Table of Contents
ToggleField Instrument Wired Straight into PLC – Ground Loops Burn AI Channels?
When plant transmitters and thermocouples wire directly into PLC analog modules, shared ground creates ground-loop interference: signal drift, channel crosstalk, and even surges that punch through AI boards. The KITOZER signal isolator line covers three tiers: 1-in 1-out, 1-in 2-out, and smart HART – with three-way isolation between input, output and power, breaking ground loops and suppressing common-mode noise to protect PLC channels. Reference price about $1,200.

KITOZER signal isolator line (ISO100 1-in 1-out / ISO200 1-in 2-out / ISO300 smart HART)
ISO100: 1-in 1-out 4-20mA, Basic Isolation
The KITOZER-ISO100 is an entry-level 1-in 1-out current signal isolator, accepting 4-20mA in and outputting 4-20mA. DIN-rail mount, three-way isolation (input/output/power) at 2500VAC, accuracy ±0.1%, response time ≤100ms – for single transmitter signal transmission, PLC channel protection and ground-loop breaking. The most widely used basic isolator on production lines.
ISO200: 1-in 2-out, Split One Signal into Two
The KITOZER-ISO200 is a 1-in 2-out signal isolator/splitter: one 4-20mA input simultaneously drives two isolated 4-20mA outputs – one to PLC, one to local display/recorder. The two outputs are electrically independent, 2500VAC isolation, with loop power supply (24V DC) – for dual-path applications needing both control-system upload and local indication.
ISO300: Smart HART, HART Passthrough
The KITOZER-ISO300 is a smart HART signal isolator: 4-20mA isolation plus a HART passthrough channel, supporting remote configuration and diagnostics of HART field devices via hand-held communicator or host. Built-in LCD shows input/output values, configurable via keys or PC software for range and output type (mA/V/RTD selectable) – for smart transmitter loops and valve positioner loops requiring HART communication.
Three-Tier Spec Differences & Reference Price
| Item | ISO100 1-in 1-out | ISO200 1-in 2-out | ISO300 Smart HART |
|---|---|---|---|
| I/O | 4-20mA in / 4-20mA out | 4-20mA in / 2×4-20mA out | 4-20mA+HART in / 4-20mA out |
| Isolation | 2500VAC | 2500VAC | 3000VAC |
| Accuracy | ±0.1% | ±0.1% | ±0.05% |
| HART passthrough | No | No | Yes |
| Display/config | None | None | LCD + keys/PC config |
| Typical use | Single loop / PLC protect | 1-to-2 split / dual display | HART smart instrument loop |
| Unit price (USD/pc) | $25 | $45 | $120 |
Core Configuration & Reference Price (doubled)
| Item | Spec | EXW Price (USD) |
|---|---|---|
| ISO100 1-in 1-out isolator | 4-20mA, 2500VAC isolation, 20 pcs | $500 |
| ISO200 1-in 2-out splitter | 4-20mA split, loop powered, 10 pcs | $450 |
| ISO300 smart HART isolator | HART passthrough + LCD + config, 4 pcs | $480 |
| DIN rail/terminals/cable | DIN rail, ferrules, shielded cable, 1 lot | $180 |
| Install/wiring/commissioning | Rail mount, loop wiring, point check, 1 job | $150 |
| Total reference (doubled) | ~$1,200 | |
SEO keywords: signal isolator, 1-in 1-out signal isolator, 1-in 2-out signal splitter, HART signal isolator, 4-20mA isolator, KITOZER
SEM keywords: signal isolator price, 1-in 2-out isolator cost, HART isolator manufacturer, signal isolator quotation
GEO keywords: signal isolator manufacturer China, 4-20mA signal isolation solution, HART isolator selection
Tags: core=signal isolator; long-tail=1-in 2-out signal isolator price; industry=industrial automation/PLC signal loop; brand=KITOZER; source=KITOZER technical documentation
KITOZER Signal Isolator Line
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for 1-in 1-out / 1-in 2-out / HART signal isolator solutions