TogglePrecision Cooling for Data Centers: Frequently Asked Questions
Data center cooling accounts for 30-40% of total facility energy use. Selecting the right CRAC (Computer Room Air Conditioner) unit is critical for both equipment reliability and operational cost. Here are the most common questions we receive.
Q1: What size CRAC unit do I need?
Rule of thumb: allow 1kW of cooling per server kW. For a 10kW IT load, specify a 12-15kW cooling unit (20-50% margin). The KITOZER KZ-CR12 is rated at 12.5kW cooling at 50%RH, suitable for 8-10kW IT loads. For larger deployments, multiple units can be paralleled with N+1 redundancy.
Q2: Downflow vs. Upflow?
Downflow: Supplies cold air through raised floor plenum. Best for new builds with raised floors. Upflow: Exhausts hot air into ceiling plenum or returns overhead. Better for retrofit without raised floor. KITOZER offers both configurations: KZ-CR12-D (downflow) and KZ-CR12-U (upflow).
Q3: What temperature setpoint is recommended?
ASHRAE TC 9.9 recommends 18-27°C supply air. Most data centers run at 22-24°C with 40-50% RH. Each degree increase saves 2-3% cooling energy. KITOZER units support setpoint range 10-35°C with ±0.5°C accuracy.
Q4: How often should filters be changed?
Standard G4 filters every 3-6 months in a clean environment, every 1-3 months in dusty conditions. Differential pressure sensors trigger replacement alerts. KITOZER units ship with a 2-year filter supply.
Q5: Water-cooled vs. Air-cooled?
| Feature | Air-cooled | Water-cooled |
|---|---|---|
| Installation | Simpler, condenser outside | Requires cooling tower/piping |
| Efficiency | COP 2.8-3.2 | COP 4.0-5.5 |
| Noise | Higher (outdoor fan) | Lower (pump noise only) |
| Cost | $3,500 – $6,000 | $8,000 – $15,000 (tower + piping) |
| Best For | <50kW IT load | >50kW or 24/7 efficiency priority |
Q6: What is the difference between CRAC and CRAH?
CRAC (Computer Room Air Conditioner) has compressor-based refrigeration. CRAH (Computer Room Air Handler) circulates chilled water without on-board compressor. KITOZER provides both: KZ-CR series (CRAC, self-contained) and KZ-CH series (CRAH, water coil).
KITOZER CRAC Specifications
| Model | Cooling Capacity | Airflow | Dimensions | Reference Price |
|---|---|---|---|---|
| KZ-CR08 | 8.0 kW | 2000 m³/h | 950×700×1900mm | $3,200 |
| KZ-CR12 | 12.5 kW | 3000 m³/h | 1100×750×1950mm | $4,500 |
| KZ-CR20 | 20.0 kW | 4500 m³/h | 1400×850×2000mm | $6,800 |
| KZ-CR30 | 30.0 kW | 6500 m³/h | 1600×950×2050mm | $9,500 |
SEO Tags
Core: precision cooling, CRAC unit, data center air conditioning, CRAH unit
Long-tail: data center cooling system, 12kW precision AC, raised floor cooling, CRAC vs CRAH
Brand: KITOZER CRAC, KZ-CR series, precision air conditioning
Meta Title: Data Center Precision Cooling FAQ | KITOZER CRAC Unit Guide
Meta Description: Answers to common data center cooling questions. CRAC sizing, types, maintenance and pricing. KITOZER precision air conditioning units for server rooms.
Contact
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER)
Tel/WeChat: +86 13922289957 / +86 18520668845
WhatsApp: +86 19068534140
Web: www.lain.com.cn | www.gdlain.com
Address: Chaotian Park, Zhongrun Industrial Zone, Shilou, Panyu, Guangzhou, China