KITOZER
KITOZER

Explosion-Proof Container | KITOZER

Product Overview

Explosion-proof containers are specially designed industrial containers for flammable and explosive hazardous environments, utilizing explosion-proof structural design and explosion-proof electrical configuration. They are safe for use in high-risk locations such as petroleum, chemical, gas, military, and pharmaceutical industries where explosive gases or dust may be present. The entire container meets explosion-proof standards such as ExdⅡBT4/ExdⅡCT6, integrating explosion-proof power distribution, lighting, ventilation, and monitoring systems. They can serve as explosion-proof control rooms, analysis shelters, storage rooms, equipment rooms, etc., providing an integrated solution for equipment integration, personnel operation, and material storage in hazardous areas.

Product Introduction

Our explosion-proof containers are engineered to contain internal explosions without rupturing and to prevent external explosions by eliminating ignition sources. Built on a heavy-duty steel frame with double-wall panel construction filled with fire-resistant insulation, they provide a robust barrier against explosive forces. The containers are fully fitted with explosion-proof electrical equipment, HVAC, and monitoring systems, making them ideal for use in hazardous zones classified as Zone 0, 1, or 2, and for both gas and dust explosion risks.

Product Positioning

Targeted at industrial scenarios with explosive hazardous media—petrochemicals, natural gas, coal chemicals, pharmaceuticals, military, and grain/oil processing—these containers offer a standardized, modular, rapidly deployable explosion-proof integrated space solution. They replace traditional civil construction explosion-proof buildings, dramatically shortening project cycles, reducing on-site construction risk, and lowering overall costs.

Core Value

  • Intrinsic Safety: Full container explosion-proof certification from structure to electrical, fully compliant with explosion-proof regulations, eliminating explosion risks.
  • Rapid Deployment: Factory prefabricated and delivered as a one-piece unit; only hoisting and electrical connection are needed on site.
  • Flexible Relocation: Container structure allows complete hoisting and transport, fitting project moves or site adjustments.
  • Cost Effectiveness: Compared to traditional civil construction, overall costs are reduced by 30%-50%, and the container is reusable.

Product Highlights

  • Integrated explosion-proof certification, meeting GB3836 series standards, with third-party explosion-proof certificate available.
  • Double-layer steel plate with flame-retardant insulation structure, providing explosion-proof, fire-resistant, and heat-insulating properties.
  • Optional positive-pressure or flameproof designs to suit different hazardous area classifications.
  • Integrated explosion-proof air conditioning, ventilation, fire-fighting, and monitoring systems.
  • Supports 20ft/40ft standard and custom non-standard sizes, with flexible internal zoning.

Product Classification and Composition

Classification

  • By Explosion-Proof Type: Flameproof, positive-pressure, increased safety.
  • By Function: Control room, analysis shelter, power distribution room, storage container, rest cabin.
  • By Hazardous Area: Suitable for Zone 0, 1, 2; gas or dust explosion proof.
  • By Size: 10ft, 20ft, 40ft standard, and non-standard custom dimensions.

System Composition

  • Container Body: Steel structure frame, explosion-proof wall panels, explosion-proof door, explosion-proof observation window.
  • Electrical System: Explosion-proof distribution box, junction box, switches, and lighting fixtures.
  • Ventilation System: Explosion-proof fans, ducting, air filters, and pressure monitoring.
  • Environmental Control: Explosion-proof air conditioning, heater, and dehumidifier.
  • Safety Monitoring: Combustible gas detectors, toxic gas detectors, audible/visual alarms.
  • Fire Protection: Dry powder extinguishing system, explosion-proof fire hydrant, emergency escape device.
  • Grounding and Static: Dedicated grounding busbar, static discharge device, and equipotential bonding.

System Principle

Explosion-proof containers achieve safe operation in hazardous areas through a three-layer protection system: structural isolation, electrical explosion-proofing, and environmental control.

  • Structural Isolation: The container uses a high-strength steel plate welded sealed structure. If an internal explosion occurs, the container withstands the blast pressure without rupture, and the flame is cooled and passed through the joint surfaces without igniting the external explosive atmosphere.
  • Positive-Pressure Type: Clean air is continuously supplied to maintain a slight positive pressure inside, preventing external explosive gases from entering. Pressure is monitored in real-time; if it falls below the threshold, automatic alarm and power cutoff occur.
  • Electrical Explosion-Proof: All internal electrical equipment is rated for the corresponding explosion-proof level, and cable entries are sealed to prevent sparks or high-temperature surfaces.
  • Safety Interlock: Sensors for gas detection, pressure monitoring, and door magnet interlocking trigger staged protection actions like alarm, ventilation, and power disconnection under abnormal conditions.

Technical Parameters

Parameter Technical Specification
— —
Explosion-proof Class ExdⅡBT4 Gb / ExdⅡCT6 Gb / px (positive pressure)
Protection Rating IP54 / IP65
Working Temperature -40℃ ~ +55℃
Container Material Q235B carbon steel / 304 stainless steel
Wall Plate Thickness Outer 4-6mm, inner 2-3mm
Insulation Layer 50-100mm rock wool / aluminum silicate
Rated Voltage AC220V/380V 50Hz
Installed Power 5kW – 50kW (customizable)
Internal Working Pressure 50-200Pa (positive pressure type)
Design Life ≥20 years

Specification Table

Model External Dimensions (L×W×H) Internal Dimensions (L×W×H) Rated Load Explosion-proof Class Standard Power Reference Weight
— — — — — — —
LA-FB-10 3000×2438×2896mm 2800×2280×2400mm 5t ExdⅡBT4 3kW 3.5t
LA-FB-20 6058×2438×2896mm 5850×2280×2400mm 10t ExdⅡBT4 8kW 6.5t
LA-FB-40 12192×2438×2896mm 12000×2280×2400mm 20t ExdⅡBT4 15kW 12t
LA-FB-20S 6058×2438×2896mm 5850×2280×2400mm 10t ExdⅡCT6 10kW 7.5t
LA-FB-ZY20 6058×2438×2896mm 5850×2280×2400mm 10t pxⅡBT4 12kW 7t

Configuration List (Sample Kit)

No. Component Model/Spec Qty Remarks
— — — — —
1 Container body 20GP/40GP custom 1 set Frame, wall, roof, floor
2 Explosion-proof door Single/double with window 1-2 Same class as container
3 Explosion-proof distribution box Custom circuits 1 Flameproof, with main switch
4 Explosion-proof LED lights 40W/60W Several By area
5 Explosion-proof axial fan Airflow as required 2 Inlet + exhaust
6 Explosion-proof air conditioner 1.5P/3P/5P 1-2 Cooling/heating
7 Combustible gas detector Catalytic combustion 2-4 With audible/visual alarm
8 Positive-pressure control unit — 1 set For positive-pressure type
9 Grounding system Copper busbar + terminals 1 set With static discharge
10 Emergency lighting Explosion-proof emergency light 2 Runtime ≥90 min

Core Advantages

Material Advantage

Container main structure uses genuine Q235B carbon steel plates (from Angang/Baosteel) or 304 stainless steel, with full thickness. Insulation is A-grade fire-resistant rock wool with low thermal conductivity. Seals are oil-resistant, aging-resistant NBR rubber. All materials come with quality certificates and test reports, traceable and verifiable.

Process Advantage

  • CNC laser cutting for precise dimensions (±0.5mm).
  • Robotic welding ensures uniform welds with 100% inspection pass.
  • Explosion-proof joint surfaces are precision machined to Ra≤6.3μm and gap within standards.
  • Full sandblasting to Sa2.5, followed by epoxy zinc-rich primer (80μm), intermediate (40μm), and polyurethane topcoat (60μm), total ≥180μm. Salt spray test over 1000 hours.
  • Each unit undergoes water pressure, air tightness, and live electrical tests before shipping.

Customization Advantage

Full customization in dimensions, layout, explosion-proof class, and system integration. Internal zoning can be designed based on on-site conditions, integrating analysis instruments, industrial computers, workstations, storage racks, etc. Professional explosion-proof engineers provide one-on-one design to ensure compliance and practicality.

Cost Advantage

Factory-scale production saves over 30% compared to on-site construction. No building approval process shortens project cycle by 60%. The container can be relocated and reused, saving secondary deployment costs, offering higher ROI over its lifecycle.

Quality Advantage

Certified by national authority explosion-proof testing agencies, with explosion-proof certificates. Production adheres to ISO9001, with quality checkpoints at every stage. Core electrical components are from leading domestic or imported brands. Complete technical documentation and acceptance documents support smooth project validation.

Customization/Service

Customization Scope

  • Dimensions: Non-standard lengths, widths, heights; multi-container splicing; special shapes.
  • Explosion-proof Class: ⅡB/ⅡC, T3/T4/T6 temperature groups, gas/dust explosion-proof.
  • Internal Layout: Functional zoning, workstations, equipment mounts, cylinder cabinets, shelves.
  • Systems: Air conditioning, ventilation, fire suppression, monitoring, communications, UPS.
  • Appearance: Colors, signage, logos, external attachment locations.

Customization Process

  1. Requirement discussion: client provides usage scenario, function needs, explosion-proof class, dimensions.
  2. Design proposal: engineers provide layout drawings, system configuration plan, and quotation.
  3. Contract confirmation: both parties confirm plan and price, sign contract, pay deposit.
  4. Manufacturing: production is scheduled, with progress updates.
  5. Factory inspection: comprehensive testing and inspection report.
  6. Delivery: payment balance, logistics arrangement, on-site installation guidance and commissioning.

OEM & Confidentiality

Full OEM/ODM services available—customer drawings, material supply, or label production. Strict confidentiality agreements ensure customer drawings and technical data remain undisclosed. Products can feature client branding with neutral packaging. Annual production capacity exceeds 500 units, handling large and urgent orders.

Stock & Delivery

Standard 20ft explosion-proof containers are kept in stock with basic configuration (lighting, distribution, ventilation, gas detection) and can ship within 3-5 days. Upgrades like air conditioning, workstations, monitoring can be added in 7-10 days. 40ft and special configurations require stock verification.

Application Scenarios

  • Petrochemical Plants: On-site analysis shelters, explosion-proof operation rooms, electrical rooms.
  • Natural Gas Stations: Valve rooms, metering stations, explosion-proof control rooms.
  • Coal Chemical Enterprises: Explosion-proof electrical rooms, analysis monitoring stations.
  • Pharmaceutical Plants: Storage of flammable raw materials, batching rooms.
  • Military & Ordnance: Explosion-proof storage and detection rooms.
  • Grain & Oil Processing: Dust explosion-proof control rooms, dust monitoring rooms.
  • Gas Stations & Oil Depots: Explosion-proof equipment rooms, duty rooms.
  • Tunnels & Pipe Galleries: Explosion-proof distribution and monitoring cabins.

Success Cases

  • Petrochemical Analysis Shelters: Supplied 20+ units for a refining enterprise, integrating chromatographs, oxygen analyzers, sulfur analyzers. Passed explosion-proof acceptance and ran 5 years with zero failures.
  • Natural Gas Station Control Rooms: Customized positive-pressure control rooms for 12 stations along a pipeline, enabling remote monitoring and emergency operation in -35℃ extreme cold.
  • Grain Dust Explosion-Proof: Provided dust explosion-proof electrical rooms for a grain processing group, meeting Zone 21 dust requirements and solving safety in flour dust environments.

Procurement Service Guarantee

  • Reliable Supply: Own large production base, standard models in stock, no outsourcing or subcontracted orders.
  • Quality Assurance: Strict ISO9001 system with material inspection, process patrol, and final inspection. Each unit includes complete QC reports and certificates.
  • Logistics: Long-term cooperation with major logistics providers for nationwide door-to-door delivery, with full cargo insurance.
  • After-Sales: 1-year warranty, lifetime maintenance; 7×24 technical support, 48-hour on-site response (domestic); free training and operation guidance.
  • Invoicing: 13% VAT special invoice available, either with shipment or separately.

FAQ

Q: Does an explosion-proof container need an explosion-proof certificate?

A: Yes. Our products have passed inspection by national authority explosion-proof testing agencies, and we provide the corresponding model’s explosion-proof certificate, meeting safety supervision and fire acceptance requirements.

Q: Can the container be placed outdoors?

A: Yes. The container has an IP54 or higher protection rating, offering rain, dust, and corrosion resistance. It can be placed directly outside without additional shelter.

Q: What is the difference between Class ⅡB and ⅡC?

A: ⅡC is for more dangerous gases like hydrogen and acetylene, with stricter requirements. ⅡB covers propane, ethylene, and most petrochemical gases, being more cost-effective. Selection depends on the site medium.

Q: What is the delivery time?

A: Stock items ship in 3-5 days; standard customization takes 15-20 days; complex customization about 30 days, subject to contract.

Q: Is on-site installation complex?

A: No. The container ships as a whole, needing only lifting into position, power connection, and grounding. We provide on-site guidance or full installation and commissioning services.

Troubleshooting & Maintenance

Common Faults

Fault Possible Cause Solution
— — —
Internal lights not working Bulb failure, switch fault, power trip Check main power, replace bulb/switch; never open cover while energized
Fan not working Motor burned, contactor fault Power off, inspect fan motor and control circuit, replace damaged parts
Gas alarm false alarm Sensor drift, interfering gas Clean sensor intake, zero-calibrate, replace if needed
Low positive pressure Seal leak, fan airflow drop, filter blockage Check door seals and pipe joints, clean air filter, calibrate pressure sensor
A/C not cooling Refrigerant leak, compressor fault Contact professional service; do not disassemble explosion-proof A/C

Note: Repairs involving opening explosion-proof surfaces must be done by professionals after power-off, site clearance, and safety confirmation. Restore explosion-proof sealing after maintenance.

Maintenance Schedule

  • Daily: Check container appearance, door seals, indicator lights; record operating parameters.
  • Monthly: Clean air filters, check grounding connections, test alarms.
  • Quarterly: Inspect fan operation, tighten electrical connections, calibrate gas detectors.
  • Annually: Thoroughly inspect explosion-proof surfaces, replace aged seals, perform insulation test.
  • Long-term Storage: Place in dry, ventilated area; periodically power on for dehumidification; check anti-corrosion.

Conclusion

As a core product for modular hazardous-area solutions, the explosion-proof container is gradually replacing traditional civil construction due to its high safety, rapid deployment, and flexible reuse. KITOZER (Guangzhou Lain Intelligent System Development Co., Ltd.) has deep expertise in special industrial containers, offering compliant, reliable products and professional service. We provide tailored explosion-proof space solutions to support safe, efficient industrial operations.

Shopping Cart