KITOZER Data Center Fire Alarm Linkage & Gas Suppression System Quotation List
Applicable Scope: Computer Room Fire Protection Linkage Integration Project (120㎡ Protection Zone)
Table of Contents


2. Project Requirement Description
This solution is designed for a 120㎡ computer room protection zone. The system adopts a cabinet-type HFC-227ea (Heptafluoropropane) clean gas fire suppression system with an independent fire detection and alarm system, delivering dual detection via smoke and heat sensors. The system supports three activation modes — automatic, manual, and mechanical emergency start.
Specifically, the system must meet the following requirements:
- Provide smoke detection and heat detection dual-channel fire alarm confirmation
- Support automatic activation, manual activation, and mechanical emergency activation modes
- Integrate with the computer room environment & power monitoring (EPMS) system and power distribution system
- Automatically trigger audible & visual alarms, delayed agent discharge, and cutting of non-fire power supply upon fire confirmation
- Eliminate the need for water pipe networks, with zero residue after discharge and no damage to precision electronic equipment
3. System Composition Introduction
The Computer Room Fire Alarm Linkage Integration System consists of three core modules:
- Fire Detection & Alarm System — photoelectric smoke detectors, point-type heat detectors, fire alarm controllers, audible & visual alarm devices
- HFC-227ea Gas Suppression System — cabinet-type gas extinguishing devices, HFC-227ea agent, automatic pressure relief vents, gas discharge indicator lights
- Fire Linkage Control System — gas extinguishing controller, linkage modules, emergency start/stop buttons, dedicated fire alarm cabling
The complete system is composed of gas extinguishing controllers, photoelectric smoke detectors, heat detectors, audible & visual alarm devices, gas discharge indicator lights, emergency start/stop buttons, cabinet-type extinguishing devices, automatic pressure relief vents, linkage modules, together with pipework, auxiliary materials, installation and commissioning services.
4. Core Product Specifications & Parameters
4.1 Cabinet-Type HFC-227ea Fire Extinguishing Device
- Model: KZR-QM-90
- Single-unit volume: 90L
- Working pressure: 2.5MPa
- Filling density: ≤1150kg/m³
- Discharge time: ≤10s
- Construction: 1.5mm thick steel plate, electrostatic powder-coated
- Includes HFC-227ea agent cylinder, container valve, pressure gauge, and nozzle
- Pipe-network-free design, wall-mountable, complies with GB 50370
4.2 Gas Extinguishing Controller
- Model: KZR-XF-KZ
- Wall-mounted installation, supports 2 protection zones
- Control modes: automatic, manual, emergency
- Adjustable delay: 0–30s
- Standard configuration: 8 detection loops, 4 linkage output channels
- RS485 communication interface for uploading alarm and activation signals to EPMS platform
4.3 Photoelectric Smoke Detector
- Model: KZR-SD-YG
- Scattered-light photoelectric sensing principle
- Operating voltage: DC24V
- Alarm current: ≤2mA
- Sensitivity: 3-level adjustable
- Dust-proof and insect-proof design
- Operating temperature: -10°C ~ +55°C
- Complies with GB 4715
4.4 Point-Type Heat Detector
- Model: KZR-SD-WG
- Combined fixed-temperature + rate-of-rise detection
- Operating voltage: DC24V
- Alarm temperature: 60°C
- Rate-of-rise trigger: 7.5°C/min
- Auto-reset function
- Ingress protection: IP30
- Complies with GB 4716
4.5 Automatic Pressure Relief Vent
- Model: KZR-XY-012
- Mechanical gravity-type pressure relief vent
- Effective relief area: 0.12㎡
- Activation pressure: 1000±100Pa
- Material: galvanized steel plate
- Wall-mounted at upper position of protection zone exterior
- Auto-reset after pressure release
5. Core Functions & Features of Products
- Dual Detection & Alarm Function: Smoke detector + heat detector dual-detector combination. Single detector triggers pre-alarm; dual detector confirmation triggers fire alarm, effectively reducing false alarm probability.
- Multi-Mode Suppression Function: Supports automatic delayed discharge, on-site manual emergency start/stop, and mechanical emergency activation — suitable for different response scenarios.
- Full-Process Linkage Function: After fire confirmation, the system automatically activates on-site audible & visual alarms, closes ventilation and air conditioning, cuts non-fire power supply, and starts gas extinguishing devices — fully automated response.
- Status Feedback Function: Alarm, activation, and fault status of all devices can be uploaded to the EPMS platform for remote real-time monitoring of fire system operation.
- Personnel Safety Assurance: Audible & visual pre-warning and delayed countdown before discharge, equipped with emergency start/stop buttons, ensuring safe evacuation of on-site personnel.
6. Core Advantages of The Solution
- Clean & Residue-Free: HFC-227ea agent has excellent dielectric properties, rapidly vaporizes after discharge with zero residue — non-corrosive, non-contaminating to electronic equipment, no post-fire cleanup required.
- Fast Suppression Speed: Full-flooding discharge completes within 10 seconds, rapidly extinguishing incipient electrical fires and preventing fire spread.
- Easy Installation: Cabinet-type device requires no pipe network or dedicated cylinder room, occupies minimal floor space, can be installed directly inside the computer room — ideal for small and medium-sized room retrofit projects.
- High Reliability: All core components passed national fire product 3C certification; system MTBF (Mean Time Between Failures) ≥50,000 hours; stable and reliable in standby mode year-round.
- Strong Linkage Compatibility: Standard communication protocols enable rapid integration with EPMS, building management, and power distribution third-party systems — achieving integrated fire protection management.
7. Manufacturer Strength Introduction
KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.) is a professional intelligent system development and manufacturing enterprise:
- Founded in 2002, with over 20 years of industry experience
- ISO 9001 quality management system certified
- ISO 14001 environmental management system certified
- ISO 45001 occupational health & safety management system certified
- Recognized as a national high-tech enterprise
- All fire protection products passed national fire product 3C certification and type inspection
- Project-confirmed manufacturing with complete quality inspection before shipment
- Professional fire protection design and construction team
- Dedicated gas suppression system test bench; every unit undergoes rigorous air-tightness and discharge performance testing prior to shipment
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Cabinet-Type HFC-227ea Fire Extinguishing Device | KZR-QM-90 | 90L volume, 2.5MPa working pressure, incl. container valve, pressure gauge, nozzle | 4 | Set | 3,551.87 | 14,207.48 | KITOZER | Empty cabinet, excl. agent |
| 2 | HFC-227ea Fire Suppressant Agent | KZR-YJ-HFC | Purity ≥99.9%, eco-friendly HFC-227ea agent | 360 | kg | 66.60 | 23,976.00 | KITOZER | Quantity calculated per actual protection zone |
| 3 | Gas Extinguishing Controller | KZR-XF-KZ | Dual protection zone control, auto/manual/emergency modes, RS485 communication | 1 | Unit | 1,109.96 | 1,109.96 | KITOZER | Wall-mounted, incl. power supply & backup battery |
| 4 | Photoelectric Smoke Detector | KZR-SD-YG | Photoelectric type, DC24V, 3C certified, adjustable sensitivity | 12 | Pcs | 39.96 | 479.52 | KITOZER | Incl. base & dust cover |
| 5 | Point-Type Heat Detector | KZR-SD-WG | Fixed-temp + rate-of-rise composite, 60°C alarm, DC24V | 12 | Pcs | 35.52 | 426.24 | KITOZER | Incl. base |
| 6 | Fire Audible & Visual Alarm Device | KZR-SG-24V | DC24V, sound level ≥110dB, flashing strobe, 3C certified | 4 | Pcs | 53.28 | 213.12 | KITOZER | Wall-mounted |
| 7 | Gas Discharge Indicator Light | KZR-SF-LED | Red flashing, “Gas Discharge – Do Not Enter” sign, DC24V | 4 | Pcs | 31.08 | 124.32 | KITOZER | Installed outside door |
| 8 | Emergency Start/Stop Button | KZR-QT-AN | With protective cover, manual start/stop control, key reset | 4 | Pcs | 44.40 | 177.60 | KITOZER | Wall-mounted, anti-misoperation design |
| 9 | Automatic Pressure Relief Vent | KZR-XY-012 | 0.12㎡ effective area, gravity type, 1000Pa activation | 2 | Pcs | 244.19 | 488.38 | KITOZER | Galvanized steel plate material |
| 10 | Fire Linkage Module | KZR-LD-4 | 4-channel I/O module, DC24V, dry contact output | 2 | Set | 177.60 | 355.20 | KITOZER | For integration with power distribution & HVAC systems |
| 11 | Fire-Rated Cable | KZR-XL-RVS | RVS 2×1.5mm² fire-rated twisted pair, flame-retardant & fire-resistant | 600 | m | 1.33 | 798.00 | KITOZER | Detection & control wiring |
| 12 | Galvanized Conduit | KZR-GG-20 | Φ20mm galvanized conduit, 1.2mm wall thickness | 300 | m | 1.78 | 534.00 | KITOZER | Incl. conduit clips, elbows, connectors |
| 13 | Installation & Commissioning Service | KZR-SG-XF | Fire system installation, cabling, commissioning, linkage testing, acceptance documentation | 1 | Item | 2,664.00 | 2,664.00 | KITOZER | Incl. labor, tools, auxiliary materials |
Total Quotation Price: USD 45,553.82
9. Quotation Terms & Conditions
1. Currency: All prices quoted in US Dollars (USD).
2. Price Basis: EXW Guangzhou, China (or as negotiated).
3. Tax: Prices exclude tax and freight. A 10% surcharge applies for VAT special invoice; a 3% surcharge applies for VAT general invoice.
4. Freight: Products shipped via logistics; freight is collect (payable by receiver). Unloading at destination is the responsibility of the buyer.
5. Payment Terms: 30% deposit and 70% balance before shipment (negotiable).
6. Lead Time: 15–30 working days depending on configuration and order quantity.
7. Validity: This quotation is valid for 30 days from the date of issue.
8. Packing & Shipping: Packing and shipping costs are quoted separately upon request.
9. Warranty: System equipment — 2 years; fire suppressant agent — 5 years. Free repair or replacement for non-artificial damage.
10. After-sales Service Description
KITOZER provides comprehensive after-sales support:
- Warranty Coverage: 12–24 months warranty per product (system equipment 2 years; fire suppressant agent 5 years), covering non-artificial damage
- Lifetime Technical Support: Free technical consultation and system operation guidance for the lifetime of the product
- Spare Parts Availability: Long-term guaranteed supply of genuine spare parts for all products
- Remote Troubleshooting: Rapid remote diagnosis and resolution of system faults via phone, email, or video support
- On-Site Service: Professional engineering team available for on-site inspection, maintenance, annual testing, agent refilling, and system upgrade services
- Annual Inspection Support: Complete acceptance documentation and annual inspection assistance to meet regulatory compliance requirements
11. Contact & Order Information
To place an order or request further information, please contact the KITOZER sales team:
- Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Smart Computer Room Equipment Co., Ltd.
- Brand: KITOZER
- Contact Person: Mr. Zhou
- Phone/WeChat: +86-135-0923-8849
- Address: Chongtian Park, Huashan Road No. 5, Shilou Town, Panyu District, Guangzhou, China
- Order Channel: Official website gdlain.com or direct contact with the KITOZER sales team
- Response Time: All inquiries receive a response within 24 hours
12. SEO Keywords & Tags
KITOZER quotation, computer room fire alarm linkage integration price list, HFC-227ea gas suppression system quotation, cabinet-type gas extinguishing device price, data center fire protection system cost, computer room Qiqiang propane fire suppression, fire alarm linkage control solution, clean agent fire suppression system factory price, KITOZER computer room fire protection, gas extinguishing device 3C certified quotation, computer room fire protection system wholesale price, KITOZER data center fire protection quotation