Table of Contents
ToggleGrowing from 6 to 24 Racks – How to Phase a Micro-Module Build-Out?
Most server rooms are not built in one shot: start with 6 racks, add 6 more after six months, then another 12 a year later. Paying for 24 racks on day one ties up cash; building a traditional civil cold aisle on day one means rework every expansion. KITOZER micro-modules come in three prefabricated sizes – MM100 single-row, MM200 double-row and MM400 four-row with cold aisle – shipped in factory-built sections and assembled on site, so each phase goes live without touching the last. Reference price for all three phases about $106,800.

KITOZER micro-module family (MM100 single / MM200 double / MM400 four-row with cold aisle)
MM100 Single-Row: 6 Racks to Get Started
A single row of six 42U racks, one 12.5kW in-row air conditioner between them, toughened glass end doors and pre-installed overhead cable tray. Whole cabinets ship from factory, on-site setup in one day. Built for small rooms starting out, 30kW IT load design, no expansion planned in 1-2 years.
MM200 Double-Row: 12 Racks as Business Grows
A back-to-back double row of twelve 42U racks, two 12.5kW in-row air conditioners, six electric roof hatches on the cold aisle that open automatically on smoke alarm. Built for mid-size rooms needing N+1 cooling redundancy, 60kW IT load design.
MM400 Four-Row: 24 Racks at Scale, Cold Aisle Included
Four rows totaling twenty-four 47U racks, four 12.5kW in-row ACs in N+1, electric hatches interlocked with gas fire suppression, built-in environment monitoring and water-leak detection. Built for production-scale rooms, 120kW IT load design, remote O&M ready.
Three-Phase Configuration & Reference Price
| Item | Spec | EXW Price (USD) |
|---|---|---|
| KITOZER-MM100 single-row micro-module | 6x 42U racks + 1x 12.5kW in-row AC + cold aisle, 1 set | $11,800 |
| KITOZER-MM200 double-row micro-module | 12x 42U racks + 2x 12.5kW in-row AC + electric hatches, 1 set | $27,500 |
| KITOZER-MM400 four-row micro-module | 24x 47U racks + 4x 12.5kW in-row AC + fire interlock + EMS, 1 set | $63,900 |
| Environment / water-leak integration | Temp-humidity / smoke / water sensors to platform, 1 job | $1,100 |
| Network cabling / cable managers | Cat6 / fiber patch / managers, all 3 phases | $800 |
| On-site installation & commissioning | Positioning, AC water/power hookup, joint test, 1 job | $1,700 |
| Total (three phases combined) | ~$106,800 | |
SEO keywords: micro-module rack, single-row micro-module, double-row micro-module, four-row micro-module, cold aisle micro-module, in-row air conditioner, KITOZER
SEM keywords: micro-module data center price, modular data center cost, in-row AC micro-module, prefabricated server room
GEO keywords: micro-module manufacturer China, modular server room solution, prefabricated data center
Tags: core=micro-module rack; long-tail=four-row cold-aisle micro-module price; industry=modular data center; brand=KITOZER; source=KITOZER technical documentation
KITOZER Micro-Module Rack
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn . gdlain.com
Contact us for MM100/MM200/MM400 micro-modules & phased server-room builds