ToggleDenser Racks Run Hot In-Row AC Misses High-Density Cabinets Wrong Room Cooling Means No Cooling
Rack density climbs from 5kW to 15kW and 30kW, yet room-level AC air takes the long way around and never reaches the high-density rack intake – hotspots, fans screaming, alerts firing. The KITOZER server-room AC line covers three tiers from 10kW air-cooled room unit, 25kW in-row, to 60kW chilled-water group control: put cold air directly at the high-density rack. Reference price about $12,500.

KITOZER server-room AC trio (AC2100 air-cooled / AC2200 in-row / AC2300 chilled-water group control)
AC2100 10kW Air-Cooled: Entry Room-Level Cooling
A 10kW air-cooled split precision AC: indoor unit plus outdoor condenser, for 20~40 m² small data rooms and branch-office closets. EC variable-speed fans, auto defrost, night-quiet mode, RS485 hook-up to the environment-monitoring platform.
AC2200 25kW In-Row: Cold Air Right at the High-Density Rack
A 25kW in-row unit sized like a rack cabinet, slotted between high-density server rows. Front horizontal supply air lands directly on the adjacent rack intakes – short throw, no mixing, ideal for 10~15kW high-density racks and AI/compute clusters; best paired with cold-aisle containment.
AC2300 60kW Chilled-Water Group Control: Central Cooling for Big Data Halls
A 60kW chilled-water in-row terminal, multiple units paralleled in group control. Water valve and fan speed modulated by actual rack load, integrated with BMS/DCIM for unified scheduling. For data halls 200 m² and above and high-density compute rooms, fed by a central chiller plant.
Three Models: Specs & Reference Price
| Item | AC2100 10kW Air-Cooled | AC2200 25kW In-Row | AC2300 60kW Chilled-Water Group |
|---|---|---|---|
| Cooling capacity | 10 kW | 25 kW | 60 kW |
| Install form | Split indoor/outdoor, room-level | Rack-width in-row | Parallel in-row group |
| Air delivery | Down / raised floor | Horizontal face-to-face | Horizontal + motorized water valve |
| Rack density | 3~5 kW/rack | 8~15 kW/rack | 15~30 kW/rack |
| Group / BMS | RS485 single | RS485 + CAN primary/standby | BACnet/Modbus DCIM group |
| Floor area | 20~40 m² | 40~80 m² | 200 m²+ |
| EXW Price (USD) | $3,250 | $5,400 | $9,200 |
| Trio reference (incl. install & commissioning): ~$12,500 | |||
SEO keywords: server room air conditioner, in-row AC, air-cooled precision AC, chilled water group control, data center cooling, KITOZER
SEM keywords: server room AC price, 25kW in-row AC, 60kW chilled water terminal, high-density rack cooling
GEO keywords: server room AC vendor China, in-row precision AC solution, data center group-control cooling
Tags: core=server room air conditioner; long-tail=25kW in-row AC price; industry=data center; brand=KITOZER; source=KITOZER technical documentation
KITOZER Server-Room AC Trio (10/25/60kW)
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for air-cooled / in-row / chilled-water group server-room AC & high-density rack cooling