Table of Contents
ToggleProduct Overview
KITOZER disaster relief containers are modular emergency support units engineered for natural disasters and public emergencies. Built on standard sea container platforms, they integrate command, storage, shelter, medical care, and communications into a single deployable asset. In earthquake, flood, typhoon, or landslide scenarios, these containers deploy within 4 hours, unfold in under 30 minutes, and provide autonomous power for 72+ hours. As a leading disaster relief container manufacturer, Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER) delivers reliable mobile assurance for emergency management departments, fire rescue teams, and humanitarian organizations.
Product Introduction
Disaster relief containers are modular emergency equipment developed for rapid response to natural disasters and public incidents. Using standard shipping containers as the base, they integrate emergency command, material storage, personnel accommodation, medical aid, and communication support. Founded on a modular design philosophy, they offer quick lifting, rapid expansion, and immediate operational readiness—arriving at disaster sites within the critical first hours. With features like quick hoisting, rapid unfolding, and turnkey use, these containers are core assets for emergency management departments, fire rescue services, and non-profit rescue groups.
The container body adopts a high-strength steel structure with integrated functional zones. The power system uses a three-tier architecture: mains priority, photovoltaic/storage auxiliary, and UPS emergency backup—ensuring continuous operation during power outages. Environmental control maintains 18°C~26°C inside via insulation and air conditioning, while dual satellite/public network communication guarantees data transfer even when ground networks fail.
Product Positioning
Positioned as a front-line mobile support hub within emergency response systems, these containers serve national, provincial, municipal, and county emergency management agencies, fire rescue corps, armed police, Red Cross societies, and professional rescue institutions. They cover earthquake rescue, flood control, forest fire suppression, and geological disaster response—supporting a comprehensive “all-hazard, major-emergency” rescue guarantee system.
Core Value
- Rapid Response: Deployed at disaster sites within 4 hours; fully functional within 2 hours, significantly compressing emergency response time.
- Comprehensive Support: A single unit integrates material storage, office space, temporary shelter, communications, and power—reducing multi-equipment coordination costs.
- Environmental Adaptability: Operates in extreme temperatures from -40°C to +60°C; performs reliably in high-altitude, high-humidity, high-salt-spray, and other demanding terrains.
- Long-term Storage: Designed for a 15+ year storage life; serves as an emergency material reserve warehouse peacetime and instantly converts to rescue platform during disasters.
Product Highlights
- Standard container dimensions—compatible with global sea, land, and air multimodal transport; easy lifting and transport.
- One-piece foldable expansion—no heavy construction machinery required; 3 people complete setup within 30 minutes.
- Integrated photovoltaic storage system—runs independent of mains power for 72+ hours.
- Triple protection—waterproof, fireproof, and shockproof, meeting complex disaster-site requirements.
- Standardized interfaces—seamlessly connects with command vehicles, drones, satellite communication, and other equipment.
Product Classification and Composition
Classification by Function
- Disaster Command Container: Includes command hall, meeting room, communications room—for on-site command and dispatch.
- Disaster Shelter Container: Equipped with foldable bunks, ventilation, air conditioning, sanitary facilities—for temporary accommodation of affected people.
- Disaster Medical Container: Integrated treatment tables, medicine cabinets, disinfection equipment—serves as a mobile medical aid point.
- Comprehensive Disaster Container: Balances material storage and office/command functions—suited for small-to-medium disaster scenes.
System Components
The disaster relief container consists of the following subsystems:
- Container Body System: Standard container structure, reinforced frame, sealing structure, thermal insulation layer.
- Electrical Power System: Distribution cabinet, UPS, photovoltaic panels, storage batteries, lighting system.
- Environmental Control System: Air conditioning units, fresh air system, ventilation, temperature/humidity control modules.
- Communication Command System: Satellite phone, 4G/5G base station, radio repeater, video conference terminal, display screen.
- Material Storage System: Heavy-duty shelving, cargo securing devices, moisture-proof layers, smart warehouse management terminal.
- Safety Protection System: Fire-retardant materials, emergency exits, smoke alarms, fire extinguishers, lightning protection and grounding.
- Life Support System: Water purification unit, sanitary facilities, foldable bunks, kitchen counter (optional).
System Working Principle
The design principle is “modular integration, rapid deployment, independent operation.” The container uses a standard steel structure as the main load-bearing body, with functional zones delivering different support capabilities. The power system adopts a “mains primary, PV/storage auxiliary, UPS emergency backup” three-tier architecture to guarantee continued operation of core equipment during outages. Environmental control combines insulation and air conditioning to keep the interior temperature stable at 18°C~26°C, meeting personnel office and equipment operating requirements. Communication systems use dual satellite and public network links to ensure information transmission even when local communications are interrupted.
The expansion mechanism uses mechanical links combined with hydraulic assistance. In the folded state, the container retains standard dimensions for transport; after expansion, internal usable area expands by 2–3 times, greatly maximizing space efficiency. The entire system is plug-and-play: all subsystems are pre-integrated inside the container; only an external power connection (or activating the PV system) is needed upon arrival—no complex installation or commissioning.
Technical Parameters
| Parameter Category | Specific Metric |
| — | — |
| External Dimensions (Transport) | 6058×2438×2896mm (20ft) / 12192×2438×2896mm (40ft) |
| Expanded Usable Area | 20ft: 18~30㎡; 40ft: 40~72㎡ |
| Design Service Life | ≥15 years |
| Operating Temperature | -40°C ~ +60°C |
| Protection Rating | Box IP65, internal equipment IP30 |
| Wind Resistance | Level 12 (117km/h) |
| Seismic Resistance | Intensity 8 |
| Fire Rating | Box structure A-class non-combustible; interior B1-class flame-retardant |
| Independent Power Duration | ≥72 hours of continuous operation for core equipment (fully charged) |
| Deployment Time | ≤30 minutes (3 operators) |
| Recovery Time | ≤45 minutes |
| Container Self-weight | 20ft: approx. 3.5~5.5t; 40ft: approx. 6.5~9t |
| Rated Load | 20ft: ≥10t; 40ft: ≥20t |
Configuration List
| No. | Configuration | Specification/Model | Qty | Remarks |
| — | — | — | — | — |
| 1 | Standard container body | 20ft/40ft high-strength steel | 1 set | Main body |
| 2 | Thermal insulation layer | 50mm rock wool + polyurethane composite | 1 set | Full coverage |
| 3 | Integrated distribution cabinet | 380V/220V, 32 circuits | 1 unit | With leakage protection |
| 4 | UPS | 3KVA/6KVA | 1 unit | 2-hour backup |
| 5 | Photovoltaic power system | 2kW/5kW | 1 set | Includes storage battery |
| 6 | Air conditioning unit | 1.5HP/3HP | 1~2 units | Industrial grade |
| 7 | Fresh air ventilation system | Airflow 500m³/h | 1 set | With filter |
| 8 | LED lighting system | Panel lights + emergency lights | 1 set | Illuminance ≥300lux |
| 9 | Anti-static floor | 600×600mm | Full floor | Load-bearing ≥500kg/㎡ |
| 10 | Heavy-duty storage rack | 2000×600×2000mm | 2~4 sets | Each layer load 200kg |
| 11 | Satellite communication terminal | Portable/fixed | 1 unit | Optional |
| 12 | Video display screen | 55-inch splicing screen | 1 set | Optional |
| 13 | Fire extinguishing equipment | Aerosol + dry powder extinguisher | 1 set | Standard |
| 14 | Emergency exit door/window | Fire-proof tempered glass | 1~2 sets | Standard |
| 15 | Lightning protection and grounding | Grounding resistance ≤4Ω | 1 set | Standard |
Core Advantages
Material Advantage
The container body uses Q235B high-strength weather-resistant structural steel, yield strength ≥235MPa. The surface is treated with hot-dip galvanizing + fluorocarbon spraying (dual anti-corrosion), passing 1000+ hours of salt spray testing without rust. The insulation layer uses composite rock wool and polyurethane, with a thermal conductivity ≤0.035W/(m·K), combining fire protection and thermal insulation. Interior panels are A-class fire-rated color steel plates, environmentally friendly, odorless, easy to clean and disinfect, meeting disaster relief and epidemic prevention hygiene requirements.
Craftsmanship Advantage
Adopting modular prefabrication, all components are produced, installed, and commissioned in the factory. Each container undergoes a 72-hour full-load joint commissioning test before shipment. Robot welding is used for the frame, providing uniform, full weld seams that pass 100% flaw detection. Sealing uses EPDM rubber strips plus waterproof adhesive (dual sealing), ensuring no leakage under heavy rain. Internal wiring is segregated (strong/weak current), fully enclosed in cable trays, compliant with electrical safety codes.
Customization Advantage
Supports full-scenario deep customization: internal functional zoning, equipment additions/removals, exterior painting/logos. We provide full-process customization from requirement analysis, solution design, manufacturing, to installation and commissioning. Standardized expansion interfaces are reserved for future upgrades. Structural customization includes single-side expansion, double-side expansion, double-layer lifting, etc., meeting different space needs.
Cost Advantage
The integrated design reduces overall costs by over 30% compared to traditional site-built panel houses. Containers are reusable; the per-use cost is only 1/5 of temporary structures. Standardized production shortens delivery times and offers significant bulk purchase cost benefits. Daily maintenance is minimal—only periodic checks of seals and electrical systems, with no major repair costs.
Quality Advantage
Strictly follows ISO9001 quality management. Every process includes inspection points. Before delivery, each unit undergoes rain, vibration, high/low-temperature, and other environmental tests. Core components are sourced from top domestic and international brands, ensuring low failure rates and long service life. We offer a 3-year entire-unit warranty and lifetime maintenance, with full traceability.
Product Category Details
20ft Standard Disaster Command Container
Basic command platform integrating command office, material storage, and equipment room. Suitable for county-level emergency teams and small-to-medium disaster sites. Cost-effective and flexible to deploy.
40ft Expanded Disaster Command Container
Double-side expansion structure with command hall, meeting room, rest room, and equipment room. Equipped with large screen display and satellite communication. Suitable for municipal-level and above emergency command, large disaster scenes.
20ft Disaster Shelter Container
Built-in 12 foldable bunks, equipped with air conditioning, ventilation, lighting, and sanitary facilities. Accommodates 12 persons temporarily. Suitable for temporary shelter of affected people and rest of rescue personnel.
40ft Disaster Medical Container
Features treatment area, medicine area, observation area, disinfection area, equipped with basic medical equipment. Acts as a mobile medical station for on-site emergency aid and common disease treatment.
Custom Disaster Special Container
Customizable for special functions such as disaster communication containers, water purification containers, power generation containers, catering containers, and other special functional models.
Materials and Process Analysis
Material Details
- Container Steel: Angang Q235B hot-rolled plate, side panel thickness 2.0mm, end panel 2.5mm, top plate 3.0mm, bottom frame uses 10# channel steel + 5mm checkered plate. Overall structural strength meets marine and lifting requirements.
- Anti-corrosion Coating: Bottom hot-dip galvanized layer ≥80μm, intermediate epoxy zinc-rich primer ≥40μm, top fluorocarbon paint ≥60μm, total coating thickness ≥180μm, excellent weather and corrosion resistance.
- Insulation Material: Inner 50mm high-density rock wool (A-class fireproof), outer 20mm polyurethane insulation board; composite structure balances fire resistance and thermal efficiency.
- Interior Material: 0.5mm thick color steel sandwich panel with flame-retardant polystyrene core; surface film is scratch-resistant and easy to clean.
- Sealing Material: EPDM rubber sealing strip, aging-resistant, high/low temperature resistant, service life ≥10 years.
Core Processes
- CNC Cutting: All steel plates cut by laser CNC, dimensional accuracy ±0.5mm, ensuring assembly precision.
- Robotic Welding: Main frames use industrial robot automatic welding with precise parameters, uniform weld appearance, stable strength.
- Overall Spray Coating: After welding, the whole body undergoes pre-treatment, phosphating, and powder coating, ensuring strong adhesion and no dead corners.
- Modular Pre-installation: Electrical, HVAC, and equipment are pre-installed on dedicated tooling benches before being mounted into the container, ensuring high installation accuracy and easy maintenance.
- Rain Test: Each container undergoes a 2-hour strong rain test (water pressure 0.1MPa) with all-around spraying to ensure no leakage.
Safety Certifications
- ISO9001 Quality Management System Certification
- ISO14001 Environmental Management System Certification
- National Fire Equipment Quality Supervision and Inspection Center Test Report
- CCS Classification Society Certification for container bodies
- 3C Certification for electrical systems
- Lightning protection grounding test report
Stock Availability
We maintain ready stock of 20ft standard disaster relief containers and 40ft standard material containers. Standard configurations ship within 72 hours. Commonly used accessories (air conditioners, distribution cabinets, UPS, lighting) are in safety stock for quick replenishment and repairs. The Guangzhou headquarters warehouse holds 30+ units in stock, and national partner warehouses stock simultaneously to ensure rapid delivery for emergency orders.
OEM/ODM and Confidentiality Services
We support full-process OEM/ODM machining services, including custom exterior branding, instruction manual customization, and packaging customization. Strict confidentiality agreements are signed to protect your technical solutions, product parameters, and cooperation information. Neutral packaging is available to protect your channel resources. With annual production capacity of 500+ units, we accept bulk OEM orders with stable delivery cycles.
Product SKUs
| SKU | Product Name | Specification | Unit | Remarks |
| — | — | — | — | — |
| LA-JZ-20Z | Disaster Command Container | 20ft standard | Unit | Standard version |
| LA-JZ-20Z-P | Disaster Command Container | 20ft PV-enhanced | Unit | Plus 5kW PV |
| LA-JZ-40Z | Disaster Command Container | 40ft expanded | Unit | Double-side expansion |
| LA-JZ-20A | Disaster Shelter Container | 20ft 12-person | Unit | Standard bunks |
| LA-JZ-40A | Disaster Shelter Container | 40ft 24-person | Unit | Double-side expansion |
| LA-JZ-20Y | Disaster Medical Container | 20ft basic | Unit | Includes basic medical equipment |
| LA-JZ-DZ | Disaster Special Container | Custom | Unit | Made to order |
Specification Technical Parameter Table
| Item | 20ft Standard Disaster Container | 40ft Expanded Disaster Container |
| — | — | — |
| External dimensions (L×W×H) | 6058×2438×2896mm | 12192×2438×2896mm |
| Internal dimensions (L×W×H) | 5898×2298×2580mm | 12032×2298×2580mm |
| Expanded width | 2438mm (non-expanded) / 4800mm (single-side expansion) | 6000mm (double-side expansion) |
| Internal usable area | approx. 13.5㎡ / 28㎡ (expanded) | approx. 27.6㎡ / 72㎡ (expanded) |
| Container self-weight | approx. 3800kg | approx. 7500kg |
| Rated load | 10000kg | 20000kg |
| Power supply capacity | 3kW UPS + 2kW PV | 6kW UPS + 5kW PV |
| Air conditioning power | 1.5HP | 3HP×2 |
| Lighting power | 200W | 400W |
| Protection rating | IP65 | IP65 |
| Operating temperature | -40°C~+60°C | -40°C~+60°C |
| Deployment crew/time | 3 persons/30min | 5 persons/60min |
Application Scenarios
- Natural Disaster Rescue: On-site command and shelter for earthquakes, floods, typhoons, mudslides, snow disasters.
- Public Health Events: On-site command and medical support for epidemic control and public health emergencies.
- Production Safety Accidents: Rescue command for mine accidents, chemical accidents, building collapses, etc.
- Forest Fire Rescue: Frontline command for forest fire prevention, personnel rest, and material replenishment.
- Emergency Drills: Drill support for emergency departments and fire rescue teams at all levels.
- Major Event Support: Standby support for large sports events, gatherings, and festivals.
- Remote Area Operations: Temporary office and living support for field exploration, engineering construction, and border posts.
Customization Services
Customization Scope
- Size customization: non-standard dimensions, lengthened/widened, double-layer structures.
- Function configuration customization: add/remove equipment, adjust partitions, upgrade communication and power systems.
- Appearance customization: custom paint colors, logos, warning patterns.
- Structural customization: single-side expansion, double-side expansion, lifting roof, expansion cabins, etc.
- Special function customization: explosion-proof, shielding, bulletproof, constant temperature/humidity, etc.
Customization Process
- Requirement communication: You submit requirements; our technical engineers confirm parameters.
- Solution design: Draft custom solution drawings and quotation within 3 working days.
- Contract signing: Both parties confirm the plan, sign a customization contract, and pay deposit.
- Production: Organize production per the plan, cycle 15–30 days.
- Factory acceptance: You inspect on-site or via video, confirm qualification before shipping.
- On-site commissioning: Technicians arrive to install, debug, and train operators.
- After-sales follow-up: Regular visits, lifetime maintenance.
Customization Advantages
- Over 10 years of special container customization experience; mature technology, strong solution implementation.
- Own sheet metal, spraying, and assembly production lines; high customization flexibility.
- Professional technical team providing full-process support from design to use.
- Standardized process ensures controllable delivery and stable quality.
- Customized products enjoy the same complete warranty and after-sales service.
Success Cases
Partner Clients
- A provincial emergency management department
- A municipal fire rescue detachment
- A national-level emergency rescue team
- A Red Cross emergency rescue brigade
- A central SOE engineering bureau emergency support center
Case Highlights
- Provincial emergency material reserve project: Delivered 28 disaster material containers to a provincial emergency management department, distributed across 11 municipal reserve warehouses, forming a 4-hour emergency response circle. Used multiple times in flood control and disaster relief, operating stably.
- Fire rescue command project: Customized 5 units of 40ft expanded command containers for a municipal fire detachment, equipped with satellite communication and large-screen command systems. Played a core command role in multiple fire and accident rescues.
- Earthquake emergency drill project: Customized a comprehensive disaster support container group for a national rescue team, achieving full deployment within 2 hours during a national earthquake drill, earning high praise from the drill headquarters.
Procurement Service Guarantee
Supply Guarantee
- Own large-scale production base: monthly capacity of 50+ units; standard models in stock.
- Raw materials and core components sourced via strategic agreements with leading suppliers for stable supply.
- Bulk orders can receive priority scheduling to ensure on-time delivery.
Quality Guarantee
- Strict ISO9001 quality management, 12 inspection checkpoints from raw material entry to finished product.
- Core components from top brands, fully traceable.
- Each container passes 72-hour power-on test and rain test before leaving factory, ensuring 100% factory qualification.
Logistics Guarantee
- Long-term cooperation with major large-item logistics companies; door-to-door transport available.
- Professional lifting and fixing solutions ensure safe, damage-free transport.
- Support sea, rail, and road multimodal transport to all regions of China and overseas.
After-sales Guarantee
- 3-year whole-unit warranty, 5-year core component warranty, lifetime technical support and repair services.
- Multiple service outlets nationwide; response to service requests within 48 hours.
- Free operator training, regular follow-up inspections.
- Original spare parts always in stock for convenient replacement.
Invoice Guarantee
- Can issue 13% VAT special invoices; supports invoice-before-payment. Invoice shipped with goods or separately mailed.
FAQ
Q1: Can the disaster relief container be used in areas without mains power?
A: Yes. Standard configuration includes UPS; photovoltaic power systems and diesel generators are optional. It can operate completely off-grid, ensuring more than 72 hours of continuous operation for core equipment when fully charged.
Q2: What vehicle is needed for transport? Can it go on highways?
A: Standard containers can be transported by ordinary flatbed trailers, meeting road transport standards, and can be driven on highways without special approval.
Q3: Does deployment require professionals? Is operation complicated?
A: No professional engineers are needed. The product uses quick-install design; we provide operation training. Ordinary staff can operate independently after 1 hour of training. 3 people can complete deployment in 30 minutes.
Q4: Can the internal layout be customized?
A: Absolutely. We support full-scenario customization: adjust partitions, add/remove equipment, and customize special structures and appearances.
Q5: What is the service life? Is daily maintenance troublesome?
A: Under normal use and maintenance, the container body can last over 15 years. Daily maintenance is very simple: mainly periodic checks of sealing strips, cleaning air conditioning filters, and checking electrical connections—no complex maintenance.
Product Troubleshooting Guide
| Fault | Possible Cause | Solution |
| — | — | — |
| Interior lights not working | Circuit breaker tripped, bulb damaged, loose wiring | Check distribution box breaker, reset; replace LED panel; check wiring terminals |
| Air conditioner not cooling | Power not connected, filter blocked, refrigerant low | Check AC power switch; clean filter; contact after-sales for refrigerant refill |
| Water leakage inside | Seal strip aging, drain blocked, loose screws | Inspect/replace seals; clean drain holes; tighten top connection screws |
| UPS alarm | Mains interruption, low battery voltage, overload | Confirm mains status; turn off non-essential devices to reduce load; contact after-sales to check battery |
| Door lock or switch not smooth | Lock rusted, seal strip deformed | Apply anti-rust lubricant; adjust seal strip position |
| Expansion structure sticking | Link deformation, debris jam, lack of lubrication | Remove debris; check links for deformation; lubricate moving parts |
Note: For electrical and core component faults, contact professional after-sales personnel; do not disassemble yourself.
Maintenance Guide
Daily Maintenance (Monthly)
- Inspect container exterior, clean surface debris and dust.
- Check door locks and hinges, apply anti-rust lubricant.
- Check seal strips for integrity, clean dust on surfaces.
- Check air conditioning filter, clean or replace as needed.
- Verify lighting and sockets function properly.
Quarterly Maintenance
- Inspect distribution box terminals, tighten loose screws.
- Check UPS operation, perform discharge test.
- Check drain holes and drainage channels for unobstructed flow.
- Verify lightning protection grounding connections are secure.
- Check internal shelves and securing devices for stability.
Annual Maintenance
- Full inspection of anti-corrosion coating, repair localized scratches.
- Comprehensive electrical insulation test.
- Verify PV system generation efficiency, clean solar panels.
- Inspect structural welds and connecting bolts, tighten and apply anti-rust.
- Conduct overall functional test to identify potential faults.
Company Strength and After-sales Service
Guangzhou Lain Intelligent System Development Co., Ltd. has over 10 years of experience in R&D and production of special-purpose containers. The production base covers 30,000㎡, equipped with full-process lines: CNC cutting, robotic welding, automated spraying, and final assembly. We have a professional R&D team of 30+ people and hold multiple utility model patents and software copyrights.
The after-sales service network covers the whole country, with four major service centers in South China, East China, North China, and Southwest China. We provide 7×24 hotline support, 48-hour on-site service for general faults, and backup equipment for major failures. Every product has an electronic file for full lifecycle tracking, regular active follow-ups, and inspections to ensure long-term stability.
Conclusion
Disaster relief containers are vital equipment in modern emergency response systems—hardware that directly improves response speed and support capability. Guangzhou Lain adheres to the philosophy of “technology empowering emergency, quality guarding safety,” continuously developing high-quality emergency support container products. We provide reliable equipment support for emergency management departments and rescue teams, working together to build a strong defense line for disaster prevention, mitigation, and relief.