Advanced customization includes diesel generator, photovoltaic storage, liquid cooling retrofit. Exterior, internal layout, and management platform can be tailored. Compatible with different brand equipment to meet brand preference and existing asset reuse.

Cost Advantage

Factory prefabrication reduces construction and management costs by over 30% compared to traditional data centers. Modular deployment allows investment based on need, avoiding idle resources. Energy-efficient design reduces long-term electricity costs, resulting in lower total cost of ownership (TCO).

Quality Advantage

Strict adherence to national data center design standards and industry norms. Core components from first-line international and domestic brands. Certified ISO9001, ISO27001, etc. Products pass fire, lightning, EMC tests. Each unit has a complete quality file with full traceability; factory pass rate 100%.

Materials and Craft Analysis

Detailed Materials

  • Main Structural Steel: Q355B low-alloy high-strength steel, yield strength ≥355MPa, 40% stronger than ordinary steel, ensuring structural stability under high-density loads.
  • Insulation Material: 80mm polyurethane sandwich panel, core density ≥45kg/m³, fire rating B1/A optional, thermal conductivity ≤0.024W/(m·K).
  • Surface Anti-corrosion: Epoxy zinc-rich primer with zinc content ≥85%; epoxy micaceous iron oxide intermediate coat; high weather-resistant fluorocarbon topcoat; total film thickness ≥200μm; salt spray test ≥1500 hours.
  • Racks and Auxiliaries: SPCC quality cold-rolled steel, electrostatic spraying; copper busbars with low temperature rise; EPDM foam sealing strips for waterproofing and dust resistance.

Core Craftsmanship

  • Cabin Forming: Laser cutting, CNC bending, robotic welding frame, post-weld annealing to relieve stress, ensuring long-term no deformation and precision for multi-cabin splicing.
  • Anti-corrosion Spraying: Fully automatic spraying line with degreasing, phosphating, passivation before spraying primer, intermediate, and topcoat; each layer’s thickness is checked.
  • System Integration: Modular partition assembly, electrical and cooling systems constructed simultaneously, strict separation of power and data cabling. Layered cable trays with shielding to reduce EMI.
  • Factory Testing: Simulated load test platform; 30+ performance tests including full-load temperature rise, redundancy switching, fire drill, extreme environment simulation. Comprehensive delivery test report provided.

Safety Certifications

  • China Compulsory Product Certification (CCC)
  • ISO9001 Quality Management System
  • ISO27001 Information Security Management System
  • ISO14001 Environmental Management System
  • Fire Product Type Inspection Certification
  • Lightning Protection Device Test Report
  • Electromagnetic Compatibility Test Report
  • Structural Strength and Seismic Test Report

Stock Availability

We maintain stock of 40ft standard density data center container rooms. Standard configurations can ship within 10 days. Other models can be scheduled quickly with delivery far below industry average. All stock units have completed factory full-function testing and include complete technical documentation and acceptance materials for immediate use. Stock quantities are updated in real-time; contact our sales team for details.

OEM/ODM Services

We provide professional OEM/ODM manufacturing for data center container rooms, including brand labeling, customized solution development, and dedicated production scheduling.

Confidentiality: Strict NDA signed. Client plans, technical data, and project information are classified and managed. Independent production areas to prevent leakage. No KITOZER branding on OEM products, protecting client’s brand rights.

Manufacturing Capability: Full chain from structural design, container processing, system integration, testing, and delivery. Supports client-representative supervision and progress updates.

Quality Standard: OEM products follow identical quality control and testing procedures as our own brand, ensuring consistent quality.

Product Attributes (SKU)

SKU Code Product Name Model Rack Qty Total Power Remark
———- ————— ——- ———- ————- ——–
LA-JZX-SJ-20S Data Center Container Room (20ft Standard) KITOZER-SJ20-S 8 40kW T3, N+1
LA-JZX-SJ-40M Data Center Container Room (40ft Medium) KITOZER-SJ40-M 16 160kW T3+, 2N
LA-JZX-SJ-40H Data Center Container Room (40ft High) KITOZER-SJ40-H 18 360kW T4, 2N
LA-JZX-SJ-QZ Data Center Container Room (Cluster Custom) KITOZER-SJ-QZ Custom Custom Multi-cabin splicing

Application Scenarios

  • Internet Industry: Cloud computing nodes, edge data centers, CDN nodes, AI computing clusters.
  • Financial Industry: Disaster recovery data centers, branch computer rooms, document storage.
  • Government & Enterprises: Government cloud data centers, municipal big data centers, state-owned enterprise HQs.
  • Telecom Operators: 5G core rooms, transmission hub rooms, cloud resource pool nodes.
  • Energy Industry: Power dispatch data centers, energy big data centers, oilfield computing centers.
  • Education & Research: University supercomputing centers, research institute computing rooms, training data centers.

Customization Services

Customization Scope

  • Architecture: Redundancy level, power density, liquid cooling solutions.
  • Scale: Single cabin size, multi-cabin cluster, function cabins (generator, battery, O&M).
  • Function: PV storage integration, diesel generator, intelligent O&M robot, liquid cooling retrofit.
  • Management: DCIM platform features, third-party system integration, custom O&M interface.
  • Appearance: Corporate painting, brand logo, special exterior design.

Customization Process

  1. Requirement research: Technical team investigates computing needs, deployment environment, availability requirements.
  2. Proposal: Customized design plan, equipment list, quotation, and delivery schedule.
  3. Confirmation: Both parties discuss and finalize design and commercial terms.
  4. Contract: Sign contract, deposit payment, start production.
  5. Production control: Dedicated team tracks progress, updates client, supports on-site inspection.
  6. Delivery & Acceptance: Factory pre-acceptance, shipping, on-site installation and commissioning, final acceptance.

Customization Advantages

  • Experienced design team with T3/T4 data center design expertise.
  • Flexible production system balances personalization and delivery speed.
  • Rich case studies across finance, government, internet, energy.
  • Full warranty and after-sales support; lifecycle technical assistance.

Success Cases

Notable Clients

Top cloud service provider, a provincial branch of a state-owned bank, a municipal government big data bureau, a provincial telecom operator, and a new energy group.

Project Highlights

  • Government Cloud Project: Deployed 4-cabin cluster for a municipal cloud with 64 racks, T3+ standard, 2N redundant power and cooling. From start to acceptance in just 3 months – 6 months earlier than traditional construction. PUE steady at 1.28, awarded green data center demonstration project.
  • Computing Node Cluster: Deployed 12-cabin high-density cluster for a cloud provider, 15kW per rack, total IT load over 2800kW. Used free cooling and inverter technology, annual PUE as low as 1.23. Phased deployment matched business growth, reducing upfront investment.

Procurement Service Guarantees

Supply Guarantee

Large self-owned production base with multiple specialized lines ensures ample capacity. Standard models are in stock for fast shipment. Bulk orders are scheduled to meet contract deadlines, no delays.

Quality Guarantee

Full quality control with multiple inspection points from raw materials to finished product. Core components from first-line brands. Warranty of 1-3 years on entire unit, extendable for core parts. Acceptance documentation provided to support customer’s verification.

Logistics Guarantee

Professional large-item logistics partners, nationwide delivery with insurance. Customized packaging to prevent damage. Delivery to site with lifting and positioning guidance.

After-Sales Guarantee

7×24-hour hotline, 1-hour response for critical faults. Engineer visit within 24 hours (provincial) and 48 hours (nationwide). Regular inspection services. Lifetime technical support; parts and repair at cost after warranty.

Invoice Guarantee

Can issue 13% VAT special invoice, progress-based billing. Regular and verifiable, supporting financial deduction. Can be sent with goods or separately.

Contact: Mr. Zhou 13538869979 (WeChat same), 13538869979 (WeChat same)

Address: Zhongrun Industrial Park, Chaotian District, No.5 Huashan Road, Shilou Town, Panyu District, Guangzhou

Troubleshooting

Failure Symptom Possible Cause Solution
—————– —————- ———-
Single mains outage, no auto transfer Transfer switch fault, UPS bypass abnormal Check UPS auto transfer status, manually switch to backup; inspect switch mechanism, contact after-sales
Local rack overheat Corresponding AC fault, cold aisle seal fail, load spike Check row AC, repair seal, reduce load temporarily, contact after-sales
DCIM data abnormal Acquisition module fault, network interruption, software issue Check module power and communication, restore network, restart service, contact technical
Fire alarm triggered Real fire, false alarm, system fault Immediately verify on site; if real fire, start emergency plan; if false, reset and clean detector; contact maintenance
Access control failure Power outage, controller fault, permission issue Check power, use mechanical key, restart controller, re-issue permissions, contact after-sales

Maintenance

Daily

  • Check system status via DCIM for any alarms.
  • Monitor energy data, record PUE and loads.
  • Inspect surrounding environment for safety.

Monthly

  • Inspect cold aisle sealing, clean AC filters and air intakes.
  • Check UPS parameters, battery voltage and internal resistance.
  • Test fire system pressure, check detector status.
  • Check door access, CCTV, alarms, clean camera lenses.
  • Tighten key electrical connections, check for overheating.

Quarterly

  • Clean internal dust, racks, and cable trays.
  • Routine AC maintenance: check refrigerant pressure, fan bearings.
  • Test UPS battery discharge, evaluate health.
  • Check grounding system, measure earth resistance.
  • Conduct fire system linkage test.

Annual

  • Deep clean entire system including evaporators, condensers, electrical cabinets.
  • Battery capacity test, replace failed batteries.
  • AC deep maintenance, replace consumables, calibrate temperature control.
  • Comprehensive electrical inspection with infrared thermography.
  • Full fire system inspection, replace expired agent and consumables.
  • Cabin anti-corrosion check, touch-up paint.
  • DCIM system upgrade, backup configs and historical data.

Factory Capability and After-Sales Service

Factory Capability

We have a dedicated prefabricated data center production base with advanced CNC equipment, automated spraying lines, and system integration test platforms. Core technical team includes data center designers, electrical engineers, cooling engineers, and software engineers with T4-level design and integration experience. Annual capacity reaches hundreds of container data centers, meeting large-scale cluster delivery requirements.

After-Sales Service System

Three-level after-sales system with professional O&M engineers:

  • Remote Support Center: 7×24-hour on-duty for remote troubleshooting, technical consultation, configuration guidance.
  • Regional Service Stations: Strategic locations for quick on-site response.
  • Expert Technical Team: Handles complex faults, system optimization, upgrades.

Free patrol inspections during warranty, fault repair, and technical training. Post-warranty annual maintenance contracts available.

FAQ

Q: Can container data centers achieve T4 level?

A: Yes, our high-density model uses 2N fully redundant architecture with no single point of failure for power, cooling, and network, meeting T4 availability standards.

Q: Will multi-cabin splicing have water leakage or sealing issues?

A: No. High-precision machining and multiple sealing structures at joints, plus water-tight tests before delivery. On-site water spray validation ensures sealing performance.

Q: Can PUE really reach 1.25?

A: High-density models with free cooling technology can achieve annual PUE as low as 1.25 in northern regions; southern regions can also be controlled below 1.3. Actual values depend on local climate and load factor.

Q: Can you provide data center O&M services?

A: Yes, we offer professional O&M outsourcing including regular inspections, fault handling, and system optimization. Choose per your needs.

Q: Do you provide acceptance documents after project delivery?

A: Yes, we provide complete as-built documentation including product certificates, test reports, construction drawings, operation manuals, test reports, etc., supporting project acceptance.

Conclusion

The Data Center Container Room, with its rapid deployment, elastic scalability, and energy efficiency, is becoming the mainstream choice for data center construction. Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER) has years of experience in prefabricated data centers. With professional design, reliable quality, and comprehensive service, we provide high-reliability, cost-effective containerized data center solutions to help clients quickly realize their computing business and efficient operations.