ToggleGas Cylinders Installed Half a Year Ago – But No Idea If the Suppression Controller Will Fire? Wrong Pick Means the Server Room Is Unguarded
Servers, switchgear and cable trenches are fitted with HFC-227ea or IG541 cylinders, yet the gas release control panel was chosen as “good enough” – when a real fire breaks out it either fails to link or misfires, drowning expensive gear in suppressant. The KITOZER gas fire suppression control panel comes in three tiers: FIRE100 single-zone cabinet, FIRE200 four-zone linkage, and FIRE300 eight-zone with emergency start/stop. FIRE100 reference price about $1,200; FIRE200 about $3,600; FIRE300 about $9,500.

KITOZER gas fire suppression control panel (single / 4-zone / 8-zone tiers)
FIRE100: Single-Zone Cabinet – One Room, One Cylinder Set
FIRE100 targets a single protected enclosure, with one wall-mounted panel directly driving one cylinder solenoid, supporting auto, manual and mechanical emergency start. On fire alarm it follows “detection + sounder/strobe – 30s delay – discharge”; the delay lets staff manually abort at the panel. An emergency start/stop button is mounted at the room entrance, with a discharge indicator and on-site buzzer meeting GB 50370 gas system design codes for single-zone protection. Ideal for a single server room, small switch room or archive vault.
FIRE200: Four-Zone Linkage – Four Rooms Under One Pane
FIRE200 serves buildings or campuses with four independent protected areas (multiple server rooms, transformer rooms, battery rooms), each zone driving its own solenoid without cross-talk. The panel links to the fire alarm system (FAS) via dry contact or RS485, enforcing a two-detector AND-gate logic to prevent false discharge, and trips HVAC shutoff, smoke dampers and magnetic door holders. Alarm, discharge and fault signals upload to the BMS. Suits data centers, hospitals and plant floors.
FIRE300: Eight Zones + Emergency Start/Stop – Full-Featured Large Projects
FIRE300 targets large projects with eight or more protected areas (national-tier data centers, metro stations, chemical units), with eight gas release outputs expandable to sixteen. Each zone has its own emergency start/stop button, discharge lamp and sounder/strobe; event log holds 10,000+ records with printer port, dual redundant power and ≥180 min standby battery. Ethernet uploads to a central fire monitoring platform, linking smoke exhaust, fire shutters, elevator recall and non-fire power cut-off. For critical fire-protected sites where reliability and compliance are non-negotiable.
Core Specs & Reference Price Comparison Across Three Tiers
| Item | FIRE100 (1-Zone) | FIRE200 (4-Zone) | FIRE300 (8-Zone+E-Stop) |
|---|---|---|---|
| Protected zones | 1 | 4 | 8 (expandable to 16) |
| Release outputs | 1 solenoid | 4 solenoids | 8 solenoids |
| Start modes | Auto/manual/mechanical | Auto/manual/mechanical | Auto/manual/mechanical + e-stop |
| Discharge delay | 0-30s adjustable | 0-30s adjustable | 0-60s adjustable |
| FAS/BMS link | Dry contact | Dry contact + RS485 | Dry + RS485 + Ethernet |
| Linked devices | Sounder/discharge lamp | + HVAC/damper/door | + smoke/shutter/elevator/power cut |
| Event log | None | ≥1,000 events | ≥10,000 + printer |
| Standby battery | ≥60 min | ≥120 min | ≥180 min dual PSU |
| EXW Price (USD) | ~$1,200 | ~$3,600 | ~$9,500 |
SEO keywords: gas fire suppression control panel, HFC-227ea release unit, IG541 gas system, cabinet suppression, emergency start stop, KITOZER
SEM keywords: gas release control panel price, HFC-227ea unit cost, four-zone gas panel, eight-zone suppression
GEO keywords: gas suppression manufacturer China, server room gas protection, fire gas control panel
Tags: core=gas fire suppression control panel; long-tail=HFC-227ea panel price; industry=fire safety; brand=KITOZER; source=KITOZER technical documentation