KITOZER
KITOZER

High-Density Energy-Saving Computer Room Solution

I. Search Keywords, SEO and Tags

1.1 Core Search Keywords

High-density energy-saving computer room solution, modular computer room solution, high-density computer room energy-saving technology, modular computer room deployment, computer room energy-saving renovation plan, high-density cabinet solution, modular computer room construction, core technology of energy-saving computer room, computer room PUE optimization plan, integrated modular computer room, high-density computer room heat dissipation solution, green energy-saving computer room plan

1.2 SEO Optimization Points

Focusing on the two core solutions of high-density energy-saving computer rooms and modular computer rooms, this document fully covers users’ high-frequency search needs such as system introduction, configuration list, technical parameters, and application cases. Keywords are naturally distributed in the titles and main text of each chapter, highlighting the three core selling points of “energy saving”, “modularization” and “high density”. It adapts to the search engine crawling rules of external independent stations, and combines relevant specifications of green data centers, integrating industry hot words such as PUE optimization and waste heat utilization to improve page search ranking. The main text has a clear logic and distinct hierarchy, and each core module contains accurate keyword layout to avoid keyword stuffing, ensuring that both user browsing experience and SEO optimization meet the standards, helping potential customers quickly find the corresponding solutions.

1.3 Tags

High-density energy-saving computer room, modular computer room, computer room solution, computer room energy saving, modular deployment, high-density cabinet, computer room construction, PUE optimization, computer room heat dissipation, green data center, computer room intelligence, computer room operation and maintenance, energy-saving computer room renovation, modular integration, computer room infrastructure

II. Overall System Introduction

2.1 Introduction to High-Density Energy-Saving Computer Room Solution

The high-density energy-saving computer room solution is an integrated computer room infrastructure solution developed in response to the surging demand for computing power in current data centers, the continuous increase in cabinet power density, and the requirements of the “dual carbon” strategy and green data center construction. With the core goals of “high-density deployment, full-link energy saving, and high-reliability operation”, the solution integrates six core systems including cabinets, power supply and distribution, refrigeration, heat dissipation, monitoring, and fire protection. Through technological innovation and system coordination, it maximizes the utilization rate of computer room space and minimizes energy consumption, solving the pain points of traditional high-density computer rooms such as high energy consumption, prominent local hot spots, and difficult operation and maintenance. It is suitable for the construction and renovation needs of computer rooms in various high-computing scenarios such as AI, high-performance computing, and big data.

The solution strictly complies with national standards such as “Limited Values and Energy Efficiency Levels for Data Centers” (GB 40879-2021). Its core lies in controlling the computer room PUE value below 1.3 (standard from 2025 onwards) through precise refrigeration, efficient power supply, waste heat recovery, intelligent control and other technologies. At the same time, it supports the annual improvement of renewable energy utilization rate, realizing the coordinated development of computing power growth and energy saving and consumption reduction. According to the user’s actual computing power needs, the solution can flexibly configure cabinet density, refrigeration method and power supply redundancy, taking into account practicality and scalability. It can realize high-density computing power deployment without large-scale site renovation, greatly reducing the full-life cycle operation cost of the computer room, and is suitable for various computer room scenarios with high requirements for computing power density and energy saving efficiency.

2.2 Introduction to Modular Computer Room Solution

Based on the core concept of “standardized design, prefabricated production, modular assembly, and intelligent operation and maintenance”, the modular computer room solution decomposes the computer room infrastructure into multiple independent functional modules (cabinet module, power supply and distribution module, refrigeration module, monitoring module, fire protection module, etc.). Each module is prefabricated, assembled and commissioned in the factory. On-site, only modular assembly, pipeline connection and system commissioning are required to quickly complete the construction and deployment of the computer room. This solution completely breaks the limitations of traditional computer room construction such as long construction cycle, poor scalability, weak adaptability and complex operation and maintenance, and realizes the core needs of “plug-and-play, on-demand expansion and flexible adaptation” for computer room construction.

The solution adopts standardized module design, with unified and compatible interfaces for each module. According to the user’s business development needs, the number of modules can be flexibly increased or decreased, and the module configuration can be adjusted without reconstructing the overall structure of the computer room, perfectly adapting to the full-stage needs of the business from startup to large-scale development. At the same time, the module integrates an intelligent monitoring and operation and maintenance system, which can realize real-time monitoring, fault early warning and remote control of the operation status of each module, greatly reducing the cost of manual operation and maintenance. Combined with energy-saving technology and closed cold/hot channel design, the PUE value can be as low as 1.25, taking into account energy saving and reliability. The solution is suitable for various small and medium-sized computer rooms, edge computing computer rooms, temporary computer rooms and phased construction scenarios of large data centers. It can shorten the computer room construction cycle by more than 60%, greatly improving the efficiency of computer room construction and return on investment.

2.3 Synergistic Advantages of the Two Solutions

The high-density energy-saving computer room solution and the modular computer room solution can be deployed independently, or deeply integrated and operated collaboratively to form a composite computer room solution of “high density + modularization + energy saving”. After integration, it not only has the advantages of “rapid deployment, flexible expansion and standardized integration” of modular computer rooms, but also has the core characteristics of “high computing power, low energy consumption and high reliability” of high-density energy-saving computer rooms. It can achieve comprehensive value of “on-demand expansion of computing power, precise control of energy consumption, rapid and efficient construction, and intelligent and convenient operation and maintenance”, adapting to the computer room construction needs of more complex scenarios. It helps users quickly respond to the demand for computing power growth while controlling costs and reducing energy consumption, and consolidates the computing power base for the development of digital businesses.

III. System Configuration List (Brand: KITOZER)

3.1 High-Density Energy-Saving Computer Room Configuration List

System CategoryEquipment NameBrandSpecifications and Parameters (Core)Purpose
Cabinet SystemHigh-Density Server CabinetKITOZER42U/46U, depth 1200-1500mm, static load-bearing ≥1500kg, dynamic load-bearing ≥1000kg, supporting closed hot and cold channels, with ventilation mesh doors, compatible with various high-density serversCarry high-density servers, switches and other IT equipment, provide stable installation space, and assist in ventilation and heat dissipation
Cabinet PDU Power Distribution UnitKITOZER16A/32A input, 16-24 output channels, supporting overload, overvoltage and short-circuit protection, with remote monitoring interface, supporting energy consumption statisticsProvide stable and safe power distribution for IT equipment in the cabinet, and real-time monitor the power operation status
Hot and Cold Channel Enclosure ComponentsKITOZERAluminum alloy material, spliceable, suitable for different cabinet arrangement methods, with observation window, good sealing performance, supporting linkage with refrigeration systemRealize the separation of hot and cold airflows, reduce the mixing of hot and cold airflows, improve refrigeration efficiency and reduce energy consumption
Power Supply and Distribution SystemModular UPS Uninterruptible Power SupplyKITOZERCapacity 10-200KVA, modular design, supporting N+1/N+X redundancy, half-load efficiency ≥97%, total harmonic distortion (THDi) <3%, supporting photovoltaic DC grid connection, with intelligent monitoring functionWhen the commercial power is interrupted, provide uninterrupted power supply for the core equipment of the computer room to ensure the continuous operation of the equipment
Battery PackKITOZERValve-regulated sealed lead-acid battery/lithium battery, 12V/2V, capacity 100-2000Ah, cycle life ≥1500 times, supporting online monitoring, compatible with UPS systemProvide energy storage support for the UPS system to ensure that the UPS can continue to supply power after the commercial power is interrupted
Low-Voltage Power Distribution CabinetKITOZERCold-rolled steel plate material, protection grade IP40, supporting multiple input and output channels, with overload, short-circuit and leakage protection, supporting intelligent meteringRealize the distribution and control of commercial power in the computer room, and protect the safe and stable operation of the power supply and distribution system
High-Density BuswayKITOZERRated current 250-2500A, protection grade IP54, excellent heat dissipation performance, supporting flexible branching, suitable for high-density cabinet power supply needsProvide efficient and stable power transmission for high-density cabinets, replace traditional cables, and improve power supply reliability
Refrigeration and Heat Dissipation SystemPrecision Air Conditioner (Constant Temperature and Humidity)KITOZERCooling capacity 10-100kW, supporting frequency conversion control, constant temperature accuracy ±1℃, constant humidity accuracy ±5%RH, energy efficiency ratio (COP) ≥4.5, supporting linkage with hot and cold channelsProvide a stable constant temperature and humidity environment for the computer room, and solve the heat dissipation needs of high-density equipment
Cold Plate Liquid Cooling DeviceKITOZERSuitable for high-density cabinets, cooling power 5-30kW/cabinet, high heat exchange efficiency, supporting coordinated operation with air cooling system, leak-free protectionFor ultra-high-density cabinets, realize chip-level precise heat dissipation and solve local hot spot problems
Waste Heat Recovery DeviceKITOZERCombined with lithium bromide absorption refrigeration principle, recover CPU and equipment waste heat and convert it into refrigeration energy, waste heat recovery rate ≥80%Recover the waste heat generated by the operation of computer room equipment, realize secondary utilization of energy, and further reduce energy consumption
Monitoring SystemComputer Room Intelligent Monitoring HostKITOZERSupport multi-system integration, can monitor power supply and distribution, refrigeration, fire protection, environment and other parameters, with LCD touch screen, support remote login and controlUnified control of the operation status of each system in the computer room, real-time collection of operation data, and realization of centralized monitoring
Various Monitoring SensorsKITOZERIncluding temperature and humidity, smoke, water leakage, current, voltage, energy consumption and other sensors, high precision, fast response speed, supporting linkage alarmReal-time collection of various operation parameters and environmental data of the computer room, providing data support for the monitoring system
Fire Protection SystemHeptafluoropropane Fire Extinguishing SystemKITOZERNon-piped/piped type, high fire extinguishing efficiency, no damage to electronic equipment, no residue, supporting linkage triggering with monitoring systemQuickly extinguish fire when fire breaks out in the computer room, and protect the safety of computer room equipment and data
Fire Alarm ControllerKITOZERSupport dual detection of smoke and temperature, with sound and light alarm, can link fire extinguishing system and ventilation system, support remote alarmMonitor fire hazards in the computer room, issue alarm signals in time, and trigger the start of the fire extinguishing system
Auxiliary SystemComputer Room Fresh Air SystemKITOZERAir volume 500-5000m³/h, with filtering and heat exchange functions, filtering precision ≥G4, supporting linkage with refrigeration systemIntroduce fresh air into the computer room, discharge dirty air, improve the air quality of the computer room, and assist in energy saving

3.2 Modular Computer Room Configuration List

Module CategoryEquipment NameBrandSpecifications and Parameters (Core)Purpose
Cabinet ModuleStandardized Cabinet ModuleKITOZER42U/46U, factory prefabricated, depth 1000-1500mm, load-bearing ≥1200kg, integrated PDU and ventilation system, spliceableCarry IT equipment, serve as the core carrier of the modular computer room, and factory prefabrication ensures consistency
Module Splicing PartsKITOZERAluminum alloy material, standardized design, suitable for various cabinet modules, firm splicing and good sealing performanceRealize rapid splicing of multiple cabinet modules, ensuring stable connection and sealing between modules
Cabinet Ventilation CoverKITOZEROpenable, with ventilation mesh, suitable for closed hot and cold channels, supporting linkage with refrigeration moduleAssist in cabinet ventilation and heat dissipation, cooperate with hot and cold channel design to improve refrigeration efficiency
Power Supply and Distribution ModulePrefabricated UPS ModuleKITOZERCapacity 5-100KVA, modular design, factory prefabricated and commissioned, supporting N+1 redundancy, efficiency ≥96%Provide uninterrupted power supply for the entire modular computer room, rapid deployment without on-site commissioning
Prefabricated Power Distribution ModuleKITOZERIntegrated power distribution cabinet and terminal block, standardized interface, factory prefabricated, supporting multiple power distributionRealize power distribution and control of the modular computer room, and quickly connect with other modules
Battery ModuleKITOZERIntegrated battery pack and battery management system, factory prefabricated, supporting online monitoring, compatible with UPS moduleProvide energy storage support for the UPS module, integrated design saves space and is easy to maintain
Refrigeration ModulePrefabricated Precision Air Conditioning ModuleKITOZERCooling capacity 5-50kW, frequency conversion control, constant temperature and humidity, factory prefabricated and integrated, supporting linkage with cabinet moduleProvide precise refrigeration for the modular computer room, rapid deployment, and cooperative work with the cabinet module
Closed Channel ModuleKITOZERFactory prefabricated, aluminum alloy material, with observation window, suitable for various module combinations, good sealing performanceRealize the closure of hot and cold channels, reduce the mixing of hot and cold airflows, and improve the energy-saving effect of the refrigeration module
Monitoring ModulePrefabricated Monitoring ModuleKITOZERIntegrated monitoring host, sensors and alarm devices, factory prefabricated and commissioned, supporting remote control and linkageReal-time monitoring of the operation status of each system in the modular computer room, quick connection with other modules, and realization of intelligent control
Remote Operation and Maintenance ModuleKITOZERSupport 4G/5G/WiFi connection, enabling remote login, data viewing, fault early warning and remote debuggingRealize remote operation and maintenance of the modular computer room, reducing the workload of manual on-site operation and maintenance
Fire Protection ModulePrefabricated Heptafluoropropane Fire Extinguishing ModuleKITOZERNon-piped type, factory prefabricated and integrated, high fire extinguishing efficiency, supporting linkage with monitoring module, no residueProvide fire protection for the modular computer room, rapid deployment without occupying additional space
Fire Alarm ModuleKITOZERIntegrated smoke and temperature sensors, sound and light alarm, factory prefabricated, supporting linkage with fire extinguishing moduleMonitor fire hazards in the modular computer room, issue alarm signals in time, and trigger fire extinguishing actions
Auxiliary ModulePrefabricated Fresh Air ModuleKITOZERAir volume 300-3000m³/h, with filtering and heat exchange functions, factory prefabricated, supporting linkage with refrigeration moduleIntroduce fresh air into the modular computer room, improve air quality, and assist in energy saving
Wiring ModuleKITOZERPrefabricated wiring trough and terminal block, standardized design, supporting separation of strong and weak electricity, easy wiring and maintenanceRealize the wiring of strong and weak electricity in the modular computer room, standardize the wiring layout, and facilitate later expansion and maintenance

IV. System Schematic Diagram

4.1 Schematic Diagram of High-Density Energy-Saving Computer Room System (Core Logic)

Core Logic: Commercial power access → Low-voltage power distribution cabinet → Modular UPS system (linked with battery pack) → High-density busway/PDU → IT equipment in the cabinet (high-density deployment); at the same time, the refrigeration system (precision air conditioner + cold plate liquid cooling device) provides precise refrigeration for IT equipment through hot and cold channel closure technology. The waste heat recovery device recovers the waste heat of IT equipment and converts it into refrigeration energy to realize secondary utilization of energy; the monitoring system real-time collects various parameters such as power supply and distribution, refrigeration, environment, and fire protection to realize intelligent control and fault early warning; the fire protection system is linked with the monitoring system to real-time monitor fire hazards and ensure the safe operation of the computer room.

Detailed Process:

  1. Power Supply Link: Commercial power is connected to the low-voltage power distribution cabinet, which is divided into two paths after distribution: one path supplies power to the modular UPS system, and the other path directly supplies power to non-core auxiliary equipment; the UPS system is linked with the battery pack. When the commercial power is normal, the UPS is in the voltage stabilization and filtering state, and charges the battery pack at the same time; when the commercial power is interrupted, the UPS immediately switches to the battery power supply mode, and provides uninterrupted power to the high-density IT equipment in the cabinet through the busway and PDU to ensure the continuous operation of the equipment and meet the high-reliability power supply demand of the computer room.
  2. Refrigeration and Heat Dissipation Link: According to the data from the temperature and humidity sensors in the computer room, the precision air conditioner automatically adjusts the cooling capacity, and precisely sends cold air into the cold channel through the hot and cold channel enclosure components. The hot air discharged by the IT equipment enters the hot channel and is recovered by the air conditioner return air outlet to realize the separation of hot and cold airflows and improve refrigeration efficiency; for ultra-high-density cabinets, the cold plate liquid cooling device directly contacts the server chip to realize chip-level precise heat dissipation and solve local hot spot problems; the waste heat recovery device collects the equipment waste heat in the hot channel, and converts the waste heat into refrigeration energy through the lithium bromide absorption refrigeration principle to supply the refrigeration system, further reducing refrigeration energy consumption and optimizing the computer room PUE value.
  3. Monitoring Link: Various sensors (temperature and humidity, current, voltage, smoke, water leakage, etc.) real-time collect the operation parameters of the computer room and transmit them to the intelligent monitoring host; the monitoring host analyzes and processes the data, real-time displays the operation status of each system, and immediately issues a sound and light alarm when the parameters are abnormal, and pushes the alarm information through the remote operation and maintenance interface; at the same time, the monitoring host is linked with the refrigeration, power supply and distribution, fire protection and other systems to realize intelligent adjustment (such as adjusting the air conditioning cooling capacity according to the computer room load, optimizing the power supply distribution according to the energy consumption data), and improving the efficiency of computer room operation and maintenance.
  4. Fire Protection Link: The fire alarm controller real-time monitors the data of smoke and temperature sensors. When a fire hazard is detected, it immediately issues a sound and light alarm and links the monitoring system to push the alarm information; if the fire is confirmed, the fire controller automatically triggers the heptafluoropropane fire extinguishing system to spray fire extinguishing agent into the computer room to quickly extinguish the fire, and at the same time links the ventilation system to close to prevent the spread of fire and protect the safety of IT equipment and data.

Schematic Note: The system design strictly complies with “Limited Values and Energy Efficiency Levels for Data Centers” (GB 40879-2021), supports renewable energy access, and can flexibly configure various system parameters according to user needs to adapt to different density computing power deployment, realizing the dual improvement of energy saving and reliability.

4.2 Schematic Diagram of Modular Computer Room System (Core Logic)

Core Logic: With standardized modules as the core, each functional module (cabinet module, power supply and distribution module, refrigeration module, monitoring module, fire protection module, etc.) is prefabricated in the factory. On-site, rapid docking and collaborative operation between modules are realized through standardized interface splicing; commercial power is connected to the power supply and distribution module, which supplies power to each module after processing; the refrigeration module is linked with the cabinet module to realize precise refrigeration through the closed channel; the monitoring module uniformly controls the operation status of each module to realize intelligent operation and maintenance; the fire protection module is linked with the monitoring module to ensure the safety of the computer room; each module can be increased or decreased on demand and flexibly expanded to adapt to the needs of business development.

Detailed Process:

  1. Module Splicing and Docking: On-site, the cabinet module, power supply and distribution module, refrigeration module, monitoring module, fire protection module, etc. are spliced and fixed through standardized splicing parts. Each module is quickly docked through standardized interfaces (power supply interface, signal interface, pipeline interface) without large-scale on-site wiring and commissioning, which greatly shortens the construction cycle; the wiring module integrates strong and weak electricity pipelines to realize pipeline connection between modules, standardize the wiring layout, and facilitate later maintenance and expansion.
  2. Power Supply Link: Commercial power is connected to the prefabricated power distribution module, which is divided into two paths after distribution by the power distribution cabinet: one path supplies power to the prefabricated UPS module, and the other path directly supplies power to the auxiliary equipment of each module; the UPS module is linked with the battery module. When the commercial power is normal, it provides stabilized and filtered power for the core equipment of each module, and charges the battery module at the same time; when the commercial power is interrupted, the UPS module immediately switches to battery power supply to ensure the continuous operation of the core equipment of each module. The power supply and distribution module supports N+1 redundancy configuration to improve power supply reliability.
  3. Refrigeration Link: The prefabricated refrigeration module (precision air conditioner) is linked with the cabinet module and the closed channel module, and automatically adjusts the cooling capacity according to the temperature and humidity data collected by the monitoring module; the closed channel module realizes the separation of hot and cold airflows, and the cold air is sent into the cabinet module through the cold channel to dissipate heat for the IT equipment. The hot air enters the hot channel and is recovered by the return air outlet of the refrigeration module to realize precise refrigeration and reduce energy consumption; the refrigeration module supports frequency conversion control, which can dynamically adjust the refrigeration power according to the changes of the computer room load, further improving the energy-saving effect.
  4. Monitoring and Operation and Maintenance Link: The prefabricated monitoring module integrates a monitoring host, various sensors and a remote operation and maintenance interface, which real-time collects the operation parameters (power supply parameters, refrigeration parameters, environmental parameters, etc.) of each module and transmits them to the monitoring host; the monitoring host analyzes and processes the data, real-time displays the operation status of each module, issues an alarm information when a fault occurs, and pushes it to the remote operation and maintenance terminal; the operation and maintenance personnel can realize remote login, data viewing, fault early warning and remote debugging through the remote operation and maintenance module, which greatly reduces the cost of manual operation and maintenance; the monitoring module supports collaborative control of multiple modules, and can intelligently adjust system parameters according to the operation status of each module.
  5. Fire Protection Link: The prefabricated fire protection module (heptafluoropropane fire extinguishing system + fire alarm controller) is linked with the monitoring module. The fire alarm controller real-time monitors the smoke and temperature data. When a fire hazard is detected, it immediately issues a sound and light alarm and links the monitoring module to push the alarm information; if the fire is confirmed, the fire controller automatically triggers the fire extinguishing system to spray fire extinguishing agent to the corresponding module area to quickly extinguish the fire, and at the same time links the refrigeration and ventilation systems to close to prevent the spread of fire and protect the safety of equipment and data in the module; the fire protection module adopts modular design, which can be flexibly configured according to the number of modules.

Schematic Note: Each module adopts standardized design with unified and compatible interfaces. According to the user’s business development needs, the number of modules can be flexibly increased or decreased, and the module configuration can be adjusted without reconstructing the overall structure of the computer room; the solution supports phased construction. In the early stage, core modules can be deployed according to the computing power demand, and in the later stage, with the business growth, gradual expansion can be carried out to reduce the initial investment cost; at the same time, the mode of factory prefabrication and on-site rapid splicing of modules can shorten the computer room construction cycle by more than 60%, greatly improving the efficiency of computer room construction and return on investment.

V. Product Technical Parameters

5.1 Core Product Technical Parameters of High-Density Energy-Saving Computer Room

5.1.1 Core Product Parameters of Cabinet System

Product NameCore Technical Parameters
High-Density Server Cabinet1. Specifications: 42U/46U, height 2000/2200/2500mm, width 600/800mm, depth 1200-1500mm; 2. Material: Cold-rolled steel plate, thickness 1.2-2.0mm, surface electrostatic spraying, corrosion and wear resistance; 3. Load-bearing: Static load-bearing ≥1500kg, dynamic load-bearing ≥1000
Shopping Cart