2. Project Requirement Description

This project is a supporting construction project for a low-voltage power distribution system. It requires the configuration of a full series of distribution switchgear products to achieve circuit on/off control, overload protection, short-circuit protection, leakage protection, and power source transfer functions for distribution circuits. The products must be compatible with 380V/220V low-voltage distribution systems and meet the electrical safety requirements for scenarios including industrial plants, commercial buildings, and data center power distribution.

Operating Environment Requirements:

  • Installation Type: Indoor installation
  • Ambient Temperature Range: -15℃ to +45℃
  • Altitude: ≤2000m
  • Pollution Degree: Class 3
  • System Rated Frequency: 50Hz

3. System Composition Introduction

This distribution switchgear series comprises five major product categories, covering the full hierarchy of protection and control requirements for terminal circuits, main incoming circuits, and branch circuits:

Category Application
Miniature Circuit Breakers (MCB) Terminal circuit protection
Molded Case Circuit Breakers (MCCB) Main incoming and power circuit protection
Load Isolation Switches Circuit isolation and maintenance
Residual Current Circuit Breakers (RCCB) Terminal leakage protection
Automatic Transfer Switches (ATS) Dual power supply switching

The products can be flexibly combined to suit distribution systems of various capacities.

4. Core Product Specifications & Parameters

4.1 Miniature Circuit Breakers (MCB)

Parameter Specification
Rated Operating Voltage 400VAC
Rated Current Range 6A~63A
Tripping Characteristic Type C (5~10In instantaneous trip)
Breaking Capacity 6kA
Number of Poles 1P/2P/3P/4P optional
Mechanical Life ≥10,000 operations
Installation Method DIN 35mm rail mounting

4.2 Molded Case Circuit Breakers (MCCB)

Parameter Specification
Rated Operating Voltage 400VAC
Frame Rating 125A/250A/400A/630A
Rated Current 32A~630A adjustable
Breaking Capacity 25kA/35kA/50kA
Tripping Method Thermal-magnetic tripping; overload long-delay and short-circuit instantaneous protection
Number of Poles 3P/4P optional
Operation Method Manual operation
Installation Method Fixed type, front-connected

4.3 Load Isolation Switches

Parameter Specification
Rated Operating Voltage 400VAC
Rated Current 63A~1000A
Number of Poles 3P/4P
Isolation Function Complies with GB/T 14048.3 isolation requirements; clear visible break point
Mechanical Life ≥10,000 operations
Installation Method DIN rail / fixed type optional

4.4 Residual Current Circuit Breakers (RCCB)

Parameter Specification
Rated Operating Voltage 230V/400VAC
Rated Current 16A~125A
Residual Operating Current 30mA/100mA/300mA selectable
Residual Tripping Time ≤0.1s (AC type)
Protection Functions Overload protection, short-circuit protection, residual current protection
Number of Poles 2P/4P

4.5 Automatic Transfer Switches (ATS)

Parameter Specification
Rated Operating Voltage 400VAC
Rated Current 63A~630A
Number of Poles 4P
Transfer Mode Auto-return to normal, non-auto-return, manual (three modes)
Transfer Time ≤2s
Mechanical Life ≥8,000 operations
Special Functions Fire-fighting interlock, over/under-voltage protection

5. Core Functions & Features of Products

  • Line Protection Function: Overload long-delay protection and short-circuit instantaneous protection; fast circuit disconnection upon fault to prevent electrical fires and equipment damage.
  • Residual Current Protection: Leakage-type breakers continuously monitor residual current in the circuit, with instantaneous tripping when the threshold is exceeded, ensuring personal electrical safety.
  • Isolation & Maintenance Function: Isolation switches provide clear visible break points to ensure personnel safety during line maintenance.
  • Dual Power Transfer Function: Automatic transfer switches enable automatic switching between normal and standby power sources, ensuring power supply continuity for critical loads.
  • Manual Operation Function: All switches support manual open/close operation for routine maintenance and emergency handling.

6. Core Advantages of The Solution

  • Stable and Reliable Performance: High flame-retardant housing materials resistant to high temperature and aging; conductive parts made of high-quality oxygen-free copper with tin plating, featuring strong current-carrying capacity and low temperature rise.
  • Comprehensive Product Selection: Current ratings cover the full series from 6A to 630A; poles and tripping characteristics can be selected per requirements, suitable for the vast majority of low-voltage distribution scenarios.
  • Convenient Installation and Maintenance: Standard DIN rail or fixed installation with universal dimensions; high interchangeability; modular design facilitates future maintenance and upgrades.
  • Precise and Sensitive Tripping: Tripping mechanisms use high-precision bimetal strips and electromagnetic systems, providing stable tripping characteristics and minimal protection parameter deviation.
  • Comprehensive Safety Protection: Anti-misoperation structures and terminal covers prevent accidental electric shock, fully compliant with personal safety protection requirements.
  • Brand Quality Control: All KITOZER brand switches are independently developed and manufactured; core components undergo strict screening with 100% factory inspection before delivery.
  • Customization Capability: Tripping parameters, auxiliary contacts, alarm contacts, shunt releases, and other accessories can be customized per project requirements.
  • Cost-Effective Configuration: Product performance reaches the standard of leading domestic brands; high compatibility allows direct replacement of mainstream brand models, reducing procurement and replacement costs.
  • Stock Supply Assurance: Conventional models are maintained in substantial stock, enabling rapid dispatch after order confirmation to meet urgent project delivery requirements.

7. Manufacturer Strength Introduction

Guangzhou Lai’an Intelligent System Development Co., Ltd. (brand: KITOZER), together with Guangdong Lai’an Intelligent Computer Room Equipment Co., Ltd., is a specialized manufacturer integrating R&D, production, and sales of power distribution equipment. Key strengths include:

  • Founded 2002 — Over two decades of industry experience in power distribution and intelligent systems
  • ISO 9001 / ISO 14001 / ISO 45001 certified quality, environmental, and occupational health & safety management systems
  • National High-Tech Enterprise with independent R&D capabilities
  • Modern production base with a complete testing and inspection system
  • Project-confirmed manufacturing — no middlemen, ensuring competitive pricing
  • Complete quality inspection before shipment for every product
  • OEM/ODM services supported with strict confidentiality cooperation mechanisms
  • Ample stock of conventional products with short delivery cycles
  • Full-process technical support and after-sales service

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Miniature Circuit Breaker KZR-NXB/2P-C32 2P, rated 32A, Type C trip, 6kA breaking capacity, 400VAC 12 pc 16.58 198.92 KITOZER Terminal circuit protection
2 Miniature Circuit Breaker KZR-NXB/3P-C63 3P, rated 63A, Type C trip, 6kA breaking capacity, 400VAC 8 pc 29.45 235.61 KITOZER Power circuit protection
3 Molded Case Circuit Breaker KZR-M1/4P-160 4P, frame 250A, rated 160A, 35kA breaking capacity, thermal-magnetic trip 3 unit 170.94 512.81 KITOZER Main incoming circuit protection
4 Molded Case Circuit Breaker KZR-M1/3P-250 3P, frame 250A, rated 250A, 35kA breaking capacity, thermal-magnetic trip 2 unit 257.52 515.03 KITOZER Main power circuit protection
5 Load Isolation Switch KZR-OT/3P-100 3P, rated 100A, isolation type, front-connected 4 unit 53.28 213.11 KITOZER Circuit isolation & maintenance
6 Residual Current Circuit Breaker KZR-LM/4P-100 4P, rated 100A, residual operating current 30mA, AC type 3 unit 124.32 372.95 KITOZER Terminal leakage protection
7 Automatic Transfer Switch KZR-ATS/4P-160 4P, rated 160A, auto-return to normal, with fire-fighting interlock 1 unit 532.78 532.78 KITOZER Dual-circuit power switching
8 Auxiliary Contact for MCCB KZR-FZ-2NO2NC 2NO+2NC, compatible with MCCB 5 pc 12.58 62.90 KITOZER Signal feedback accessory

Total Quotation Price: USD 2,644.11

*Note: The above prices exclude tax and freight.*

9. Quotation Terms & Conditions

1. Currency: All prices are quoted in USD (United States Dollars) as listed above.

2. Price Basis: EXW (Ex-Works) Guangzhou, China, or as negotiated.

3. Taxation: The above quotation excludes tax. A 10% surcharge applies for issuing special VAT invoices; a 3% surcharge applies for issuing regular invoices.

4. Freight: To be borne by the buyer (freight collect) via logistics delivery. Designated carriers can be arranged upon request.

5. Payment Terms: 30% deposit and 70% balance before shipment (negotiable).

6. Lead Time: 15-30 working days depending on configuration and order quantity.

7. Validity: This quotation is valid for 30 days from the date of issue.

8. Packing: Standard export packing; specific packing requirements may be discussed for additional costs.

9. Compliance: All products comply with the applicable national and industry standards listed in Section 2 of this document.

10. After-sales Service Description

  • Warranty Period: 12-24 months for all products depending on product category.
  • Lifetime Technical Support: Free technical consultation throughout the product lifecycle.
  • Spare Parts Availability: Long-term supply of spare parts to support ongoing maintenance.
  • Remote Troubleshooting: Technical team available for remote diagnosis and guidance.
  • On-site Service: Field service available upon request (travel expenses to be quoted separately).
  • Quality Assurance: All products undergo complete inspection prior to shipment; any quality issues confirmed within the warranty period will be addressed promptly.
  • Replacement Policy: Defective products confirmed within warranty shall be repaired or replaced free of charge.

11. Contact & Order Information

To place an order or request further information, please contact the KITOZER sales team:

  • Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Computer Room Equipment Co., Ltd.
  • Brand: KITOZER
  • Order via Official Website: gdlain.com
  • Response Commitment: All inquiries receive a response within 24 hours.
  • Customization Inquiries: Please provide detailed specifications for tailored quotations.

12. SEO Keywords & Tags

KITOZER quotation, distribution switchgear price list, low-voltage distribution switchgear models and specifications, distribution switchgear manufacturer, industrial distribution switchgear factory, molded case circuit breaker project-confirmed, miniature circuit breaker parameters, automatic transfer switch price, residual current circuit breaker selection, distribution switchgear wholesale quotation, KITOZER distribution switch pricing, low-voltage circuit breaker supplier, switchgear complete set quotation solution

Shopping Cart