Manufacturer: Guangzhou Lain Intelligent System Development Co., Ltd.
Service Hotline: +86 13538869979
Technical Support: +86 13538869979
Company Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou City
Official Website: https://gdlain.com
Table of Contents
TogglePreface

This manual is the official installation, wiring, and commissioning guidance document for the full series of fiber optic switch products manufactured by Guangzhou Lain Intelligent System Development Co., Ltd. It covers technical descriptions, operational specifications, troubleshooting, and acceptance criteria throughout the entire product lifecycle. This document is compiled in strict compliance with the national communications industry standard YD/T 1693-2007, the IEEE 802.3 series Ethernet standards, and the Fiber Channel FC-PI-5 international specifications. It is applicable to the deployment, operation, and maintenance of fiber optic switches across all scenarios, including data centers, industrial automation, security surveillance, smart parks, financial services, and healthcare.
All installation and commissioning personnel, as well as operations and maintenance managers, must carefully read this manual before operating the equipment, and strictly follow the standardized procedures. Failure to comply may result in equipment damage, service interruption, or personal safety risks. The company reserves the right to make technical updates to the contents of this manual. Any version changes will be made without prior notice. The latest document can be downloaded from the official website.
Chapter 1: Product Introduction

1.1 Core Definition of Fiber Optic Switch
A fiber optic switch (Fiber Switch) is a core network device that uses optical fiber as the primary physical transmission medium to achieve high-speed data frame forwarding and switching. In essence, it is a dedicated network device that deeply integrates Ethernet switching technology or Fibre Channel (FC) technology with optical fiber communications technology. Compared with traditional copper-cable Ethernet switches, a fiber optic switch uses optical modules to perform mutual conversion between electrical and optical signals. Leveraging the low loss, high bandwidth, and strong anti-interference characteristics of optical fiber media, it delivers data switching over longer distances, at higher speeds, and with greater stability and reliability.
From a technical perspective, fiber optic switches are mainly divided into two major technical routes: one is the Ethernet fiber optic switch, which follows the IEEE 802.3 standard and performs Ethernet frame forwarding based on MAC address tables, widely used in general LAN, WAN aggregation, and access scenarios. The other is the Fibre Channel switch (FC switch), which follows the ANSI T11 Fibre Channel protocol standard, specifically optimized for Storage Area Networks (SAN), featuring extremely low forwarding latency and high reliability, serving as the core hub device of storage networks.
The full series of fiber optic switches from Guangzhou Lain Intelligent System Development Co., Ltd. covers both technical routes, including all rate tiers from 100M, Gigabit, 10G, 25G, 40G, to 100G, and supports rack-mount, desktop, and DIN-rail mounting forms, meeting deployment requirements across all scenarios from access layer to core layer, and from commercial office environments to industrial-grade harsh environments.
1.2 Development History of Fiber Optic Switches
1.2.1 Global Evolution of Fiber Optic Switching Technology
The development of fiber optic switching technology is deeply coupled with the iteration of optical fiber communications technology and network switching technology, and can be broadly divided into four stages:
Initial Stage (1990-1999)
Early LANs used coaxial cable and twisted pair as the primary transmission media, with transmission distances limited to within 100 meters and rates of only 10Mbps-100Mbps. As enterprise network scales expanded, the demand for long-distance networking between buildings surged, and fiber optic media began to be introduced into LAN scenarios, giving rise to the first generation of fiber optic switches. Products at this stage were mostly 100M rate, featuring fixed optical interface designs, with functions primarily focused on basic Layer 2 forwarding, only capable of meeting simple long-distance data transmission requirements.
During the same period, in the storage domain, Fibre Channel technology entered commercial use to address the pain points of short SCSI interface transmission distances and limited connection counts. The first generation of FC switches was born, operating at 1Gbps, mainly applied to core storage networks in high-end financial institutions and large enterprises.
Rapid Adoption Stage (2000-2009)
Gigabit Ethernet technology matured, and the IEEE 802.3z standard formally published the Gigabit fiber Ethernet specification. SFP miniaturized pluggable optical modules became the industry mainstream, and Gigabit fiber optic switches rapidly proliferated. Products at this stage began to support advanced Layer 2 features such as VLAN partitioning, Spanning Tree Protocol, and link aggregation. Managed fiber optic switches became the mainstream choice for enterprise networking.
In the FC switch domain, 2Gbps and 4Gbps rates were successively commercialized, port density increased from 8 ports to 24 and 48 ports, and storage-specific functions such as Zoning and port aggregation were progressively refined. SAN network architecture became the standard deployment solution for enterprise-grade storage.
High-Speed Upgrade Stage (2010-2019)
10G Ethernet technology was commercialized on a large scale, and the cost of SFP+ optical modules dropped significantly. 10G fiber optic switches became the standard configuration for data center aggregation and core layers. Subsequently, 25G, 40G, and 100G high-speed fiber optic switches were launched successively. High-density optical modules such as QSFP+ and QSFP28 became widespread. Data center leaf-spine architectures imposed higher requirements on port density, forwarding performance, and low-latency characteristics of fiber optic switches.
FC switches iterated in parallel, with 8Gbps, 16Gbps, and 32Gbps rates becoming mainstream, supporting emerging protocols such as NVMe over Fabrics, and beginning to optimize for all-flash storage scenarios. Intelligent operations and automated configuration functions were progressively refined.
Intelligent Convergence Stage (2020 to Present)
400G and 800G ultra-high-speed fiber optic switches have entered the commercial stage, with silicon photonics technology and programmable switching chips beginning to be applied. Fiber optic switches are developing toward intelligence and convergence, supporting advanced features such as Ethernet and FC protocol convergence, SDN (Software-Defined Networking), AI-powered intelligent operations, and Telemetry, enabling network traffic visualization, automated scheduling, and fault self-healing.
Industrial-grade fiber optic switches have also developed rapidly, with wide-temperature design, strong anti-interference, and multi-protocol compatibility features continuously upgraded for industrial scenarios, becoming core network equipment for the Industrial Internet and smart manufacturing.
1.2.2 Development of the Domestic Fiber Optic Switch Industry
China’s fiber optic switch industry started slightly later than Europe and the United States, but leveraging the country’s massive communications market and data center construction demand, its development speed leads globally. In the early days, the domestic market was dominated by foreign brands such as Cisco and Brocade. As domestic manufacturers including Huawei, H3C, and Ruijie accumulated technical expertise, domestically produced fiber optic switches progressively replaced foreign brands in the mid-to-low-end market and are now breaking into the high-end core market.
As a professional domestic manufacturer of data center equipment and network equipment, Guangzhou Lain Intelligent System Development Co., Ltd. has been deeply engaged in the fiber optic switching field for many years, building a fiber optic switch product matrix covering commercial, industrial, and storage scenarios. The products have passed multiple national and industry certifications and are widely used in government, education, healthcare, finance, energy, transportation, and other industries, serving over ten thousand customers cumulatively.
1.3 Industry Value and Position of Fiber Optic Switches
In modern digital infrastructure, the fiber optic switch is the core node of network transmission links. Its value is primarily reflected in four dimensions:
Breaking Through Transmission Distance Bottlenecks
The maximum transmission distance of traditional copper twisted pair is only 100 meters, which cannot meet networking requirements between buildings, within parks, or across regions. Single-mode fiber combined with fiber optic switches can achieve repeater-less transmission of tens or even hundreds of kilometers, completely removing physical distance limitations. They are the core supporting equipment for WANs, MANs, and campus backbone networks.
Enhancing Network Transmission Bandwidth
Fiber optic media possesses nearly unlimited bandwidth potential. Current commercial fiber optic switches already support single-port rates of 400Gbps, far exceeding the maximum 40Gbps rate of copper cables. In high-bandwidth-demand scenarios such as big data, cloud computing, HD video, and AI training, fiber optic switches are the core infrastructure ensuring network throughput.
Strengthening Network Anti-Interference Capability
Fiber optic transmission uses optical signals, which are unaffected by electromagnetic interference and radio frequency interference. In strong electromagnetic environments (such as substations, factory workshops, and rail transit), lightning-prone areas, and secure communications scenarios, fiber optic switches combined with fiber optic cabling ensure the stability and security of data transmission, avoiding data errors caused by electromagnetic leakage and signal interference.
Ensuring High Network Reliability
High-end fiber optic switches support redundant power supplies, redundant fans, hot-swappable modules, link redundancy, and device stacking high-availability designs. The Mean Time Between Failures (MTBF) of the entire unit can reach hundreds of thousands of hours, meeting the 7×24-hour uninterrupted operation requirements of core businesses. They are essential equipment for critical business scenarios in finance, power, and healthcare.
1.4 Lain Fiber Optic Switch Product Positioning
The fiber optic switch products of Guangzhou Lain Intelligent System Development Co., Ltd. adhere to the positioning of “High Reliability, Easy Operation and Maintenance, Full-Scenario Coverage, and High Cost Performance,” creating differentiated product series for different user groups:
Lain Enterprise Series: Targeting general office scenarios such as SMBs, campuses, and hospitals, providing cost-effective fiber optic switches with Gigabit access and 10G uplink, meeting basic network requirements for daily office work, video surveillance, and wireless coverage.
Lain Data Center Series: Targeting IDC, cloud computing, and large enterprise data centers, providing 25G/100G/400G high-speed fiber optic switches with large buffers, low latency, and stacking virtualization, adapted to leaf-spine architectures and cloud-native scenarios.
Lain Industrial Series: Targeting industrial scenarios such as smart manufacturing, smart transportation, and energy & power, featuring wide-temperature design, industrial-grade components, and DIN-rail mounting, with strong anti-interference and multi-power redundancy characteristics, suitable for harsh industrial environments.
Lain Storage Dedicated Series: Targeting SAN storage networks, providing 16G/32G FC fiber optic switches supporting storage-specific protocols such as Zoning, NPIV, and NVMe over FC, ensuring highly reliable storage business operation.
Chapter 2: Product Composition

A fiber optic switch is a precision opto-electro-mechanical integrated device, composed of two major parts: the hardware system and the software system. The hardware system is the physical foundation for device operation, and the software system is the core that implements switching functions and management capabilities.
2.1 Hardware System Composition
The hardware of the full Lain series of fiber optic switches adopts a modular design philosophy. The core components include six major modules: chassis assembly, switching core assembly, optical interface assembly, power supply assembly, thermal dissipation assembly, and management and control assembly.
2.1.1 Chassis Assembly
The chassis is the supporting structure for all hardware components of the fiber optic switch, and also bears the functions of heat dissipation, electromagnetic shielding, and installation and fixation. Different product series have different chassis designs:
Rack-Mount Chassis
The standard 19-inch rack-mount chassis is the mainstream form, with heights divided into 1U, 2U, 4U, and other specifications. It is made of high-quality cold-rolled steel plate or aluminum alloy, with an electrostatic powder coating surface treatment, providing good wear resistance and corrosion resistance. The front of the chassis is the port panel and indicator light area; the rear is the power supply, fan, and management interface area. Ventilation ducts are designed on the upper and lower sides, forming front-to-rear or side-to-side airflow paths to ensure heat dissipation efficiency.
Rack-mount chassis are equipped with mounting ears on both sides, which can be secured to standard cabinet columns with screws. Some high-end models support rail mounting for easy slide-out maintenance. The chassis interior is designed with air guide covers and shielding springs, optimizing cooling airflow while enhancing electromagnetic shielding performance to meet EMC electromagnetic compatibility standards.
Desktop Chassis
Lightweight chassis designed for small office and weak-current cabinet deployments. They are compact in size, mostly using a plastic + metal hybrid material, with anti-slip rubber feet on the bottom, and can be placed directly on desktops or cabinet shelves. Desktop chassis typically use passive cooling or small fans, producing low noise, making them suitable for office environments.
Industrial DIN-Rail Chassis
Using aluminum alloy die-cast housings, these are structurally robust with protection ratings of IP40 and above, supporting standard 35mm DIN-rail mounting as well as wall-mounting. The chassis is designed with a fanless cooling structure, dissipating heat naturally through the metal fins of the housing, adapting to dusty, vibrating, high-temperature, and low-temperature industrial environments.
2.1.2 Switching Core Assembly
The switching core is the “brain” of the fiber optic switch, determining the device’s forwarding performance, functional characteristics, and expansion capabilities. The core components include the switching chip, central processing unit, memory, and storage units:
Switching ASIC Chip
The Application-Specific Integrated Circuit (ASIC) switching chip is the core of data forwarding, responsible for the complete process of data frame reception, parsing, table lookup, and forwarding. All high-speed data forwarding is processed at line rate by the hardware chip without CPU involvement, ensuring low latency and high throughput.
Different Lain product series use switching chips of corresponding specifications: access layer products use mature Gigabit switching chips supporting full line-rate non-blocking forwarding; aggregation and core layer products use high-end 10G and 100G switching chips supporting large table entries, large buffers, and multi-layer routing and switching functions; industrial-grade products use dedicated switching chips with industrial temperature ranges to ensure stable operation under extreme temperatures.
Central Processing Unit (CPU)
The CPU is the control core of the switch, responsible for running the operating system, processing management commands, executing protocol calculations, maintaining address tables and routing tables, and responding to management interface operations. High-end switches use multi-core high-performance processors to ensure smooth operation of complex protocol computation and intelligent management functions; entry-level products use single-core or dual-core low-power processors to meet basic management requirements.
Memory and Storage Units
Memory (DRAM) is used to run the operating system and cache temporary data and table entries. Memory capacity directly affects the switch’s table entry scale and multitasking capabilities. Storage units (Flash/EEPROM) are used to store the operating system firmware, configuration files, and log files, with capacities ranging from a few MB to several GB. High-end models support dual storage partitions for firmware backup and smooth upgrades.
2.1.3 Optical Interface Assembly
The optical interface is the core component that distinguishes fiber optic switches from copper-cable switches. It is responsible for optical signal access and opto-electrical conversion, consisting of three parts: optical module slots, optical modules, and fiber optic connectors:
Optical Module Slots
Slots are physical interfaces soldered onto the switch motherboard, corresponding to different specifications of optical modules. Common types include SFP, SFP+, SFP28, QSFP+, QSFP28, and QSFP-DD. The slots use precision spring designs to ensure good contact after optical module insertion, and are equipped with latching mechanisms to secure the optical modules and prevent loosening.
Some fiber optic switches feature combo (optical/electrical multiplexed) port designs, where the same port can accept either an optical module for fiber connection or an RJ45 connector for copper cable connection, improving deployment flexibility.
Optical Modules (Optical Transceivers)
Optical modules are the core components that perform opto-electrical conversion. At the transmitting end, electrical signals are converted to optical signals and coupled into the fiber; at the receiving end, optical signals from the fiber are restored to electrical signals. Optical modules are pluggable components, and users can flexibly select them based on transmission distance, rate, and fiber type.
By rate, optical modules can be divided into 100M SFP, Gigabit SFP, 10G SFP+, 25G SFP28, 40G QSFP+, and 100G QSFP28. By fiber type, they can be divided into multi-mode optical modules (850nm wavelength) and single-mode optical modules (1310nm/1550nm wavelength). By transmission distance, they can be divided into short-reach (within 550m), medium-reach (10-40km), and long-reach (above 80km) specifications.
Fiber Optic Connector Interfaces
The fiber optic interfaces of optical modules come in various types including LC, SC, ST, and MPO. The current mainstream is the LC small-form-factor connector, which offers high density and small size, suitable for high-density port deployments. SC large-form-factor connectors are more commonly seen on early 100M and Gigabit equipment. MPO interfaces are used for 40G/100G and above multi-fiber parallel transmission scenarios.
2.1.4 Power Supply Assembly
The power supply assembly provides stable DC power to the entire switch and is the foundation for reliable device operation. The full Lain series of fiber optic switches adopts high-reliability power supply solutions, divided into two forms: built-in power supplies and pluggable power supplies:
Built-in Power Supplies
Entry-level and desktop switches mostly use built-in switching power supplies, directly connected to 220V AC mains, converting to the low-voltage DC required by the equipment. Built-in power supplies are compact and cost-effective, with multiple protection mechanisms including over-voltage, over-current, short-circuit, and over-temperature protection.
Pluggable Redundant Power Supplies
Mid-to-high-end rack-mount and industrial switches adopt pluggable power module designs, supporting 1+1 redundant backup. When one power supply fails, the other seamlessly takes over power delivery without affecting business operations. Power modules support hot-swapping, allowing failed power supplies to be replaced without shutting down the device, improving system availability.
Industrial-grade switches support wide-voltage DC input (e.g., DC12-57V), adapting to multiple power supply standards found at industrial sites, and support dual or even triple power supply redundancy to address unstable power conditions in industrial environments.
2.1.5 Thermal Dissipation Assembly
During switch operation, the switching chip, power supply, and optical modules all generate heat. The thermal dissipation assembly ensures the equipment operates within a reasonable temperature range, preventing accelerated component aging or failure caused by high temperatures. Thermal dissipation solutions are divided into two categories: passive cooling and active cooling:
Passive Cooling
Fanless design, dissipating heat naturally through the chassis metal housing and heat dissipation fins. It offers the advantages of no noise, high reliability, and dust resistance, and is mostly used in industrial-grade switches and low-power entry-level switches. Passive cooling has certain requirements for ambient temperature, and good ventilation around the equipment must be ensured.
Active Cooling
Using fans for forced-air cooling, this is the mainstream thermal dissipation solution for rack-mount switches. The fan assembly is designed at the rear or side of the chassis, forming a front-to-rear airflow path. Cold air enters from the front panel, passes through the core heat-generating components, and exits from the rear, carrying heat away.
High-end switches use intelligent speed-regulating fans that automatically adjust fan speed based on device temperature, reducing speed to lower noise and power consumption in low-temperature environments. They also support hot-swappable fans; if a single fan fails, the remaining fans can temporarily maintain cooling, and the failed fan can be replaced online. Some high-end models feature separate front-to-rear and side-to-side airflow path designs, achieving cold/hot air isolation and adapting to data center cold-aisle/hot-aisle layouts.
2.1.6 Management and Control Assembly
The management assembly is used to implement switch configuration, monitoring, and maintenance. The main interfaces include:
Console Port
An RJ45 or Mini USB serial interface, which is the local management interface of the switch. By connecting a dedicated Console cable to a computer’s serial port, users can perform initial configuration, troubleshooting, and system recovery through the Command Line Interface (CLI) even when the device has no network configuration. It is the most fundamental management channel of a switch.
Management Port (MGMT)
An independent Ethernet RJ45 interface, dedicated to device management and not carrying business data. After configuring a management IP address, the switch can be remotely managed through Telnet, SSH, Web interface, and SNMP, enabling remote configuration, status monitoring, and firmware upgrades.
USB Interface
Some models are equipped with USB interfaces, which can be used to insert USB flash drives to import configuration files, upgrade firmware, and export system logs, facilitating device maintenance in field environments without network access.
Reset Button
A concealed reset button on the device panel. Pressing and holding it restores the device to factory default configuration, used in scenarios such as forgotten passwords or configuration errors preventing login. The reset operation will erase all custom configurations and should be performed with caution.
Status Indicator Lights
The panel is equipped with power indicator lights, system operation indicator lights, and port status indicator lights. Through light colors and blinking states, the device operation status is intuitively displayed, allowing operations and maintenance personnel to quickly assess the health of the device.
2.2 Software System Composition
The software system of a fiber optic switch is the network operating system, serving as the carrier for device function implementation. Lain fiber optic switches use the independently developed LA-OS network operating system, which features high stability, rich functionality, and ease of use. It is divided into three layers: the system kernel layer, the protocol function layer, and the management interface layer.
2.2.1 System Kernel Layer
The kernel layer is the core foundation of the operating system, developed based on a trimmed and optimized Linux kernel, with fundamental capabilities including task scheduling, memory management, hardware drivers, and file systems. It is deeply optimized for network switching scenarios to ensure real-time performance and stability, while implementing driver adaptation for hardware switching chips, seamlessly integrating hardware forwarding capabilities with the software protocol stack.
The kernel layer also includes device driver modules, supporting drivers and status monitoring for various optical modules, power supplies, fans, and sensors, enabling real-time collection and reporting of hardware status.
2.2.2 Protocol Function Layer
The protocol function layer is the implementation layer of the switch’s core business capabilities, containing a rich set of network protocol stacks and functional modules:
Layer 2 Switching Protocol Module
Includes basic Ethernet switching functions, MAC address learning and aging, VLAN partitioning (802.1Q), Spanning Tree Protocol (STP/RSTP/MSTP), link aggregation (LACP/static aggregation), port mirroring, broadcast storm suppression, and QoS quality of service.
Layer 3 Routing Protocol Module
Layer 3 switches include a routing function module, supporting static routing and dynamic routing protocols such as RIP, OSPF, and BGP, as well as VRRP virtual router redundancy, enabling cross-subnet data forwarding and network redundancy backup.
Security Function Module
Includes port security, 802.1x authentication, ACL access control lists, ARP protection, DHCP Snooping, and anti-DOS attack security functions, ensuring network access security and operational stability.
Storage Dedicated Protocol Module
FC fiber channel switches include dedicated protocol modules, supporting FCP protocol, Zoning, NPIV port virtualization, FCIP, NVMe over FC, and other storage-specific protocols, meeting SAN network deployment requirements.
Industrial Protocol Module
Industrial-grade fiber optic switches support transparent transmission of industrial bus protocols such as Modbus TCP, Profinet, and EtherNet/IP, meeting industrial automation equipment interconnection requirements, and also support industrial ring network protocols such as ERPS and MRP, achieving millisecond-level ring network fault self-healing.
2.2.3 Management Interface Layer
The management interface layer provides multiple management methods for operations and maintenance personnel, implementing device configuration, monitoring, and operations:
Command Line Interface Management (CLI)
A command line interface accessible via Console port or SSH/Telnet, supporting full-featured configuration, suitable for professional operations and maintenance personnel. Commands are clear and execution is efficient, supporting batch import and export of configurations.
Web Graphical Management Interface
A browser-based visual management interface that allows port configuration, VLAN partitioning, status monitoring, and firmware upgrades through graphical menus. No command memorization is required, lowering the operations and maintenance threshold, suitable for non-professional network administrators.
SNMP Network Management Interface
Supports SNMP v1/v2c/v3 protocols and can be integrated into third-party network management platforms (such as the Lain intelligent network management system) for centralized monitoring, alarm management, and performance statistics of batch devices, suitable for large-scale network deployment scenarios.
Automation Interface
Supports automation management interfaces such as REST API and NETCONF/YANG, which can interface with SDN controllers and cloud management platforms to implement automated network configuration and orchestration, adapting to cloud computing and data center automated operations and maintenance requirements.
Chapter 3: Product Classification
Fiber optic switch products are rich in variety and can be classified according to multiple dimensions including technical protocol, transmission rate, application scenario, architecture form, and manageability. Different classification dimensions correspond to different product selection requirements.
3.1 Classification by Core Technical Protocol
3.1.1 Ethernet Fiber Optic Switches
Ethernet fiber optic switches are the category with the largest market inventory and the widest application. They follow the IEEE 802.3 Ethernet standard, implement data switching based on the TCP/IP protocol stack, and are primarily used to build data communications networks.
Ethernet fiber optic switches can be further subdivided by application layer:
Layer 2 Fiber Optic Switches: Support only Layer 2 data forwarding, implementing data switching based on MAC addresses. Functions are relatively simple and cost is lower, suitable for access layer and terminal device access scenarios such as surveillance camera access and office computer access.
Layer 3 Fiber Optic Switches: Add Layer 3 routing functions on top of Layer 2 switching, supporting static routing and dynamic routing protocols, enabling data forwarding across VLANs and subnets. Suitable for network aggregation layers and small network core layers, undertaking routing forwarding and regional network aggregation functions.
Multi-Layer Fiber Optic Switches: Support full Layer 2/3/4 functionality, with rich security, QoS, multicast, and virtualization features. They offer strong performance and large table capacity, suitable for large network core layers and data center core nodes.
3.1.2 Fibre Channel (FC) Switches
FC switches are specifically designed for Storage Area Networks (SAN), following the ANSI T11 Fibre Channel protocol, dedicated to data transmission between servers and storage devices, and are the core equipment for building FC-SAN.
Compared with Ethernet switches, FC switches offer lower forwarding latency (microsecond level), higher reliability, and more comprehensive storage-dedicated functions, ensuring stable and efficient storage I/O. By functional tier, they can be divided into:
Entry-Level FC Switches: Fixed port configurations of 8 or 24 ports, supporting basic Zoning functions, suitable for small SAN environments and departmental storage networks.
Enterprise-Class FC Switches: 48 and 96-port high-density configurations, supporting advanced zoning, NPIV, link aggregation, and performance monitoring, suitable for core storage networks of mid-sized enterprises.
Director-Class FC Switches: High-end rack-mount chassis, supporting hot-swappable service line cards, redundant control processors, fully redundant power supplies and fans, port densities reaching hundreds of ports, with carrier-class reliability, suitable for large data centers and cloud service provider core storage networks.
3.2 Classification by Port Transmission Rate
Rate is one of the most core performance indicators of fiber optic switches. Different rate tiers correspond to different bandwidth requirement scenarios:
3.2.1 100M Fiber Optic Switches
Single port rate is 100Mbps, mostly Fast Ethernet standard, with optical modules using 100M SFP specifications. Products are mostly 8, 16, or 24-port configurations, predominantly Layer 2 unmanaged types, with low cost, suitable for long-distance access scenarios with low bandwidth requirements, such as legacy campus retrofits and long-distance security surveillance access.
Currently, 100M fiber optic switches are gradually being replaced by Gigabit products, and are only used in some existing project retrofits and low-cost scenarios.
3.2.2 Gigabit Fiber Optic Switches
Single port rate is 1000Mbps (1Gbps), the mainstream rate for current access layers, with optical modules using Gigabit SFP specifications, supporting 10/100/1000Mbps auto-negotiation.
Gigabit fiber optic switches offer flexible port configurations, including 8-fiber + 2-copper, 16-fiber + 2-copper, 24-fiber + 4-copper, and 48-fiber + 4-10G-uplink specifications, meeting all-optical access and hybrid optical-electrical networking requirements. Widely used in enterprise office access, security surveillance access, and building aggregation scenarios, they are the category with the largest market installed base.
3.2.3 10G Fiber Optic Switches
Single port rate is 10Gbps, with optical modules using SFP+ specifications, the mainstream rate for current aggregation layers and data center access layers. 10G fiber optic switches are divided into two categories: pure 10G port configurations and “Gigabit access + 10G uplink” hybrid configurations:
Pure 10G Port Models: 24 or 48-port 10G optical ports, paired with 40G/100G uplink ports, used for data center leaf nodes and core aggregation.
Hybrid Configuration Models: 24/48 Gigabit optical ports + 4/8 10G uplink optical ports, used for Gigabit access-layer uplink aggregation, resolving access bandwidth bottlenecks.
10G fiber optic switches generally support Layer 3 routing functions with rich advanced features and are core equipment for medium-to-large networks.
3.2.4 25G/40G Fiber Optic Switches
25G and 40G are mainstream high-speed tiers for data centers. 25G uses SFP28 optical modules, and 40G uses QSFP+ optical modules.
25G fiber optic switches are mainly used for server access, adapting to servers with 25G network interface cards. They provide 2.5 times the bandwidth of 10G while remaining compatible with 10G rates for flexible deployment. 40G fiber optic switches are mostly used for aggregation and core layer interconnection, or as storage network backbone links.
These products are mainly applied in cloud computing data centers, supercomputing centers, and core computer rooms of large enterprises, with high requirements for forwarding performance, port density, and low latency.
3.2.5 100G and Above Ultra-High-Speed Fiber Optic Switches
Includes 100G and 400G rates. 100G uses QSFP28 optical modules, and 400G uses QSFP-DD or OSFP optical modules, representing the current core backbone rates of high-end data centers.
Ultra-high-speed fiber optic switches use high-end programmable switching chips with ultra-large switching capacity, large buffers, and low latency characteristics. They support a rich set of data center features such as ECMP equal-cost multi-path routing, VXLAN, ROCEv2, and intelligent traffic scheduling, adapted to ultra-high-bandwidth scenarios such as AI training, distributed storage, and high-density virtualization.
3.3 Classification by Application Scenario and Protection Rating
3.3.1 Commercial-Grade Fiber Optic Switches
Also known as enterprise-grade or data center-grade fiber optic switches, these operate in standard data centers and office environments, with ambient temperatures of 0-45°C, protection rating IP20, fan cooling, and rack-mount or desktop installation.
Commercial-grade products offer rich functionality, high port density, and moderate cost, making them the mainstream choice for data centers, enterprise computer rooms, and office buildings. The Lain Enterprise series and Data Center series both fall into this category.
3.3.2 Industrial-Grade Fiber Optic Switches
Designed for harsh industrial environments, using industrial-grade components, with a wide operating temperature range (typically -40°C to 85°C), protection rating IP40 and above, and strong resistance to electromagnetic interference, vibration, and dust.
Industrial-grade fiber optic switches are mostly DIN-rail mounted, support wide-voltage DC power input and multiple power supply redundancy, and support industrial ring network protocols. They can operate stably in harsh environments such as factory workshops, outdoor cabinets, mines, substations, and rail transit. All Lain industrial-grade fiber optic switches pass EMC industrial level 4 certification, meeting the requirements of various industrial scenarios.
3.3.3 Outdoor Fiber Optic Switches
Designed for outdoor open-air deployment scenarios, with chassis protection ratings up to IP65/IP67, fully dustproof and waterproof, supporting wide-temperature operation, equipped with lightning and surge protection, and can be installed directly on outdoor poles or in equipment boxes without the need for data center room protection.
Outdoor fiber optic switches are mostly used in smart street lighting, safe city, and outdoor surveillance scenarios, avoiding the cost of building data center rooms and offering flexible deployment.
3.4 Classification by Device Manageability
3.4.1 Unmanaged Fiber Optic Switches
Also known as plug-and-play switches, these require no configuration and are ready to use once powered on. All ports are in the same broadcast domain by default. Unmanaged products have a simple structure and low cost, requiring no professional operations and maintenance personnel, suitable for small networks and simple access scenarios such as small offices and micro surveillance systems.
Unmanaged fiber optic switches typically do not support advanced functions such as VLAN and routing, and their network scalability and security are weaker, making them unsuitable for medium-to-large network deployments.
3.4.2 Managed Fiber Optic Switches
Support configuration management, allowing functional configuration and status monitoring through CLI, Web, or network management platforms, with rich features such as VLAN, link aggregation, and security policies, enabling customized network architectures based on business requirements.
Managed fiber optic switches are the mainstream choice for medium-to-large networks and can be further divided into network-managed (Web + CLI basic management) and intelligent types (supporting Layer 3 routing, SNMP, automation interfaces, and other full features), meeting management requirements at different levels.
3.5 Classification by Architecture Form
3.5.1 Fixed-Port Fiber Optic Switches
Port quantity and types are fixed and cannot be expanded. Fixed-port switches are the most common form, with lower cost and simpler deployment, suitable for scenarios with clearly defined port requirements, such as access layers with a fixed number of terminals.
Most of Lain’s access layer and aggregation layer fiber optic switches use fixed-port designs, with port specifications covering the full series from 8 to 48 ports.
3.5.2 Chassis Modular Fiber Optic Switches
Adopt a modular architecture of chassis + service line cards. The chassis provides power supplies, fans, and control processor units, while service line cards can be flexibly selected based on requirements, supporting optical port line cards and electrical port line cards of different rates and types.
Chassis switches offer exceptional scalability, allowing port quantity and types to be expanded on demand. They also support control processor redundancy and power supply redundancy, with extremely high reliability, suitable for core layers of large networks and data center core nodes, protecting users’ long-term investment.
3.5.3 Stackable Fiber Optic Switches
Support dedicated stacking interfaces or virtualized stacking over regular ports. Multiple switches connected via stacking cables can be logically virtualized into a single switch for unified management and unified forwarding, expanding port density while simplifying operations and maintenance.
Stacking technology enables cross-device link aggregation and redundancy backup, improving network reliability. It is a cost-effective solution for SMBs to expand network scale, with lower cost and more flexible deployment compared to chassis switches.
Chapter 4: Product List
4.1 Standard Packing List
The standard configuration of the full Lain series of fiber optic switches includes the following items at the time of shipment. Upon receiving the equipment, users should check each item against the list. If anything is missing or damaged, please contact the supplier promptly:
| No. | Item Name | Quantity | Remarks |
|---|---|---|---|
| 1 | Fiber optic switch main unit | 1 unit | Corresponds to the ordered model, including default port configuration |
| 2 | AC power cord | 1 piece | Single power supply models include 1; redundant power supply models are configured according to the number of power supplies |
| 3 | Serial configuration cable (Console cable) | 1 piece | RJ45 to RS232 or USB to RJ45, used for local configuration |
| 4 | Rack mounting ears | 1 pair | Standard for rack-mount models, including matching mounting screws |
| 5 | Rubber feet | 4 pieces | Standard for desktop models; optional for rack-mount models |
| 6 | Product certificate of conformity | 1 copy | Includes factory inspection and quality certification mark |
| 7 | Product warranty card | 1 copy | Fill in product information and warranty terms |
| 8 | This manual | 1 copy | Paper version; electronic version available for download from the official website |
| 9 | Dust plugs | Several | Corresponding to the number of ports without optical modules installed, protecting port cleanliness |
4.2 Optional Accessories List
The following accessories are optional purchases that users can order separately based on actual deployment requirements:
4.2.1 Optical Module Category
- Gigabit multi-mode SFP optical module: 850nm wavelength, LC interface, transmission distance 550m, compatible with OM2 multi-mode fiber
- Gigabit single-mode SFP optical module: 1310nm wavelength, LC interface, transmission distance selectable from 10km/20km/40km/80km
- 10G multi-mode SFP+ optical module: 850nm wavelength, LC interface, transmission distance 300m, compatible with OM3/OM4 multi-mode fiber
- 10G single-mode SFP+ optical module: 1310nm/1550nm wavelength, LC interface, transmission distance selectable from 10km/20km/40km/80km
- 25G SFP28 optical module: multi-mode/single-mode optional, corresponding to different transmission distances
- 40G QSFP+ optical module: SR4 multi-mode, LR4 single-mode, and other specifications optional
- 100G QSFP28 optical module: SR4, LR4, ER4, and other specifications optional
- Fiber patch cords: LC-LC, LC-SC, SC-SC, and other interface types, single-mode/multi-mode optional, length customized as needed
- Fiber optic couplers and fiber flange adapters: used for fiber splicing and extension
4.2.2 Installation and Power Accessories
- Redundant power supply modules: suitable for models supporting redundant power supplies, 1+1 backup for enhanced reliability
- DC power supply modules: suitable for industrial models and data center DC power scenarios, supporting DC48V and other inputs
- DIN-rail mounting kit: standard for industrial models; rack-mount models can optionally be fitted with rail mounting brackets
- Cabinet cable managers: used for organizing fiber and power cables, improving cabinet tidiness
- Fiber optic distribution frames (ODF): used for fiber splicing and patching in data center rooms, used in conjunction with fiber optic switches
4.2.3 Operations and Maintenance Tool Accessories
- Fiber optic cleaning pens and cleaning cloths: used to clean optical modules and fiber end faces
- Optical power meters and visual fault locators (red light pens): used for fiber link testing and fault troubleshooting
- Anti-static wrist straps and anti-static gloves: protect electrostatic-sensitive components during installation and maintenance
- Lain intelligent network management system software: used for centralized management and monitoring of batch devices
4.3 Tool Preparation List
Before installing and commissioning a fiber optic switch, the following tools and materials should be prepared to ensure smooth construction:
- Installation tools: Phillips screwdriver (PH2), flat-head screwdriver, diagonal cutters, wire strippers, torque screwdriver (for tightening screws on high-end models), marker pen, label paper
- Cleaning tools: lint-free wipes, anhydrous ethanol, fiber optic cleaning pens, compressed air dust remover
- Testing tools: optical power meter, visual fault locator, network cable tester, laptop computer (with serial port or USB-to-serial adapter)
- Protective equipment: anti-static wrist strap, anti-static gloves, safety helmet (for data center room construction), work gloves
- Auxiliary materials: nylon cable ties, fiber optic corrugated conduit, spiral wrap tubing, insulating tape, fiber optic protective sleeves
Chapter 5: Product Operating Principles
5.1 Core Operating Principles of Ethernet Fiber Optic Switches
The core operating logic of an Ethernet fiber optic switch is Layer 2 data forwarding based on MAC addresses, combined with opto-electrical signal conversion to achieve data transmission over fiber optic media. The overall workflow can be divided into four core stages: opto-electrical conversion, data frame processing, MAC address learning and forwarding decision, and data transmission.
5.1.1 Opto-Electrical Signal Conversion Principles
Fiber optic transmission uses optical signals, while the switch internally processes electrical signals. Therefore, the optical module performs the core function of opto-electrical conversion and is the foundation of fiber optic switch operation:
Receiving Direction (Optical → Electrical)
The optical signal transmitted by the remote device through the fiber arrives at the receiving end of the local optical module. The photodetector (PIN diode or APD diode) converts the optical signal into a weak electrical signal. After amplification, shaping, and Clock and Data Recovery (CDR) circuit processing, it is restored to a standard digital electrical signal and transmitted to the switching chip for processing.
Transmitting Direction (Electrical → Optical)
The digital electrical signal output by the switching chip is sent to the transmitting end of the optical module, driving the laser diode (LD) or light-emitting diode (LED) to emit an optical signal at the corresponding wavelength. The optical signal is coupled into the fiber core through a coupling lens and transmitted along the fiber to the remote device.
Optical modules at Gigabit rates and above mostly use laser diodes as light sources, offering stable output power and long transmission distances. Low-speed multi-mode modules partially use light-emitting diodes for lower cost.
The opto-electrical conversion process of optical modules operates bidirectionally simultaneously. When a fiber link uses dual-fiber bidirectional transmission, one fiber is responsible for transmitting and one for receiving. In single-fiber bidirectional transmission, different wavelengths of optical signals achieve bidirectional transmission over the same fiber.
5.1.2 Data Frame Reception and Processing
After the switching chip receives an Ethernet data frame in electrical signal form from the optical module, it first performs frame validation and preprocessing:
Frame Synchronization and Parsing: Identifies the preamble and Start Frame Delimiter (SFD) of the data frame to achieve frame synchronization, then parses the frame header information, extracting fields such as source MAC address, destination MAC address, VLAN tag, and frame type.
Frame Validation: Calculates the Frame Check Sequence (FCS) and compares it with the checksum value at the end of the frame to determine whether errors occurred during transmission. If the validation fails, the frame is discarded directly and the error counter is incremented. If validation passes, processing proceeds to the next step.
Frame Filtering: Based on configured security rules, ACL access control lists, VLAN membership, and other parameters, determines whether the frame is permitted to be received on that port. Frames that do not meet the rules are discarded directly, ensuring network security.
5.1.3 MAC Address Learning and Forwarding Decision
This is the core stage of intelligent switch forwarding. The switch achieves directed data forwarding by maintaining a MAC address table, rather than the broadcast-style transmission of a hub.
MAC Address Learning
The switch extracts the source MAC address and receiving port number from the data frame and queries the local MAC address table. If the MAC address does not exist, the “MAC address – port number – VLAN” correspondence is added to the address table and an aging timer is started. If it already exists, the aging timer is refreshed.
Through continuous learning, the switch progressively establishes the correspondence between MAC addresses and ports across the entire network. Address table capacity ranges from several thousand to several hundred thousand entries, with high-end switches supporting larger address table capacities.
Forwarding Decision
The switch extracts the destination MAC address from the data frame and queries the MAC address table:
- If the destination MAC address exists in the table and the corresponding port is not the same as the receiving port, the frame is forwarded to the corresponding destination port, known as unicast forwarding.
- If the destination MAC address does not exist in the table, the frame is flooded to all ports in the same VLAN except the receiving port, known as unknown unicast flooding. After the destination device responds, the switch learns the port corresponding to that MAC address.
- If the destination MAC address is a broadcast address (all Fs) or a multicast address, the frame is broadcast/multicast forwarded to all ports in the same VLAN.
5.1.4 Data Frame Transmission
After the switching chip completes the forwarding decision, it sends the data frame to the transmit queue of the corresponding egress port. After QoS scheduling, the frame is sent to the corresponding optical module, converted to an optical signal, coupled into the fiber, and transmitted to the next-hop device.
Depending on the switching mode of the switch, the timing of forwarding processing also differs. There are three common switching modes:
Store-and-Forward Mode
The switch fully receives the entire data frame, stores it in buffer memory, completes validation and processing, and then forwards it. The advantage is the ability to validate frame integrity, filter error frames, and support forwarding between ports of different rates. The disadvantage is higher forwarding latency, and the latency varies with frame length.
Currently, the vast majority of managed switches use store-and-forward mode. All Lain managed fiber optic switches default to this mode.
Cut-Through Mode
The switch begins forwarding immediately after receiving only the preamble and destination MAC address (approximately 14 bytes) of the data frame, without waiting for the complete frame to be received. The advantage is extremely low forwarding latency with fixed latency independent of frame length. The disadvantage is the inability to validate frame integrity, meaning error frames are also forwarded, and forwarding between ports of different rates is not supported.
This mode is mostly used in scenarios with extremely high latency requirements, such as high-frequency trading in finance.
Fragment-Free Mode
Also known as modified cut-through mode, this is a compromise between the two modes above. The switch receives the first 64 bytes before forwarding. Since collided fragment frames in Ethernet are all shorter than 64 bytes, this mode filters out most error fragment frames while maintaining relatively low forwarding latency.
5.1.5 Layer 3 Routing and Forwarding Principles
In addition to Layer 2 switching functions, Layer 3 fiber optic switches also have Layer 3 routing and forwarding capabilities, enabling data forwarding across VLANs and subnets.
Layer 3 forwarding operates at two levels:
First-Packet CPU Forwarding: When the first cross-subnet data packet arrives, the switching chip cannot process it directly and uploads it to the CPU routing protocol stack. The CPU looks up the next-hop address in the routing table, completes ARP resolution, determines the egress port and Layer 2 encapsulation information, and then forwards the packet. At the same time, the forwarding entry is written into the hardware forwarding table.
Subsequent-Packet Hardware Forwarding: When subsequent packets of the same flow arrive, the switching chip directly queries the hardware forwarding table and completes fast forwarding without CPU involvement, achieving line-rate Layer 3 forwarding.
This “route once, switch many” mechanism not only implements routing functionality but also ensures forwarding performance, and is the core advantage of Layer 3 switches.
Chapter 5 Technical Principles (Continued)
5.2 FC Fiber Channel Switch Operating Principles
FC Fiber Channel switches are specifically designed for Storage Area Networks (SAN). Their operating principles share similarities with Ethernet switches, but they are based on the Fiber Channel protocol stack and have been deeply optimized for storage I/O operations.
5.2.1 Fiber Channel Protocol Fundamentals
Fiber Channel is a high-speed serial transmission protocol that employs a layered architecture. From bottom to top, it is divided into five layers: FC-0 (Physical Layer), FC-1 (Encoding Layer), FC-2 (Framing Protocol Layer), FC-3 (Common Services Layer), and FC-4 (Upper Layer Protocol Mapping Layer).
- FC-0: Defines physical media specifications, optical modules, connectors, transmission rates, and other physical layer parameters. Supports multi-mode fiber, single-mode fiber, and copper cable media.
- FC-1: Defines 8b/10b or 64b/66b encoding schemes to achieve DC balance and clock synchronization, ensuring reliable data transmission.
- FC-2: Defines frame structure, flow control, service classes, and switching mechanisms. This is the core layer of the protocol, where data is transmitted in frame units.
- FC-3: Defines advanced features such as encryption and multi-link aggregation.
- FC-4: Defines upper-layer protocol mapping, mapping protocols such as SCSI, NVMe, and IP onto Fiber Channel for transmission. The most common is FCP (SCSI over FC).
5.2.2 FC Switch Data Forwarding Process
FC switches perform data forwarding based on Fiber Channel IDs (FC IDs). The overall process is as follows:
Device Login and Address Assignment
After server HBA cards and storage devices connect to an FC switch, they first perform FLOGI (Fabric Login). The switch assigns a unique 24-bit FC ID to each connected device, similar to an IP address in Ethernet. Meanwhile, devices perform PLOGI (Port Login) with each other to establish communication connections.
Address Learning and Routing Table Establishment
The FC switch learns the address mapping relationships of corresponding ports by examining the source FC ID in received frame headers, building a FIB (Forwarding Information Base) table that records the mapping between FC IDs and corresponding ports. In multi-switch cascaded Fabric networks, switches exchange routing information between themselves through routing protocols (such as FSPF) to construct a network-wide routing table.
Frame Reception and Forwarding
Upon receiving an FC frame, the switch parses the destination FC ID in the frame header, queries the FIB table, identifies the corresponding egress port, and forwards the frame out. FC switches also employ hardware wire-speed forwarding with extremely low latency, typically at the microsecond level, meeting the low-latency requirements of storage I/O.
Flow Control and Assurance
The FC protocol incorporates a comprehensive end-to-end flow control mechanism. It uses a credit-based flow control mechanism to prevent packet loss caused by buffer overflow, ensuring reliable transmission of storage data. This is also a key reason why FC switches remain irreplaceable in the storage domain.
5.2.3 Zoning Operating Principles
Zoning is a core function of FC switches, similar to VLANs in Ethernet. It is used to divide devices in a SAN network into different zones. Only devices within the same zone can communicate with each other, while different zones are isolated, enhancing the security and stability of the storage network.
Zoning is divided into hard zoning and soft zoning:
- Hard Zoning: Based on physical port partitioning. All devices under the same port belong to the same zone. Isolation is thorough, and performance is unaffected.
- Soft Zoning: Based on device WWN (World Wide Name) partitioning. Devices connected to any port belong to the corresponding zone. Deployment is flexible and not restricted by physical location.
The KITOZER FC series fiber optic switches support both zoning methods simultaneously and can be configured in a mixed manner to meet the requirements of different scenarios.
5.3 Core Function Technical Principles
5.3.1 VLAN Operating Principles
A Virtual Local Area Network (VLAN) logically divides a physical LAN into multiple broadcast domains by inserting 802.1Q tags into Ethernet frames. Different VLANs cannot directly communicate at Layer 2, enhancing network security and reducing the impact of broadcast storms.
Fiber optic switches support multiple VLAN partitioning methods, including port-based VLANs, MAC-based VLANs, and protocol-based VLANs. Port-based VLAN is the most commonly used method. Switch ports are categorized into three types: Access ports, Trunk ports, and Hybrid ports:
- Access Port: Belongs to a single VLAN and is used to connect terminal devices. Frames sent out do not carry VLAN tags.
- Trunk Port: Allows tagged frames from multiple VLANs to pass through. Used for inter-switch cascading to enable same-VLAN communication across devices.
- Hybrid Port: Flexibly configured to allow frames from multiple VLANs to pass through, either tagged or untagged, adapting to complex networking scenarios.
5.3.2 Spanning Tree Protocol Principles
Spanning Tree Protocol (STP/RSTP/MSTP) is used to resolve Layer 2 network loops. By logically blocking certain ports, it prunes a ring network into a loop-free tree topology. Additionally, when the primary link fails, it automatically opens blocked ports to achieve link backup.
RSTP (Rapid Spanning Tree Protocol) optimizes the convergence mechanism based on STP, reducing convergence time from tens of seconds to the second level. MSTP (Multiple Spanning Tree Protocol) supports multiple spanning tree instances, allowing different VLANs to use different paths, achieving link load sharing.
5.3.3 Link Aggregation Principles
Link Aggregation (LACP) bundles multiple physical ports into a single logical aggregation group, increasing link bandwidth while providing link redundancy. When a physical link within the aggregation group fails, traffic is automatically distributed to the remaining healthy links without interrupting services.
Fiber optic switches support static aggregation and dynamic LACP aggregation, as well as cross-device aggregation (in conjunction with stacking or clustering technologies). A maximum of 8 links can be aggregated into one group, multiplying bandwidth accordingly.
Chapter 6 Product Technical Specifications
The KITOZER full series of fiber optic switches covers multiple product tiers. The following are the core technical specifications for each series. For specific model parameters, please refer to the corresponding model’s datasheet or contact official technical support.
6.1 General Hardware Specifications
6.1.1 Chassis and Installation Parameters
| Parameter | Enterprise Rack Series | Industrial DIN-Rail Series | Desktop Series |
|---|---|---|---|
| Chassis Material | High-quality cold-rolled steel plate, electrostatic powder coating | Aluminum alloy die-cast housing | Flame-retardant engineering plastic + metal base plate |
| Mounting Method | 19-inch standard rack mounting, desktop placement supported | 35mm DIN rail mounting, wall mounting | Desktop placement, wall mounting optional |
| Device Height | 1U/2U/4U | 1U/2U rail height | Compact, within 1U |
| Dimensions (W×D×H) | 440mm×280mm×44mm (typical 1U) | 155mm×110mm×55mm (typical 8-port) | 280mm×150mm×30mm (typical 8-port) |
| Weight | 3.5kg (typical 1U 24-port) | 1.2kg (typical 8-port) | 0.8kg (typical 8-port) |
6.1.2 Power Supply Parameters
| Parameter | AC Power Models | DC Power Models | Industrial Wide-Voltage Models |
|---|---|---|---|
| Input Voltage | AC 100-240V, 50/60Hz | DC -48V / DC 24V | DC 12-57V wide range |
| Rated Power | 15W-150W (varies by port count and speed) | 20W-200W | 10W-80W |
| Redundancy Support | Mid-to-high-end models support 1+1 hot-swappable redundancy | Supports 1+1 redundancy | Supports dual/triple power supply redundancy |
| Protection Mechanisms | Overvoltage, overcurrent, short circuit, over temperature, lightning protection | Overvoltage, overcurrent, reverse polarity protection | Overvoltage, overcurrent, reverse polarity, surge protection |
| Power Efficiency | ≥90%, compliant with energy efficiency standards | ≥92% | ≥90% |
6.1.3 Environmental Parameters
| Parameter | Commercial Grade Models | Industrial Grade Models | Outdoor Models |
|---|---|---|---|
| Operating Temperature | 0℃ ~ 45℃ | -40℃ ~ 85℃ | -40℃ ~ 70℃ |
| Storage Temperature | -10℃ ~ 70℃ | -40℃ ~ 85℃ | -40℃ ~ 85℃ |
| Operating Humidity | 10% ~ 90% non-condensing | 5% ~ 95% non-condensing | 5% ~ 95% non-condensing |
| Protection Rating | IP20 | IP40 | IP65/IP67 |
| Cooling Method | Intelligent fan cooling | Fanless natural heat dissipation | Natural heat dissipation + thermal conductive structure |
| Immunity Level | EMC commercial grade | EMC industrial grade 4 | EMC industrial grade 4 + 6KV lightning protection |
| MTBF | ≥100,000 hours | ≥300,000 hours | ≥200,000 hours |
6.2 Performance Technical Specifications
6.2.1 Gigabit Access Series Fiber Optic Switch (Representative Model: LA-S324F-4S)
- Port Configuration: 24 Gigabit SFP optical ports + 4 10-Gigabit SFP+ uplink optical ports
- Switching Capacity: 128Gbps
- Packet Forwarding Rate: 96Mpps
- MAC Address Table: 16K
- VLAN Count: 4K, supports 802.1Q
- Buffer Capacity: 4MB shared buffer
- Forwarding Mode: Store-and-forward, wire-speed non-blocking
- Jumbo Frame Support: 9K bytes
- Port Aggregation: Up to 8 groups, maximum 8 ports per group
- Spanning Tree: STP/RSTP/MSTP
- Routing Table: 2K (Layer 3 models)
- Protocol Support: Static routing, RIP/OSPF (Layer 3 models)
6.2.2 10-Gigabit Aggregation Series Fiber Optic Switch (Representative Model: LA-S624X-8Q)
- Port Configuration: 24 10-Gigabit SFP+ optical ports + 8 40G QSFP+ optical ports
- Switching Capacity: 800Gbps
- Packet Forwarding Rate: 595Mpps
- MAC Address Table: 64K
- VLAN Count: 4K, supports flexible QinQ
- Buffer Capacity: 32MB shared buffer
- Routing Table: 16K
- Protocol Support: Static routing, RIP, OSPF, BGP, VRRP
- Features: VXLAN, ECMP equal-cost multi-path routing
- Stacking: Up to 8 units in a virtual stack
- Telemetry: Supported
6.2.3 Industrial Gigabit Fiber Optic Switch (Representative Model: LA-IS16F-2GS)
- Port Configuration: 16 Fast/Gigabit SFP optical ports + 2 Gigabit SFP uplink optical ports
- Switching Capacity: 36Gbps
- Packet Forwarding Rate: 26.8Mpps
- MAC Address Table: 8K
- VLAN Count: 4K
- Operating Temperature: -40℃ ~ 85℃
- Power Input: DC 12-57V dual power supply redundancy
- Industrial Ring Network: Supports ERPS, self-healing time <50ms
- Protocol Transparency: Supports Modbus TCP protocol pass-through
- Vibration Resistance: 5-500Hz, 20g acceleration
- Protection Rating: IP40
6.2.4 32G FC Storage Fiber Optic Switch (Representative Model: LA-FC24-32G)
- Port Configuration: 24 32Gbps FC ports, activated as needed
- Switching Capacity: 1.536Tbps
- Forwarding Latency: <2μs
- Maximum Cascade Hops: 7 hops
- FC Protocol Support: FC-FC, FCP, NVMe over FC
- Zone Count: 1024 Zones
- Protocol Support: NPIV, FDMI, FSPF routing
- Port Rate Auto-Negotiation: 32G/16G/8Gbps
- Power Supply: Dual redundant hot-swappable
- MTBF: >2,000,000 hours
6.3 Optical Interface Parameters
6.3.1 Optical Module Interface Standards
| Module Type | Rate | Interface Standard | Typical Application |
|---|---|---|---|
| SFP | 155Mbps / 1.25Gbps | IEEE 802.3u/z | Fast Ethernet / Gigabit access |
| SFP+ | 10Gbps | IEEE 802.3ae | 10-Gigabit access and aggregation |
| SFP28 | 25Gbps | IEEE 802.3by | 25G server access |
| QSFP+ | 40Gbps | IEEE 802.3ba | 40G backbone interconnection |
| QSFP28 | 100Gbps | IEEE 802.3bm | 100G core backbone |
| QSFP-DD | 400Gbps | IEEE 802.3bs | 400G ultra-high-speed core |
6.3.2 Typical Optical Module Optical Parameters
Gigabit Single-Mode SFP Optical Module (10km)
- Wavelength: 1310nm
- Transmit Optical Power: -9.5 ~ -3dBm
- Receive Sensitivity: ≤-20dBm
- Receiver Overload: 0dBm
- Transmission Distance: 10km (OS2 single-mode fiber)
- Connector Type: LC duplex
- Fiber Type: 9/125μm single-mode fiber
10-Gigabit Multi-Mode SFP+ Optical Module (300m)
- Wavelength: 850nm
- Transmit Optical Power: -7.3 ~ -1dBm
- Receive Sensitivity: ≤-11.1dBm
- Receiver Overload: 0.5dBm
- Transmission Distance: 300m (OM3 multi-mode fiber)
- Connector Type: LC duplex
- Fiber Type: 50/125μm OM3 multi-mode fiber
10-Gigabit Single-Mode SFP+ Optical Module (20km)
- Wavelength: 1310nm
- Transmit Optical Power: -8.2 ~ 0.5dBm
- Receive Sensitivity: ≤-14.4dBm
- Receiver Overload: 0.5dBm
- Transmission Distance: 20km (OS2 single-mode fiber)
- Connector Type: LC duplex
6.4 Software Function Specifications
6.4.1 Layer 2 Functions
- MAC Address: Automatic learning, automatic aging, supports static MAC configuration, port security
- VLAN: Supports 4K VLANs, 802.1Q tagging, Access/Trunk/Hybrid ports, VLAN stacking (QinQ), VLAN mapping
- Spanning Tree: STP (802.1d), RSTP (802.1w), MSTP (802.1s), root protection, loop protection
- Link Aggregation: Static aggregation, LACP (802.3ad), cross-device aggregation, load sharing
- Port Mirroring: Local mirroring, remote mirroring, flow mirroring
- Storm Suppression: Broadcast, multicast, unknown unicast storm suppression, bandwidth percentage-based control
- Port Features: Port rate forcing/auto-negotiation, flow control (802.3x), jumbo frame support, port isolation
6.4.2 Layer 3 Functions (Supported on Layer 3 Models)
- IP Routing: Static routing, default routing, RIP v1/v2, OSPF v2/v3, BGP4+
- Layer 3 Interfaces: VLANIF interfaces, Loopback interfaces, sub-interfaces
- Redundancy Backup: VRRP virtual router redundancy, ECMP equal-cost multi-path routing
- Multicast: IGMP Snooping, IGMP proxy, PIM-SM/SSM multicast routing
6.4.3 Security Functions
- Authentication: 802.1x port authentication, MAC authentication, Portal authentication
- Access Control: Standard/extended ACL, time-based ACL, VLAN ACL
- Security Protection: ARP spoofing protection, DHCP Snooping, IP source guard, DoS attack prevention, CPU protection
- Management Security: SSH/Telnet login restriction, username/password hierarchical management, operation log auditing
6.4.4 Management and Operations
- Management Methods: Console CLI, Telnet, SSH, Web graphical management, SNMP v1/v2c/v3
- Configuration Management: Configuration file backup/restore, factory configuration restore, batch configuration import/export
- Monitoring and Maintenance: Port status monitoring, optical module digital diagnostics (DDM), traffic statistics, system logs, alarm reporting
- System Upgrade: Web upgrade, CLI upgrade, USB upgrade, online seamless upgrade
- Intelligent Operations: Telemetry, fault alarms, performance statistics, automated inspection
Chapter 7 Product Functions and Features
7.1 Core Basic Functions
7.1.1 Wire-Speed Non-Blocking Forwarding
The KITOZER full series of fiber optic switches employs a non-blocking switching architecture. All ports can simultaneously operate at full rate in full-duplex mode without port bandwidth contention, ensuring that every link achieves maximum transmission performance. Combined with large-capacity shared buffering, the switches can handle burst traffic scenarios, prevent packet loss, and ensure smooth operation of high-bandwidth services such as video and storage.
7.1.2 Flexible Optical/Electrical Access
Supports standard pluggable optical module interfaces including SFP/SFP+/QSFP+. Users can flexibly select the appropriate optical modules based on transmission distance and fiber type. The switches are compatible with the full range of optical modules including single-mode, multi-mode, and various distances. Some models feature combo (optical/electrical multiplexed) ports, where the same port can be configured for either fiber or copper connectivity based on requirements, providing flexible networking options adaptable to diverse cabling environments.
7.1.3 Complete Layer 2 Switching Capability
Supports standard Ethernet protocols with complete Layer 2 functions including automatic MAC address learning, VLAN partitioning, Spanning Tree, and link aggregation, enabling the construction of flexible and reliable Layer 2 networks. VLAN partitioning achieves service isolation, Spanning Tree provides link redundancy, and link aggregation enhances bandwidth and reliability, meeting the fundamental networking requirements of various enterprise networks.
7.1.4 Layer 3 Routing and Forwarding (Layer 3 Models)
Layer 3 fiber optic switches feature high-performance Layer 3 routing capability, supporting static routing and multiple dynamic routing protocols. They can perform data forwarding across VLANs and subnets, serving as core routing nodes for small and medium-sized networks as a replacement for traditional routers, with significantly higher forwarding performance and better cost-effectiveness. VRRP virtual router redundancy provides core node backup, preventing single points of failure that could cause network-wide outages.
7.2 High Reliability Design Features
7.2.1 Full Hardware Redundancy Design
Mid-to-high-end models feature redundant power supplies and redundant fans with hot-swap support. A single component failure does not affect normal device operation, enabling online maintenance with zero business interruption. The core switching chip and CPU use independent power and cooling designs, and key components are derated for use to enhance overall device reliability.
Industrial-grade models feature dual or even triple power supply redundancy, supporting hybrid AC/DC power input to address unstable power supply conditions in industrial environments. The fanless design eliminates the fan failure point, further improving MTBF.
7.2.2 Link and Network Redundancy
Supports STP/RSTP/MSTP Spanning Tree protocols for building ring networks with link backup. RSTP convergence time is less than 1 second, and MSTP supports multiple instances for load sharing. Link aggregation technology bundles multiple links as mutual backups, with seamless traffic switching when a single link fails.
Industrial models support the ERPS Ethernet Ring Protection Switching protocol, with ring network fault self-healing time of less than 50ms, meeting the high real-time requirements of industrial control applications.
7.2.3 Comprehensive Protection Mechanisms
Power supplies feature multiple layers of protection including overvoltage, overcurrent, short circuit, over temperature, and lightning surge protection, preventing power anomalies from damaging the equipment. Ports feature ESD and lightning protection, with industrial models offering port lightning protection up to 6KV, suitable for outdoor and harsh electromagnetic environments.
The system incorporates a watchdog mechanism that automatically restarts the system upon software anomalies. Dual firmware images are supported, and failed upgrades automatically roll back to prevent upgrade failures from rendering the device unbootable.
7.3 Security Protection Features
7.3.1 Access Security Control
Supports multiple access authentication methods including 802.1x port authentication, MAC address authentication, and Portal authentication. Only authorized devices can access the network, preventing unauthorized terminal access. Port security functions can limit the number of MAC addresses learned on a port, preventing MAC flooding attacks.
Supports DHCP Snooping to block rogue DHCP servers and prevent terminals from obtaining incorrect IP addresses. Combined with IP Source Guard and ARP detection functions, it guards against common network attacks such as ARP spoofing and IP impersonation.
7.3.2 Access Control and Attack Protection
Supports flexible ACL (Access Control List) filtering based on MAC addresses, IP addresses, port numbers, protocol types, and other dimensions, enabling granular traffic control. DoS/DDoS attack prevention functions identify and mitigate common network attacks, protecting CPU and system resources from being exhausted by malicious traffic and ensuring normal business operation.
7.3.3 Management Security Assurance
Supports hierarchical user privilege management, assigning different operation permissions to different administrators to prevent misoperations and unauthorized operations. Supports SSH encrypted login and Web HTTPS management to prevent management data from being transmitted in plaintext and leaked. Operation log auditing records all administrator actions for traceability and fault diagnosis.
7.4 Easy Operations and Maintenance Features
7.4.1 Multiple Management Interfaces
Provides multiple management methods including Console local CLI, Web graphical interface, Telnet/SSH remote CLI, and SNMP network management, accommodating both professional operations personnel and non-professional users. The Web interface features a Chinese graphical design with clear and intuitive menus, allowing most configuration operations to be completed without memorizing commands, lowering the operational barrier.
7.4.2 Optical Module Intelligent Diagnostics
Supports optical module DDM (Digital Diagnostic Monitoring) functionality, enabling real-time reading of optical module parameters including transmit optical power, receive optical power, temperature, voltage, and bias current. Operations personnel can directly view link optical power status through the management interface, predict link faults without additional instruments, quickly locate optical link issues, and improve operations efficiency.
7.4.3 Comprehensive Fault Diagnosis Tools
Built-in diagnostic tools include port loopback detection, cable diagnostics, optical power monitoring, traffic statistics, and Ping/Traceroute, enabling rapid identification of link connectivity issues, cable faults, configuration errors, and other problems. Port mirroring functionality allows designated port traffic to be mirrored to a monitoring port for packet analysis with capture tools.
7.4.4 Batch Operations and Automation
Supports the SNMP protocol for integration with the KITOZER intelligent network management platform or third-party NMS systems, enabling centralized monitoring, configuration deployment, and alarm management for batch devices. Supports REST API and NETCONF interfaces for integration with automated operations platforms and SDN controllers, enabling network automation orchestration and management, adapted to the automated operations requirements of cloud computing and data centers.
7.5 Industrial-Grade Product Exclusive Features
7.5.1 Wide Temperature Fanless Design
Utilizes industrial-grade components with a fanless cooling design. Operating temperature range covers -40℃ to 85℃, enabling stable operation in both severe northern cold and southern outdoor high-temperature environments. The fanless design eliminates dust ingestion and noise issues associated with rotating fans, making it suitable for dusty industrial scenarios and environments requiring silent operation.
7.5.2 Strong Anti-Interference Capability
Passes EMC industrial grade 4 certification with strong electromagnetic interference immunity, ESD resistance, and surge resistance. Stable operation is ensured in strong electromagnetic environments such as substations, factory workshops, and rail transit systems, without data packet loss or device restarts caused by electromagnetic interference.
7.5.3 Industrial Protocol Compatibility
Supports transparent transmission of industrial Ethernet protocols including Modbus TCP and Profinet, enabling direct integration into industrial automation control systems for long-distance fiber interconnection of PLCs, sensors, industrial PCs, and other devices. Supports industrial ring network protocols for building fiber ring networks to achieve highly reliable industrial communications.
Chapter 8 Product Application Scenarios
8.1 Data Center and Cloud Computing Scenarios
8.1.1 Scenario Overview
Data centers represent one of the most critical application scenarios for fiber optic switches. Cloud computing, big data, and AI training services impose extremely high requirements on network bandwidth, latency, and reliability. Fiber optic switches serve as the core carrier of data center networks. The KITOZER data center series fiber optic switches can build Spine-Leaf architecture networks, meeting requirements for high-density server access, storage interconnection, and backbone transmission.
8.1.2 Deployment Solution
- Access Layer (Leaf Nodes): Utilizes 25G/100G fiber optic switches. Each server connects to a Leaf switch via a 25G fiber link, meeting high-bandwidth server access requirements and supporting virtualization and container cloud services.
- Core Layer (Spine Nodes): Utilizes high-end 100G/400G fiber optic switches. All Leaf switches are fully interconnected to Spine nodes, building a non-blocking CLOS architecture that ensures high-bandwidth forwarding between any two points.
- Storage Network: Utilizes 32G/64G FC fiber optic switches to build a dedicated SAN storage network. Servers connect to FC switches via HBA cards, connecting to all-flash arrays, tape libraries, and other storage devices, ensuring low-latency and highly reliable storage operations.
8.1.3 Solution Value
- High Bandwidth: Single-port 25G/100G rates meet ultra-high bandwidth requirements of AI training, distributed storage, and other applications.
- Low Latency: Cut-through forwarding and optimized switching chips keep forwarding latency at the sub-microsecond level, suitable for high-frequency trading and real-time computing scenarios.
- High Reliability: Full redundant architecture design with multiple levels of device, link, and node redundancy, ensuring 7×24 uninterrupted business operation.
- Easy Operations: Supports Telemetry and intelligent operations, enabling network visualization and rapid fault location.
8.2 Enterprise Office and Smart Campus Scenarios
8.2.1 Scenario Overview
Scenarios including enterprise office buildings, industrial parks, campuses, and hospitals feature wide network coverage and large numbers of terminals, including office computers, wireless APs, surveillance cameras, access control devices, and other endpoints. Long-distance fiber cabling is required for inter-building interconnection, making fiber optic switches the core devices for campus backbone and building access.
8.2.2 Deployment Solution
- Core Layer: Utilizes 10-Gigabit Layer 3 fiber optic switches as the campus core, providing interconnection between building aggregation nodes, handling routing and core gateway functions, and supporting VRRP redundancy backup.
- Aggregation Layer: Each building deploys one Gigabit aggregation fiber optic switch, connected via 10-Gigabit fiber uplinks to the core layer, aggregating the access switches within the building.
- Access Layer: Floor wiring closets deploy Gigabit fiber optic switches or optical/electrical hybrid switches with fiber uplinks to the aggregation layer and downlinks to terminal devices. For remote terminal locations, direct fiber connections to fiber optic switches overcome the 100-meter copper cable distance limitation.
8.2.3 Solution Value
- Long-Distance Transmission: Single-mode fiber enables inter-building interconnection over distances from several to tens of kilometers without repeater equipment.
- Service Isolation: VLAN partitioning isolates office services, surveillance services, and IoT services, ensuring data security.
- High Cost-Effectiveness: Tiered bandwidth design with Gigabit access + 10-Gigabit uplink balances performance and cost, meeting enterprise bandwidth requirements.
- Unified Management: All network switches can be centrally managed through the network management platform, reducing campus operations complexity.
8.3 Security Surveillance and Smart City Scenarios
8.3.1 Scenario Overview
Security scenarios including Safe City, smart transportation, campus surveillance, and forest fire prevention feature widely distributed and remote surveillance points. HD cameras, 4K cameras, and AI intelligent analysis devices have high bandwidth requirements, and many are deployed in harsh outdoor environments. Fiber optic switches serve as the core equipment for video transmission networks.
8.3.2 Deployment Solution
- Front-End Access: Outdoor locations deploy outdoor-grade or industrial-grade fiber optic switches to aggregate multiple HD cameras locally, transmitting video over long distances via fiber to the surveillance center. For dispersed point scenarios, ring network topology is adopted, where a single fiber link serially connects multiple nodes, saving fiber resources while providing link redundancy.
- Aggregation and Core: The surveillance center deploys high-capacity Gigabit/10-Gigabit fiber optic switches to aggregate all front-end video streams, connecting video storage devices, decoding/display control equipment, and platform servers, enabling video data switching and storage.
8.3.3 Solution Value
- Long-Distance Transmission: A single fiber can transmit over tens of kilometers, solving cabling challenges for remote points and cross-regional surveillance.
- High Bandwidth: Gigabit to the front-end and 10-Gigabit backbone meets the bandwidth requirements of 4K HD and multiple simultaneous video streams, ensuring smooth, stutter-free video.
- Interference Immunity: Fiber transmission is immune to electromagnetic interference, providing stable, snow-free video transmission in strong interference environments such as substations and near high-voltage lines.
- High Reliability: Industrial-grade wide-temperature design adapts to outdoor high and low temperature environments; ring protection enables rapid fault self-healing, where a single point failure does not affect the entire network.
8.4 Industrial Automation and Intelligent Manufacturing Scenarios
8.4.1 Scenario Overview
Industrial scenarios including factory workshops, intelligent production lines, power substations, mines, and rail transit feature harsh environments with high temperatures, dust, and strong electromagnetic interference. Industrial control services have extremely high requirements for real-time performance and reliability. Industrial-grade fiber optic switches are the foundational network equipment for the Industrial Internet.
8.4.2 Deployment Solution
- Production Line/Equipment Access: Deploys DIN-rail industrial fiber optic switches in production line control cabinets and equipment enclosures, connecting PLCs, sensors, servo drives, industrial cameras, and other devices, transmitting data via fiber to the workshop control room.
- Workshop Aggregation: Each workshop deploys an industrial-grade aggregation fiber optic switch to aggregate production line access nodes, connecting via fiber ring network uplinks to the factory core equipment room.
- Factory Core: The core equipment room deploys industrial core switches or commercial core switches for aggregation and forwarding of all factory industrial data, interfacing with MES, SCADA, and other industrial systems.
8.4.3 Solution Value
- Environmental Adaptability: Wide temperature range, dust resistance, vibration resistance, and electromagnetic interference immunity, adapted to harsh industrial environments.
- High Real-Time Performance: Low-latency forwarding + 50ms ring self-healing ensures real-time transmission of industrial control commands without affecting production operations.
- Flexible Power Supply: Wide-voltage DC input is compatible with industrial 24V/48V power systems; dual power supply redundancy ensures power reliability.
- Protocol Compatibility: Supports transparent transmission of various industrial bus protocols without additional conversion equipment, reducing deployment costs.
8.5 Power & Energy and Transportation Scenarios
8.5.1 Power System Applications
Power scenarios including substations, distribution stations, photovoltaic power plants, and wind farms feature complex electromagnetic environments, widely distributed equipment, and extremely high communication reliability requirements. KITOZER industrial-grade fiber optic switches comply with the IEC 61850-3 power standard and can build dedicated power communication networks for fiber transmission of services including relay protection, remote measurement and signaling (telemetry/telecontrol), and video surveillance.
Solution Features: Supports power industry protocols, strong electromagnetic compatibility, dual power supply redundancy, wide temperature operation, meeting the high reliability requirements of the power system’s “four remote” (remote signaling, remote measurement, remote control, remote adjustment) services.
8.5.2 Rail Transit Applications
Scenarios including subways, light rail, highways, and tunnels feature long stretches of trackside equipment, significant vibration, and wide temperature variations. Fiber optic switches can build fiber ring networks along the route, connecting signal equipment, surveillance equipment, broadcast equipment, and toll collection systems, enabling long-distance trackside communications.
Solution Features: Supports DIN-rail mounting, vibration resistance, wide temperature range, and rapid ring self-healing, meeting the long-distance and high-reliability communication requirements along transportation routes.
8.6 Broadcasting and Video Transmission Scenarios
Scenarios including television stations, broadcasting transmission networks, and live streaming base stations impose extremely high requirements on bandwidth, stability, and real-time performance for video signal transmission. Fiber optic switches combined with fiber transmission enable uncompressed, low-latency HD/UHD video signal transmission, widely applied in studios, broadcasting trunk transmission, and outdoor live streaming scenarios.
Solution Features: High bandwidth, low latency, interference immunity, and long transmission distances ensure high-quality, lossless video signal transmission.
Chapter 9 Product Installation
9.1 Pre-Installation Preparation
9.1.1 Environment Inspection
Before installation, the installation site environment must be inspected to ensure it meets equipment operating requirements and to prevent environmental factors from causing equipment failure:
- Temperature and Humidity Check: Confirm that the installation environment temperature and humidity are within the equipment’s allowable range. Commercial models: 0-45℃; Industrial models: -40-85℃; humidity non-condensing. Avoid installation in direct sunlight, near heat sources, or in damp, condensation-prone locations.
- Space and Ventilation Check: Sufficient ventilation space must be reserved around the equipment. Rack-mounted equipment requires at least 10cm of ventilation clearance at the front and rear to ensure proper airflow. The cabinet must have adequate ventilation and heat dissipation conditions, avoiding heat buildup in sealed cabinets.
- Cleanliness Check: Avoid installation in areas with severe dust, oil fumes, or corrosive gases. Excessive dust will block ventilation openings, accelerate component aging, and may even cause short circuits. Although industrial-grade models have some dust resistance, harsh dusty environments should still be avoided.
- Electromagnetic Environment Check: Maintain distance from strong electromagnetic interference sources such as high-power motors, transformers, and high-frequency equipment. Although fiber itself is interference-immune, the device control circuits may still be affected by strong electromagnetic fields, so a reasonable distance must be maintained.
- Installation Foundation Check: For rack mounting, confirm the cabinet meets 19-inch standards, that the mounting post spacing and screw hole positions match, and that the cabinet load capacity supports the equipment weight. For desktop placement, confirm the surface is flat, stable, and free from severe vibration. For wall/DIN-rail mounting, confirm the mounting surface is secure and can bear the equipment weight.
9.1.2 Unpacking and Inspection
After the equipment arrives on site, unpacking and inspection must be performed before installation. The steps are as follows:
1. Check the packaging box exterior for damage, impact marks, or water stains. If any anomalies are found, photograph them for documentation and contact the logistics provider and supplier.
2. After opening the box, remove the equipment and accessories, and check each item against the product list in Chapter 4 to verify quantities and models, confirming they match the purchase order.
3. Inspect the equipment exterior for deformation, paint chips, loose screws, port damage, and verify that the optical port dust caps are intact.
4. Verify that the equipment serial number and factory label are complete, and check the warranty card information.
5. After inspection is confirmed correct, properly store the packaging box and cushioning materials for future equipment return for repair or transport.
9.1.3 Electrostatic Discharge (ESD) Protection Preparation
Fiber optic switches contain numerous CMOS electrostatic-sensitive devices. Electrostatic discharge can cause permanent chip damage. Therefore, ESD protection must be performed before installation operations:
- Operators must wear an anti-static wrist strap, with the other end reliably grounded (e.g., cabinet grounding bar, anti-static grounding station), ensuring good skin contact with the wrist strap.
- When an anti-static wrist strap is not available, touch a grounded metal object first to discharge body static before touching internal device components.
- Optical modules, motherboards, and other precision components must not be touched directly on circuit boards or gold fingers. Handle by the housing edges only.
- Do not operate equipment in environments prone to static generation, such as on carpets or synthetic fiber surfaces.
9.2 Rack-Mounted Installation
Rack-mounted installation is the most common installation method in equipment rooms. The equipment is secured in a standard 19-inch cabinet, providing a clean, organized appearance and facilitating unified management.
9.2.1 Installation Steps
Install Mounting Brackets
Align the mounting brackets on both sides of the equipment with the screw holes on the chassis sides and fasten them securely with the provided screws. The brackets have two mounting positions (front and rear), adjustable to match the cabinet depth, ensuring the equipment front panel is flush with the cabinet mounting posts after installation.
Mount the Equipment
Two people should coordinate to lift the equipment, align it with the cabinet mounting position, and smoothly place it onto the cabinet shelf or rails. If the cabinet has rails, install the rails on the cabinet posts first, then slide the equipment into the cabinet along the rails.
Secure the Equipment
Adjust the front-back position of the equipment to ensure the bracket screw holes align with the cabinet post holes. Use cabinet screws to secure the left and right brackets to the cabinet posts. Tighten screws with moderate force to avoid stripping threads.
Ground Connection
Connect the equipment grounding terminal to the cabinet grounding copper bar using dedicated grounding wire. The grounding wire cross-section should not be less than 1.5mm². Ensure reliable grounding to maintain the equipment’s lightning protection and ESD performance.
9.2.2 Installation Precautions
- The equipment installation position should avoid cabinet air outlets and direct air conditioning airflow to prevent condensation from entering the equipment.
- At least 1U of heat dissipation space should be reserved above and below the equipment. Stacking multiple devices without gaps is prohibited.
- Heavy equipment should be installed in the lower-middle portion of the cabinet to lower the center of gravity and prevent tipping.
- Avoid scraping the equipment front panel and ports with hard objects during installation to prevent interface damage.
- After installation is complete, ensure the cabinet is stable and does not wobble.
9.3 Desktop Installation
Desktop installation is suitable for scenarios without standard cabinets, such as small offices and weak current boxes, offering simple and flexible installation.
1. Attach the non-slip rubber feet to the four corner positioning points on the bottom of the chassis, ensuring they are firmly adhered.
2. Place the equipment level and stable on a flat, sturdy desktop or surface, avoiding overhanging edges.
3. Reserve sufficient ventilation space around the equipment. Do not place other items on top of the equipment, as this may block ventilation openings.
4. The equipment placement location should be away from water sources, heat sources, and direct sunlight.
5. For wall-mount installation, use the included wall-mount bracket. First secure the bracket to the wall, then attach the equipment to the bracket and tighten the screws, ensuring secure installation.
9.4 Industrial DIN-Rail Installation
Industrial-grade fiber optic switches typically use DIN-rail mounting, compatible with the standard mounting rails inside industrial control cabinets.
1. Confirm that a standard 35mm DIN rail is installed in the control cabinet and that the rail is securely fastened.
2. Hook the upper edge of the rail clip on the back of the equipment onto the top edge of the DIN rail, then press the equipment downward. A “click” sound indicates the clip is locked and the equipment is secured to the rail.
3. Gently shake the equipment to confirm it is securely mounted and will not come loose.
4. For removal, use a screwdriver to push down the clip release lever at the bottom of the equipment while lifting the equipment upward to detach it from the rail.
9.4.1 Industrial Installation Precautions
- The equipment should be installed with ports facing downward or horizontally. Ports facing upward are prohibited to prevent dust and condensation water from entering the interfaces.
- The control cabinet should maintain good ventilation to prevent excessive temperatures in sealed spaces.
- The equipment should be installed in a ventilated position in the middle of the control cabinet, away from heat-generating equipment such as variable frequency drives and servo drives.
- When multiple devices are installed side by side, maintain a gap of at least 20mm between devices for heat dissipation.
9.5 Power Supply Installation and Grounding
9.5.1 AC Power Connection
1. Confirm that the equipment power switch is in the OFF position.
2. Insert one end of the power cord into the equipment power connector and tighten the retaining clip (for power connectors with locking mechanisms).
3. Connect the other end of the power cord to a reliable mains outlet or cabinet PDU outlet. The outlet must have a grounding pin.
4. For redundant power supply models, connect two separate independent power circuits to prevent equipment shutdown from a single circuit failure.
5. When routing power cables, avoid bundling them together with fiber optic cables or network cables. Route them separately with a spacing greater than 10cm to reduce electromagnetic interference.
9.5.2 DC Power Connection
Industrial DC models — connection steps:
1. Confirm that the external DC power supply is turned off to avoid live connection.
2. Strip approximately 5mm of insulation from the end of the DC power wire and insert it into the corresponding terminal on the equipment power terminal block.
3. Ensure correct polarity: typically V+ connects to positive, V- connects to negative, and GND connects to protective ground. After connection, gently pull to confirm the wire is secure and not loose.
4. For dual power supply models, connect two independent DC power sources separately for power redundancy.
5. Turn on the external power switch and check that the equipment power indicator lights up normally.
9.5.3 Grounding Specifications
Proper grounding is an important guarantee for the equipment’s lightning protection, ESD protection, and interference immunity. The grounding specifications must be strictly followed:
- The equipment must be reliably grounded. Ground resistance should be less than 4Ω. The equipment room grounding system must comply with national telecommunications equipment room grounding standards.
- The grounding wire should use yellow-green dual-color dedicated grounding wire with a cross-section of not less than 1.5mm², and the length should be as short as possible to reduce grounding impedance.
- The grounding wire must not be connected to non-dedicated grounding bodies such as water pipes or heating pipes, and must not be mixed with power ground wires.
- Cabinet grounding, equipment grounding, and shield layer grounding must be connected to the same grounding system to avoid potential differences.
10.1 Preparation and Specifications Before Wiring
10.1.1 General Wiring Principles
- Clear Labeling: Labels must be attached to both ends of all cables, indicating the number, location of both ends, and purpose, to facilitate subsequent maintenance and troubleshooting.
- Categorized Routing: Power cables, optical fibers, and network cables should be routed in separate categories to avoid mixed bundling. Strong and weak currents must be separated with a spacing of ≥10cm. Crossings should be as perpendicular as possible.
- Bending Radius: The bending radius of optical fibers must be ≥20 times the fiber diameter. Static bending should be ≥30mm, dynamic bending ≥50mm. Excessive bending that may cause fiber breakage is strictly prohibited.
- Bundling Specifications: Use nylon cable ties or dedicated fiber optic binding straps for bundling. Tightness should be appropriate; over-tightening that compresses the fiber core is prohibited.
- Cleanliness Requirements: Optical interfaces and fiber end faces must be kept clean. Dust prevention measures must be taken before operation to avoid dust contamination.
10.1.2 Optical Fiber and Optical Module Inspection
Before wiring, the optical modules and fiber patch cords must be inspected to ensure they are intact and usable:
- Optical Module Inspection: Check that the optical module housing has no damage, the gold fingers have no oxidation or scratches, and the model, rate, wavelength, and transmission distance meet design requirements.
- Fiber Patch Cord Inspection: Check that the fiber patch cord jacket has no damage or bend marks, the connector end face has no scratches or stains, and the fiber type (single-mode/multi-mode) matches the optical module.
- Optical Link Testing: After long-distance optical link cabling is completed, use an optical power meter and OTDR to test link attenuation and splice loss, ensuring that the link loss is within the allowable range of the optical module.
10.2 Optical Module Installation
Optical modules are precision optical devices; installation operations must be standardized to avoid damage to the equipment and modules.
10.2.1 Installation Steps
1. Wear an anti-static wrist strap to discharge static electricity from the human body.
2. Remove the optical module from its packaging, holding the module housing. Touching the gold fingers and the ceramic end face of the optical port is strictly prohibited.
3. Confirm the orientation of the optical module. The gold fingers should face the switch port slot, and the pull ring should be in the unlocked state (pulled down position).
4. Align the optical module steadily with the port slot, push it in evenly and firmly until a “click” sound is heard, indicating that the module latch is locked and the module is fully seated.
5. After installation, gently pull the optical module outward to confirm it will not come out and is firmly secured.
6. Remove the dust plug from the optical port of the optical module, preparing to connect the fiber patch cord.
10.2.2 Optical Module Removal Steps
1. Confirm that the business on the corresponding port has been shut down to avoid affecting operation during insertion/removal.
2. Flip the pull ring of the optical module upward to release the latch, while pulling the module out evenly and firmly.
3. Forcibly pulling, shaking left and right, or yanking the module out is strictly prohibited to avoid damaging the port slot and the module’s gold fingers.
4. Promptly cover the removed optical module with its dust plug and store it in anti-static packaging.
10.2.3 Optical Module Installation Precautions
- The optical module must match the switch port type. Mixing modules of different specifications is prohibited. For example, SFP modules cannot be inserted into SFP+ slots (except for some compatible models).
- Optical modules support hot-swapping, but it is recommended to insert/remove them while the port is shut down to minimize impact on services.
- Avoid exposing the optical port of the optical module for extended periods. Keep the dust plug sealed when not connected to prevent dust contamination.
- Non-original optical modules may have compatibility issues. It is recommended to use KITOZER officially certified optical modules to ensure stability and after-sales support.
10.3 Fiber Patch Cord Connection
10.3.1 Connection Steps
1. Prepare fiber optic cleaning tools and clean the fiber end faces and optical module interfaces.
2. Remove the dust caps from both ends of the fiber patch cord. Place the dust caps in a clean location to avoid contamination.
3. Confirm the fiber transmit/receive direction: Duplex fiber has two directions: Transmit (TX) and Receive (RX). The local Transmit must connect to the remote Receive, and the local Receive must connect to the remote Transmit. Reversing them will result in link failure.
4. Align the fiber connector with the optical module interface, insert it steadily until a “click” sound indicates it is locked in place.
5. Connect the other end to the remote device’s optical module using the same method.
6. After connection, organize the fiber patch cords, leaving appropriate slack, and secure them with ties to avoid tension and strain.
10.3.2 Fiber End Face Cleaning Specifications
Contamination on the fiber end face is the most common cause of increased optical link attenuation and link failure. The end face must be cleaned before wiring:
- Cleaning Tools: Use dedicated fiber optic cleaning pens, lint-free wipes (with anhydrous ethanol), and compressed air cans.
- Cleaning Methods:
- Cleaning Pen: Insert the cleaning pen into the optical port or connector end face, press and rotate 1-2 times to remove dust from the end face.
- Lint-free Wipe: Fold the lint-free paper into a narrow strip, dip it in a small amount of anhydrous ethanol, and wipe the end face in one direction. Wiping back and forth repeatedly is strictly prohibited.
- Connect promptly after cleaning to avoid re-exposure to air and dust accumulation.
- Using hands, regular tissue, or clothing to wipe the fiber end face is strictly prohibited. Using cleaning agents other than alcohol is strictly prohibited.
10.3.3 Fiber Optic Cabling Specifications
In-Cabinet Cabling:
- Route optical fibers from the cable management brackets on both sides of the cabinet, avoiding crossing the front of the equipment.
- Reserve 30-50cm of slack before the fiber enters the equipment for future maintenance and insertion/removal.
- Maintain smooth arc transitions at fiber bends. Minimum bending radius should be ≥30mm. Right-angle bending is strictly prohibited.
- Use fiber optic cable managers and winding rings to organize excess fiber. Over-tightening is strictly prohibited.
Outdoor/Inter-Building Cabling:
- For outdoor cabling, use armored optical cables, routed through conduits or along cable trays, to avoid external crushing and rodent damage.
- Implement water-proof bends where the optical cable enters the equipment room to prevent rainwater from flowing along the cable into the room.
- Reliably ground the strength members of the optical cable to prevent lightning-induced currents from damaging equipment.
- Provide proper splice protection for long-distance links. Place splice points in the Optical Distribution Frame (ODF) and label them clearly.
Label Management:
- Attach labels to both ends of each fiber, indicating the local port, remote device and port, and link number.
- Mark correspondingly on both sides of the ODF adapter flanges for one-to-one correspondence.
- Ensure labels have clear, waterproof, and wear-resistant printing for long-term retention.
10.4 Management Port Wiring
10.4.1 Console Port Connection
The Console port is used for initial device configuration and fault maintenance. Connection method:
1. Locate the Console interface on the device panel (usually an RJ45 interface labeled CONSOLE).
2. Insert the RJ45 end of the configuration cable into the device’s Console port, and the other end into the computer’s serial port (COM port); if the computer lacks a serial port, use a USB-to-serial adapter and install the driver.
3. On the computer, open serial debugging software (such as SecureCRT, PuTTY, HyperTerminal). Set the serial port parameters as: Baud rate 9600, Data bits 8, Stop bits 1, Parity None, Flow control None.
4. After powering on the device, press the Enter key to access the command-line interface for configuration operations.
10.4.2 Management Network Port Connection
The management network port is used for remote Web management and network management. Connection method:
1. Locate the MGMT management network port (RJ45 interface) on the device panel.
2. Use a standard network cable to connect the management network port to the management network or a computer’s network port.
3. After configuring the management IP address, the device can be accessed remotely via a browser or Telnet/SSH.
4. It is recommended to connect the management network port to an independent management network, isolated from the service network, to enhance management security.
10.5 Post-Wiring Inspection
After all cables are connected, perform the following checks before powering on:
- Verify that all cable connections match the design drawings, with no incorrect or missed connections.
- Check that all connectors are fully seated and secure, and fiber connectors are not skewed.
- Check that power cables are firmly connected, grounding is reliable, and there is no risk of short circuit.
- Organize and secure cables with ties, ensuring equipment ventilation holes are not blocked and cables do not strain the device interfaces.
- Confirm that all fiber bending radii meet requirements, with no excessive bending.
- Clean up debris from the site, keeping the installation environment tidy.
11.1 Preparation Before Commissioning
11.1.1 Commissioning Tools and Documentation Preparation
The following tools and documentation should be prepared before commissioning:
- 1 laptop computer, with serial debugging software, browser, packet capture software, and other tools installed.
- Spare cables including Console configuration cable, network cables, fiber patch cords, etc.
- Design documentation including network design drawings, VLAN planning tables, IP address planning tables, port assignment tables, etc.
- Default username and password for device login, firmware upgrade package (if upgrade is needed).
- Testing tools: Optical power meter, visual fault locator (red light pen), Ping testing tool.
11.1.2 Power-On and Startup Check
After completing the wiring inspection, power on the device and check its basic status:
1. Turn on the device power switch and observe the status of the panel indicators.
2. The Power indicator (PWR) should be steady green, indicating normal power supply; if it is off, check the power cable and power supply.
3. The System Running indicator (SYS) should blink after power-on and blink normally after startup completes (typically once per second), indicating normal system operation; if it is steady on or off, the system startup may have failed.
4. The Port indicator (LINK/ACT) for connected fibers should be steady green for link connectivity, blinking for data transmission; if off, check the fiber connection and optical module status.
5. Fans should spin smoothly after startup with no abnormal noise; smart fans initially run at full speed and automatically reduce speed once the temperature stabilizes.
6. The device startup process takes approximately 1-3 minutes. After completion, the configuration interface is accessible.
11.2 Local Command Line Basic Configuration
Logging into the device via the Console port for initial basic configuration is the foundational step in device commissioning.
11.2.1 Logging into the Device
1. Open serial debugging software, set the correct serial port parameters, and connect to the device.
2. After device startup completes, press Enter to see the login prompt.
3. Enter the default username and password (factory default is typically admin/admin; refer to the product manual for specifics). After successful login, the user view is entered.
4. It is strongly recommended to change the default password immediately upon first login to enhance device security.
11.2.2 Basic System Configuration
Modifying Device Name
system-view sysname LA-Switch-Core
Set the device name according to the network plan to distinguish different devices.
Configuring Management IP Address
interface vlanif 1 ip address 192.168.1.1 255.255.255.0 quit
The management IP is used for remote management. It is recommended to create a dedicated management VLAN and configure the corresponding VLANIF interface IP.
Configuring Default Gateway
If cross-subnet device management is required, configure the default gateway:
ip route-static 0.0.0.0 0.0.0.0 192.168.1.254
Configuring Remote Management
Enable Telnet or SSH services and configure remote login users:
telnet server enable user-interface vty 0 4 authentication-mode aaa protocol inbound telnet ssh quit aaa local-user admin password cipher custom-password local-user admin service-type telnet ssh local-user admin privilege level 15 quit
After configuration, the device can be accessed remotely via a network cable without needing the Console cable.
11.2.3 VLAN Configuration
Create VLANs based on the network plan and configure port types:
Creating VLANs
vlan batch 10 20 30
Batch creates VLANs 10, 20, 30, corresponding to different services.
Configuring Access Ports (For terminal access)
interface gigabitethernet 0/0/1 port link-type access port default vlan 10 quit
Set port 1 as an Access port, belonging to VLAN 10, used for connecting terminal devices.
Configuring Trunk Ports (For switch cascading)
interface gigabitethernet 0/0/24 port link-type trunk port trunk allow-pass vlan 10 20 30 quit
Set port 24 as a Trunk port, allowing tagged VLANs 10, 20, 30 to pass through for inter-switch connectivity.
11.3 Web Graphical Interface Commissioning
For non-professional operation and maintenance personnel, the Web graphical interface is more intuitive and simpler. The Web commissioning process is as follows:
1. Connect a computer via network cable to the device’s management port or a regular port, and set the computer’s IP address to the same subnet as the device’s management IP.
2. Open a browser, enter the device’s management IP address, and navigate to the login page.
3. Enter the username and password to log in. The Web management homepage displays an overview of device running status, port status, CPU/memory usage, etc.
11.3.1 Port Configuration
In the Web interface, navigate to Port Management -> Port Configuration to view the status of all ports and configure parameters such as port speed, duplex mode, flow control, and port description.
- Speed/Duplex: Default is auto-negotiation. To force speed, options like forced Gigabit full-duplex can be selected. Note that configurations on both ends must be consistent.
- Port Description: Fill in the device and purpose connected to the port for easy O&M identification.
11.3.2 VLAN Configuration
Navigate to Layer 2 Switching -> VLAN Configuration to create VLANs, configure port VLAN attributes, graphically select ports to join corresponding VLANs, and set Access/Trunk modes. This requires no commands and is simple to operate.
11.3.3 Link Aggregation Configuration
Navigate to Layer 2 Switching -> Link Aggregation to create an aggregation group, add member ports, select static aggregation or LACP dynamic aggregation mode, and configure load balancing methods.
Link aggregation increases link bandwidth and reliability. Aggregated links are recommended for inter-switch connections.
11.3.4 System Maintenance
Navigate to System Management -> System Maintenance for operations such as configuration file backup/restore, firmware upgrade, device reboot, and factory reset.
- Configuration Backup: Regularly back up configuration files to prevent loss; always back up current configuration before upgrading firmware.
- Firmware Upgrade: Select the official firmware file, upload and execute the upgrade. Power interruption during upgrade is strictly prohibited, as it may damage the device.
11.4 Advanced Function Commissioning
11.4.1 Layer 3 Routing Commissioning
Layer 3 switches require routing functions for inter-subnet communication:
1. Configure IP addresses on VLANIF interfaces for each VLAN, serving as gateways for the respective subnets.
2. Configure dynamic routing protocols (e.g., OSPF), advertising the corresponding subnets to achieve route exchange with other Layer 3 devices; static routes can also be configured for smaller networks.
3. Configure VRRP virtual routing, forming a redundant gateway with another core switch to achieve gateway backup, enabling seamless gateway switching upon single device failure.
11.4.2 Security Function Commissioning
- Port Security: Enable the port security feature to limit the maximum number of MAC addresses on a port, preventing unauthorized access.
- ACL Access Control: Configure ACL rules to restrict access permissions for specific IPs and ports, achieving service isolation and security control.
- 802.1x Authentication: Integrate with a RADIUS server and enable 802.1x authentication on ports to achieve identity authentication for terminal access.
11.4.3 Optical Link Commissioning and Optimization
- Viewing Optical Module Parameters: View optical module DDM information via the command line or Web interface, reading transmit optical power and receive optical power values.
- Optical Power Assessment: Receive optical power should be between the sensitivity and overload point. Typically, for Gigabit single-mode, -3 to -20dBm is considered normal. If optical power is too low, check fiber end faces, link attenuation, and splice quality; if optical power is too high (e.g., mixing short-reach and long-reach modules), an optical attenuator needs to be added.
- Link Optimization: For links with high bit error rates, prioritize cleaning fiber end faces, checking fiber bending, and replacing faulty optical modules to ensure the link operates optimally.
11.5 Service Verification and Testing
After configuration, comprehensive service verification must be performed to ensure network functionality meets design requirements:
11.5.1 Connectivity Testing
- Ping between terminals within the same VLAN to verify Layer 2 connectivity; expect no packet loss and low latency.
- Ping between terminals in different VLANs to verify Layer 3 routing forwarding.
- Ping the gateway and external network addresses from terminals to verify routing and uplink connectivity.
- Perform extended Ping tests (e.g., 1000 packets) on long-distance fiber links; packet loss should be 0%, ensuring link stability.
11.5.2 Functional Verification
- VLAN Isolation Verification: Terminals in different VLANs should not be able to communicate at Layer 2 by default, verifying the VLAN isolation effect meets the design.
- Link Redundancy Test: Disconnect one link in the aggregation group; services should not be interrupted, and traffic automatically switches to remaining links, verifying the link aggregation redundancy function.
- Spanning Tree Test: Simulate a primary link failure; the backup link should automatically activate, restoring network connectivity, verifying the spanning tree function.
- Port Mirroring Test: Configure port mirroring and use packet capture software to verify the accuracy of mirrored traffic.
11.5.3 Performance Testing
- Use speed testing tools to test port throughput, verifying whether it reaches the nominal rate.
- Test device CPU and memory usage under high traffic; they should remain within a reasonable range without obvious lag.
- Monitor port error counters. CRC errors and frame errors should be 0; continuous growth indicates potential link or hardware issues.
11.6 FC Storage Switch Commissioning Points
FC fiber channel switch commissioning differs from Ethernet switches. The core commissioning tasks include:
- Device Initialization: Set the switch IP, name, time zone, and administrator password.
- Fabric Configuration: Configure the Domain ID, ensuring uniqueness within the same Fabric; cascade multiple switches to build a complete SAN network.
- Zoning Configuration: Create zones based on business planning, add server HBA cards and storage ports to corresponding zones, activate the configuration, ensuring only authorized devices can access storage.
- Status Verification: Check device login status, port rates, and link status. Verify that servers can properly recognize storage volumes and perform normal I/O read/write operations.
- Performance Monitoring: Monitor port bandwidth utilization, IOPS, and latency to ensure storage network performance meets business requirements.
12.1 Installation and Construction Precautions
- Equipment installation must be performed by qualified technical personnel. Non-professionals are strictly prohibited from disassembling or wiring the equipment to avoid electric shock and equipment damage.
- Relevant power sources must be disconnected before installation and construction. Live disassembly/assembly or wiring is strictly prohibited (except for hot-swappable components).
- Handle the equipment with care during transportation, avoiding severe vibration and impact. Stacking heavy objects on the equipment is strictly prohibited.
- When installing in a rack, ensure the equipment is securely fixed to prevent tipping; coordinate with multiple people for rack mounting to avoid injury to personnel and damage to equipment.
- When working with fiber optics, do not look directly into the laser emission port of optical modules. Laser light can damage eyes, especially when using optical instruments like microscopes.
- Outdoor cabling requires proper lightning protection and grounding. The metallic strength members and shielding layers of optical cables must be reliably grounded to prevent lightning damage.
- Clean up the site after construction. Leaving metal debris, wire scraps, or other objects inside equipment or cabinets is strictly prohibited to prevent short circuits.
12.2 Operational Usage Precautions
- During equipment operation, covering or blocking ventilation holes is strictly prohibited. Placing objects on top of the equipment is strictly prohibited; ensure proper heat dissipation.
- Keep the equipment room environment clean, dust regularly, and prevent dust from entering the equipment which can cause poor heat dissipation and reduced insulation.
- Maintain operating environment temperature and humidity within rated ranges. Strengthen air conditioning cooling in high-temperature seasons to prevent equipment overheating.
- Avoid arbitrarily plugging/unplugging operating optical modules and fiber patch cords. Confirm services have stopped or been switched before insertion/removal to avoid service interruption.
- Avoid arbitrarily modifying device configurations. Always back up the original configuration before making changes, and verify normal operations after configuration changes.
- Firmware upgrades must use official release versions. Power off and restart during the upgrade process are strictly prohibited. Verify functionality after the upgrade.
- Change management passwords regularly and implement hierarchical access permissions to avoid weak passwords and unauthorized operations.
12.3 Storage and Transportation Precautions
- Equipment should be stored in its original packaging in a dry, well-ventilated warehouse free from corrosive gases, avoiding humidity, high temperatures, and direct sunlight.
- Storage environment temperature: -10℃~70℃, humidity 5%~95% non-condensing. Check the environment periodically for long-term storage.
- Use shock-proof, moisture-proof, and drop-proof packaging during transportation. Avoid severe jostling and impacts. Inverting or placing heavy objects on top is strictly prohibited.
- Precision accessories such as optical modules and fiber patch cords should be individually packaged to avoid compression and collision. Protect fiber connectors with dust caps.
- Before first power-on after long-term storage, the equipment must be placed in a room temperature environment for more than 2 hours to allow the equipment to reach room temperature before powering on, preventing short circuits caused by condensation.
12.4 Safety and Compliance Precautions
- The equipment must be reliably grounded, with grounding resistance meeting national standards, to prevent electrostatic and lightning damage and ensure personal safety.
- The equipment power supply circuit must be equipped with appropriate circuit breakers and surge protectors to prevent damage from lightning and surges.
- Disassembling the equipment or modifying internal circuits without authorization is strictly prohibited. Doing so will void the warranty and may create safety hazards.
- When disposing of the equipment, follow electronic waste disposal regulations. Arbitrary disposal is strictly prohibited to protect the environment.
- The use of fiber optic communication equipment must comply with national communication management regulations. Use in classified environments must comply with confidentiality standards.
13.1 Routine Maintenance Specifications
Routine maintenance is key to ensuring long-term stable operation and extending the service life of the equipment. A periodic maintenance system should be established.
13.1.1 Daily Inspection
Operations and maintenance personnel should inspect the equipment daily, focusing on:
- Equipment indicator status, checking if power, system, and port indicators are normal and no alarm indicators are lit.
- Equipment operating sounds, checking if fans are running smoothly with no abnormal or unusual noise.
- Equipment surface temperature, checking for localized overheating and normal temperature at the cabinet outlet.
- Equipment room temperature and humidity, recording readings to ensure they are within the allowable range for the equipment.
- Optical link status, checking if port optical power is within the normal range and free from abnormal fluctuations.
- Record inspection results in the O&M log. Address any abnormalities promptly.
13.1.2 Monthly Maintenance
Perform comprehensive maintenance monthly, including:
- Cleaning and Dust Removal: Wipe dust from the equipment surface with a dry soft cloth; use a compressed air can to clean dust from equipment ventilation holes and fans; clean dust inside the cabinet as well.
- Cable Inspection: Check that all cable connections are secure, free from looseness, aging, or damage; check fiber patch cords for excessive bending or strain; verify labels are intact and legible.
- Status Check: Log into the management interface to check device CPU and memory usage, port traffic and error counts, optical module parameters, and system log alarms.
- Configuration Backup: Back up the device’s current configuration file and store it off-site to prevent configuration loss.
- Performance Statistics: Compile port bandwidth utilization and peak traffic statistics to assess network capacity and provide a basis for expansion.
13.1.3 Quarterly/Annual Deep Maintenance
Perform deep maintenance quarterly or annually:
- Power-off Dust Removal (when business permits): Clean dust from internal circuit boards, fans, and power supplies using anti-static brushes and compressed air.
- Check power supply and fan operating status, test redundant power module switching functionality, and verify fault switching is normal.
- Test link redundancy functions, verifying that redundancy mechanisms such as Spanning Tree, Link Aggregation, and VRRP work correctly.
- Conduct comprehensive fiber link testing, using OTDR to check the attenuation and splice status of entire links, and clean all fiber connectors.
- Evaluate firmware versions, upgrade to the latest stable version when necessary to fix known bugs and improve stability.
- Conduct a comprehensive security check, update passwords, audit user permissions, and verify the effectiveness of security policies.
13.2 Common Component Replacement
KITOZER fiber optic switches feature a modular design, supporting on-site replacement of wearing parts without requiring the whole unit to be returned to the factory.
13.2.1 Optical Module Replacement
Optical modules are consumable parts that can be replaced on-site in case of failure or upgrade:
1. Confirm that the business on the corresponding port has been stopped or switched to avoid affecting services.
2. Wear an anti-static wrist strap, disconnect the fiber patch cord, and cover it with its dust cap.
3. Flip up the optical module’s pull ring, smoothly pull out the faulty module, and place it in anti-static packaging.
4. Insert a new optical module of the same specification, confirm it locks into place, and reconnect the fiber patch cord.
5. Log into the device to check port status and optical power, confirming the link has returned to normal.
13.2.2 Power Module Replacement (Hot-swappable Models)
Redundant power supply models support online replacement of power modules without shutdown:
1. Confirm that the faulty power supply’s indicator is abnormal, the other power supply works normally, and the equipment is running normally.
2. Turn off the switch of the faulty power supply and unplug the power cord.
3. Press the latch on the power module and pull the faulty power module out smoothly.
4. Push the new power module in smoothly along the guide rails until the latch locks securely.
5. Plug in the power cord, turn on the power switch, observe the power indicator light up, and verify normal equipment operation.
6. Note: Avoid touching the internal circuits of the power supply during replacement to prevent electric shock.
13.2.3 Fan Module Replacement (Hot-swappable Models)
High-end models support hot-swappable fan replacement:
1. Confirm the fan failure, ensure other fans are running normally, and the equipment temperature is within the normal range.
2. Press the latch on the fan module and pull the faulty fan outwards.
3. Align the new fan module with the slot, insert it, and push it in until it clicks into place.
4. Observe the new fan start running, the equipment alarm clears, and the temperature returns to normal.
5. Perform the replacement as quickly as possible to avoid excessively high internal temperatures.
13.3 Troubleshooting and Repair Process
When equipment malfunctions, follow the process below:
1. Fault Recording: Record the fault symptom, occurrence time, operations before the fault, equipment indicator status, and alarm information in detail for fault localization.
2. Preliminary Troubleshooting: Refer to the troubleshooting methods in Chapter 14 for initial checks, determine the fault type, and attempt simple recovery operations such as restarting the device, cleaning fiber, or replacing optical modules.
3. Technical Support: If preliminary troubleshooting cannot resolve the issue, contact KITOZER technical support hotline +86 13538869979, providing information such as device model, serial number, and fault symptoms. Technical engineers will provide remote guidance.
4. Return for Repair: If the technical engineer confirms a hardware fault requiring factory repair, fill out the warranty card, package the device properly using original packaging, and ship it to the designated repair center.
5. Repair Acceptance: After the repaired device is returned, power it on and test its functionality. Confirm the fault is resolved before putting it back into service.
13.4 Warranty Policy Description
The entire KITOZER fiber optic switch product line offers a 36-month free warranty, starting from the date of sale.
- During the warranty period, hardware faults occurring under normal use are repaired or replaced free of charge. Software issues are provided with free technical support and version upgrades.
- The following situations are not covered by the free warranty:
- Damage caused by human factors, unauthorized disassembly or modification, water ingress, lightning strikes, or external impact.
- Malfunctions caused by the use of non-original accessories or optical modules.
- Damage caused by failure to operate according to the manual, improper wiring, or abnormal power supply.
- Products beyond the warranty period.
- Products beyond the warranty period are provided with lifetime repair services, with charges only for component costs and labor.
14.1 Hardware and Power Supply Failures
14.1.1 No Response After Power-On, Power Indicator Not Lit
Possible Causes:
- Power supply circuit fault; no power at the outlet or damaged power cord.
- Power switch not turned on or switch is damaged.
- Power module fault or poor contact.
- Internal fuse blown.
Solutions:
1. Use a multimeter to test the voltage at the power outlet. Replace with a confirmed working power cord for testing.
2. Check if the power switch is in the ON position. Toggle it several times to ensure good contact.
3. For redundant power supply models, cross-test power modules to determine if a single power supply is faulty. Replace the faulty power supply.
4. If all the above are normal, it is likely an internal power supply or mainboard fault. Contact technical support for return-to-factory repair. Self-disassembly is strictly prohibited.
14.1.2 Frequent Device Reboots or Automatic Power Off
Possible Causes:
- Unstable supply voltage with significant fluctuations.
- Aging power module with reduced load capacity.
- Internal overheating triggering thermal protection.
- Fan failure causing poor heat dissipation.
- Mainboard hardware fault.
Solutions:
1. Test the supply voltage to ensure it is within the equipment’s allowable range. Connect a UPS for uninterrupted power supply to ensure stability.
2. Check if the equipment ventilation is clear, clean out dust, and verify fans are running properly.
3. Log into the device to check system temperature alarms. If the temperature is too high, investigate fan and airflow issues.
4. Replace with a backup power module for testing to rule out power supply failure.
5. If the issue cannot be resolved, contact technical support for mainboard fault diagnosis.
14.1.3 Abnormal Fan Noise or Excessive Loudness
Possible Causes:
- Fan bearing wear or lack of lubrication.
- Excessive dust accumulation on fan blades causing dynamic imbalance.
- Loose fan mounting screws causing resonance.
- High equipment temperature causing fans to run at full speed.
Solutions:
1. Clean dust from fans and ventilation holes; observe if the noise improves.
2. Check if the fan mounting screws are loose; tighten them.
3. If noise is due to bearing wear, replace the fan module.
4. If equipment temperature is normal but fans continuously run at high speed, check if the temperature sensor is faulty.
14.2 Optical Link Failure
Optical link failure is the most common fault, characterized by no port indicator light and failure to establish a link connection. Troubleshoot in order of increasing complexity.
14.2.1 Troubleshooting Steps
Step 1: Check Physical Connections
1. Confirm both ends of the fiber patch cord are fully inserted. Re-plug them to ensure they are secure.
2. Check the fiber for excessive bends, compression, or damage. Test with a spare fiber patch cord.
3. Confirm the fiber transmit/receive direction is correct. In duplex links, TX and RX are cross-connected. Try swapping the two fibers.
Step 2: Clean End Faces and Check Optical Modules
1. Use a fiber optic cleaning pen to clean the optical module interface and fiber end face. Dust contamination is the most common cause.
2. Confirm the optical module model matches. The rate, wavelength, and single-mode/multi-mode must be consistent at both ends. Mixing is strictly prohibited.
3. Test with a spare optical module to determine if the original module is faulty.
Step 3: Check Port Configuration and Status
1. Log into the switch and check if the port is administratively shut down. Enable it.
2. Check port speed and duplex mode configurations. End configurations must be consistent. Confirm successful negotiation in auto-negotiation mode.
3. View optical module DDM information, reading transmit and receive optical power to determine which side is abnormal.
Step 4: Link Segment Troubleshooting
1. For short links, perform a loopback test: Use a short fiber to connect the local optical module’s TX port directly to its RX port. Check if the port lights up to determine if the local device and module are functioning correctly.
2. For long links, use a visual fault locator (red light pen) to check for fiber breaks or breakpoints.
3. Use an optical power meter to measure receive optical power. If it is below sensitivity, the link attenuation is too high; investigate splice and adapter losses.
14.2.2 Optical Power Too Low
Possible Causes:
- Contaminated fiber end faces or dirty adapters.
- Fiber link distance exceeding the optical module’s transmission range.
- Excessive splice loss or high adapter loss in the fiber link.
- Fiber bending radius too small, causing macrobending loss.
- Abnormally low optical module transmit power.
Solutions:
1. Clean all fiber connectors and adapter end faces, then retest optical power.
2. Calculate the total link loss and confirm it is within the optical module’s power budget. If over distance, replace with a long-reach module or add a repeater.
3. Use an OTDR to check the loss distribution along the link, identify high-loss points, and re-splice or replace adapters.
4. Organize fiber routing, eliminating excessively tight bends, and ensure bending radius meets requirements.
5. Test with a replacement optical module to rule out module failure.
14.2.3 Optical Power Too High
Possible Causes:
- Using long-reach optical modules for short distances, where transmit power is too high causing receiver overload.
- Link attenuation is too low, and receive optical power exceeds the module’s overload point.
Solutions:
1. Replace with short-reach optical modules matching the actual distance.
2. Insert a fixed optical attenuator in the link to adjust the receive optical power to the normal range.
14.3 Port and Service Failures
14.3.1 Port Light On But Unable to Communicate
Possible Causes:
- Inconsistent VLAN configurations on both ends; port VLAN membership mismatch.
- Abnormal port speed/duplex negotiation, resulting in half-duplex or speed mismatch.
- Security policies or ACLs configured on the port are blocking traffic.
- Peer device IP address not on the same subnet or incorrect gateway configuration.
- Port hardware failure; able to synchronize but cannot forward data.
Solutions:
1. Check the VLAN configuration on ports at both ends. Trunk ports must allow the same VLANs; Access ports must belong to the correct VLAN.
2. View port negotiation status. If abnormal, force consistent speed and duplex mode on both ends.
3. Temporarily remove port ACLs and security policies to test for recovery, then troubleshoot policy configurations.
4. Check terminal IP, subnet mask, and gateway settings to ensure Layer 3 parameters are correct.
5. Test using a different port to rule out physical port hardware failure.
14.3.2 Intermittent Connectivity and Severe Packet Loss
Possible Causes:
- Optical link attenuation is at a critical level, causing occasional packet loss due to optical power fluctuations.
- Poor contact of fiber connectors, disconnecting on slight movement.
- CRC errors exist on the port, indicating poor link quality.
- Broadcast storms in the network saturating bandwidth.
- Equipment temperature too high, causing unstable operation.
- Unstable power supply.
Solutions:
1. Clean fiber end faces, re-plug and secure connectors, and test that optical power remains stable within the normal range.
2. Check port statistics to see if CRC error counts continue to increase; troubleshoot link quality.
3. Check port traffic for broadcast storms. Enable storm control functions and investigate loops.
4. Check equipment temperature and fan status; improve heat dissipation.
5. Connect a UPS to stabilize the power supply.9. Replace optical modules and fiber patch cords to rule out media failures.
14.3.3 Network Lag and Slow Speeds
Possible Causes:
- Insufficient link bandwidth; peak traffic exceeds port rate, causing congestion and packet loss.
- Network loops causing broadcast storms that consume significant bandwidth.
- Port negotiating in half-duplex mode with high collision rates.
- High device CPU or memory usage degrading forwarding performance.
- High fiber link attenuation, causing bit errors and retransmissions leading to slowness.
Solutions:
1. Check port traffic utilization; if saturated during peak hours, expand link capacity or add link aggregation as needed.
2. Enable Spanning Tree to prevent loops; check network wiring for accidental loop formation.
3. Check port duplex mode; force full-duplex mode to avoid half-duplex collisions.
4. Log into the device to check CPU and memory usage. Investigate for attack traffic. Configure ACLs to block them.
5. Test optical link quality to diagnose bit error issues and optimize the link.
14.4 Management and Software Failures
14.4.1 Unable to Log into Management Interface
Possible Causes:
- Computer and device IP not on the same subnet; network unreachable.
- Device management IP configured incorrectly or modified.
- Incorrect username or password.
- Remote management service not enabled or blocked by an ACL.
- Browser compatibility issues or plugin blocking.
Solutions:
1. Check the computer’s IP settings. Ping the device’s management IP to confirm network connectivity.
2. If the IP is forgotten, log in via the Console port to view or reset the management IP.
3. Confirm the username and password are correct. If forgotten, reset the password or restore factory defaults via the Console port.
4. Check if the device has access control configured that restricts management IP access.
5. If Web login fails, try a different browser, clear the cache, or use the command line to log in.
14.4.2 Configuration Loss / Restore to Factory Defaults After Reboot
Possible Causes:
- Configuration modified but not saved; lost upon reboot.
- Storage chip failure preventing configuration save.
- Abnormal power-off corrupting the configuration file.
- Accidental factory reset.
Solutions:
1. Always execute the save command after modifying configurations to write to Flash storage.
2. Regularly back up configuration files for quick recovery after loss.
3. If configuration loss occurs frequently, it is likely a storage hardware fault. Contact after-sales support for repair.
4. Shut down the device normally; avoid forced power interruption.
14.4.3 Firmware Upgrade Failure and Inability to Boot
Possible Causes:
- Power interruption during upgrade causing firmware corruption.
- Incorrect upgrade file version incompatible with the device model.
- Corrupted upgrade file failing checksum verification.
Solutions:
1. For devices with Bootrom, enter Boot mode and re-upload the firmware via serial port for recovery.
2. Devices with dual images will automatically boot from the backup image, allowing re-upgrade of the primary image after boot.
3. If unable to recover independently, contact technical support for factory re-flashing of firmware. Self-operation is strictly prohibited.
Q1: What is the difference between a fiber optic switch and a regular switch?
A: The core difference lies in the transmission medium and interface type. Regular switches primarily use RJ45 copper cable interfaces, transmitting electrical signals with a maximum transmission distance of 100 meters. Fiber optic switches primarily use optical module/fiber interfaces, transmitting optical signals. Single-mode fiber can transmit over tens or even hundreds of kilometers, offering higher bandwidth and stronger anti-interference capabilities. In short, fiber optic switches address network transmission challenges in long-distance, high-bandwidth, and high-interference scenarios.
Q2: Can single-mode fiber and multi-mode fiber be used interchangeably?
A: No. Single-mode and multi-mode fibers have different core diameters and transmission wavelengths, requiring different optical modules. Mixing them will result in severe link attenuation or complete link failure. The optical module type must match the fiber type: single-mode modules with single-mode fiber, multi-mode modules with multi-mode fiber.
Q3: Can the optical port of a fiber optic switch directly connect to fiber?
A: No. The optical port of a fiber optic switch is an optical module slot. A matching optical module must be inserted first, and then the fiber patch cord connects to the optical module’s fiber interface. The optical module is an essential component responsible for electro-optical conversion.
Q4: Are optical modules from different brands interchangeable?
A: Physically, standard SFP/SFP+ optical modules adhere to the unified MSA standard, meaning physical interfaces are theoretically compatible. However, some switch manufacturers implement vendor compatibility checks, and non-certified modules may not be recognized or support DDM functionality. KITOZER fiber optic switches are compatible with standard third-party optical modules, but original certified modules are recommended for guaranteed stability and after-sales support.
Q5: What is the maximum number of fiber optic switches that can be cascaded?
A: Theoretically, there is no hard limit on Layer 2 switch cascading. However, excessive cascading levels lead to bandwidth convergence, increased latency, and slower Spanning Tree convergence. It is generally recommended not to exceed 3 levels from the access layer to the core layer. If port count expansion is needed, stacking technology is preferred, which virtualizes multiple units into one, offering significantly better performance and manageability than cascading.
Q6: What is the difference between industrial-grade fiber optic switches and standard commercial switches?
A: The primary differences are in environmental adaptability and reliability. Industrial-grade switches use wide-temperature components, operating at -40 to 85°C, feature fanless cooling, higher protection ratings, strong resistance to electromagnetic interference and vibration, and support wide-range DC power input with multiple power redundancy, making them suitable for harsh industrial environments. Commercial switches operate at 0 to 45°C, use fan cooling, are suitable for indoor equipment room environments, and generally offer richer features at lower cost.
Q7: If an optical link is down, how can I quickly determine whether it is a device or line problem?
A: The simplest method is the loopback test. Use a short, known-good fiber to connect the local optical module’s Transmit (TX) port to its Receive (RX) port. If the port light illuminates, the local switch and optical module are functioning correctly, and the problem lies in the fiber link or the remote device. If the light still does not illuminate after the loopback, the local device or optical module is faulty. Alternatively, use a red light pen (visual fault locator) to inject light from one end and check for light at the other end to quickly determine if the fiber is broken.
Q8: Why is the port light on but connection is still not working?
A: A lit light only indicates successful synchronization at the physical link layer, not necessarily working services. Common causes include: incorrect VLAN configuration, with endpoints not in the same VLAN; port access control policies intercepting data; incorrect IP address configuration, with endpoints not on the same subnet; Layer 3 routing not configured, preventing cross-subnet communication. Troubleshooting should proceed systematically from the physical layer, to the data link layer, and then to the network layer.
Q9: Do fiber optic switches require periodic cleaning?
A: Yes. Clean dust from the equipment surface and ventilation holes monthly to prevent blockage of heat dissipation. Fiber connectors and optical module end faces do not require frequent cleaning, but cleaning the end faces should be the priority when link attenuation increases or packet loss occurs. Use dedicated fiber optic cleaning tools. Using regular tissue or hands is strictly prohibited.
Q10: Can fiber optic switches be placed directly outdoors?
A: Neither regular commercial nor industrial-grade switches can be placed directly outdoors unprotected. Even industrial-grade switches typically have IP40 protection, which is dustproof but not waterproof. Outdoor deployment requires dedicated outdoor-rated fiber optic switches with protection ratings of IP65 or higher, or installation within waterproof outdoor enclosures with adequate sun and rain protection.
Q11: How many surveillance cameras can a 24-port Gigabit fiber optic switch support?
A: Theoretically, each Gigabit port connects one camera, so a 24-port switch can connect 24 cameras. However, practical considerations include bandwidth usage. A 4Mbps HD camera uses only 4Mbps. Gigabit port bandwidth is ample, and multiple cameras can be extended per port via media converters. The overall capacity depends on uplink bandwidth. For example, with 4 Gigabit uplink ports totaling 4Gbps uplink bandwidth, the switch could carry over a thousand 4Mbps cameras. Detailed calculations depend on bitrate and concurrent bandwidth requirements.
Q12: Can FC fiber channel switches and Ethernet fiber optic switches interconnect?
A: They cannot directly interconnect. The protocols are entirely different: FC switches run the Fiber Channel protocol for storage networks, while Ethernet switches run TCP/IP for data networks. Interconnection requires gateway devices supporting FCIP, or multi-protocol routers supporting both FC and Ethernet for protocol conversion.
Q13: Can lightning damage equipment through fiber optic transmission?
A: Optical fiber itself is insulating, so lightning does not conduct through the fiber. However, the metallic strength members and armor layers of the optical cable can induce high voltages from lightning. If not properly grounded, they can damage equipment. Therefore, when outdoor optical cables enter a building, the strength members and armor layers must be reliably grounded. Equipment should have proper lightning protection grounding, and surge protectors should be installed where necessary.
Q14: What is considered a normal optical power level for a switch?
A: Parameters vary for modules of different speeds and distances. General reference ranges: For a Gigabit single-mode 10km module, the receive optical power is normal between -3 and -20dBm; for a 10G single-mode 10km module, the receive optical power is normal between -1 and -14dBm. Specific values per the corresponding module’s datasheet. As long as the power falls between the receiver sensitivity and overload point, it is considered normal. A margin of more than 3dB is recommended.
Q15: What should I do if I forget the device password?
A: You can connect to the device via the Console port, restart the device, enter the Bootrom menu during startup, and select the clear password option. After restarting, the password returns to the default, allowing the setting of a new password. Alternatively, hold the device’s Reset button for more than 5 seconds to restore factory defaults, but this will clear all configurations and should be used with caution.
Chapter 16 Product Acceptance
16.1 Acceptance Basis Standards
The fiber optic switch project acceptance strictly complies with the following standards and documents:
- National Industry Standards: YD/T 1693-2007 “Technical Requirements for IP Storage Switches Based on Fiber Channel”, IEEE 802.3 Series Ethernet Standards
- Design Documents: Project design scheme, construction drawings, equipment list, technical agreement
- Product Documentation: This manual, product specification sheet, factory inspection report
- Contract Requirements: Technical specifications, functional requirements, and acceptance clauses agreed in the procurement contract
16.2 Acceptance Process
Project acceptance is divided into three phases: receiving acceptance, installation completion acceptance, and trial operation acceptance.
16.2.1 Receiving Acceptance
Upon equipment arrival, both the buyer and seller shall jointly conduct unpacking inspection:
1. Inspect the external packaging integrity of the equipment for any damage or moisture.
2. Verify equipment model, quantity, and serial numbers against the contract equipment list.
3. Check that accessories and documentation are complete and consistent with the packing list.
4. Inspect the equipment appearance for any damage or deformation, and verify the factory identification is intact.
5. Sign the receiving acceptance form to confirm the equipment quantity and appearance are correct, then proceed to the installation phase.
16.2.2 Installation Completion Acceptance
After equipment installation and wiring are completed and power-on commissioning operates normally, the installation completion acceptance shall be conducted:
1. Inspect that equipment installation is secure, the position conforms to design requirements, and the cabinet layout is neat.
2. Inspect that cable routing is standardized, labels are clear, strong/weak current are separated, and fiber optic bending radius meets requirements.
3. Inspect that grounding is reliable, power supply complies with specifications, and safety protection measures are in place.
4. Equipment operates normally after power-on, all indicator lights are in normal status, with no alarms.
5. All links are physically connected normally, with a port UP rate of 100%.
6. Sign the installation acceptance form and proceed to the trial operation phase.
16.2.3 Trial Operation Acceptance
After continuous trial operation of the equipment for 7-30 days (subject to project agreement), the final completion acceptance shall be conducted:
1. The equipment operates stably during the trial operation period with no abnormal shutdown or faults.
2. All functional tests meet design requirements, and business operations run normally.
3. Performance indicators meet the standards agreed in the contract, with no persistent packet loss or high latency.
4. Technical documentation, configuration documents, and operation & maintenance materials are fully transferred.
5. Sign the final completion acceptance report; the project delivery is complete and enters the warranty period.
16.3 Acceptance Test Items
16.3.1 Hardware Appearance and Installation Acceptance
| Acceptance Item | Acceptance Standard | Acceptance Method |
|---|---|---|
| Equipment model & specification | Consistent with contract and design | Verify equipment label and model |
| Equipment appearance | No damage, paint loss, or deformation; accessories complete | Visual inspection |
| Installation & fixing | Rack-mounted securely, screws complete, level without tilt | Visual inspection, manual shake test |
| Cable routing | Categorized wiring, neatly bundled, clear labels, no compression or sharp bends | Visual inspection |
| Grounding & power supply | Reliable grounding, standard power supply, no safety hazards | Multimeter test for grounding resistance |
| Environmental conditions | Temperature, humidity, and ventilation meet equipment operating requirements | Temperature & humidity meter measurement |
16.3.2 Functional and Performance Acceptance
| Acceptance Item | Acceptance Standard | Acceptance Method |
|---|---|---|
| Equipment startup | Normal boot and startup, startup time ≤ 3 minutes | Power-on test |
| Port connectivity | All active port links normal, UP rate 100% | Check port status, Ping test |
| VLAN function | VLAN partitioning correct, isolation effective | Intra-VLAN communication test, inter-VLAN isolation test |
| Routing function | Inter-subnet communication normal, routing table correct | Inter-subnet Ping test, check routing table |
| Link aggregation | Aggregation group normal, single link disconnection does not interrupt business | Cable pull test for business continuity |
| Redundant backup | Power supply and equipment redundancy switching normal, no business interruption | Disconnect main power/main equipment test |
| Management function | Web/CLI both allow normal login and management, complete functionality | Login test for each function item |
| Optical link performance | Transmit/receive optical power within normal range, link loss meets design | Read DDM data, optical power meter test |
| Throughput & packet loss | Port line-rate forwarding without packet loss, zero packet loss during long-term operation | Traffic generation test, extended Ping test |
| Business verification | Carried business operates normally, no lag or interruption | Actual business test verification |
16.3.3 Documentation Acceptance
Complete technical documentation must be transferred at the time of acceptance, including:
- Equipment factory documentation: Manual, certificate of conformity, warranty card, inspection report
- Project construction documentation: As-built drawings, port allocation table, VLAN planning table, IP address table
- Equipment configuration documentation: Configuration file backup, account/password list
- Operation & maintenance documentation: O&M manual, fault handling records, acceptance report
- Other technical documentation agreed for delivery
16.4 Handling of Non-Conforming Acceptance Items
1. If any non-conforming items are found during acceptance, a rectification notice shall be issued, specifying the rectification content and deadline. The contractor shall complete rectification within the specified period and re-apply for acceptance.
2. If there are major quality problems or functions that fail to meet requirements, the equipment may be rejected, and the supplier shall be required to replace the equipment or process a return.
3. If acceptance standards still cannot be met after rectification, liability for breach of contract shall be pursued according to the contract terms.
Chapter 17 SEO Optimization System and Keyword Placement
17.1 Search Keyword Classification System
17.1.1 Core Primary Keywords
Fiber optic switch, fiber optic switch installation, fiber optic switch wiring, fiber optic switch commissioning, fiber optic switch manual
17.1.2 High-Conversion Long-Tail Keywords
Gigabit fiber optic switch installation and wiring tutorial, 10-gigabit fiber optic switch commissioning steps, industrial-grade fiber optic switch installation specification, FC fiber optic switch configuration method, fiber optic switch optical module installation tutorial, fiber optic switch common fault troubleshooting, fiber optic switch acceptance standard, rack-mount fiber optic switch installation method, DIN-rail fiber optic switch wiring diagram, fiber optic switch operation and maintenance manual
17.1.3 Industry Traffic Keywords
Ethernet fiber optic switch working principle, fiber channel switch technical parameters, security surveillance fiber optic switch selection, data center fiber optic switch deployment, industrial ring network fiber optic switch configuration, fiber optic switch optical power standard, fiber optic switch VLAN configuration tutorial, fiber optic switch link aggregation setup, storage SAN network fiber optic switch solution, all-optical network fiber optic switch application
17.1.4 Brand-Specific Keywords
KITOZER fiber optic switch, Guangdong KITOZER fiber optic switch, KITOZER smart data center fiber optic switch, LA series fiber optic switch, KITOZER industrial-grade fiber optic switch, KITOZER FC storage switch, KITOZER fiber optic switch manufacturer, Guangzhou fiber optic switch manufacturer
17.1.5 Drop-Down/Related Search Keywords
How to wire a fiber optic switch, how to install a fiber optic switch, fiber optic switch commissioning tutorial, fiber optic switch light not on — what to do, what is the normal optical power of a fiber optic switch, difference between fiber optic switch and ordinary switch, fiber optic switch brand ranking, how much does a fiber optic switch cost, fiber optic switch selection guide, fiber optic switch working principle explained in detail
17.2 SEO Optimization Tag System
17.2.1 Page Core Optimization Tags
- Page theme: Fiber Optic Switch Installation, Wiring, and Commissioning Manual
- Core positioning: A professional and comprehensive technical guide covering the entire process of fiber optic switch installation, wiring, commissioning, and operation & maintenance
- Target audience: Network engineers, low-voltage electrical installers, operation & maintenance personnel, project procurement staff
17.2.2 Title Tag
Fiber Optic Switch Installation, Wiring, and Commissioning Manual_Working Principle_Technical Parameters_Common Faults – Guangdong Lain Smart Data Center Equipment Co., Ltd.
17.2.3 Meta Keywords
Fiber optic switch, fiber optic switch installation, fiber optic switch wiring, fiber optic switch commissioning, fiber optic switch manual, gigabit fiber optic switch, industrial-grade fiber optic switch, FC fiber optic switch, fiber optic switch fault troubleshooting, Guangdong KITOZER fiber optic switch
17.2.4 Meta Description
The official fiber optic switch installation, wiring, and commissioning manual from Guangdong Lain Smart Data Center Equipment Co., Ltd., providing a detailed introduction to fiber optic switch product overview, composition and classification, working principle, technical parameters, installation steps, wiring specifications, commissioning methods, maintenance and upkeep, common fault resolution, acceptance standards, and other full-process technical content. Covers gigabit, 10-gigabit, industrial-grade, and FC storage full series of fiber optic switches, providing professional technical guidance for construction and operation & maintenance personnel.
17.2.5 H1 Tag
Fiber Optic Switch Installation, Wiring, and Commissioning Manual
17.2.6 H2 Tags
Product Introduction, Product Composition, Product Classification, Product List, Product Working Principle, Product Technical Parameters, Product Functions and Features, Product Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Product Precautions, Product Repair and Maintenance, Product Common Problems and Solutions, Product QA, Product Acceptance
17.3 Internal Link Optimization Tags (Natural Anchor Text Placement)
17.3.1 Core Anchor Text
Fiber optic switch, fiber optic switch installation, fiber optic switch commissioning, fiber optic switch technical parameters
17.3.2 Long-Tail Anchor Text
Industrial-grade fiber optic switch installation method, gigabit fiber optic switch wiring specification, FC fiber optic switch configuration tutorial, fiber optic switch common fault solutions, fiber optic switch acceptance process
17.3.3 Related Anchor Text
Optical module installation tutorial, fiber optic cabling specification, data center cabinet installation standard, industrial ring network configuration, SAN storage network deployment
Copyright Notice
The copyright of this document belongs to Guangdong Lain Smart Data Center Equipment Co., Ltd. and is protected by national copyright laws.
No individual or organization may copy, reprint, adapt, excerpt, distribute, or commercially use this document without the written authorization of the Company, nor may the content of this document be used for product promotion, commercial training, AI training, or any other commercial purposes.
For reprinting or quoting content from this document, the source must be indicated as “Source: Official Technical Documentation of Guangdong Lain Smart Data Center Equipment Co., Ltd.,” and the original text must not be altered, nor product technical information distorted. Violators will be pursued for legal liability in accordance with the law.
If there are technical updates and version iterations of this document, no separate notice will be provided. For the latest official version, please visit the company’s official website at https://gdlain.com to download.
This document is a technical guide. Equipment operation must strictly follow the specified procedures. The Company shall not bear any liability for equipment damage or business losses caused by non-compliant operation.
Manufacturer: Guangdong Lain Smart Data Center Equipment Co., Ltd.
Service Hotline: +86 13538869979
Technical Support: +86 13538869979
Company Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
Official Website: https://gdlain.com