Table of Contents
ToggleProduct Overview
KITOZER’s data center overall construction integration is a full-stack, one-stop solution for all types of data center scenarios. It covers design, equipment supply, construction, commissioning, and O&M delivery for all subsystems including decoration, power distribution, UPS, precision cooling, gas fire suppression, security access control, environment monitoring, structured cabling, and cold aisle containment. From raw space to standardized, operational data center, we deliver complete turnkey projects that meet the infrastructure needs of data storage, network switching, and server operation.
Product Positioning
Positioned as a core product for mid-to-high-end data center construction in government, finance, healthcare, education, telecom, and industrial manufacturing, this integration service provides turnkey contractor services compliant with GB 50174-2017 (Code for Design of Data Centers) for A, B, and C grade levels. It adapts to all scale requirements from small office computer rooms to large cloud data centers, serving as a one-stop delivery vehicle for data center infrastructure construction.
Core Value
- One-stop delivery: unified design, unified construction, unified acceptance, eliminating multi-supplier coordination costs.
- Standardized compliance: all systems follow unified technical standards, ensuring compatibility and interlocking.
- Controllable schedule: modular construction + parallel operations significantly shorten overall construction time.
- Risk mitigation: single responsible entity clarifies quality and maintenance responsibilities, reducing project risk.
- Full lifecycle support: from initial planning to post-construction maintenance, we provide technical services throughout the entire lifecycle.
Product Highlights
- Full system coordination: power, cooling, fire protection, and monitoring systems are interlocked to improve overall reliability.
- Modular architecture: standardized modules allow for easy expansion and upgrade later.
- Strong compliance: strictly follows national data center construction standards, meeting MLPS and classified protection requirements.
- Energy optimization: efficient cooling and intelligent power distribution reduce PUE.
- Visualized management: bundled environment monitoring platform provides full-status visualization of the data center.
Product Classification and Composition
Product Classification
- By grade: A-grade data center overall integration, B-grade enterprise computer room integration, C-grade basic computer room integration.
- By application: government/enterprise core computer room, medical information computer room, campus network computer room, industrial control computer room, shielded computer room integration, edge computing site integration.
- By scale: micro computer room (≤20㎡), small computer room (20-100㎡), medium computer room (100-500㎡), large data center (>500㎡).
System Composition
- Decoration system: ceiling, wall, anti-static floor treatment, partitions, doors and windows.
- Power supply and distribution: high-voltage distribution, low-voltage distribution, distribution cabinets, busways, lightning protection and grounding.
- UPS system: UPS host, battery bank, battery cabinet, power distribution modules.
- Cooling and fresh air: precision air conditioner, row-based cooling, fresh air blower, exhaust equipment, air ducts.
- Fire protection: gas fire extinguishing equipment, smoke/heat detectors, fire alarm controller, emergency lighting.
- Security system: video surveillance, access control, intrusion alarm, electronic patrol.
- Environment monitoring: environment monitoring, power monitoring, security integration, alarm management platform.
- Cabinet and aisle system: server racks, network racks, cold aisle containment, cable management.
- Structured cabling: fiber optic cabling, copper cabling, patch panels, cable organizers.
System Principle
The overall integration is designed with core principles of high availability, high reliability, high energy efficiency, and scalability, strictly following national and industry standards for unified architecture planning. By systematically integrating the five dimensions of space, power, cooling, security, and monitoring, each subsystem is adapted via standardized interfaces, removing compatibility barriers. A centralized management platform enables unified collection and interlocking dispatch of power, environment, security, and fire protection data. When anomalies such as power failures, temperature/humidity exceedances, or fire alarms occur, the corresponding system’s emergency response mechanism is automatically triggered, ensuring continuous stable operation and supporting uninterrupted upper-layer business systems.
Technical Specifications
| Parameter | Technical Indicator | Remarks |
| — | — | — |
| Applicable grade | A/B/C | Compliant with GB 50174-2017 |
| Power supply reliability | A: 99.995%; B: 99.99%; C: 99.9% | Corresponding annual downtime |
| Cooling accuracy | Temperature ±0.5°C, humidity ±3%RH | Precision air conditioning area |
| Monitoring response time | ≤3s | Alarm upload to platform |
| Fire response time | ≤10s | From fire detection to gas discharge |
| Grounding resistance | ≤1Ω | Combined grounding system |
| Anti-static performance | Surface resistance 10⁶~10⁹Ω | Anti-static floor/wall |
| MTBF | ≥100,000h | Core systems |
| Construction period | Micro: 15 days / Small: 30 days / Medium: 60 days / Large: customized | Excluding preliminary approvals |
Product Configuration List
| No. | Product Name | Specifications | Unit | Qty | Remarks |
| — | — | — | — | — | — |
| 1 | Server Rack | 600×1200×2000mm, 42U, front/rear mesh doors | Unit | As required | Standard |
| 2 | UPS | 10-200kVA, online double conversion | Set | As required | 3/3 or 3/1 configurable |
| 3 | VRLA Battery | 12V/100Ah, maintenance-free | Cell | As required | Backup duration optional |
| 4 | Precision AC | 5-100kW, constant temp/humidity, up/down airflow | Unit | As required | N+1 redundancy |
| 5 | Anti-static Floor | 600×600×35mm, full steel, edge | ㎡ | As required | Load ≥1000kg/㎡ |
| 6 | Color Steel Sandwich Panel | 50mm thick, fireproof class A | ㎡ | As required | Wall decoration |
| 7 | Heptafluoropropane System | Cabinet/piped, custom designed | Set | As required | 3C certified |
| 8 | Monitoring Host | Embedded architecture, multi-protocol | Unit | 1 | Standard |
| 9 | Structured Cabling | Cat6 UTP / 10G fiber, as required | Point | As required | Brand optional |
| 10 | Lightning Protection & Grounding | B+C class, combined grounding grid | Set | 1 | Standard |
Materials & Process Analysis
Material Details
- Wall material: A-grade fireproof color steel sandwich panel with rock wool core, 0.6mm galvanized steel surface, electrostatic spray coating, fireproof, moisture-proof, dust-proof, anti-static.
- Floor material: full steel anti-static floor, steel plate thickness ≥1.2mm, filled with foamed cement, high-wear anti-static PVC surface, strong load capacity, long service life.
- Power distribution material: main busbars use T2 copper, tinned, excellent conductivity; cables are low-smoke halogen-free flame-retardant, compliant with fire safety requirements.
- Cooling material: copper pipes for AC, closed-cell rubber insulation, low thermal conductivity, anti-condensation.
- Fire suppression material: heptafluoropropane (FM200), clean, environmentally friendly, no damage to equipment, high efficiency.
Core Process Description
- Modular construction: prefabricated components, on-site assembly, reduces on-site work, improves efficiency and quality consistency.
- Dust-free construction: dust-free operation during renovation, thorough cleaning before equipment installation to prevent dust impact.
- Sealing process: fire-resistant sealant used for doors, windows, and pipe penetrations, ensuring air tightness and fire compartment integrity.
- Grounding process: combined grounding network, equipotential bonding, ground resistance ≤1Ω, ensuring equipment and personnel safety.
- Welding process: copper connections use tin-plating, firm welding, low contact resistance, avoiding overheating hazards.
Safety Certifications
- ISO 9001 Quality Management System
- ISO 14001 Environmental Management System
- ISO 45001 Occupational Health and Safety
- 3C Compulsory Certification for fire products
- ROHS Certification
- Electronic and Intelligent Engineering Professional Contracting Qualification
Core Advantages
Material Advantage
All main materials are selected from first-line brands with qualified test reports for fire resistance, anti-static, and environmental protection, ensuring quality from the source. Core materials are pre-stocked to guarantee supply cycle and prevent inferior materials from entering the site.
Process Advantage
We have standardized construction procedures and a certified engineering team, strictly implementing a three-level quality inspection system (team self-inspection, project re-inspection, company final inspection). Each process must be accepted before moving to the next, ensuring compliance with national codes and industry standards.
Customization Advantage
We can customize based on customer’s room area, grade requirements, business scenario, and budget. Support for equipment brand selection, functional module addition/removal, and special environment adaptation (e.g., high altitude, high humidity, explosion-proof scenarios) — truly tailored to needs.
Cost Advantage
Own production base supports core cabinets, cabling, etc. Combined bulk purchasing with first-line brands reduces material costs. Integrated design and construction avoids duplicate investment from multiple suppliers, making the overall project cost more competitive.
Quality Advantage
Full project management from design to delivery. Before handover, we conduct a 72-hour full load test to ensure system stability and reliability. Provide long-term warranty, with extended warranty on core systems and lifetime technical support.
Product Category Details
- A-grade data center overall integration: highest availability, full redundant architecture, for finance, government core business.
- B-grade enterprise computer room integration: redundant configuration, meets enterprise core business needs, cost-effective, for medium/large enterprises.
- C-grade basic computer room integration: basic configuration for daily office and small business, short construction period, low cost.
- Shielded computer room integration: with electromagnetic shielding, for classified computer rooms, testing labs, etc.
- Edge computing site integration: miniaturized, rapid deployment, for edge computing, 5G base station support.
Product Attributes (SKU)
| SKU Code | Product Name | Suitable Area | Grade | Delivery Cycle |
| — | — | — | — | — |
| LA-JF-ZT-001 | Micro computer room overall integration | ≤20㎡ | C | 15 days |
| LA-JF-ZT-002 | Small computer room integration | 20-100㎡ | B | 30 days |
| LA-JF-ZT-003 | Medium computer room integration | 100-500㎡ | B/A | 60 days |
| LA-JF-ZT-004 | Large data center integration | ≥500㎡ | A | Customized |
| LA-JF-ZT-005 | Shielded computer room integration | Custom | B/A | Customized |
Stock Availability
- Standard racks, basic monitoring modules, standard power distribution components, anti-static floors, etc., are in sufficient stock.
- In-stock products can be shipped within 48 hours, with self-pickup and delivery options.
- Customized products are scheduled by production, with priority for urgent orders.
- Common spare parts are well-stocked to support after-sales maintenance.
OEM & Confidentiality
We provide full-process OEM labeling services, including custom brand logo, packaging, and documentation. Strict confidentiality agreements protect customer technical solutions, business information, and project data. Neutral shipping is available without manufacturer markings for channel customers. We also support project coordination and technical support to preserve the customer’s brand image.
Application Scenarios
- Finance: bank data centers, securities trading rooms, insurance information rooms.
- Government: government cloud rooms, administrative office rooms, smart city command centers.
- Healthcare: tertiary hospital information rooms, CDC data centers.
- Education: university campus network rooms, smart campus data centers.
- Industrial: industrial control rooms, smart manufacturing data centers.
- Telecom: communication rooms, edge computing sites, 5G core rooms.
- Enterprise: headquarters, branch offices, R&D center rooms.
Customization Service Details
Customization Scope
- Scale: room area, number of racks, backup duration, etc.
- Grade: redundant configuration per A/B/C standards.
- Function: add or remove modules like monitoring, smart management, energy saving.
- Brand: designated equipment brands/models to meet centralized procurement requirements.
- Scenario: adapt to high altitude, high temperature, high humidity, explosion-proof, confidential, etc.
Customization Process
- Requirement communication: clarify building goals, budget, timeline.
- On-site survey: technical team visits to verify site conditions.
- Solution design: provide customized design, configuration list, and quotation.
- Solution confirmation: both parties adjust and confirm final solution and contract.
- Production & construction: pre-stock materials and construct, with progress reports.
- Commissioning & acceptance: system debugging, customer acceptance, handover of completion documents.
- After-sales maintenance: warranty period with ongoing support.
Customization Advantages
- Exclusive solution: one-on-one technical interface for tailored solutions.
- Flexible adaptation: multi-dimensional customization to meet varying needs.
- Quick response: initial proposal within 24 hours for efficient project progress.
- Full service: dedicated contact from design to maintenance, ensuring delivery quality.
Successful Cases
Cooperating Customers
- A provincial branch data center of a state-owned bank.
- A municipal government cloud core computer room.
- Information room of a top-tier hospital.
- Campus network data center of a 985 university.
- Industrial control room of a large manufacturing enterprise.
Case Highlights
- Bank provincial branch 280㎡ A-grade data center: full redundant architecture, 60-day delivery, passed MLPS level 3 assessment, 3 years zero failure operation.
- Government cloud room project: integrated construction with PUE as low as 1.42, significant energy savings, passed government informatization acceptance.
- Hospital room project: dual power supply + diesel generator backup to ensure HIS system continuous operation, meeting medical business continuity requirements.
Product Troubleshooting
| Fault Type | Troubleshooting Steps | Handling Method |
| — | — | — |
| Room temperature/humidity out of range | 1. Check precision AC operation; 2. Check filter cleanliness; 3. Check for abnormal heat sources; 4. Check cold aisle sealing | 1. Clean filters, restart AC; 2. Adjust setpoints; 3. Remove heat source; 4. Repair cold aisle seal |
| Main power interruption alarm | 1. Check input status; 2. Check UPS switching; 3. Check breaker status | 1. UPS supplies automatically, contact utility for restoration time; 2. Start diesel generator if backup insufficient; 3. Reset tripped breaker and investigate |
| Fire false alarm | 1. Inspect detector location, confirm no fire; 2. Check for dust/moisture interference | 1. Reset alarm after confirming no fire; 2. Clean detector, remove interference; 3. Replace if repeated |
| Monitoring system offline | 1. Check monitor power; 2. Check network; 3. Check module power and wiring | 1. Restore power and network; 2. Reboot monitor; 3. Repair wiring, replace faulty module |
Maintenance & Service
Daily Inspection (Every Day)
- Review monitoring platform alarms, confirm system status.
- Record room temp/humidity, power parameters, AC operation.
- Check room hygiene, no unusual smell or noise.
Quarterly Maintenance
- Clean AC filters and evaporator, check refrigerant pressure.
- Check UPS parameters, perform battery discharge test.
- Check fire system pressure and detector status.
- Tighten power terminals, check grounding system.
- Clean dust from racks and equipment surfaces.
Annual Deep Maintenance
- Deep clean AC system, test fan and compressor performance.
- Full battery capacity test, replace failed cells.
- Full fire system function test, check agent pressure.
- Ground resistance test, infrared thermography of power distribution.
- Full calibration of monitoring system, software upgrade.
Factory Strength & After-sales Service
Factory Strength
- Modern production base with CNC bending, laser cutting, electrostatic spraying equipment.
- Qualifications include electronic and intelligent engineering professional contracting, fire protection engineering, etc.
- Senior design and construction team with core technicians having 10+ years of industry experience.
- Served thousands of government and enterprise customers across provinces.
After-sales Service
- 7×24-hour technical support hotline for immediate response.
- Free on-site repair during warranty, free replacement for non-human faults.
- Core systems have 1-3 year warranty, lifetime technical support.
- Regular on-site inspection service to proactively identify issues.
- Provide O&M training to guide customer’s staff on daily operations.
Procurement Service Guarantee
Supply Guarantee
Self-produced core hardware, strategic partnerships with domestic and international first-line brands, stable supply. Safety stock for common products, priority production for urgent orders, ensuring project delivery timelines.
Quality Guarantee
Strictly implement ISO 9001, inspect all products before entry, three-level quality inspection for construction, full-load test before delivery, all products meet national standards.
Logistics Guarantee
Partner with professional logistics providers, support delivery to site and unloading. Professional packaging for equipment, custom transport solutions for large and precision items.
After-sales Guarantee
Dedicated project contact for after-sales needs. Free repair/replacement during warranty, cost-effective maintenance after warranty. Nationwide on-site service with timely response.
Invoice Guarantee
Can issue 13% VAT special invoices and regular VAT invoices, with content per request. Delivered with goods or mailed separately, meeting financial reimbursement needs.
FAQ
Q: How long does overall construction typically take?
A: Micro rooms about 15 days, small rooms about 30 days, medium rooms about 60 days, large data centers customized based on scale. Specific timeline based on actual solution.
Q: Can we use specified brand equipment?
A: Yes, we support customer-specified brand selection to meet procurement and compliance needs, providing adaptable design and integration services.
Q: What is the warranty period?
A: Standard projects have 1-year overall warranty, core equipment can be 3 years, as per contract. Lifetime technical support.
Q: Is design service included?
A: Yes, we provide full design services from conceptual design to construction drawings and detailed design, with integrated delivery.
Conclusion
KITOZER’s data center overall construction integration delivers a compliant, reliable, and energy-efficient data center through a single accountable partner. With standardized processes, comprehensive customization, and full lifecycle support, we ensure your data center infrastructure is built to the highest standards and ready for future growth. Contact us today to start your project.